Ahmet Keles
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahmet Keles has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Mehmet Ozgur Uyanik
Department of Endodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey
3 shared publications - Emel Uzunoğlu Özyürek
Department of Endodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkiye
2 shared publications - Emre Nagas
Department of Endodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey
2 shared publications - Selen Küçükkaya Eren
Hacettepe University, Turkey
2 shared publications - Sevinc Askerbeyli Örs
Hacettepe Üniversitesi, Diş Hekimliği Fakültesi, Endodonti Bölümü, Ankara, Türkiye
2 shared publications A. Eymirli
Department of Endodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey
1 shared publication
Latest Publications
- 16 September 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (10) , 1-9
Evaluating the efficacy of non-activated microbubble emulsions in biofilm removal from 3D-printed root canals
Objectives This study evaluates the effectiveness of non-activated microbubble emulsions in removing biofilms in simulated minimally shaped root canals. Materials and methods Enterococcus faecalis biofilms were developed over three weeks in various sizes of 3D-printed root canal models. The biofilm removal efficiency of microbubble emulsions (MB) was compared with several irrigants, sodium hypochlorite (NaOCl), distilled water (DW), and hydrogen peroxide (HP), across different root canal dimensions (20.04, 20.06, 40.04, 40.06). Irrigation was performed using 2.5 mL of each solution for one minute. In the MB groups, the canal was filled with a single emulsion drop and left for one minute. We used confocal laser scanning microscopy and crystal violet colorimetric analysis to assess the effectiveness of biofilm eradication. Bonferroni tests and two-way ANOVA were employed to analyze the data. Results In narrow canals, MB emulsions demonstrated biofilm removal efficacy comparable to NaOCl (P > .05). However, NaOCl was the most effective irrigation solution for wider canals (P < .05). Canal size significantly influenced the biofilm removal efficacy in the MB group (P < .05). Overall, both MB emulsions and NaOCl achieved better biofilm removal results than DW and HP (P < .05). Conclusion The non-activated MBs have shown effective antibiofilm properties in narrow canals, making them suitable for a minimally invasive approach and indicating their potential role in developing improved irrigation protocols. Clinical relevance This study highlights the potential of microbubble emulsions as effective irrigants for minimally shaped root canals, supporting minimally invasive endodontic strategies.
- 16 September 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (10) , 1-9
Evaluating the efficacy of non-activated microbubble emulsions in biofilm removal from 3D-printed root canals
Objectives This study evaluates the effectiveness of non-activated microbubble emulsions in removing biofilms in simulated minimally shaped root canals. Materials and methods Enterococcus faecalis biofilms were developed over three weeks in various sizes of 3D-printed root canal models. The biofilm removal efficiency of microbubble emulsions (MB) was compared with several irrigants, sodium hypochlorite (NaOCl), distilled water (DW), and hydrogen peroxide (HP), across different root canal dimensions (20.04, 20.06, 40.04, 40.06). Irrigation was performed using 2.5 mL of each solution for one minute. In the MB groups, the canal was filled with a single emulsion drop and left for one minute. We used confocal laser scanning microscopy and crystal violet colorimetric analysis to assess the effectiveness of biofilm eradication. Bonferroni tests and two-way ANOVA were employed to analyze the data. Results In narrow canals, MB emulsions demonstrated biofilm removal efficacy comparable to NaOCl (P > .05). However, NaOCl was the most effective irrigation solution for wider canals (P < .05). Canal size significantly influenced the biofilm removal efficacy in the MB group (P < .05). Overall, both MB emulsions and NaOCl achieved better biofilm removal results than DW and HP (P < .05). Conclusion The non-activated MBs have shown effective antibiofilm properties in narrow canals, making them suitable for a minimally invasive approach and indicating their potential role in developing improved irrigation protocols. Clinical relevance This study highlights the potential of microbubble emulsions as effective irrigants for minimally shaped root canals, supporting minimally invasive endodontic strategies.
