Cong Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cong Liu has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Xingyi Zhang
Key Laboratory of Mechanics on Disaster and Environment in Western China Attached to the Ministry of Education of China, Lanzhou University, Lanzhou, China
23 shared publications Jun Zhou
Key Laboratory of Mechanics on Disaster and Environment in Western China Attached to the Ministry of Education of China, Lanzhou University, Lanzhou, China
8 shared publicationsYou-He Zhou
Key Laboratory of Mechanics On Disaster and Environment in Western China Attached To the Ministry of Education of China, Lanzhou University, Lanzhou, PR China
6 shared publicationsYouhe Zhou
Key Laboratory of Mechanics on Disaster and Environment in Western China, The Ministry of Education of China, Lanzhou University 1 , Lanzhou, Gansu 730000, China
6 shared publicationsXingyi Zhang
4 shared publicationsNana Mu
Key Laboratory of Mechanics on Disaster and Environment in Western China Attached to the Ministry of Education of China, Lanzhou University, Lanzhou, China
3 shared publications
Latest Publications
- Open Access
- 24 September 2026
- Published by Springer Nature in Communications Engineering
Applied current induced degradation of delamination strength of coated conductors and microscopic mechanism revelation
Coated conductors in superconducting coils experience transverse stresses caused by thermal stress and large electromechanical forces during operation, which risk the coated conductors’ delamination due to their multilayer structure. However, the mechanical–electrical coupling between the transverse stresses and applied currents involved during delamination remains insufficiently clarified. Focusing on this issue, here we conducted an experimental investigation on the delamination behavior of coated conductors when carrying superconducting currents. Through the simultaneous measurements of voltage and force signals during the delamination, we found with the increased applied current the correlation coefficient between the two increment variables elevated, however, statistical delamination strength from Weibull distribution showed a significant decreased behavior. Magneto-optical imaging on the delaminated surface of the sample indicated a mixing fracture model of superconducting layers. Further microscopy results demonstrated BaCeO 3 as dendritic structure generated at the delamination sites of samples with low delamination strength. It was thought the thermal stress caused by local quenching and the lattice mismatch between the BaCeO 3 and YBa 2 Cu 3 O 7-δ are the two fundamental reasons for the degraded statistical delamination strength. These findings indicate that the effect of applied current should be considered when establishing stress management criteria for REBCO coated conductors in superconducting magnets.
- 24 September 2026
- Published by Springer Nature in Communications Engineering
Open AccessApplied current induced degradation of delamination strength of coated conductors and microscopic mechanism revelation
Coated conductors in superconducting coils experience transverse stresses caused by thermal stress and large electromechanical forces during operation, which risk the coated conductors’ delamination due to their multilayer structure. However, the mechanical–electrical coupling between the transverse stresses and applied currents involved during delamination remains insufficiently clarified. Focusing on this issue, here we conducted an experimental investigation on the delamination behavior of coated conductors when carrying superconducting currents. Through the simultaneous measurements of voltage and force signals during the delamination, we found with the increased applied current the correlation coefficient between the two increment variables elevated, however, statistical delamination strength from Weibull distribution showed a significant decreased behavior. Magneto-optical imaging on the delaminated surface of the sample indicated a mixing fracture model of superconducting layers. Further microscopy results demonstrated BaCeO 3 as dendritic structure generated at the delamination sites of samples with low delamination strength. It was thought the thermal stress caused by local quenching and the lattice mismatch between the BaCeO 3 and YBa 2 Cu 3 O 7-δ are the two fundamental reasons for the degraded statistical delamination strength. These findings indicate that the effect of applied current should be considered when establishing stress management criteria for REBCO coated conductors in superconducting magnets.
