Ye Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ye Zhu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Shan Jiang
School of Electrical Engineering and Telecommunications, UNSW Sydney, Sydney, NSW, Australia
17 shared publications - Georgios Konstantinou
UNSW Sydney
16 shared publications - Josep Pou
City University of Hong Kong
3 shared publications - Tianyi Xu
School of Electrical Engineering and Telecommunications, UNSW Sydney, Sydney, NSW, Australia
3 shared publications - Ke Ma
Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
2 shared publications - Chunju Fan
Schoool of Electronic Information and Electrical engineering, University of Shanghai Jiao Tong, Shanghai, China
1 shared publication
Latest Publications
- Open Access
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1-16
Unified First-Order Power Synchronization Control of Grid-Forming Converters
Power synchronization control (PSC) plays a critical role in shaping the frequency response of grid-forming (GFM) converters. However, existing PSC implementations are developed with diverse control structures, which hinders a unified interpretation of their dynamic characteristics and associated design trade-offs. This paper demonstrates that common PSC methods, i.e., constant power, droop, and virtual synchronous generator (VSG) control, can be unified by a first-order transfer function (termed the complex droop factor) with four coefficients and up to three degrees of freedom. This unified representation reveals how PSC inherently governs both primary frequency response (PFR) and virtual inertial response (VIR). In particular, constant power control provides only VIR, droop control provides only PFR, and VSG control provides both. However, VSG control is prone to synchronization instability as it is essentially a proportional–derivative controller. To overcome these limitations, a fractional VSG control is proposed to bridge the gap between droop and VSG control. By independently regulating three degrees of freedom, the proposed method enables flexible shaping of droop, inertia and damping characteristics, allowing simultaneous consideration of power overshoot, frequency deviation, and response speed during disturbances. Furthermore, a three-step tuning guideline is developed to facilitate practical parameter design while maintaining consistency with classical VSG control principles, followed by an adaptive control law that yields adaptive virtual inertia. The proposed method is validated through experimental studies under various network transients and operating conditions with different system strengths.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1-16
Open AccessUnified First-Order Power Synchronization Control of Grid-Forming Converters
Power synchronization control (PSC) plays a critical role in shaping the frequency response of grid-forming (GFM) converters. However, existing PSC implementations are developed with diverse control structures, which hinders a unified interpretation of their dynamic characteristics and associated design trade-offs. This paper demonstrates that common PSC methods, i.e., constant power, droop, and virtual synchronous generator (VSG) control, can be unified by a first-order transfer function (termed the complex droop factor) with four coefficients and up to three degrees of freedom. This unified representation reveals how PSC inherently governs both primary frequency response (PFR) and virtual inertial response (VIR). In particular, constant power control provides only VIR, droop control provides only PFR, and VSG control provides both. However, VSG control is prone to synchronization instability as it is essentially a proportional–derivative controller. To overcome these limitations, a fractional VSG control is proposed to bridge the gap between droop and VSG control. By independently regulating three degrees of freedom, the proposed method enables flexible shaping of droop, inertia and damping characteristics, allowing simultaneous consideration of power overshoot, frequency deviation, and response speed during disturbances. Furthermore, a three-step tuning guideline is developed to facilitate practical parameter design while maintaining consistency with classical VSG control principles, followed by an adaptive control law that yields adaptive virtual inertia. The proposed method is validated through experimental studies under various network transients and operating conditions with different system strengths.
- 7 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Phase Jump Response of Grid-Forming Converters: Definition, Classification and Mitigation
Grid-forming (GFM) converters could misinterpret phase jumps as rms voltage or frequency variations, leading to misbehavior in phase jump response. This paper reveals that the transient response of GFM converters during phase jumps can be classified into three typical modes, i.e., fast recovery, slow recovery, and loss of synchronism, which can be determined by two operational boundaries. The first operational boundary is correlated to the relationship between the actual phase jump angle and the critical value (namely the phase displacement between the normal operating point and the unstable equilibrium point). The second operational boundary is determined by damping and inertia settings, of which the most conservative case can be captured by the Equal Area Criterion. Stability analysis provides valuable guidance for formulating grid specifications and testing requirements related to the phase jump response of GFM converters. Furthermore, this paper discusses strategies to prevent loss of grid synchronism and achieve fast recovery following phase jumps by employing mitigation solutions based on phase jump-sensitive electrical parameters. Theoretical analysis and mitigation methods are experimentally verified in a GFM converter system under different phase jump scenarios.