- 2 September 2023
- Published by Taylor & Francis in Drug and Chemical Toxicology
- Vol. 47 (5) , 693-709
Assessment of redox homeostasis via genotoxicity, cytotoxicity, apoptosis and NRF-2 in colorectal cancer cell lines after treatment with Ganoderma lucidum extract
This study aimed to investigate the cytotoxic and apoptotic effects of Ganoderma lucidum, Pleurotus ostreatus, Pleurotus eryngii, and Inonotus hispidus fungal extracts on HT-29 and HCT-116 colorectal cancer cell lines and to search the DNA damage and oxidative stress caused by these extracts. Accordingly, mushroom extracts were applied to colorectal cancer cell lines in vitro, and the IC50 result was obtained with the MTT test. According to the IC50 result, Ganoderma lucidum extract had the most effective cytotoxicity value among all used mushroom extracts. TAS, TOS, and NRF-2 tests were used to investigate the molecular effect of Ganoderma lucidum extract on oxidative stress; the DNA ladder test was performed to assess DNA damage, the Scratch assay method was applied for cell migration analysis, and the colony assay was used to determine the colony formation potential of the cells. The results showed that Ganoderma lucidum mushroom extract reduces cell proliferation, colony formation, and NRF-2, induces DNA damage, slows cell migration, and increases oxidative stress. This study shows that Ganoderma lucidum mushroom extract reduces cell proliferation through damaging cellular DNA and has a cytotoxic effect in colorectal cancer cell lines.
- 2 September 2023
- Published by Taylor & Francis in Drug and Chemical Toxicology
- Vol. 47 (5) , 693-709
Assessment of redox homeostasis via genotoxicity, cytotoxicity, apoptosis and NRF-2 in colorectal cancer cell lines after treatment with Ganoderma lucidum extract
This study aimed to investigate the cytotoxic and apoptotic effects of Ganoderma lucidum, Pleurotus ostreatus, Pleurotus eryngii, and Inonotus hispidus fungal extracts on HT-29 and HCT-116 colorectal cancer cell lines and to search the DNA damage and oxidative stress caused by these extracts. Accordingly, mushroom extracts were applied to colorectal cancer cell lines in vitro, and the IC50 result was obtained with the MTT test. According to the IC50 result, Ganoderma lucidum extract had the most effective cytotoxicity value among all used mushroom extracts. TAS, TOS, and NRF-2 tests were used to investigate the molecular effect of Ganoderma lucidum extract on oxidative stress; the DNA ladder test was performed to assess DNA damage, the Scratch assay method was applied for cell migration analysis, and the colony assay was used to determine the colony formation potential of the cells. The results showed that Ganoderma lucidum mushroom extract reduces cell proliferation, colony formation, and NRF-2, induces DNA damage, slows cell migration, and increases oxidative stress. This study shows that Ganoderma lucidum mushroom extract reduces cell proliferation through damaging cellular DNA and has a cytotoxic effect in colorectal cancer cell lines.
- 1 February 2023
- Published by Wiley in Australian Endodontic Journal
- Vol. 49 (3) , 470-475
Effect of different sealer activation techniques on dentinal tubule penetration
The aim of this study was to evaluate the influence of different activation techniques on dentin tubule penetration of root canal sealer. Seventy‐five teeth with single canals were chemomechanically prepared. A calcium silicate‐based sealer was stained with a fluorescent dye (rhodamine B), placed into the canals and activated according to the following groups: control (no activation), EDDY, EndoActivator, ultrasonic and XP‐Endo Finisher. Then, the samples were obturated. The percentages of sealer penetration at various depth levels of root sections were measured with confocal laser scanning microscopy. XP‐Endo Finisher presented the highest penetration at 50 μm (p < 0.05). XP‐Endo Finisher showed similar penetration with EDDY at 100 and 200 μm (p > 0.05) while presented higher penetration than the other groups (p < 0.05). At 500 μm, XP‐Endo Finisher presented higher penetration than EndoActivator (p < 0.05) while similar penetration with the other groups (p > 0.05). XP‐Endo Finisher can be recommended for activation during sealer placement for better penetration into dentin tubules.
