Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


He-Gao Wu has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Probabilistic Aseismic Performance Assessment of Rubber–Sand–Concrete Tunnel Linings Considering Spatial Variability of Rock Mass

    by Kaichen Li, Xiancheng Mei, Baiyi Li, Hao Sheng, Zhen Cui, Yiheng Wang, Hegao Wu, Tao Wang

    In tunnel engineering, the integration of aseismic materials and structural designs has become a prevalent strategy to reduce earthquake-induced damage. However, previous studies on the seismic performance of tunnel structures predominantly employed deterministic methods, overlooking the spatial variability of the surrounding rock mass. This oversight often leads to an overestimation of structural performance, posing potential risks to the project. This study develops a probabilistic framework based on random field theory to evaluate the aseismic performance of tunnel linings incorporating a rubber–sand–concrete (RSC) constrained damping layer. The analysis systematically evaluates the aseismic performance of RSC across varying peak ground acceleration (PGA) levels and tunnel depth conditions. The findings are compared with results from traditional deterministic approaches. The probabilistic analysis indicates the following: (1) a reduction of approximately 70% in the dispersion of maximum principal stresses across various PGAs; (2) a decrease in RSC’s aseismic performance with greater burial depths, though it remains substantial overall, and (3) a reduction in the failure probability from 31.8% to 16.3% at PGA = 1.2 g. Furthermore, deterministic methods tend to produce overly optimistic estimates of tunnel aseismic performance, highlighting the need for probabilistic analysis.

  • Open Access

    Bearing Characteristics with Effect of Bond–Slip Behavior in Massive Ring-Type Reinforced Concrete Structures

    by Wen-Tao Xu, Zhu Ma, He-Gao Wu, Chang-Zheng Shi

    The bond–slip behavior of the steel–concrete interface is critical in reinforced concrete (RC) structures since the bond action is the mechanism that ensures the two materials work in co-operation. However, there is little research considering the bond–slip behavior in massive ring-type reinforced concrete (MRRC) structure bearing analyses due to the complexity of modeling the interfacial behavior. Hence, the influence of the bond–slip behavior on the bearing characteristics of MRRC structures remains unclear. Steel-lined reinforced concrete penstock is such an MRRC structure, composed of steel liner and reinforced concrete and commonly used in diversion pipelines. This paper aims to explore the bearing characteristics considering the bond–slip behavior in the composite penstock by using a promising numerical method, the cohesive zone model. Three interface models were proposed to represent the different interaction conditions at the steel–concrete interface. Moreover, a sensitivity analysis was performed to study the impact of the bond strength on the bond performance and structural behavior. The simulation results showed that the prediction results (steel stress and crack process) considering the bond–slip behavior were in good agreement with the experimental results. The steel stresses near the cracks were smaller and more uniform after considering the bond–slip behavior, since the stresses were no longer concentrated on the crack but distributed in an area near the crack. However, the steel stress differences in these models were within 10%, which means that the bond performance had a limited effect on the structural safety design. The crack widths were greatly influenced by the bond conditions, and the maximum crack width (0.461 mm) in poor conditions was beyond the limiting value (0.3 mm). Consequently, bond–slip behavior must be paid more attention in durability design.


  • Open Access

    Embedment of Steel Spiral Cases in Concrete: Lessons from a Structural Deformation Accident in China

    by Xiaofeng Gao, Dan Fu, Hegao Wu

    A spiral case structure (SCS) plays a significant role in the safe and reliable operation of a hydroelectric power plant (HPP). In an HPP with 700 MW class turbine in China, a structural deformation accident happened in the construction period causing severe loss. Based on in-situ measured data, this study focuses on two major differences of this SCS that might cause the accident: (a) the construction condition, and (b) the shape of steel spiral case (SSC). The accident is reproduced in numerical study, and the simulation results agree reasonably well with in-situ measured data. The results show that the construction condition is a main factor causing the accident, but it is not the only cause of the raising deformation. The findings reveal that the post-accident stresses of steel structures are still at a relatively low level, and it would not be a major concern. The study also shows that the SSC with non-circle sections tends to have larger deformation under internal water pressure, and the deformation of the stay ring needs more attention in the construction period. The major limitation of this study is that this study merely focuses on the construction period. If such SCSs were to be used in a wider range, a follow-up study focusing on the operation period should be considered.


