Martin Hudec
Research Subjects
Martin Hudec has a total of 157 co-authors. Here are the top co-authors by number of shared publications:
- Béla Merkely
Heart and Vascular Centre, Semmelweis University, Budapest, Hungary
3 shared publications - Ashok Thakkar
Department of Clinical Trials, Sahajanand Medical Technologies Pvt. Ltd., Surat, Gujarat 395004, India
2 shared publications Axel Linke
2 shared publications- Borislav Atzev
University Hospital St. Ekaterina, Sofia, Bulgaria
2 shared publications - Borislav Borisov
MBAL St. Ivan Rilski, Bulgaria
2 shared publications - Francesco Bedogni
Department of Cardiology, IRCCS Policlinico San Donato , San Donato Milanese, Milan
2 shared publications
Latest Publications
- 9 September 2026
- Published by Springer Nature in Nature Medicine
- Vol. 32 (9) , 3322-3330
Myeloperoxidase inhibition with mitiperstat in heart failure with preserved or mildly reduced ejection fraction: a randomized phase 2b trial
Myeloperoxidase (MPO)-derived oxidants reduce nitric oxide bioavailability and promote coronary microvascular dysfunction, cardiomyocyte stiffening and interstitial fibrosis—mechanisms implicated in the pathogenesis of heart failure with preserved and mildly reduced ejection fraction. Here, in a multicenter, randomized, double-blind, placebo-controlled, three-arm, parallel-group phase 2b trial of patients with heart failure and an ejection fraction of >40%, we evaluated whether treatment with the MPO inhibitor mitiperstat versus placebo for 48 weeks improved symptoms and exercise function at 16 weeks (the co-primary endpoints were the Kansas City Cardiomyopathy Questionnaire Total Symptom Score (KCCQ-TSS) and 6-minute walk distance (6MWD)). Secondary endpoints included changes in natriuretic peptides and inflammatory markers (up to 48 weeks) and echocardiographic parameters (up to 24 weeks). In total, 711 patients (45% women) were randomized 1:1:1 to mitiperstat 2.5 mg, mitiperstat 5 mg or placebo. Mitiperstat (pooled doses) did not improve KCCQ-TSS (placebo-corrected difference in mean change from baseline, –1.4 points (95% confidence interval (CI) –3.9, 1.2; P = 0.29), 6MWD (3.8 m (95% CI –3.1, 10.8)); P = 0.28) or any secondary endpoint. Adverse and serious adverse events, including infections, were similar among groups except for maculopapular rash (mitiperstat, 3.6%; placebo, 0.4%). These results indicate that mitiperstat was safe and well tolerated but did not improve symptoms or exercise function in chronic heart failure with preserved or mildly reduced ejection fraction. ClinicalTrials.gov registration: NCT04986202.
- 9 September 2026
- Published by Springer Nature in Nature Medicine
- Vol. 32 (9) , 3322-3330
Myeloperoxidase inhibition with mitiperstat in heart failure with preserved or mildly reduced ejection fraction: a randomized phase 2b trial
Myeloperoxidase (MPO)-derived oxidants reduce nitric oxide bioavailability and promote coronary microvascular dysfunction, cardiomyocyte stiffening and interstitial fibrosis—mechanisms implicated in the pathogenesis of heart failure with preserved and mildly reduced ejection fraction. Here, in a multicenter, randomized, double-blind, placebo-controlled, three-arm, parallel-group phase 2b trial of patients with heart failure and an ejection fraction of >40%, we evaluated whether treatment with the MPO inhibitor mitiperstat versus placebo for 48 weeks improved symptoms and exercise function at 16 weeks (the co-primary endpoints were the Kansas City Cardiomyopathy Questionnaire Total Symptom Score (KCCQ-TSS) and 6-minute walk distance (6MWD)). Secondary endpoints included changes in natriuretic peptides and inflammatory markers (up to 48 weeks) and echocardiographic parameters (up to 24 weeks). In total, 711 patients (45% women) were randomized 1:1:1 to mitiperstat 2.5 mg, mitiperstat 5 mg or placebo. Mitiperstat (pooled doses) did not improve KCCQ-TSS (placebo-corrected difference in mean change from baseline, –1.4 points (95% confidence interval (CI) –3.9, 1.2; P = 0.29), 6MWD (3.8 m (95% CI –3.1, 10.8)); P = 0.28) or any secondary endpoint. Adverse and serious adverse events, including infections, were similar among groups except for maculopapular rash (mitiperstat, 3.6%; placebo, 0.4%). These results indicate that mitiperstat was safe and well tolerated but did not improve symptoms or exercise function in chronic heart failure with preserved or mildly reduced ejection fraction. ClinicalTrials.gov registration: NCT04986202.