- 7 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Phase Jump Response of Grid-Forming Converters: Definition, Classification and Mitigation
Grid-forming (GFM) converters could misinterpret phase jumps as rms voltage or frequency variations, leading to misbehavior in phase jump response. This paper reveals that the transient response of GFM converters during phase jumps can be classified into three typical modes, i.e., fast recovery, slow recovery, and loss of synchronism, which can be determined by two operational boundaries. The first operational boundary is correlated to the relationship between the actual phase jump angle and the critical value (namely the phase displacement between the normal operating point and the unstable equilibrium point). The second operational boundary is determined by damping and inertia settings, of which the most conservative case can be captured by the Equal Area Criterion. Stability analysis provides valuable guidance for formulating grid specifications and testing requirements related to the phase jump response of GFM converters. Furthermore, this paper discusses strategies to prevent loss of grid synchronism and achieve fast recovery following phase jumps by employing mitigation solutions based on phase jump-sensitive electrical parameters. Theoretical analysis and mitigation methods are experimentally verified in a GFM converter system under different phase jump scenarios.
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (2) , 2277-2289
Unbalanced Fault Ride-Through in Grid-Forming Modular Multilevel Converters
Unbalanced grid conditions generate negative-sequence (NS) components in power systems and lead to oscillating output power from converters, posing technical challenges to the fault ride-through (FRT) capabilities of grid-forming (GFM) converters. The current limiter in the GFM converter avoids overcurrent issues during contingencies but it compromises system synchronization stability under grid voltage sags if the power synchronization loop (PSL) is used. This paper proposes a GFM control scheme based on the current synchronization loop (CSL) as a generalized solution for enhancing system synchronization stability under both balanced and unbalanced grid voltage sags. Theoretical analysis informs the selection of power control coefficients to coordinate unbalanced FRT objectives, including oscillating active power elimination and negative-sequence voltage suppression. An adaptive unbalanced limiter for GFM modular multilevel converters (MMCs) is further proposed based on the characteristics of the internal arm current, making full use of the power semiconductor current ratings and improving fault current contribution. The combination of the adaptive current limiter with the CSL-based GFM control allows GFM MMCs to provide additional reactive power to support positive-sequence voltage and suppress NS voltage at the PCC, enhancing their unbalanced FRT capabilities. All these grid supporting functionalities are quantified and validated with hardware experimental results from a laboratory-scale, grid-connected GFM MMC system.
