Masahiro Kobayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Masahiro Kobayashi has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Hideo Hayashi
Tokyo Metropolitan Industrial Technology Research Institute, Tokyo, Japan
3 shared publications - Hiromasa Namiki
Tokyo Metropolitan Industrial Technology Research Institute, Tokyo, Japan
3 shared publications - Hiroyuki Kagi
Graduate School of Science, The University of Tokyo 1 , 7–3–1 Hongo, Bunkyo-ku, Tokyo 113–0033
3 shared publications - Akira Monkawa
Tokyo Metropolitan Industrial Technology Research Institute, 2-4-10 Aomi, Koto-ku, Tokyo 135-0064, Japan
2 shared publications - Chris Ballentine
Department of Earth Sciences, University of Oxford, Oxford, UK
2 shared publications - Hirochika Sumino
Research Center for Advanced Science and Technology, The University of Tokyo
2 shared publications
Latest Publications
- 19 August 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (11) , 1757-1762
Quantitative analysis using LA-ICP-MS and powder samples dispersed in polyvinyl alcohol films
The combination of laser ablation and inductively coupled plasma mass spectrometry (LA-ICP-MS) is a powerful tool for direct analysis of solid samples. However, quantitative analyses by LA-ICP-MS require matrix-matched standard materials, which are not always available. In this study, we have developed a method that enables quantitative analyses of powder samples using LA-ICP-MS. The sample powder is dispersed in a polyvinyl alcohol (PVA) paste, which is a hydrophilic resin, and a film sample is obtained by a screen-printing technique. Analyte concentrations can be determined by a standard-addition method using an analyte-spiked film prepared by mixing standard solutions into the PVA paste. Because of its hydrophilicity, it is possible to increase the ratio of analytes (standard solutions) to the resin. Despite samples being diluted with the resin, this method has enough sensitivity to detect elements at concentrations < 0.1 μg/g. Several types of ceramic powder (SiC, ZrO2, and TiO2) were analyzed using this method, and all the analytes, the concentrations of which differed by five orders of magnitude (from < 1 μg/g to > 1 wt%), were accurately quantified. This method, in which reliable matrix-matched standard materials are easily tailored for each sample, can be potentially important in quantitative analyses using LA-ICP-MS. Graphical abstract
- 19 August 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (11) , 1757-1762
Quantitative analysis using LA-ICP-MS and powder samples dispersed in polyvinyl alcohol films
The combination of laser ablation and inductively coupled plasma mass spectrometry (LA-ICP-MS) is a powerful tool for direct analysis of solid samples. However, quantitative analyses by LA-ICP-MS require matrix-matched standard materials, which are not always available. In this study, we have developed a method that enables quantitative analyses of powder samples using LA-ICP-MS. The sample powder is dispersed in a polyvinyl alcohol (PVA) paste, which is a hydrophilic resin, and a film sample is obtained by a screen-printing technique. Analyte concentrations can be determined by a standard-addition method using an analyte-spiked film prepared by mixing standard solutions into the PVA paste. Because of its hydrophilicity, it is possible to increase the ratio of analytes (standard solutions) to the resin. Despite samples being diluted with the resin, this method has enough sensitivity to detect elements at concentrations < 0.1 μg/g. Several types of ceramic powder (SiC, ZrO2, and TiO2) were analyzed using this method, and all the analytes, the concentrations of which differed by five orders of magnitude (from < 1 μg/g to > 1 wt%), were accurately quantified. This method, in which reliable matrix-matched standard materials are easily tailored for each sample, can be potentially important in quantitative analyses using LA-ICP-MS. Graphical abstract
- 1 August 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (10) , 1757-1762
Quantitative analysis of powder samples using screen-printing techniques as sample preparation methods for LA-ICP-MS
The combination of laser ablation and inductively coupled plasma mass spectrometry (LA-ICP-MS) offers a powerful tool for directly analyzing solid samples. However, LA-ICP-MS has a limitation in quantitative analyses owing to a requirement for matrix-matched standard materials. In this study, we have developed a sample preparation method that facilitates quantitative analyses by LA-ICP-MS. The sample powder is dispersed in a liquid resin and film-like samples are prepared from the resulting paste by a screen-printing technique. The sample includes the analyte spiked with internal standards and is prepared by mixing standard solutions in the sample paste. Because all reagents except for the sample powder are liquids, homogeneous samples can be easily obtained. The internal standard and concentration of the spiked analyte can be tailored for each sample, which is a requirement for accurate quantitative analyses. The amount of sample and concentration of the spiked analyte are controlled against an internal standard, enabling internal standardization without the need to have an element of known concentration in the sample. The accuracy of this method was evaluated by analyzing impurity elements in TiO2 powder; however, it is expected that other materials could also be analyzed. The versatility and flexibility of this method suggest great potential for quantitative analyses by LA-ICP-MS, for which reliable matrix-matched standard materials are required. Graphical abstract