- Open Access
- 24 July 2026
- Published by Elsevier in Structural Heart
- Vol. 10 (9)
Impact of Early Nonfatal Complications After Transcatheter Aortic Valve Implantation on 1-Year Mortality and Quality of Life: Insights From the LANDMARK Trial
- 24 July 2026
- Published by Elsevier in Structural Heart
- Vol. 10 (9)
Open AccessImpact of Early Nonfatal Complications After Transcatheter Aortic Valve Implantation on 1-Year Mortality and Quality of Life: Insights From the LANDMARK Trial
- Open Access
- 28 August 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 27 (2) , 247-260
Comparative 30-day echocardiographic outcomes of Myval vs. Sapien and Evolut THVs: insights from LANDMARK trial
Aims: Several factors, including device design, annulus size, and sizing strategies, influence transcatheter heart valve (THV) haemodynamic outcomes in patients with aortic stenosis (AS). This sub-study evaluates early (30-day) echocardiographic outcomes of the Myval, Sapien, and Evolut THV series, focusing on haemodynamic performance and valve durability. Methods and results: The LANDMARK trial is a prospective, randomised, multicentre, open-label, non-inferiority trial comparing 384 patients implanted with Myval THV series to 384 receiving Sapien and Evolut THV series. Haemodynamic assessments followed Valve Academic Research Consortium-3 recommendations. At 30-day, haemodynamic device success rates were 85.9%, 77.8, and 85.4% for Myval, Sapien, and Evolut THV series, respectively (PMyval-Sapien = 0.03 and PMyval-Evolut = 0.98). Significant improvements in peak aortic flow velocity, pressure gradients, effective orifice area (EOA), Doppler velocity index (DVI), and cardiac indices were observed across all groups, except for unchanged left ventricular ejection fraction. Moderate prosthesis-patient mismatch (PPM) was less frequent with Myval THV series(11.3%) vs. Sapien THV series(21.8%), but higher than Evolut THV series (5.3%) (PMyval-Sapien = 0.0024, PMyval-Evolut = 0.0396), while severe PPM showed no significant differences (4.2% vs. 6.3% vs. 1.8%; PMyval-Sapien = 0.394, PMyval-Evolut = 0.2438). Rates of ≥ moderate paravalvular leak (PVL) were lower in Myval (3.5%), and Sapien (1.7%) compared with Evolut THV series (8.3%) (PMyval-Sapien = 0.3769, PMyval-Evolut = 0.0336). Myval THV series required minimal oversizing compared with Evolut THV series (P < 0.0001). Conclusion: The Myval THV series demonstrates short-term haemodynamic performance comparable to Evolut THV series and superior to Sapien THV series. Including intermediate sizes minimizes oversizing, underscoring its potential as an alternative for TAVI patients. Long-term follow-up is necessary to confirm these findings. Clinical trial registration: ClinicalTrials.gov: NCT04275726, EudraCT number 2020-000,137-40
- 28 August 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 27 (2) , 247-260
Open AccessComparative 30-day echocardiographic outcomes of Myval vs. Sapien and Evolut THVs: insights from LANDMARK trial
Aims: Several factors, including device design, annulus size, and sizing strategies, influence transcatheter heart valve (THV) haemodynamic outcomes in patients with aortic stenosis (AS). This sub-study evaluates early (30-day) echocardiographic outcomes of the Myval, Sapien, and Evolut THV series, focusing on haemodynamic performance and valve durability. Methods and results: The LANDMARK trial is a prospective, randomised, multicentre, open-label, non-inferiority trial comparing 384 patients implanted with Myval THV series to 384 receiving Sapien and Evolut THV series. Haemodynamic assessments followed Valve Academic Research Consortium-3 recommendations. At 30-day, haemodynamic device success rates were 85.9%, 77.8, and 85.4% for Myval, Sapien, and Evolut THV