- 1 February 2023
- Published by Wiley in Australian Endodontic Journal
- Vol. 49 (3) , 470-475
Effect of different sealer activation techniques on dentinal tubule penetration
The aim of this study was to evaluate the influence of different activation techniques on dentin tubule penetration of root canal sealer. Seventy‐five teeth with single canals were chemomechanically prepared. A calcium silicate‐based sealer was stained with a fluorescent dye (rhodamine B), placed into the canals and activated according to the following groups: control (no activation), EDDY, EndoActivator, ultrasonic and XP‐Endo Finisher. Then, the samples were obturated. The percentages of sealer penetration at various depth levels of root sections were measured with confocal laser scanning microscopy. XP‐Endo Finisher presented the highest penetration at 50 μm (p < 0.05). XP‐Endo Finisher showed similar penetration with EDDY at 100 and 200 μm (p > 0.05) while presented higher penetration than the other groups (p < 0.05). At 500 μm, XP‐Endo Finisher presented higher penetration than EndoActivator (p < 0.05) while similar penetration with the other groups (p > 0.05). XP‐Endo Finisher can be recommended for activation during sealer placement for better penetration into dentin tubules.
- 31 August 2021
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 8 (2) , 327-331
Effect of chloroform on the cyclic fatigue resistance of nickel-titanium retreatment instruments
Background: The purpose of this study was to evaluate the cyclic fatigue resistance of 4 different rotary nickel-titanium (NiTi) retreatment instruments after immersion in chloroform solution. Methods: A total of 120 ProTaper D3, R-Endo R3, D-Race DR2 and Mtwo R2 retreatment instruments were used. Thirty instruments of each system were randomly divided into 2 groups (n=15); Group 1: no immersion and Group 2: immersion in chloroform for 5 min. The instruments were operated in a dynamic cyclic fatigue test device until fracture occurred. The number of cycles to fracture and length of the fractured fragment for each instrument were recorded. Representative samples were examined under a scanning electron microscope. Data were analyzed by using 2-way analysis of variance and Bonferroni tests. Results: The ProTaper D3 and R-Endo R3 instruments showed the highest cyclic fatigue resistance whether or not immersed in chloroform (p0.05). The Mtwo R2 instruments were more resistant to cyclic fatigue than the D-Race DR2 instruments before and after immersed in chloroform (p<0.05).Conclusion: The immersion in chloroform had no effect on the cyclic fatigue resistance of retreatment instruments. The ProTaper D3 and R-Endo R3 instruments were more resistant to cyclic fatigue than other retreatment instruments regardless of chloroform exposure. Keywords: chloroform, cyclic fatigue, endodontics, nickel-titanium, retreatment
- 31 August 2021
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 8 (2) , 327-331
Effect of chloroform on the cyclic fatigue resistance of nickel-titanium retreatment instruments
Background: The purpose of this study was to evaluate the cyclic fatigue resistance of 4 different rotary nickel-titanium (NiTi) retreatment instruments after immersion in chloroform solution. Methods: A total of 120 ProTaper D3, R-Endo R3, D-Race DR2 and Mtwo R2 retreatment instruments were used. Thirty instruments of each system were randomly divided into 2 groups (n=15); Group 1: no immersion and Group 2: immersion in chloroform for 5 min. The instruments were operated in a dynamic cyclic fatigue test device until fracture occurred. The number of cycles to fracture and length of the fractured fragment for each instrument were recorded. Representative samples were examined under a scanning electron microscope. Data were analyzed by using 2-way analysis of variance and Bonferroni tests. Results: The ProTaper D3 and R-Endo R3 instruments showed the highest cyclic fatigue resistance whether or not immersed in chloroform (p0.05). The Mtwo R2 instruments were more resistant to cyclic fatigue than the D-Race DR2 instruments before and after immersed in chloroform (p<0.05).Conclusion: The immersion in chloroform had no effect on the cyclic fatigue resistance of retreatment instruments. The ProTaper D3 and R-Endo R3 instruments were more resistant to cyclic fatigue than other retreatment instruments regardless of chloroform exposure. Keywords: chloroform, cyclic fatigue, endodontics, nickel-titanium, retreatment