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (2) , 2277-2289
Unbalanced Fault Ride-Through in Grid-Forming Modular Multilevel Converters
Unbalanced grid conditions generate negative-sequence (NS) components in power systems and lead to oscillating output power from converters, posing technical challenges to the fault ride-through (FRT) capabilities of grid-forming (GFM) converters. The current limiter in the GFM converter avoids overcurrent issues during contingencies but it compromises system synchronization stability under grid voltage sags if the power synchronization loop (PSL) is used. This paper proposes a GFM control scheme based on the current synchronization loop (CSL) as a generalized solution for enhancing system synchronization stability under both balanced and unbalanced grid voltage sags. Theoretical analysis informs the selection of power control coefficients to coordinate unbalanced FRT objectives, including oscillating active power elimination and negative-sequence voltage suppression. An adaptive unbalanced limiter for GFM modular multilevel converters (MMCs) is further proposed based on the characteristics of the internal arm current, making full use of the power semiconductor current ratings and improving fault current contribution. The combination of the adaptive current limiter with the CSL-based GFM control allows GFM MMCs to provide additional reactive power to support positive-sequence voltage and suppress NS voltage at the PCC, enhancing their unbalanced FRT capabilities. All these grid supporting functionalities are quantified and validated with hardware experimental results from a laboratory-scale, grid-connected GFM MMC system.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 8886-8898
Frequency Domain Inertia Design of Grid-Forming Converters
Synthetic inertia plays a pivotal role in the frequency response of grid-forming (GFM) converters. A small inertia factor provides insufficient inertia power to resist frequency variations during grid contingencies. By contrast, a large inertia factor allows GFM converters to mimic the dynamic response of synchronous generators but could compromise grid synchronization during extreme frequency events, e.g., frequency disturbances from 47 to 52 Hz or phase jumps up to $60^\circ$. This happens when a current-limiting GFM converter fails to track a output power reference governed by the power synchronization loop (PSL). Unlike conventional inertia designs that use fixed inertia factors, this article proposes a frequency domain inertia design method for GFM converters based on a modified bandwise PSL. The equivalent inertia factor of GFM converters can be defined as a transfer function by leveraging the equivalence between the high-frequency droop power component and the low-frequency inertia power component, such that the inertia factor is frequency-dependent and varies across different frequency ranges. The proposed inertia design solution combines the advantages of conventional low- and high-inertia design, providing large inertia factor in low-frequency range to mitigate frequency disturbances and small inertia factor in high-frequency range to facilitate power and frequency recovery. The dynamic response of GFM converters adopting the proposed design is experimentally verified and also demonstrated in an accompanied video file under different scenarios including network transients, such as grid phase jumps, grid voltage sags and frequency excursions, as well as operational events of power step change and load reduction.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 8886-8898
Frequency Domain Inertia Design of Grid-Forming Converters
Synthetic inertia plays a pivotal role in the frequency response of grid-forming (GFM) converters. A small inertia factor provides insufficient inertia power to resist frequency variations during grid contingencies. By contrast, a large inertia factor allows GFM converters to mimic the dynamic response of synchronous generators but could compromise grid synchronization during extreme frequency events, e.g., frequency disturbances from 47 to 52 Hz or phase jumps up to $60^\circ$. This happens when a current-limiting GFM converter fails to track a output power reference governed by the power synchronization loop (PSL). Unlike conventional inertia designs that use fixed inertia factors, this article proposes a frequency domain inertia design method for GFM converters based on a modified bandwise PSL. The equivalent inertia factor of GFM converters can be defined as a transfer function by leveraging the equivalence between the high-frequency droop power component and the low-frequency inertia power component, such that the inertia factor is frequency-dependent and varies across different frequency ranges. The proposed inertia design solution combines the advantages of conventional low- and high-inertia design, providing large inertia factor in low-frequency range to mitigate frequency disturbances and small inertia factor in high-frequency range to facilitate power and frequency recovery. The dynamic response of GFM converters adopting the proposed design is experimentally verified and also demonstrated in an accompanied video file under different scenarios including network transients, such as grid phase jumps, grid voltage sags and frequency excursions, as well as operational events of power step change and load reduction.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (4) , 4969-4983
Composite Power-Frequency Synchronization Loop for Enhanced Frequency Response Considering Current and Power Limits of Grid-Forming Converters