series, respectively (PMyval-Sapien = 0.03 and PMyval-Evolut = 0.98). Significant improvements in peak aortic flow velocity, pressure gradients, effective orifice area (EOA), Doppler velocity index (DVI), and cardiac indices were observed across all groups, except for unchanged left ventricular ejection fraction. Moderate prosthesis-patient mismatch (PPM) was less frequent with Myval THV series(11.3%) vs. Sapien THV series(21.8%), but higher than Evolut THV series (5.3%) (PMyval-Sapien = 0.0024, PMyval-Evolut = 0.0396), while severe PPM showed no significant differences (4.2% vs. 6.3% vs. 1.8%; PMyval-Sapien = 0.394, PMyval-Evolut = 0.2438). Rates of ≥ moderate paravalvular leak (PVL) were lower in Myval (3.5%), and Sapien (1.7%) compared with Evolut THV series (8.3%) (PMyval-Sapien = 0.3769, PMyval-Evolut = 0.0336). Myval THV series required minimal oversizing compared with Evolut THV series (P < 0.0001). Conclusion: The Myval THV series demonstrates short-term haemodynamic performance comparable to Evolut THV series and superior to Sapien THV series. Including intermediate sizes minimizes oversizing, underscoring its potential as an alternative for TAVI patients. Long-term follow-up is necessary to confirm these findings. Clinical trial registration: ClinicalTrials.gov: NCT04275726, EudraCT number 2020-000,137-40
- Open Access
- 1 December 2024
- Published by Elmer Press, Inc. in Cardiology Research
- Vol. 15 (6) , 439-452
Safety and Efficacy of BioMime Sirolimus-Eluting Stent System in All-Comers Real-World Population With Coronary Artery Stenosis: MILES Global Registry
This study evaluated the safety and efficacy of BioMime sirolimus-eluting stent (SES) system, with an ultra-low strut thickness (65 µm), in real-world all-comers population with coronary artery stenosis (CAD). This was a post-marketing, multicenter, single-arm, observational clinical registry among patients undergoing intervention for CAD. Patients were clinically followed up at 1, 9, 12, and 24 months after the index percutaneous coronary intervention. Four major indications, namely long stents of > 30 mm, stents with diameters of 4 and 4.5 mm, bifurcation subgroup, and chronic total occlusion (CTO) were evaluated as pre-specified subsets. A total of 771 patients (1,079 treated lesions) from 23 sites were included in this study. The mean length and diameter of the implanted stents were 25.57 ± 9.35 mm and 3.00 ± 0.44 mm, respectively. The mean minimum lumen diameter before and after the procedure was 1.00 ± 1.69 mm and 2.96 ± 1.35 mm, respectively. The cumulative rates of major adverse cardiovascular events (MACEs) and stent thrombosis (ST) at 1, 9, 12, and 24 months were 1.05%, 3.13%, 4.04%, 5.64% and 0%, 0.13%, 0.28%, 0.28%, respectively. In a subset with > 30 mm long stents, the cumulative rate of MACEs was 0.4%, 4.6%, 5.12%, and 7.01% at 1, 9, 12, and 24 months, respectively. The corresponding rates of ST were 0%, 0.42%, 0.43%, and 0.44%, indicating constant rate of ST after 9 months. In a subset of 4 and 4.5 mm diameter stents, the cumulative rate of MACEs was high (0%, 6.25%, 6.25%, and 10.41%) at 1, 9, 12, and 24 months, respectively. However, there was no case of ST until 24 months. In patients with bifurcation lesions, the cumulative rates of MACEs and ST were 2.46%, 6.32%, 11.53%, 16.21% and 0%, 1.27%, 1.28%, 1.35% at 1, 9, 12, and 24 months follow-up. In patients with chronic total occlusion, the cumulative rates of MACEs and ST were 0.79%, 5.04%, 6.83%, 7.07% and 0%, 0.84%, 0.85%, 0.88% at 1, 9, 12, and 24 months, respectively, indicating constant rate of ST after 9 months. The BioMime SES demonstrated good safety and efficacy outcomes at 24-month follow-up, with low rates of MACEs and ST in patients with CAD in the real-world setting.