- 1 January 2020
- Published by Medknow in Nigerian Journal of Clinical Practice
- Vol. 23 (3) , 381-385
Effect of various solutions on the removal of orange-brown precipitate formed by interaction of sodium hypochlorite and chlorhexidine with or without ultrasonic activationZ
Canals were flushed with 17% EDTA, 10% citric acid, 1% phytic acid, 96% alcohol and distilled water either using syringe irrigation or ultrasonic activation, after creating orange-brown precipitate. Teeth were sectioned longitudinally and subjected to stereomicroscopic analysis. The amount of precipitate was scored and the data were analyzed (P = 0.05). Results: There were no differences detected among the tested solutions (P > 0.05). There was a significant difference between ultrasonically activated irrigation and syringe irrigation for EDTA and distilled water in coronal, middle portions (P < 0.05). Conclusions: Ultrasonic activation significantly improved the precipitate removal capacity of EDTA and DW. Tested solutions were similarly effective regarding the removal of the precipitate....
- 1 January 2020
- Published by Medknow in Nigerian Journal of Clinical Practice
- Vol. 23 (3) , 381-385
Effect of various solutions on the removal of orange-brown precipitate formed by interaction of sodium hypochlorite and chlorhexidine with or without ultrasonic activationZ
Canals were flushed with 17% EDTA, 10% citric acid, 1% phytic acid, 96% alcohol and distilled water either using syringe irrigation or ultrasonic activation, after creating orange-brown precipitate. Teeth were sectioned longitudinally and subjected to stereomicroscopic analysis. The amount of precipitate was scored and the data were analyzed (P = 0.05). Results: There were no differences detected among the tested solutions (P > 0.05). There was a significant difference between ultrasonically activated irrigation and syringe irrigation for EDTA and distilled water in coronal, middle portions (P < 0.05). Conclusions: Ultrasonic activation significantly improved the precipitate removal capacity of EDTA and DW. Tested solutions were similarly effective regarding the removal of the precipitate....
- Open Access
- 31 May 2019
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 22 (2) , 192-197
Comparison of Apically Extruded Debris Associated with Different Nickel–Titanium Systems
Objective: The aim of this study is to evaluate the influence of different instrument systems on the amount of extruded debris. Materials and methods: A total of 30 extracted mandibular molars with two separate canals and apical foramina in the mesial roots were selected. The root canals (n=10) were randomly assigned to the six groups of file systems as follows: ProTaper Next (PTN), WaveOne (WO), WaveOne Gold (WOG), One Shape (OS), Reciproc (R) and Reciproc Blue (RB). The extruded debris during the instrumentation was collected into Eppendorf tubes, which were weighed and then stored in an incubator at 70°C over a period of five days to evaporate the irrigant. After the incubation process, the Eppendorf tubes were weighed again. The difference between these two measurements, the first one before and the second one after the incubation process, was calculated. Data were statistically analyzed, and the significance level was set at p<0.05. Results: R produced less debris compared to WO. R and PTN files produced significantly less debris compared to the OS files (p < 0.05). Extruded debris in RB and WO groups were not significantly different, while RB produced less debris than WOG and OS (p<0.05). Conclusions: All instrumentation systems allowed for the apical extrusion of the debris. Keywords: Apically