Qi-Ling Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Qi-Ling Zhang has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Lei Hu
Changjiang River Scientific Research Institute National Center for Dam Safety Engineering Technology Research, Hubei Technology Innovation Center for Smart Hydropower Wuhan
8 shared publicationsChao Hu
Senior Engineer, National Center for Dam Safety Engineering Technology Research, Changjiang River Scientific Research Institute, Wuhan 430010, China
3 shared publications- He-Gao Wu
State Key Laboratory of Water Resources Engineering and Management, Wuhan University, Wuhan 430072, China
3 shared publications - Jikai Zhang
National Center for Dam Safety Engineering Technology Research, Changjiang River Scientific Research Institute, Wuhan, China
3 shared publications - Bo Feng
Huazhong University of Science and Technology
2 shared publications Duan-You Li
Professorate Senior Engineer, Engineering Safety and Disaster Prevention Dept., Changjiang River Scientific Research Institute, Wuhan 430010, China
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (22) , 35027-35034
Time-of-Flight Study for Lift-Off Immune Through-Transmission Eddy Current Testing of Metal Thickness
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (22) , 35027-35034
Time-of-Flight Study for Lift-Off Immune Through-Transmission Eddy Current Testing of Metal Thickness
- 6 August 2026
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Structures and Buildings
- p. 1-20
Stiffness degradation of hydropower house substructures subjected to cyclic water pressure
This study investigates the structural implications for hydropower plants under evolving operational paradigms driven by renewable energy integration, focusing on substructure stiffness degradation caused by cyclic internal water pressure (IWP). A plane axisymmetric finite-element model of the intake section from an actual plant is developed in the Abaqus software program, employing the extended finite-element method to simulate concrete crack initiation and propagation. Numerical results demonstrate that the elastic modulus of the membrane material is the predominant factor influencing substructure stiffness degradation. While the inner reinforcement surrounding the steel spiral case contributes significantly to long-term stiffness retention, the frictional interaction at the steel–concrete interface exerts only a marginal influence when the weld slope-cutting details are considered. Furthermore, the fracture energy of concrete shows no substantial impact on stiffness degradation, provided its value remains within the conventional range for mass concrete (e.g. >150 N/m). Importantly, the numerical analysis indicates that the observed stiffness degradation does not translate into significant adverse effects on two key engineering concerns: generator pedestal uplift and the fatigue life of the steel spiral case. These findings provide critical insights for assessing the long-term performance of hydropower infrastructure under evolving operational demands.
- 6 August 2026
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Structures and Buildings
- p. 1-20
Stiffness degradation of hydropower house substructures subjected to cyclic water pressure
This study investigates the structural implications for hydropower plants under evolving operational paradigms driven by renewable energy integration, focusing on substructure stiffness degradation caused by cyclic internal water pressure (IWP). A plane axisymmetric finite-element model of the intake section from an actual plant is developed in the Abaqus software program, employing the extended finite-element method to simulate concrete crack initiation and propagation. Numerical results demonstrate that the elastic modulus of the membrane material is the predominant factor influencing substructure stiffness degradation. While the inner reinforcement surrounding the steel spiral case contributes significantly to long-term stiffness retention, the frictional interaction at the steel–concrete interface exerts only a marginal influence when the weld slope-cutting details are considered. Furthermore, the fracture energy of concrete shows no substantial impact on stiffness degradation, provided its value remains within the conventional range for mass concrete (e.g. >150 N/m). Importantly, the numerical analysis indicates that the observed stiffness degradation does not translate into significant adverse effects on two key engineering concerns: generator pedestal uplift and the fatigue life of the steel spiral case. These findings provide critical insights for assessing the long-term performance of hydropower infrastructure under evolving operational demands.
- 7 July 2026
- Published by Elsevier in Ocean Engineering
- Vol. 362
Dynamic response characteristics and energy dissipation mechanisms of the miter gate under ship impact
- 7 July 2026
- Published by Elsevier in Ocean Engineering
- Vol. 362
Dynamic response characteristics and energy dissipation mechanisms of the miter gate under ship impact
- 1 July 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
Numerical Simulation of Dynamic Responses of a Radial Gate Under Ship Impact Loadings
Increasing river traffic has led to frequent collisions between uncontrolled ships and hydraulic infrastructures. A dam typically has some spillways for flood-discharge purposes and there is a possibility that one of the gates of the surface spillways is impacted by an uncontrolled ship. This work uses the acoustic–solid coupling method to numerically simulate ship collisions with a radial gate under varying ship speeds and weights. The energy absorption mechanism, load transfer paths, and dynamic responses of the gate are analyzed in different collision scenarios. It is shown that the simulation results with a grid size of 0.2[ ]m are consistent with those with the empirical formula, thus validating the reliability of the employed calculation method. The calculation results indicate that the radial gate mainly undergoes plastic deformation in ship collision events. The longitudinal beams and faceplate of the gate serve as the primary energy-absorbing components while the diagonal braces are crucial for maintaining the structural stability. It is found that a typical load transfer path in the gate in ship collision events is: faceplate [ ] main beams [ ] support arms [ ] hinge supports. The results of this work support the idea that the radial gate has adequate collision resistance in general ship impact events with routine ship speeds and weights.
