Open-source cardiac magnetic resonance fingerprinting
Authors:
- Patrick SchuenkePSPatrick Schuenke
- Catarina Redshaw KranichCKCatarina Redshaw Kranich
- Max LutzMLMax Lutz
- Jakob SchattenfrohJSJakob Schattenfroh
- Matthias AndersMAMatthias Anders
- Philine ReisdorfPRPhiline Reisdorf
- Jeanette Schulz-MengerJSJeanette Schulz-Menger
- Ingolf SackISIngolf Sack
- Jesse HamiltonJHJesse Hamilton
- Nicole SeiberlichNSNicole Seiberlich
- Christoph KolbitschCKChristoph Kolbitsch
Open Access
- 21 June 2025
- journal article
- research article
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 38 (4) , 1-13
Abstract
Purpose: Cardiac magnetic resonance fingerprinting (cMRF) is a powerful quantitative imaging technique that provides multi-parametric diagnostic information. Here, we introduce an open-source framework for cardiac MRF including open-source pulse sequences, image reconstruction, and parameter estimation tools that are needed for the processing of the data. Methods: A 2D cMRF sequence with a variable-density spiral readout is implemented using the open-source and vendor-agnostic sequence format Pulseq. Cardiac triggering is used to synchronize acquisition with the rest period of the heart. $$T_1$$ inversion and $$T_2$$ preparation pulses are added to ensure accurate parameter estimation. Data acquisition is carried out over 15 heartbeats. The images showing the signal changes over time are reconstructed and matched to a pre-calculated signal dictionary. In addition to the cMRF sequence, spin-echo reference sequences for quality control in phantoms are provided. The method is evaluated in phantom experiments using a T1MES phantom on four different scanners. In vivo experiments were performed to compare the open-source cMRF sequence with a vendor-specific cMRF sequence and clinical sequences used for $$T_1$$ and $$T_2$$ mapping of the heart. Three volunteers were imaged on two different scanners. Results: The error of $$T_1$$ and $$T_2$$ over all tissue types present in the T1MES phantom was comparable between all four scanners and on average 4.50 ± 2.48%. $$T_1$$ and $$T_2$$ maps obtained in vivo were comparable between the open-source and vendor-specific implementation of cMRF. Conclusion: The proposed open-source cMRF implementation enables accurate parameter estimation across multiple different scanners. Sequence files, image reconstruction, and parameter estimation scripts are available for reproducible quantitative MRI.
Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (372486779)
- Deutsche Forschungsgemeinschaft (289347353)
- European Partnership on Metrology (22HLT02A4IM)
- Physikalisch-Technische Bundesanstalt (PTB)
This publication has 45 references indexed in Scilit:
- Extended phase graphs: Dephasing, RF pulses, and echoes ‐ pure and simpleJournal of Magnetic Resonance Imaging, 2014
- Cardiovascular magnetic resonance imaging in ischemic heart diseaseJournal of Magnetic Resonance Imaging, 2012
- Gradient system characterization by impulse response measurements with a dynamic field cameraMagnetic Resonance in Medicine, 2012
- Simple method for MR gradient system characterization and k‐space trajectory estimationMagnetic Resonance in Medicine, 2011
- Flexible retrospective selection of temporal resolution in real-time speech MRI using a golden-ratio spiral view orderMagnetic Resonance in Medicine, 2010
- T2 measurement of the human myocardium using a T2‐prepared transient‐state trueFISP sequenceMagnetic Resonance in Medicine, 2007
- Spiral balanced steady‐state free precession cardiac imagingMagnetic Resonance in Medicine, 2005
- Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heartMagnetic Resonance in Medicine, 2004
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Coronary Angiography with Magnetization‐Prepared T2 ContrastMagnetic Resonance in Medicine, 1995