Grid-forming (GFM) control is a promising solution to provide damping and frequency support services in low-inertia power systems with an increasing share of inverter-based resources. This article investigates the available frequency response services from GFM converters during frequency disturbances, considering the impact of physical limitations of the converter and underlying power source (i.e., current and power ratings). Specifically, current limiters that are used for protection of power semiconductors restrict the achievable output power range of GFM converters and make them susceptible to loss of grid synchronization during large frequency disturbances. The inclusion of power limiters guarantees a stable equilibrium point without exceeding the current limit during disturbances, but negatively impacts frequency stability by reducing the effective damping factor. To address these problems, a composite power-frequency synchronization loop (CPFSL) is proposed as an alternative to the widely adopted power-synchronization loop (PSL). The proposed CPFSL can coordinate with current and power limiters, and enhances the damping factor of GFM converters by incorporating a phase-locked loop-based droop term into the conventional PSL. GFM converters with the CPFSL are capable of providing adaptive frequency response, which fully utilizes the available power headroom of dc-side energy sources, while maintaining grid synchronization during extreme grid events. A comparison with other GFM control methods demonstrates the improved synchronization stability of the CPFSL during severe frequency events. Furthermore, the response of CPFSL-based GFM converters during frequency disturbances, voltage disturbances, and under weak grid and islanded conditions is verified experimentally using a hardware setup of a grid-connected GFM converter.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (4) , 4969-4983
Composite Power-Frequency Synchronization Loop for Enhanced Frequency Response Considering Current and Power Limits of Grid-Forming Converters
Grid-forming (GFM) control is a promising solution to provide damping and frequency support services in low-inertia power systems with an increasing share of inverter-based resources. This article investigates the available frequency response services from GFM converters during frequency disturbances, considering the impact of physical limitations of the converter and underlying power source (i.e., current and power ratings). Specifically, current limiters that are used for protection of power semiconductors restrict the achievable output power range of GFM converters and make them susceptible to loss of grid synchronization during large frequency disturbances. The inclusion of power limiters guarantees a stable equilibrium point without exceeding the current limit during disturbances, but negatively impacts frequency stability by reducing the effective damping factor. To address these problems, a composite power-frequency synchronization loop (CPFSL) is proposed as an alternative to the widely adopted power-synchronization loop (PSL). The proposed CPFSL can coordinate with current and power limiters, and enhances the damping factor of GFM converters by incorporating a phase-locked loop-based droop term into the conventional PSL. GFM converters with the CPFSL are capable of providing adaptive frequency response, which fully utilizes the available power headroom of dc-side energy sources, while maintaining grid synchronization during extreme grid events. A comparison with other GFM control methods demonstrates the improved synchronization stability of the CPFSL during severe frequency events. Furthermore, the response of CPFSL-based GFM converters during frequency disturbances, voltage disturbances, and under weak grid and islanded conditions is verified experimentally using a hardware setup of a grid-connected GFM converter.
- 6 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (5) , 5488-5492
Design of Adaptive Current Limiters in Modular Multilevel Converters
Current limiters in power converters restrict the output current and protect power semiconductors during contingencies. However, such limitation compromises their fault current contribution to power systems. This letter proposes an arm current-based adaptive limiter for modular multilevel converters (MMCs), considering the impact of dc circulating current. The magnitude limit for MMC output current adaptively changes with the voltage at the point of common coupling, to make full use of the current ratings of power semiconductors under both balanced and unbalanced grid conditions. The proposed limiter allows for additional reactive current output during voltage sags and enhances the short-circuit capacity of the MMC. All these capabilities are quantified and validated with experimental results of the low-voltage ride-through performance of a grid connected grid-forming MMC system.
- 6 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (5) , 5488-5492
Design of Adaptive Current Limiters in Modular Multilevel Converters
Current limiters in power converters restrict the output current and protect power semiconductors during contingencies. However, such limitation compromises their fault current contribution to power systems. This letter proposes an arm current-based adaptive limiter for modular multilevel converters (MMCs), considering the impact of dc circulating current. The magnitude limit for MMC output current adaptively changes with the voltage at the point of common coupling, to make full use of the current ratings of power semiconductors under both balanced and unbalanced grid conditions. The proposed limiter allows for additional reactive current output during voltage sags and enhances the short-circuit capacity of the MMC. All these capabilities are quantified and validated with experimental results of the low-voltage ride-through performance of a grid connected grid-forming MMC system.