- Open Access
- 11 October 2025
- Published by Elsevier in Theoretical and Applied Mechanics Letters
- Vol. 16 (2)
Electromechanical models for the critical current degradation behavior of coated conductors wound on round cores
- 11 October 2025
- Published by Elsevier in Theoretical and Applied Mechanics Letters
- Vol. 16 (2)
Open AccessElectromechanical models for the critical current degradation behavior of coated conductors wound on round cores
- 9 May 2025
- Published by Springer Nature in Experimental Mechanics
- Vol. 65 (6) , 981-989
Thermal Expansion Coefficient Measurement of Stack Structure of REBCO Coated Conductors By Strain Gages At Cryogenic Temperatures
- 9 May 2025
- Published by Springer Nature in Experimental Mechanics
- Vol. 65 (6) , 981-989
Thermal Expansion Coefficient Measurement of Stack Structure of REBCO Coated Conductors By Strain Gages At Cryogenic Temperatures
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
Effects of copper former on the DC and AC transmission losses for conductor on round core cables
Conductor on round core (CORC) cables have become one of the most promising superconducting cables for power applications. AC loss is a crucial parameter in determining cryogenic maintenance costs. In this work, CORC cable models were built, and the effects of copper formers with different wall thicknesses on the critical current measurements and AC transition loss were studied. It was found that the voltage on the copper former emerged when the total applied currents were below the critical current, Ic, of the cable sample, causing a DC loss as high as 3.3 mW/cm within the former for the original cable samples. An improved approach by secondary soldering is proposed to eliminate voltage in the copper former for the reason that the secondary-soldering reduced contact resistance, thereby facilitating the current transfer from the former to CCs. AC loss of copper formers shows highly frequency dependent behavior with increased wall thickness because of the skin effect. Experimental results demonstrate that the AC losses of CORC cable samples with copper formers of different wall thicknesses are all frequency dependent. The AC loss of the sample with a copper bar is larger than that with a copper tube of the same diameter at low frequencies, while the contrary behavior is observed at high frequencies, suggesting copper tubes as former cores are good for CORC cables to reduce the AC loss at low frequencies.
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
Effects of copper former on the DC and AC transmission losses for conductor on round core cables
Conductor on round core (CORC) cables have become one of the most promising superconducting cables for power applications. AC loss is a crucial parameter in determining cryogenic maintenance costs. In this work, CORC cable models were built, and the effects of copper formers with different wall thicknesses on the critical current measurements and AC transition loss were studied. It was found that the voltage on the copper former emerged when the total applied currents were below the critical current, Ic, of the cable sample, causing a DC loss as high as 3.3 mW/cm within the former for the original cable samples. An improved approach by secondary soldering is proposed to eliminate voltage in the copper former for the reason that the secondary-soldering reduced contact resistance, thereby facilitating the current transfer from the former to CCs. AC loss of copper formers shows highly frequency dependent behavior with increased wall thickness because of the skin effect. Experimental results demonstrate that the AC losses of CORC cable samples with copper formers of different wall thicknesses are all frequency dependent. The AC loss of the sample with a copper bar is larger than that with a copper tube of the same diameter at low frequencies, while the contrary behavior is observed at high frequencies, suggesting copper tubes as former cores are good for CORC cables to reduce the AC loss at low frequencies.
- 18 November 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (23) , 6601-6604
Practical magneto-optical imaging of the current density of coated conductors within liquid nitrogen
Magneto-optical imaging (MOI) is widely used for magnetic studies of superconducting materials due to its advantages of full-field, real-time operation and high resolution. However, a traditional MOI system requires vacuum pumping, thermal shielding, and cooling by thermal conducting, thereby making the system very complex and expensive and increasing the time required to complete a set of experiments. In this study, a novel (to our knowledge) and practical approach for MOI within liquid nitrogen (LN) is proposed in which thermal conducting, thermal shielding, and vacuum pumping are no longer necessary. The key technique is realized through a semi-immersed polymethyl methacrylate (PMMA) bar in LN, and its size is optimized to ensure a stable temperature difference and polarized optical visualization within LN. With the improvised method, a defect in a superconducting layer of length approximately 250 µm in the coated conductor (CC) sample was detected. Additionally, the current density reduced by approximately 50% in magnitude compared to its neighbor region, thus demonstrating the effectiveness of the new approach. It is expected that this technique can further enhance the application of MOI as an efficient tool for industrial inspection of superconducting CCs.