- 1 August 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (10) , 1757-1762
Quantitative analysis of powder samples using screen-printing techniques as sample preparation methods for LA-ICP-MS
The combination of laser ablation and inductively coupled plasma mass spectrometry (LA-ICP-MS) offers a powerful tool for directly analyzing solid samples. However, LA-ICP-MS has a limitation in quantitative analyses owing to a requirement for matrix-matched standard materials. In this study, we have developed a sample preparation method that facilitates quantitative analyses by LA-ICP-MS. The sample powder is dispersed in a liquid resin and film-like samples are prepared from the resulting paste by a screen-printing technique. The sample includes the analyte spiked with internal standards and is prepared by mixing standard solutions in the sample paste. Because all reagents except for the sample powder are liquids, homogeneous samples can be easily obtained. The internal standard and concentration of the spiked analyte can be tailored for each sample, which is a requirement for accurate quantitative analyses. The amount of sample and concentration of the spiked analyte are controlled against an internal standard, enabling internal standardization without the need to have an element of known concentration in the sample. The accuracy of this method was evaluated by analyzing impurity elements in TiO2 powder; however, it is expected that other materials could also be analyzed. The versatility and flexibility of this method suggest great potential for quantitative analyses by LA-ICP-MS, for which reliable matrix-matched standard materials are required. Graphical abstract
- 26 February 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 383, 133585
Localized surface plasmon resonance sensing of SO2 and H2S using zeolitic imidazolate framework-8
- 26 February 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 383, 133585
Localized surface plasmon resonance sensing of SO2 and H2S using zeolitic imidazolate framework-8
- 20 August 2021
- Published by Taylor & Francis in JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
- Vol. 54 (8) , 456-462
Direct Electrochemical Hydrogenation of Toluene Using a Microbial Electrolysis Cell Containing a Bicontinuous Microemulsion
The use of microbial electrolysis cells (MECs), which are an extension of microbial fuel cells, is a promising technique for producing H2 from renewable sources. In this study, we have developed an MEC containing a bicontinuous microemulsion in the cathode chamber, in which methylcyclohexane (MCH) is produced by the electrochemical hydrogenation of toluene. Owing to its relatively high H2 storage capacity and ease of handling, MCH has attracted considerable attention as an organic chemical hydride, which enables the efficient transportation and storage of H2. Despite the complicated chemical composition of the cathode solution, the faradaic efficiency of the toluene/MCH conversion in this study reached 49%. The balance between the toluene/MCH conversion and other competing reactions was found to be sensitive to the electrical potential and current density at the cathode. This new method for the direct production of organic chemical hydrides using microorganisms, which does not require the conventional stepwise process comprising H2 production and hydrogenation of aromatic compounds, is potentially important for establishing a renewable-energy-based society.
- 20 August 2021
- Published by Taylor & Francis in JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
- Vol. 54 (8) , 456-462
Direct Electrochemical Hydrogenation of Toluene Using a Microbial Electrolysis Cell Containing a Bicontinuous Microemulsion
The use of microbial electrolysis cells (MECs), which are an extension of microbial fuel cells, is a promising technique for producing H2 from renewable sources. In this study, we have developed an MEC containing a bicontinuous microemulsion in the cathode chamber, in which methylcyclohexane (MCH) is produced by the electrochemical hydrogenation of toluene. Owing to its relatively high H2 storage capacity and ease of handling, MCH has attracted considerable attention as an organic chemical hydride, which enables the efficient transportation and storage of H2. Despite the complicated chemical composition of the cathode solution, the faradaic efficiency of the toluene/MCH conversion in this study reached 49%. The balance between the toluene/MCH conversion and other competing reactions was found to be sensitive to the electrical potential and current density at the cathode. This new method for the direct production of organic chemical hydrides using microorganisms, which does not require the conventional stepwise process comprising H2 production and hydrogenation of aromatic compounds, is potentially important for establishing a renewable-energy-based society.