extruded debris, Endodontics, Ni-Ti systems ÖZ Amaç: Bu çalışmanın amacı, farklı nikel titanyum eğe sistemlerini apikalden taşan debris miktarı açısından değerlendirmektir. Gereç ve Yöntemler: Bu çalışmada mesial köklerinde iki ayrı kanal ve apikal foramene sahip toplam 30 adet mandibular molar diş seçildi. Kök kanalları (n = 10) aşağıdaki altı eğe sistemine göre rastgele ayrılmıştır: ProTaper Next (PTN), WaveOne (WO), WaveOne Gold (WOG), One Shape (OS), Reciproc (R) ve Reciproc Blue (RB). İnstrümantasyon sırasında ekstrüde edilmiş debrisler önceden boş ağırlıkları ölçülmüş eppendorf tüplerinde toplandı ve sonra irrigantı buharlaştırmak için beş günlük bir süre boyunca 70 ° C'de bir inkübatörde saklandı. İnkübasyon sürecinden sonra, eppendorf tüpleri tekrar tartıldı. Bu iki ölçüm arasındaki fark hesaplandı. Veriler istatistiksel olarak analiz edildi ve anlamlılık düzeyi p <0,05 olarak belirlendi. Bulgular: R, WO ile karşılaştırıldığında daha az debris taşmasına sebep oldu. R ve PTN eğeleri, OS eğelere göre anlamlı derecede daha az debris taşımına sebep oldu (p <0,05). RB ve WO gruplarında apikalden taşan debris miktarı anlamlı ölçüde farklı değildi ancak RB WOG ve OS'den daha az debris taşmasına sebep oldu (p <0.05). Sonuç: Bütün eğe sistemleri apikalden debris taşırmıştır. Anahtar Kelimeler: Apikal taşma, Endodonti, Ni-Ti sistemleri
- 31 May 2019
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 22 (2) , 192-197
Open AccessComparison of Apically Extruded Debris Associated with Different Nickel–Titanium Systems
Objective: The aim of this study is to evaluate the influence of different instrument systems on the amount of extruded debris. Materials and methods: A total of 30 extracted mandibular molars with two separate canals and apical foramina in the mesial roots were selected. The root canals (n=10) were randomly assigned to the six groups of file systems as follows: ProTaper Next (PTN), WaveOne (WO), WaveOne Gold (WOG), One Shape (OS), Reciproc (R) and Reciproc Blue (RB). The extruded debris during the instrumentation was collected into Eppendorf tubes, which were weighed and then stored in an incubator at 70°C over a period of five days to evaporate the irrigant. After the incubation process, the Eppendorf tubes were weighed again. The difference between these two measurements, the first one before and the second one after the incubation process, was calculated. Data were statistically analyzed, and the significance level was set at p<0.05. Results: R produced less debris compared to WO. R and PTN files produced significantly less debris compared to the OS files (p < 0.05). Extruded debris in RB and WO groups were not significantly different, while RB produced less debris than WOG and OS (p<0.05). Conclusions: All instrumentation systems allowed for the apical extrusion of the debris. Keywords: Apically extruded debris, Endodontics, Ni-Ti systems ÖZ Amaç: Bu çalışmanın amacı, farklı nikel titanyum eğe sistemlerini apikalden taşan debris miktarı açısından değerlendirmektir. Gereç ve Yöntemler: Bu çalışmada mesial köklerinde iki ayrı kanal ve apikal foramene sahip toplam 30 adet mandibular molar diş seçildi. Kök kanalları (n = 10) aşağıdaki altı eğe sistemine göre rastgele ayrılmıştır: ProTaper Next (PTN), WaveOne (WO), WaveOne Gold (WOG), One Shape (OS), Reciproc (R) ve Reciproc Blue (RB). İnstrümantasyon sırasında ekstrüde edilmiş debrisler önceden boş ağırlıkları ölçülmüş eppendorf tüplerinde toplandı ve sonra irrigantı buharlaştırmak için beş günlük bir süre boyunca 70 ° C'de bir inkübatörde saklandı. İnkübasyon sürecinden sonra, eppendorf tüpleri tekrar tartıldı. Bu iki ölçüm arasındaki fark hesaplandı. Veriler istatistiksel olarak analiz edildi ve anlamlılık düzeyi p <0,05 olarak belirlendi. Bulgular: R, WO ile karşılaştırıldığında daha az debris taşmasına sebep oldu. R ve PTN eğeleri, OS eğelere göre anlamlı derecede daha az debris taşımına sebep oldu (p <0,05). RB ve WO gruplarında apikalden taşan debris miktarı anlamlı ölçüde farklı değildi ancak RB WOG ve OS'den daha az debris taşmasına sebep oldu (p <0.05). Sonuç: Bütün eğe sistemleri apikalden debris taşırmıştır. Anahtar Kelimeler: Apikal taşma, Endodonti, Ni-Ti sistemleri