- 1 December 2024
- Published by Elmer Press, Inc. in Cardiology Research
- Vol. 15 (6) , 439-452
Open AccessSafety and Efficacy of BioMime Sirolimus-Eluting Stent System in All-Comers Real-World Population With Coronary Artery Stenosis: MILES Global Registry
This study evaluated the safety and efficacy of BioMime sirolimus-eluting stent (SES) system, with an ultra-low strut thickness (65 µm), in real-world all-comers population with coronary artery stenosis (CAD). This was a post-marketing, multicenter, single-arm, observational clinical registry among patients undergoing intervention for CAD. Patients were clinically followed up at 1, 9, 12, and 24 months after the index percutaneous coronary intervention. Four major indications, namely long stents of > 30 mm, stents with diameters of 4 and 4.5 mm, bifurcation subgroup, and chronic total occlusion (CTO) were evaluated as pre-specified subsets. A total of 771 patients (1,079 treated lesions) from 23 sites were included in this study. The mean length and diameter of the implanted stents were 25.57 ± 9.35 mm and 3.00 ± 0.44 mm, respectively. The mean minimum lumen diameter before and after the procedure was 1.00 ± 1.69 mm and 2.96 ± 1.35 mm, respectively. The cumulative rates of major adverse cardiovascular events (MACEs) and stent thrombosis (ST) at 1, 9, 12, and 24 months were 1.05%, 3.13%, 4.04%, 5.64% and 0%, 0.13%, 0.28%, 0.28%, respectively. In a subset with > 30 mm long stents, the cumulative rate of MACEs was 0.4%, 4.6%, 5.12%, and 7.01% at 1, 9, 12, and 24 months, respectively. The corresponding rates of ST were 0%, 0.42%, 0.43%, and 0.44%, indicating constant rate of ST after 9 months. In a subset of 4 and 4.5 mm diameter stents, the cumulative rate of MACEs was high (0%, 6.25%, 6.25%, and 10.41%) at 1, 9, 12, and 24 months, respectively. However, there was no case of ST until 24 months. In patients with bifurcation lesions, the cumulative rates of MACEs and ST were 2.46%, 6.32%, 11.53%, 16.21% and 0%, 1.27%, 1.28%, 1.35% at 1, 9, 12, and 24 months follow-up. In patients with chronic total occlusion, the cumulative rates of MACEs and ST were 0.79%, 5.04%, 6.83%, 7.07% and 0%, 0.84%, 0.85%, 0.88% at 1, 9, 12, and 24 months, respectively, indicating constant rate of ST after 9 months. The BioMime SES demonstrated good safety and efficacy outcomes at 24-month follow-up, with low rates of MACEs and ST in patients with CAD in the real-world setting.