- 18 November 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (23) , 6601-6604
Practical magneto-optical imaging of the current density of coated conductors within liquid nitrogen
Magneto-optical imaging (MOI) is widely used for magnetic studies of superconducting materials due to its advantages of full-field, real-time operation and high resolution. However, a traditional MOI system requires vacuum pumping, thermal shielding, and cooling by thermal conducting, thereby making the system very complex and expensive and increasing the time required to complete a set of experiments. In this study, a novel (to our knowledge) and practical approach for MOI within liquid nitrogen (LN) is proposed in which thermal conducting, thermal shielding, and vacuum pumping are no longer necessary. The key technique is realized through a semi-immersed polymethyl methacrylate (PMMA) bar in LN, and its size is optimized to ensure a stable temperature difference and polarized optical visualization within LN. With the improvised method, a defect in a superconducting layer of length approximately 250 µm in the coated conductor (CC) sample was detected. Additionally, the current density reduced by approximately 50% in magnitude compared to its neighbor region, thus demonstrating the effectiveness of the new approach. It is expected that this technique can further enhance the application of MOI as an efficient tool for industrial inspection of superconducting CCs.
- Open Access
- 15 May 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (19)
A phase-error immune approach for measuring transport AC loss by determination of minimum compensated voltage
Alternating current (AC) loss measurement is crucial for the theoretical evaluation and optimization in the fabrication of superconducting AC devices. Lock-in amplifier based on the lock-in phase is commonly adopted and inevitably involves with phase error. In this work, a novel approach for measuring transport AC loss by determining the minimum compensated voltage (MCV) was developed, in which the lock-in amplifier was removed. Since it just uses the voltage signal from an AC voltmeter, it is phase-error immune. Experimental results demonstrated that when using the lock-in amplifier, there existed a system error as the initial phase difference between the sampled (reference) and real current phases, which required careful compensation. In contrast, the phase error no longer needed to be considered by the MCV method, and the AC loss results were obtained much more conveniently with the relative error between the theoretical and the experimental of less than 5%. Finally, the AC loss of a coated conductor spiral wound on an epoxy bar was obtained using the presented approach, demonstrating its low cost, ease of operation, and high accuracy.
- 15 May 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (19)
Open AccessA phase-error immune approach for measuring transport AC loss by determination of minimum compensated voltage
Alternating current (AC) loss measurement is crucial for the theoretical evaluation and optimization in the fabrication of superconducting AC devices. Lock-in amplifier based on the lock-in phase is commonly adopted and inevitably involves with phase error. In this work, a novel approach for measuring transport AC loss by determining the minimum compensated voltage (MCV) was developed, in which the lock-in amplifier was removed. Since it just uses the voltage signal from an AC voltmeter, it is phase-error immune. Experimental results demonstrated that when using the lock-in amplifier, there existed a system error as the initial phase difference between the sampled (reference) and real current phases, which required careful compensation. In contrast, the phase error no longer needed to be considered by the MCV method, and the AC loss results were obtained much more conveniently with the relative error between the theoretical and the experimental of less than 5%. Finally, the AC loss of a coated conductor spiral wound on an epoxy bar was obtained using the presented approach, demonstrating its low cost, ease of operation, and high accuracy.
- 22 December 2023
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 37 (2) , 025001
A protocol for mapping transport current density of REBCO-coated conductor by magneto-optical imaging
The measurement of transport current density is significant for investigations on improving the properties of REBa2Cu3O7−x (REBCO, where RE refers to rare-earth elements)-coated conductors (CCs). In this work, a protocol for mapping the transport current density of CC by magneto-optical imaging (MOI) is presented. A calibration method is developed based on the non-linear physical governing function for the MOI indicator, in which only two parameters are determined, i.e. the anisotropic magnetic field BA , and cMs , which is the multiplication of the constant c related to the thickness of the MOI indicator and the spontaneous magnetization Ms . The experimental results also showed that they were independent of the optical measure condition but dependent on temperature, making this calibration method comparative among different utilizers. The numerical results clearly manifested that the selected window size of the magnetic field around a long superconducting tape is closely related to the error of the reconstructed current density. A large window size of the magnetic field is needed to precisely reconstruct the transport current density. For actual MOI testing, a practical approach to extend the magnetic field data outside the MOI window was realized by fitting with a power function according to Ampere’s law, through which the false current density outside the sample is automatically suppressed to a large extent. On this basis, the mapping of the transport current density in the CC sample was achieved. It is believed that this work will improve MOI for a more precise measurement of the transport current density for long superconducting strips.