- 1 July 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
Numerical Simulation of Dynamic Responses of a Radial Gate Under Ship Impact Loadings
Increasing river traffic has led to frequent collisions between uncontrolled ships and hydraulic infrastructures. A dam typically has some spillways for flood-discharge purposes and there is a possibility that one of the gates of the surface spillways is impacted by an uncontrolled ship. This work uses the acoustic–solid coupling method to numerically simulate ship collisions with a radial gate under varying ship speeds and weights. The energy absorption mechanism, load transfer paths, and dynamic responses of the gate are analyzed in different collision scenarios. It is shown that the simulation results with a grid size of 0.2[ ]m are consistent with those with the empirical formula, thus validating the reliability of the employed calculation method. The calculation results indicate that the radial gate mainly undergoes plastic deformation in ship collision events. The longitudinal beams and faceplate of the gate serve as the primary energy-absorbing components while the diagonal braces are crucial for maintaining the structural stability. It is found that a typical load transfer path in the gate in ship collision events is: faceplate [ ] main beams [ ] support arms [ ] hinge supports. The results of this work support the idea that the radial gate has adequate collision resistance in general ship impact events with routine ship speeds and weights.
- 13 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 065115
Magnetic-flux-based plumb line coordinometer for horizontal displacement monitoring of dam
Monitoring the horizontal displacement of plumb lines is essential for guaranteeing the safety of dams. A magnetic-flux-based plumb line coordinometer, which is immune to environmental changes in dust concentration and humidity, is proposed. Firstly, the theoretical relationship between the displacement and the measured magnetic field is derived from the magnetic circuit theory, and the dimensions of the sensor have been optimized. Secondly, the effect of plumb line eccentricity on the displacement measurement is studied and a structure with ferromagnetic guide is proposed to reduce this effect. Finally, a plumb line coordinometer device is fabricated to measure displacements in two orthogonal directions, and a decoupling algorithm is proposed to obtain displacements in two directions. Based on the experimental results, the coordinometer can measure displacement in two orthogonal directions with a maximum error of 0.09 mm within the 60 mm measurement range. The developed plumb line coordinometer has been installed in a hydroelectric power plant for on-site testing, and the displacement measurement results are in good accordance with the optical method and artificial observation.
- 13 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 065115
Magnetic-flux-based plumb line coordinometer for horizontal displacement monitoring of dam
Monitoring the horizontal displacement of plumb lines is essential for guaranteeing the safety of dams. A magnetic-flux-based plumb line coordinometer, which is immune to environmental changes in dust concentration and humidity, is proposed. Firstly, the theoretical relationship between the displacement and the measured magnetic field is derived from the magnetic circuit theory, and the dimensions of the sensor have been optimized. Secondly, the effect of plumb line eccentricity on the displacement measurement is studied and a structure with ferromagnetic guide is proposed to reduce this effect. Finally, a plumb line coordinometer device is fabricated to measure displacements in two orthogonal directions, and a decoupling algorithm is proposed to obtain displacements in two directions. Based on the experimental results, the coordinometer can measure displacement in two orthogonal directions with a maximum error of 0.09 mm within the 60 mm measurement range. The developed plumb line coordinometer has been installed in a hydroelectric power plant for on-site testing, and the displacement measurement results are in good accordance with the optical method and artificial observation.
- 24 December 2023
- Published by Elsevier in Engineering Failure Analysis
- Vol. 157
Fatigue life prediction of steel spiral cases in pumped-storage power plants: Factors to be considered
- 24 December 2023
- Published by Elsevier in Engineering Failure Analysis
- Vol. 157
Fatigue life prediction of steel spiral cases in pumped-storage power plants: Factors to be considered
- 3 August 2021
- Published by Taylor & Francis in Mechanics Based Design of Structures and Machines
- Vol. 51 (8) , 4330-4346
Hydraulic load-bearing mechanism in rib-strengthened steel bifurcation structures of hydroelectric power plants: Numerical simulation
When a penstock serves a water supply purpose for multiple hydrogenerators in a hydroelectric power plant (HPP), a bifurcation structure should be installed between the main pipe and the branch pipes. This study focuses on a rib-strengthened steel bifurcation structure (RSSBS) with an emphasis on its hydraulic load-bearing mechanism. The finite element method is used with the contact and material non-linearities considered. The numerical simulation results agree reasonably well with in-situ measured data. Our research has underlined the critical role of the crescent-shaped rib (CSR) in lessening the stress-concentration at the bifurcation. The CSR is found to separate from the surrounding concrete under the internal water pressure (IWP), thus causing less IWP to be transmitted to the concrete. Despite the fact that the CSR is not in tension-stress-only status, however, the tensile-stress level is well within an acceptable range. In this context, the CSR should not necessarily be in tension-stress-only status, which is recognized as an ideal stress state in the conventional design philosophy. The findings also suggest that the importance of the concrete should not be stressed too much in the structural design of RSSBSs considering its backfilling role.