- 28 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (9) , 10693-10698
Bandwise Power-Synchronization Loop for Frequency Response Improvement in Grid-Forming Converters
Grid-forming (GFM) converters are prone to synchronization instability following large frequency disturbances in the external grid. The power-synchronization loop (PSL) fails to maintain grid synchronization when its droop-based power reference reaches beyond the achievable output power range. In this letter, a bandwise power-synchronization loop (BPSL) is proposed to enhance the frequency response of GFM converters. The damping power, defined as proportional to frequency variation in the PSL, is segmented by a pair of complimentary filters into low-frequency and high-frequency components to coordinate with power-limiting design. During normal operation, the proposed BPSL is equivalent to the PSL. During large disturbances, a power limiter is introduced to act on the low-frequency damping power component to provide droop-based but power-limiting frequency response. The highfrequency damping power component is completely preserved to provide adequate damping in mitigating frequency and power oscillations. Frequency response under different disturbances is verified experimentally using a hardware setup of a gridconnected GFM converter.
- 28 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (9) , 10693-10698
Bandwise Power-Synchronization Loop for Frequency Response Improvement in Grid-Forming Converters
Grid-forming (GFM) converters are prone to synchronization instability following large frequency disturbances in the external grid. The power-synchronization loop (PSL) fails to maintain grid synchronization when its droop-based power reference reaches beyond the achievable output power range. In this letter, a bandwise power-synchronization loop (BPSL) is proposed to enhance the frequency response of GFM converters. The damping power, defined as proportional to frequency variation in the PSL, is segmented by a pair of complimentary filters into low-frequency and high-frequency components to coordinate with power-limiting design. During normal operation, the proposed BPSL is equivalent to the PSL. During large disturbances, a power limiter is introduced to act on the low-frequency damping power component to provide droop-based but power-limiting frequency response. The highfrequency damping power component is completely preserved to provide adequate damping in mitigating frequency and power oscillations. Frequency response under different disturbances is verified experimentally using a hardware setup of a gridconnected GFM converter.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 5271-5285
Current-Synchronization Control of Grid-Forming Converters for Fault Current Limiting and Enhanced Synchronization Stability
Grid-forming (GFM) converters with the widely adopted power-synchronization controller (PSC) are exposed to the risk of losing synchronization, due to their limited power transfer capability under severe symmetrical faults. The output of the PSC, i.e., internal angular frequency, is forced to deviate from its reference, leading to an uncontrollable power angle during the fault. Hence, GFM converters become sensitive to fault depth and duration, suffering from long recovery time. This article proposes a current-limiting GFM control that is capable of limiting fault current and maintaining grid synchronization during severe faults. A current-synchronization controller (CSC) is developed to replace the PSC. The proposed CSC works compatibly with a current limiter and behaves as a PSC during normal conditions to provide synthetic inertia and a phase-locked loop during severe faults with enhanced synchronization stability. Based on the developed steady-state model, it shows that GFM converters under the proposed control directly transition to a faulted steady state when a fault occurs and maintain a constant power angle until the fault is cleared. This helps converters to regain the prefault steady state within a shorter recovery period. The proposed method is validated by a comprehensive comparison with existing current-limiting methods, as well as experimental results under different control parameters, power settings, and system strength.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 5271-5285
Current-Synchronization Control of Grid-Forming Converters for Fault Current Limiting and Enhanced Synchronization Stability
Grid-forming (GFM) converters with the widely adopted power-synchronization controller (PSC) are exposed to the risk of losing synchronization, due to their limited power transfer capability under severe symmetrical faults. The output of the PSC, i.e., internal angular frequency, is forced to deviate from its reference, leading to an uncontrollable power angle during the fault. Hence, GFM converters become sensitive to fault depth and duration, suffering from long recovery time. This article proposes a current-limiting GFM control that is capable of limiting fault current and maintaining grid synchronization during severe faults. A current-synchronization controller (CSC) is developed to replace the PSC. The proposed CSC works compatibly with a current limiter and behaves as a PSC during normal conditions to provide synthetic inertia and a phase-locked loop during severe faults with enhanced synchronization stability. Based on the developed steady-state model, it shows that GFM converters under the proposed control directly transition to a faulted steady state when a fault occurs and maintain a constant power angle until the fault is cleared. This helps converters to regain the prefault steady state within a shorter recovery period. The proposed method is validated by a comprehensive comparison with existing current-limiting methods, as well as experimental results under different control parameters, power settings, and system strength.