  • Open Access

    Structural Behavior of Massive Reinforced Concrete Structures Exposed to Thermomechanical Loads

    by Zhu Ma, Changzheng Shi, Hegao Wu, Songzi Liu

    Massive reinforced concrete (MRC) structures are utilized in a variety of applications where both mechanical and thermal properties are of concern. A 1:2 large-scale test model of the steel-lined reinforced concrete penstock (a kind of MRC) and a coupled thermomechanical numerical analysis are both implemented to investigate the thermomechanical effects on structural behavior. Three different temperature fields and eight temperature gradients are selected to explore how the temperature affects the crack width, steel stress, and deformation. The results show that the numerical simulation results are consistent with the experimental results and that this method can be applied to other similar MRC structure analysis. The thermal effect can cause 10−3~10−2 mm thermal crack width and ±45 MPa thermal stress and this may lead the total crack width to exceed the limited value and the reinforcement stress beyond the yield strength. Consequently, the influence of the thermomechanical loads cannot be ignored and the corresponding temperature control measures must be taken to ensure structural safety and durability.


  • Open Access

    Effect of Temporary Internal Water Pressure on Structural Performance of Spiral Case Structure in Pumped-Storage Power Plants

    by Xiaofeng Gao, Hegao Wu, Dan Fu

    Temporary internal water pressure (IWP) during a construction period fundamentally affects the structural performance of spiral case structures (SCSs) in pumped-storage power plants (PSPPs). However, its actual role is rarely studied. This study focuses on this issue considering the complex construction-to-operation process of SCSs. An ABAQUS-based complete simulation procedure (CSP) is used with contact non-linearity considered. The contact-closing ratio is introduced to quantitively describe the contact status, and different design philosophies for temporary IWP are compared. The results show that the temporary IWP should be no greater than 80% of the minimum static headwater to ensure an overall contact-closing status under normal operating conditions in this study. The findings reveal that the cracking risk of concrete is negatively correlated with temporary IWP, while high temporary IWP is not suggested. Moreover, the stay ring actually shares a certain part of the unbalanced hydraulic thrust, which cannot be ignored. The limitation of this study might mainly lie in the idealized linear-elastic description of concrete. The temporary IWP should be designed with overall consideration of the IWP under normal operating conditions, the IWP-jointly-resisting status and design demands.


  • Open Access

    Pipe-Soil Interaction and Sensitivity Study of Large-Diameter Buried Steel Pipes

    by He-Gao Wu, Jin-Hong Yu, Chang-Zheng Shi, Zhu Ma


  • Open Access

    Installation Time of an Initial Support for Tunnel Excavation upon the Safety Factors of Surrounding Rock

    by Yan-Jun Zhang, Kai Su, Hong-Ze Zhu, Zhong-Dong Qian, He-Gao Wu

    In engineering practice, the initial support system is commonly installed in the vicinity of the tunnel face after excavation, whereas the self-capacity of rock mass will fail to be utilized and the cost of the initial support system will be expensive. In this study, a methodology is proposed to determine the appropriate timing of initial support installation to find out the balance of tunnel safety and construction cost. Firstly, the global safety factor is introduced as the critical indicator to evaluate tunnel stability. Then, the comprehensive graphic relationship between the global safety factor and the distance to the tunnel face is established. Once the global safety factor decreases to an admissible value, the stability of the surrounding rock is in a critical state and the corresponding distance is the recommended location for installing the initial support. In these procedures, the installation time of the initial support at the typical tunnel section can be quickly designed and fed back by a direct indicator during construction. Meanwhile, several cases with different conditions have been carried out to discuss the regularity of the method.