- 22 December 2023
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 37 (2) , 025001
A protocol for mapping transport current density of REBCO-coated conductor by magneto-optical imaging
The measurement of transport current density is significant for investigations on improving the properties of REBa2Cu3O7−x (REBCO, where RE refers to rare-earth elements)-coated conductors (CCs). In this work, a protocol for mapping the transport current density of CC by magneto-optical imaging (MOI) is presented. A calibration method is developed based on the non-linear physical governing function for the MOI indicator, in which only two parameters are determined, i.e. the anisotropic magnetic field BA , and cMs , which is the multiplication of the constant c related to the thickness of the MOI indicator and the spontaneous magnetization Ms . The experimental results also showed that they were independent of the optical measure condition but dependent on temperature, making this calibration method comparative among different utilizers. The numerical results clearly manifested that the selected window size of the magnetic field around a long superconducting tape is closely related to the error of the reconstructed current density. A large window size of the magnetic field is needed to precisely reconstruct the transport current density. For actual MOI testing, a practical approach to extend the magnetic field data outside the MOI window was realized by fitting with a power function according to Ampere’s law, through which the false current density outside the sample is automatically suppressed to a large extent. On this basis, the mapping of the transport current density in the CC sample was achieved. It is believed that this work will improve MOI for a more precise measurement of the transport current density for long superconducting strips.
- 27 July 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (8) , 085949
National round robin test (RRT) for delamination strength testing YBCO HTS wires at room temperature (RT) and 77K
Second generation high temperature superconducting coated conductors (2G HTS CCs) have become indispensable wires for high-field superconducting magnets. The transverse mechanical delamination strength (MDS) is a key parameter due to the multilayer structure of CCs. Determination of the MDS value is thus significant. In this study, we report the MDS results of national round robin test (RRT) conducted in china by the institutions of Lanzhou University, Institute of Plasma Physic, and Shanghai Superconductor Technology Co., Ltd at room temperature (RT) and 77 K, respectively, for the determination of 2G HTS CCs (copper-stabilized) transverse MDS by a standardized procedure. Data at RT and 77 K all showed good consistency, with the relative standard uncertainty of 2.22% and 2.35%, respectively, illustrating the reliability of the established procedure, which can be used as a reference for engineering CC manufacturing and design of application magnets.
- 27 July 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (8) , 085949
National round robin test (RRT) for delamination strength testing YBCO HTS wires at room temperature (RT) and 77K
Second generation high temperature superconducting coated conductors (2G HTS CCs) have become indispensable wires for high-field superconducting magnets. The transverse mechanical delamination strength (MDS) is a key parameter due to the multilayer structure of CCs. Determination of the MDS value is thus significant. In this study, we report the MDS results of national round robin test (RRT) conducted in china by the institutions of Lanzhou University, Institute of Plasma Physic, and Shanghai Superconductor Technology Co., Ltd at room temperature (RT) and 77 K, respectively, for the determination of 2G HTS CCs (copper-stabilized) transverse MDS by a standardized procedure. Data at RT and 77 K all showed good consistency, with the relative standard uncertainty of 2.22% and 2.35%, respectively, illustrating the reliability of the established procedure, which can be used as a reference for engineering CC manufacturing and design of application magnets.
- 26 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (5) , 1-4
Key Issues for Measuring the Electromechanical Properties of 2G HTS Coated Conductors
It is significant to investigate the electromechanical properties of second-generation high-temperature superconducting (HTS) coated conductors (CCs). Generally, a four-probe method, with which voltage taps are soldered on the sample, is used to measure the critical current during tension. However, shear stress occurs at the position near the voltage solder joints when the HTS CCs are tensioned, which can only withstand the shear stress of less than 10 MPa and induce reversible strain less than that without solder joints. In this article, a critical current measurement method in which the voltage taps are not soldered on the surface of the HTS CCs is proposed to avoid the effect of voltage solder joints on HTS CCs. The minimum distance between the insulator and the voltage taps is 6 cm when the HTS CC and the voltage taps are soldered on a Cu plate, through which the reliable measurement results of the strain dependence of critical current and irreversible strain of the HTS CCs are obtained.