- Open Access
- 1 July 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (7) , 075125
Enhancement and manipulation of the thermoelectric properties of n-type argyrodite Ag8SnSe6 with ultralow thermal conductivity by controlling the carrier concentration through Ta doping
N-type argyrodite Ag8SnSe6 shows great potential as a novel thermoelectric material from room to middle temperatures. However, its thermoelectric properties cannot be manipulated because of the difficulty in controlling the carrier concentration by electron doping. In this study, to discover a suitable dopant for controlling the carrier concentration, we used Ta5+, Mo6+, and W6+ as dopants for Sn4+ in n-type Ag8SnSe6. Only Ta-doped Ag8SnSe6 was obtained as a single phase, and the thermoelectric properties relevant to the carrier concentration of n-type Ag8Sn1−xTaxSe6 (0.0 ≤ x ≤ 0.05) were experimentally investigated. The lattice thermal conductivities were ultralow (around 0.5 W m−1 K−1) and showed glass-like behavior independent of the temperature. The carrier concentration monotonically increased with increasing x. The power factor and dimensionless figure of merit ZT were related to the value of x, and they showed dome-like behavior as a function of x. The power factors of Ag8Sn1−xTaxSe6 in the orthorhombic phase at 300 K and superionic phase at 390 K reached ∼5.3 µW cm−1 K−2 for x = 0.0375 and ∼4.6 µW cm−1 K−2 for x = 0.05, respectively. The ZT values of ∼0.28 for x = 0.025 in the orthorhombic phase at 300 K and ∼0.51 for x = 0.0375 in the superionic phase at 390 K were ∼40% and ∼220% higher than those of non-doped Ag8SnSe6. Therefore, Ta doping of Ag8SnSe6 can control the carrier concentration and result in enhancement and manipulation of the thermoelectric properties.
- 1 July 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (7) , 075125
Open AccessEnhancement and manipulation of the thermoelectric properties of n-type argyrodite Ag8SnSe6 with ultralow thermal conductivity by controlling the carrier concentration through Ta doping
N-type argyrodite Ag8SnSe6 shows great potential as a novel thermoelectric material from room to middle temperatures. However, its thermoelectric properties cannot be manipulated because of the difficulty in controlling the carrier concentration by electron doping. In this study, to discover a suitable dopant for controlling the carrier concentration, we used Ta5+, Mo6+, and W6+ as dopants for Sn4+ in n-type Ag8SnSe6. Only Ta-doped Ag8SnSe6 was obtained as a single phase, and the thermoelectric properties relevant to the carrier concentration of n-type Ag8Sn1−xTaxSe6 (0.0 ≤ x ≤ 0.05) were experimentally investigated. The lattice thermal conductivities were ultralow (around 0.5 W m−1 K−1) and showed glass-like behavior independent of the temperature. The carrier concentration monotonically increased with increasing x. The power factor and dimensionless figure of merit ZT were related to the value of x, and they showed dome-like behavior as a function of x. The power factors of Ag8Sn1−xTaxSe6 in the orthorhombic phase at 300 K and superionic phase at 390 K reached ∼5.3 µW cm−1 K−2 for x = 0.0375 and ∼4.6 µW cm−1 K−2 for x = 0.05, respectively. The ZT values of ∼0.28 for x = 0.025 in the orthorhombic phase at 300 K and ∼0.51 for x = 0.0375 in the superionic phase at 390 K were ∼40% and ∼220% higher than those of non-doped Ag8SnSe6. Therefore, Ta doping of Ag8SnSe6 can control the carrier concentration and result in enhancement and manipulation of the thermoelectric properties.
- 13 December 2019
- Published by Springer Nature in Plasmonics
- Vol. 15 (3) , 805-811
Detection of SO2 at the ppm Level with Localized Surface Plasmon Resonance (LSPR) Sensing
- 13 December 2019
- Published by Springer Nature in Plasmonics
- Vol. 15 (3) , 805-811
Detection of SO2 at the ppm Level with Localized Surface Plasmon Resonance (LSPR) Sensing
- Open Access
- 14 February 2019
- Published by American Geophysical Union (AGU) in Geochemistry, Geophysics, Geosystems
- Vol. 20 (2) , 952-973
Halogen Heterogeneity in the Lithosphere and Evolution of Mantle Halogen Abundances Inferred From Intraplate Mantle Xenoliths
We present halogen, noble gas, and major and trace element compositions of mantle xenoliths from intraplate settings (Eifel, Kilbourne Hole, San Carlos, and Hawaii). The xenoliths show a wide range of halogen elemental ratios, which form two arrays centered on the halogen composition of mid‐ocean ridge basalts. The samples on the array toward high I/Cl value have relatively low Cl concentration and low ratios of highly incompatible elements relative to heavy rare earth elements, whereas the samples on the array toward low Br/Cl value have higher Cl concentration and trace elements ratios. The detailed mechanisms to account for these signatures are equivocal at present. However, they are most likely to be related to secondary processes of volatile loss during partial melting and secondary phase formation during interaction with melts. The common primary mid‐ocean ridge basalt‐like halogen ratios in mantle xenoliths from different parts of the globe indicate that the mantle itself must have a relatively uniform composition over a wide scale. The mantle has maintained its halogen composition over billion year timescales without being affected by I‐rich halogens being transported into the mantle. Mass balance calculations suggest that, in order to maintain the I/Cl ratio of the convecting mantle over 2 Gyr, the I/Cl ratio of the subducted halogens must be no more than several times higher than the present‐day mantle value.