- 3 August 2021
- Published by Taylor & Francis in Mechanics Based Design of Structures and Machines
- Vol. 51 (8) , 4330-4346
Hydraulic load-bearing mechanism in rib-strengthened steel bifurcation structures of hydroelectric power plants: Numerical simulation
When a penstock serves a water supply purpose for multiple hydrogenerators in a hydroelectric power plant (HPP), a bifurcation structure should be installed between the main pipe and the branch pipes. This study focuses on a rib-strengthened steel bifurcation structure (RSSBS) with an emphasis on its hydraulic load-bearing mechanism. The finite element method is used with the contact and material non-linearities considered. The numerical simulation results agree reasonably well with in-situ measured data. Our research has underlined the critical role of the crescent-shaped rib (CSR) in lessening the stress-concentration at the bifurcation. The CSR is found to separate from the surrounding concrete under the internal water pressure (IWP), thus causing less IWP to be transmitted to the concrete. Despite the fact that the CSR is not in tension-stress-only status, however, the tensile-stress level is well within an acceptable range. In this context, the CSR should not necessarily be in tension-stress-only status, which is recognized as an ideal stress state in the conventional design philosophy. The findings also suggest that the importance of the concrete should not be stressed too much in the structural design of RSSBSs considering its backfilling role.
- 1 July 2021
- Published by Elsevier in Ocean Engineering
- Vol. 232, 109122
Coupled acoustic-structural analysis of a partially submerged circular RC column in an underwater explosion event: Factors to be considered for loading
- 1 July 2021
- Published by Elsevier in Ocean Engineering
- Vol. 232, 109122
Coupled acoustic-structural analysis of a partially submerged circular RC column in an underwater explosion event: Factors to be considered for loading
- Open Access
- 1 January 2020
- Published by Wiley in Advances in Civil Engineering
- Vol. 2020 (1)
Seismic Performance Assessment of Reinforced Concrete Frame‐Shear Wall Structures in Hydropower Plants Based on Material Damage
For the reinforced concrete frame‐shear wall (RCF‐SW) structures in hydropower plants (HPs), the tensile cracking and compressive crushing of the reinforced concrete (RC) members are considered as the main potential damage. This paper presents a methodology to assess the seismic performance of RCF‐SW structures. In this methodology, a concrete damage plasticity model is employed to simulate the reinforced concrete, and the structural seismic responses are investigated through nonlinear incremental dynamic analysis (IDA). Several engineering demand parameters (EDPs) based on the material damage are proposed to identify the structural engineering limit states and damage states at the member level. The case of x HP is provided as an example to illustrate the methodology and discuss the probable nonlinear response and structural damage state. The concrete damage evolution, reinforcement stresses, and drift ratios of the RCF‐SW structure are presented, and the engineering limit states and structural damage states are identified. In comparison with the drift ratio index, the EDPs based on material damage are more suitable for identifying the damage state of the RCF‐SW structure, whose damage is controlled by the damage of the RC members.
- 1 January 2020
- Published by Wiley in Advances in Civil Engineering
- Vol. 2020 (1)
Open AccessSeismic Performance Assessment of Reinforced Concrete Frame‐Shear Wall Structures in Hydropower Plants Based on Material Damage
For the reinforced concrete frame‐shear wall (RCF‐SW) structures in hydropower plants (HPs), the tensile cracking and compressive crushing of the reinforced concrete (RC) members are considered as the main potential damage. This paper presents a methodology to assess the seismic performance of RCF‐SW structures. In this methodology, a concrete damage plasticity model is employed to simulate the reinforced concrete, and the structural seismic responses are investigated through nonlinear incremental dynamic analysis (IDA). Several engineering demand parameters (EDPs) based on the material damage are proposed to identify the structural engineering limit states and damage states at the member level. The case of x HP is provided as an example to illustrate the methodology and discuss the probable nonlinear response and structural damage state. The concrete damage evolution, reinforcement stresses, and drift ratios of the RCF‐SW structure are presented, and the engineering limit states and structural damage states are identified. In comparison with the drift ratio index, the EDPs based on material damage are more suitable for identifying the damage state of the RCF‐SW structure, whose damage is controlled by the damage of the RC members.