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (4) , 3931-3942
Virtual Arm Impedance Emulation and Stability Improvement in Modular Multilevel Converters
The arm impedance in a modular multilevel converter (MMC) influences both the internal dynamics and the converter impedance, significantly impacting the overall system stability. This paper proposes a damping method with virtual arm impedance to suppress the small-signal oscillations caused by impedance interactions and improve the MMC stability. The virtual arm impedance, including both a resistance and a reactance component, is emulated based on the common-mode (CM) second-harmonic circulating current, which is injected to optimize the capacitor voltages of MMCs. Different from existing virtual impedance methods, the steady-state operation of the MMC is not influenced by the CM virtual arm impedance. It is shown that the virtual reactance of the same impedance has a better damping effect, compared with the virtual resistance. Selection guidelines of virtual reactance are also provided considering both the stability margin and dynamic performance. Moreover, the stability improvement is quantified by a stability boundary map and validated by real-time grid interaction studies and experimental results
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (4) , 3931-3942
Virtual Arm Impedance Emulation and Stability Improvement in Modular Multilevel Converters
The arm impedance in a modular multilevel converter (MMC) influences both the internal dynamics and the converter impedance, significantly impacting the overall system stability. This paper proposes a damping method with virtual arm impedance to suppress the small-signal oscillations caused by impedance interactions and improve the MMC stability. The virtual arm impedance, including both a resistance and a reactance component, is emulated based on the common-mode (CM) second-harmonic circulating current, which is injected to optimize the capacitor voltages of MMCs. Different from existing virtual impedance methods, the steady-state operation of the MMC is not influenced by the CM virtual arm impedance. It is shown that the virtual reactance of the same impedance has a better damping effect, compared with the virtual resistance. Selection guidelines of virtual reactance are also provided considering both the stability margin and dynamic performance. Moreover, the stability improvement is quantified by a stability boundary map and validated by real-time grid interaction studies and experimental results
- 3 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (2) , 1100-1109
Small-Signal Stability Enhancement With Circulating Reactive Power in Parallel Modular Multilevel Converters
This paper proposes a small-signal stability enhancement method that leverages the admittance shaping effect of the output power in modular multilevel converters (MMCs). The small-signal oscillations, which are caused by the impedance interactions between MMCs and grids, are suppressed by injected reactive power circulating between parallel MMCs. The reactive power references of both MMCs are modified to enable reactive power circulation without changing the control structures or parameters, which is more feasible for practical applications. The total power supplied to the grid remains the same, maintaining the power flow distribution and the grid bus voltage. The amount and direction of the circulating reactive power are constrained by both system stability margin and MMC capacity. The system stability margin is evaluated based on the phase characteristics of the determinant of bus admittance, which reflect the number and positions of system right-half-plane zeros. The effectiveness of the proposed method is validated by real-time simulation results, which are aligned with the theoretical stability analysis. The proposed method is tailor-made to networks with parallel-connected converters, especially at the bus where multiple inverter-based resources are locally integrated.
- 3 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (2) , 1100-1109
Small-Signal Stability Enhancement With Circulating Reactive Power in Parallel Modular Multilevel Converters
This paper proposes a small-signal stability enhancement method that leverages the admittance shaping effect of the output power in modular multilevel converters (MMCs). The small-signal oscillations, which are caused by the impedance interactions between MMCs and grids, are suppressed by injected reactive power circulating between parallel MMCs. The reactive power references of both MMCs are modified to enable reactive power circulation without changing the control structures or parameters, which is more feasible for practical applications. The total power supplied to the grid remains the same, maintaining the power flow distribution and the grid bus voltage. The amount and direction of the circulating reactive power are constrained by both system stability margin and MMC capacity. The system stability margin is evaluated based on the phase characteristics of the determinant of bus admittance, which reflect the number and positions of system right-half-plane zeros. The effectiveness of the proposed method is validated by real-time simulation results, which are aligned with the theoretical stability analysis. The proposed method is tailor-made to networks with parallel-connected converters, especially at the bus where multiple inverter-based resources are locally integrated.