- 1 February 2019
- Published by Elsevier in Journal of Endodontics
- Vol. 45 (2) , 205-208
Effect of Temperature of Sodium Hypochlorite on Cyclic Fatigue Resistance of Heat-treated Reciprocating Files
- 1 February 2019
- Published by Elsevier in Journal of Endodontics
- Vol. 45 (2) , 205-208
Effect of Temperature of Sodium Hypochlorite on Cyclic Fatigue Resistance of Heat-treated Reciprocating Files
- 17 January 2019
- Published by Wiley in International Endodontic Journal
- Vol. 52 (6) , 880-886
Influence of static and dynamic cyclic fatigue tests on the lifespan of four reciprocating systems at different temperatures
Aim: To compare the cyclic fatigue resistance of four reciprocating single‐file systems within artificial stainless‐steel canals at two temperatures using different kinematics.Methodology: A total of 240 instruments, Reciproc Blue, Reciproc, WaveOne Gold and WaveOne, (60 of each), were tested at room and intracanal temperature using both a static and a dynamic model (n = 15) in a stainless‐steel artificial canal with an inner diameter of 1.5 mm, 60° angle of curvature and 5 mm radius of curvature until fracture occurred. The time to fracture was measured in seconds using a digital chronometer, and data were analysed using one‐way analysis of variance and Bonferroni tests.Results: WaveOne instruments had significantly less fatigue resistance compared to that of other systems in all conditions (P < 0.05). Comparison of the results from the static and dynamic models at both temperatures revealed that fatigue resistance was significantly increased in the dynamic model for all the instrument systems (P < 0.05). Temperature did not influence the cyclic fatigue resistance results (P > 0.05). There were no significant differences in the mean length of the fractured fragments of the various instruments tested (P > 0.05).Conclusion: WaveOne files had a shorter cyclic fatigue life. The dynamic axial movement extended the cyclic fatigue life, but it did not have any influence on the comparison among the instruments tested in respect of the static test. Temperature did not significantly affect the cyclic fatigue of these nickel–titanium files.
- 17 January 2019
- Published by Wiley in International Endodontic Journal
- Vol. 52 (6) , 880-886
Influence of static and dynamic cyclic fatigue tests on the lifespan of four reciprocating systems at different temperatures
Aim: To compare the cyclic fatigue resistance of four reciprocating single‐file systems within artificial stainless‐steel canals at two temperatures using different kinematics.Methodology: A total of 240 instruments, Reciproc Blue, Reciproc, WaveOne Gold and WaveOne, (60 of each), were tested at room and intracanal temperature using both a static and a dynamic model (n = 15) in a stainless‐steel artificial canal with an inner diameter of 1.5 mm, 60° angle of curvature and 5 mm radius of curvature until fracture occurred. The time to fracture was measured in seconds using a digital chronometer, and data were analysed using one‐way analysis of variance and Bonferroni tests.Results: WaveOne instruments had significantly less fatigue resistance compared to that of other systems in all conditions (P < 0.05). Comparison of the results from the static and dynamic models at both temperatures revealed that fatigue resistance was significantly increased in the dynamic model for all the instrument systems (P < 0.05). Temperature did not influence the cyclic fatigue resistance results (P > 0.05). There were no significant differences in the mean length of the fractured fragments of the various instruments tested (P > 0.05).Conclusion: WaveOne files had a shorter cyclic fatigue life. The dynamic axial movement extended the cyclic fatigue life, but it did not have any influence on the comparison among the instruments tested in respect of the static test. Temperature did not significantly affect the cyclic fatigue of these nickel–titanium files.