- Open Access
- 1 January 2024
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 28 (3) , 142-149
Evaluation of Ultrathin Strut Biodegradable Polymer-Coated Sirolimus-Eluting Stents in an All-Comers Patient Population: 1-Year Results of the S-FLEX Slovakia Registry
Background: Supraflex (Sahajanand Medical Technologies Limited, Surat, India) is a newgeneration, biodegradable polymer -coated sirolimus-eluting stent (SES) designed on an ultrathin (60 mu m) cobalt-chromium platform with a flexible "S -link." The S -FLEX Slovakia registry aimed to assess the safety and effectiveness of Supraflex SES in an all -comers population, with a subgroup of diabetic patients. Methods: This was a prospective, observational, multi -center, post -market registry conducted between February 2018 and May 2019. All consecutive patients with symp- tomatic coronary artery disease scheduled for percutaneous coronary intervention with Supraflex SES were enrolled. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiac death, target vessel myocardial infarction (TV -MI), or clinically indicated target lesion revascularization (CI-TLR) by percutaneous or surgical methods at 1 -year follow-up. Stent thrombosis was a safety endpoint. Results: A total of 413 patients was assessed (145 diabetics and 268 nondiabetics). At 1 -year follow-up, the primary endpoint of TLF occurred in 5.1% patients, comprised of 3.9% cardiac deaths, 0.5% TV -MI, and 0.7% CI-TLR. Overall stent thrombosis occurred in 0.5% patients at 1 -year follow-up. In the subgroup analysis, TLF occurred in 6.2% diabetics and 4.5% nondiabetics (P = .433) and comprised 4.8% and 3.4% cardiac deaths (P = .447), 0.7% and 0.4% TV -MI (P = .653), and 0.7%, and 0.7% CI-TLR (P = .952) in diabetics and nondiabetics, respectively. Overall stent thrombosis occurred in 0.7% diabetic and 0.4% nondiabetic patient (P = .659). Conclusion: This registry demonstrates favourable clinical outcomes after the implanta- tion of the ultrathin biodegradable polymer coated Supraflex SES in an all -comers popu- lation, with event rates that were similar in diabetic and nondiabetic patients.
- 1 January 2024
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 28 (3) , 142-149
Open AccessEvaluation of Ultrathin Strut Biodegradable Polymer-Coated Sirolimus-Eluting Stents in an All-Comers Patient Population: 1-Year Results of the S-FLEX Slovakia Registry
Background: Supraflex (Sahajanand Medical Technologies Limited, Surat, India) is a newgeneration, biodegradable polymer -coated sirolimus-eluting stent (SES) designed on an ultrathin (60 mu m) cobalt-chromium platform with a flexible "S -link." The S -FLEX Slovakia registry aimed to assess the safety and effectiveness of Supraflex SES in an all -comers population, with a subgroup of diabetic patients. Methods: This was a prospective, observational, multi -center, post -market registry conducted between February 2018 and May 2019. All consecutive patients with symp- tomatic coronary artery disease scheduled for percutaneous coronary intervention with Supraflex SES were enrolled. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiac death, target vessel myocardial infarction (TV -MI), or clinically indicated target lesion revascularization (CI-TLR) by percutaneous or surgical methods at 1 -year follow-up. Stent thrombosis was a safety endpoint. Results: A total of 413 patients was assessed (145 diabetics and 268 nondiabetics). At 1 -year follow-up, the primary endpoint of TLF occurred in 5.1% patients, comprised of 3.9% cardiac deaths, 0.5% TV -MI, and 0.7% CI-TLR. Overall stent thrombosis occurred in 0.5% patients at 1 -year follow-up. In the subgroup analysis, TLF occurred in 6.2% diabetics and 4.5% nondiabetics (P = .433) and comprised 4.8% and 3.4% cardiac deaths (P = .447), 0.7% and 0.4% TV -MI (P = .653), and 0.7%, and 0.7% CI-TLR (P = .952) in diabetics and nondiabetics, respectively. Overall stent thrombosis occurred in 0.7% diabetic and 0.4% nondiabetic patient (P = .659). Conclusion: This registry demonstrates favourable clinical outcomes after the implanta- tion of the ultrathin biodegradable polymer coated Supraflex SES in an all -comers popu- lation, with event rates that were similar in diabetic and nondiabetic patients.
- Open Access
- 1 December 2020
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 31, 100605
1-Year COMBO stent outcomes stratified by the PARIS bleeding prediction score: From the MASCOT registry
- 1 December 2020
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 31, 100605
Open Access1-Year COMBO stent outcomes stratified by the PARIS bleeding prediction score: From the MASCOT registry