- 26 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (5) , 1-4
Key Issues for Measuring the Electromechanical Properties of 2G HTS Coated Conductors
It is significant to investigate the electromechanical properties of second-generation high-temperature superconducting (HTS) coated conductors (CCs). Generally, a four-probe method, with which voltage taps are soldered on the sample, is used to measure the critical current during tension. However, shear stress occurs at the position near the voltage solder joints when the HTS CCs are tensioned, which can only withstand the shear stress of less than 10 MPa and induce reversible strain less than that without solder joints. In this article, a critical current measurement method in which the voltage taps are not soldered on the surface of the HTS CCs is proposed to avoid the effect of voltage solder joints on HTS CCs. The minimum distance between the insulator and the voltage taps is 6 cm when the HTS CC and the voltage taps are soldered on a Cu plate, through which the reliable measurement results of the strain dependence of critical current and irreversible strain of the HTS CCs are obtained.
- 25 November 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 35 (1) , 015003
Controllable rectification on the irreversible strain limit of 2G HTS coated conductors
The second generation high-temperature superconducting coated conductors (CCs) have excellent electrical and mechanical properties, and are extensively used in superconducting devices such as fault current limiters, magnets and motors. During the operation of these superconducting devices, superconducting CCs inevitably bear the combination of electromagnetic force and thermal mismatch stress, resulting in straining of YBa2Cu3O7− δ (YBCO) layer along the tape length. It is well known that the strains of superconducting CCs cause degradation of critical current (I c). Generally, the irreversible strain limit ( ε irr ) is used to characterize the phenomenon that I c of superconducting CCs degrades with axial strain. When the axial strain of superconducting CCs is less than ε irr , I c can be reversibly recovered by over 99% after being unloaded. Therefore, ε irr is a key parameter for the design and application of superconducting CC devices. For this reason, to carry out a practical engineering method for improving ε irr of superconducting CCs has become a challenge and aroused interests among researchers. This study is based on the idea of precompression. A 316LN stainless steel tape was pretensioned at 77 K to improve its elastic strain limit. Then, two superconducting CCs were soldered onto both surfaces of pretensioned stainless steel tape respectively. As a result, ε irr of the superconducting CCs can be controlled manually with different precompressions. Taking YBCO CCs produced by SuperPower Inc. as an example, the measurement results show that the ε irr of the YBCO CCs increased from 0.39% to 0.73%. Meanwhile, the thickness of the sample did not increase more than once.
- 25 November 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 35 (1) , 015003
Controllable rectification on the irreversible strain limit of 2G HTS coated conductors
The second generation high-temperature superconducting coated conductors (CCs) have excellent electrical and mechanical properties, and are extensively used in superconducting devices such as fault current limiters, magnets and motors. During the operation of these superconducting devices, superconducting CCs inevitably bear the combination of electromagnetic force and thermal mismatch stress, resulting in straining of YBa2Cu3O7− δ (YBCO) layer along the tape length. It is well known that the strains of superconducting CCs cause degradation of critical current (I c). Generally, the irreversible strain limit ( ε irr ) is used to characterize the phenomenon that I c of superconducting CCs degrades with axial strain. When the axial strain of superconducting CCs is less than ε irr , I c can be reversibly recovered by over 99% after being unloaded. Therefore, ε irr is a key parameter for the design and application of superconducting CC devices. For this reason, to carry out a practical engineering method for improving ε irr of superconducting CCs has become a challenge and aroused interests among researchers. This study is based on the idea of precompression. A 316LN stainless steel tape was pretensioned at 77 K to improve its elastic strain limit. Then, two superconducting CCs were soldered onto both surfaces of pretensioned stainless steel tape respectively. As a result, ε irr of the superconducting CCs can be controlled manually with different precompressions. Taking YBCO CCs produced by SuperPower Inc. as an example, the measurement results show that the ε irr of the YBCO CCs increased from 0.39% to 0.73%. Meanwhile, the thickness of the sample did not increase more than once.