- 14 February 2019
- Published by American Geophysical Union (AGU) in Geochemistry, Geophysics, Geosystems
- Vol. 20 (2) , 952-973
Open AccessHalogen Heterogeneity in the Lithosphere and Evolution of Mantle Halogen Abundances Inferred From Intraplate Mantle Xenoliths
We present halogen, noble gas, and major and trace element compositions of mantle xenoliths from intraplate settings (Eifel, Kilbourne Hole, San Carlos, and Hawaii). The xenoliths show a wide range of halogen elemental ratios, which form two arrays centered on the halogen composition of mid‐ocean ridge basalts. The samples on the array toward high I/Cl value have relatively low Cl concentration and low ratios of highly incompatible elements relative to heavy rare earth elements, whereas the samples on the array toward low Br/Cl value have higher Cl concentration and trace elements ratios. The detailed mechanisms to account for these signatures are equivocal at present. However, they are most likely to be related to secondary processes of volatile loss during partial melting and secondary phase formation during interaction with melts. The common primary mid‐ocean ridge basalt‐like halogen ratios in mantle xenoliths from different parts of the globe indicate that the mantle itself must have a relatively uniform composition over a wide scale. The mantle has maintained its halogen composition over billion year timescales without being affected by I‐rich halogens being transported into the mantle. Mass balance calculations suggest that, in order to maintain the I/Cl ratio of the convecting mantle over 2 Gyr, the I/Cl ratio of the subducted halogens must be no more than several times higher than the present‐day mantle value.
- Open Access
- 1 January 2017
- Published by Elsevier in Earth and Planetary Science Letters
- Vol. 457, 106-116
Slab-derived halogens and noble gases illuminate closed system processes controlling volatile element transport into the mantle wedge
- 1 January 2017
- Published by Elsevier in Earth and Planetary Science Letters
- Vol. 457, 106-116
Open AccessSlab-derived halogens and noble gases illuminate closed system processes controlling volatile element transport into the mantle wedge
- 1 February 1998
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 37 (2A) , L190-192
The Role of Intermolecular Electrostatic Interaction on Appearance of the Periodic Band Structure in Type I Collagen Fibril
Intermolecular electrostatic interaction between staggered tropocollagens is calculated, focussing on the condition such that D=(G+L)/K in the collagen fibril with a periodic band structure, where D, G and L are lengths of band period, gap region and tropocollagen molecule respectively, and K=[L/D]+1 where [L/D] is the highest integer below L/D. By changing D, G and K, only two cases are found where the interaction energy is minimum at every position with multiples of D; i.e., D=234, G=124, K=5 and D=235, G=129, K=5. Such results propose the origin of a periodic band structure or the Hodge-Petruska scheme and a pseudohexagonal crystal in type I collagen fibrils.
- 1 February 1998
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 37 (2A) , L190-192
The Role of Intermolecular Electrostatic Interaction on Appearance of the Periodic Band Structure in Type I Collagen Fibril
Intermolecular electrostatic interaction between staggered tropocollagens is calculated, focussing on the condition such that D=(G+L)/K in the collagen fibril with a periodic band structure, where D, G and L are lengths of band period, gap region and tropocollagen molecule respectively, and K=[L/D]+1 where [L/D] is the highest integer below L/D. By changing D, G and K, only two cases are found where the interaction energy is minimum at every position with multiples of D; i.e., D=234, G=124, K=5 and D=235, G=129, K=5. Such results propose the origin of a periodic band structure or the Hodge-Petruska scheme and a pseudohexagonal crystal in type I collagen fibrils.