Habib Mir-Akbari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Habib Mir-Akbari has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jacek Nowak
Department of Clinical Physiology, Karolinska University Hospital in Huddinge, Stockholm, Sweden
1 shared publication - Jonaz Ripsweden
Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology, Karolinska Institutet, 141 86 Huddinge, Stockholm, Sweden
1 shared publication - Kerstin Cederlund
Department of Clinical Science, Intervention and Technology (CLINTEC) at Karolinska Institutet, Stockholm, Sweden
1 shared publication - Lars-Åke Brodin
School of Technology and Health, Royal Institute of Technology, Huddinge, Sweden
1 shared publication - Mattias Mårtensson
School of Technology and Health, Royal Institute of Technology (KTH), Campus Flemingsberg, Alfred Nobels Allé 10, 141 52 Huddinge, Sweden
1 shared publication - Reidar Winter
Department of Clinical Physiology, Karolinska University Hospital Huddinge, Stockholm, Sweden
1 shared publication
Latest Publications
- Open Access
- 4 June 2008
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 6 (1) , 26
Assessment of left ventricular volumes using simplified 3-D echocardiography and computed tomography – a phantom and clinical study
To compare the accuracy of simplified 3-dimensional (3-D) echocardiography vs. multi-slice computed tomography (MSCT) software for the quantification of left ventricular (LV) volumes. Three-D echocardiography (3-planes approach) and MSCT-CardIQ software were calibrated by measuring known volumes of 10 phantoms designed to closely mimic blood-endocardium interface. Subsequently, LV volumes were measured with both the methods in 9 patients referred routinely for coronary angiography and the agreement between the measurements was evaluated. Simplified 3D-echocardiography provided higher degree of agreement between the measured and true phantom volumes (mean difference 0 +/- 1 ml, variation range +4 to -4 ml) than MSCT software (mean difference 6 +/- 5 ml; variation range +22 to -10 ml). The agreement between LV measurements in the patients was considerably poorer, with significantly larger volumes produced by MSCT (mean difference -23 +/- 40 ml, variation between +93 and -138 ml). Simplified 3-D echocardiography provides more accurate assessment of phantom volumes than MSCT-CardIQ software. The discrepancy between the results of LV measurements with the two methods is even greater and does not warrant their interchangeable diagnostic use.
- 4 June 2008
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 6 (1) , 26
Open AccessAssessment of left ventricular volumes using simplified 3-D echocardiography and computed tomography – a phantom and clinical study
To compare the accuracy of simplified 3-dimensional (3-D) echocardiography vs. multi-slice computed tomography (MSCT) software for the quantification of left ventricular (LV) volumes. Three-D echocardiography (3-planes approach) and MSCT-CardIQ software were calibrated by measuring known volumes of 10 phantoms designed to closely mimic blood-endocardium interface. Subsequently, LV volumes were measured with both the methods in 9 patients referred routinely for coronary angiography and the agreement between the measurements was evaluated. Simplified 3D-echocardiography provided higher degree of agreement between the measured and true phantom volumes (mean difference 0 +/- 1 ml, variation range +4 to -4 ml) than MSCT software (mean difference 6 +/- 5 ml; variation range +22 to -10 ml). The agreement between LV measurements in the patients was considerably poorer, with significantly larger volumes produced by MSCT (mean difference -23 +/- 40 ml, variation between +93 and -138 ml). Simplified 3-D echocardiography provides more accurate assessment of phantom volumes than MSCT-CardIQ software. The discrepancy between the results of LV measurements with the two methods is even greater and does not warrant their interchangeable diagnostic use.