Gaoyang Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gaoyang Guo has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Yunbing Wang
Sichuan University
5 shared publications Wanyu Jin
National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
2 shared publications- Yang Lei
Department of Cardiovascular Medicine, The First Affiliated Hospital, School of Basic Medical Sciences and Institute of Biomedical Innovation, Jiangxi Medical College, Nanchang University, Nanchang, China
2 shared publications Fan Yang
National Engineering Research Center for Biomaterials Sichuan University Chengdu China
1 shared publication- Fan Yang
Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People’s Hospital, Affiliated People’s Hospital, Hangzhou Medical College, Hangzhou, China
1 shared publication - Gaocan Li
National Engineering Research Center for Biomaterials and College of Biomedical Engineering, Sichuan University, Chengdu, 610064, China
1 shared publication
Latest Publications
- 9 July 2021
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 110 (1) , 31-42
Visible light–induced cross‐linking of porcine pericardium for the improvement of endothelialization, anti‐tearing, and anticalcification properties
Population aging and the development of transcatheter aortic valve replacement boost the implantation of bioprosthetic heart valves (BHVs) in patients worldwide. However, the traditional glutaraldehyde cross‐linked BHVs fail within 12–15 years mainly due to leaflet tear and calcification defects. In this study, a novel visible light–induced cross‐linking of the porcine pericardium (PP) was realized by the photo‐oxidation of the furfuryl‐modified PP in the presence of Rose Bengal. The resulting material showed comparable collagen stability with the glutaraldehyde cross‐linked PP and appropriate biomechanical properties such as tensile strength, modulus, and elongation, suggesting that this material could meet the general requirement for BHVs. Besides, this cross‐linked PP showed significantly improved cytocompatibility compared with the Glut–cross‐linked PP, with no cytotoxicity to L929 cells and the ability to support HUVECgrowth. Meanwhile, this material showed superior anti‐tearing performance and much less calcification than the Glut–cross‐linked PP in hope of reducing the risk of BHV failure. Considering these results, the visible light–induced cross‐linking method proposed in this study could provide a promising way to construct a biocompatible and robust biomaterial for the fabrication of the BHV.
- 9 July 2021
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 110 (1) , 31-42
Visible light–induced cross‐linking of porcine pericardium for the improvement of endothelialization, anti‐tearing, and anticalcification properties
Population aging and the development of transcatheter aortic valve replacement boost the implantation of bioprosthetic heart valves (BHVs) in patients worldwide. However, the traditional glutaraldehyde cross‐linked BHVs fail within 12–15 years mainly due to leaflet tear and calcification defects. In this study, a novel visible light–induced cross‐linking of the porcine pericardium (PP) was realized by the photo‐oxidation of the furfuryl‐modified PP in the presence of Rose Bengal. The resulting material showed comparable collagen stability with the glutaraldehyde cross‐linked PP and appropriate biomechanical properties such as tensile strength, modulus, and elongation, suggesting that this material could meet the general requirement for BHVs. Besides, this cross‐linked PP showed significantly improved cytocompatibility compared with the Glut–cross‐linked PP, with no cytotoxicity to L929 cells and the ability to support HUVECgrowth. Meanwhile, this material showed superior anti‐tearing performance and much less calcification than the Glut–cross‐linked PP in hope of reducing the risk of BHV failure. Considering these results, the visible light–induced cross‐linking method proposed in this study could provide a promising way to construct a biocompatible and robust biomaterial for the fabrication of the BHV.
- 2 February 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 9 (10) , 2428-2435
An ultralow dose paclitaxel coated drug balloon with an outer protective sheath for peripheral arterial disease treatment
In this paper, an ultralow dose paclitaxel-coated balloon was developed. Benefiting from the unique design of the meglumine matrix and outer protective sheath, its therapeutic effect was comparable to those of commercial high-dose counterparts in the swine model.
- 2 February 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 9 (10) , 2428-2435
An ultralow dose paclitaxel coated drug balloon with an outer protective sheath for peripheral arterial disease treatment
In this paper, an ultralow dose paclitaxel-coated balloon was developed. Benefiting from the unique design of the meglumine matrix and outer protective sheath, its therapeutic effect was comparable to those of commercial high-dose counterparts in the swine model.
- 18 July 2020
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 109 (5) , 754-765
Inorganic‐polymerization crosslinked tissue‐siloxane hybrid as potential biomaterial for bioprosthetic heart valves
Bioprosthetic heart valve (BHV) replacement is increasingly used for treating valve‐related diseases worldwide but the current commercially used BHVs treated with glutaraldehyde (Glut) often failed within 12–15 years due to degradation, thrombosis, inferior biocompatibility, and calcification. Herein, 3‐glycidyloxypropyl trimethoxysilane (GPTMS) was used to crosslink porcine pericardium (PP) at the concentration (vol/vol) of 0.25%, 1%, 2%, and 4% and their performance for potential application in BHVs was evaluated. The crosslinking mechanism mainly involved the ring‐opening of epoxide by amine attack and silanol poly‐condensation. The stability of collagen in higher concentration (1%, 2%, and 4%) GPTMS crosslinked PPs (GPTMS‐PPs) was clearly increased. GPTMS‐PPs showed no cytotoxicity and supported the growth of endothelial cells while Glut‐PP did not. GPTMS‐PPs were less prothrombotic than Glut‐PP. GPTMS‐PP crosslinked at 1% concentration showed comparable mechanical properties to Glut‐PP while had better anti‐tearing performance. The subcutaneous implantation in rat for 30 days showed that GPTMS crosslinking was able to effectively inhibit the calcification of BHV.
- 18 July 2020
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 109 (5) , 754-765
Inorganic‐polymerization crosslinked tissue‐siloxane hybrid as potential biomaterial for bioprosthetic heart valves
Bioprosthetic heart valve (BHV) replacement is increasingly used for treating valve‐related diseases worldwide but the current commercially used BHVs treated with glutaraldehyde (Glut) often failed within 12–15 years due to degradation, thrombosis, inferior biocompatibility, and calcification. Herein, 3‐glycidyloxypropyl trimethoxysilane (GPTMS) was used to crosslink porcine pericardium (PP) at the concentration (vol/vol) of 0.25%, 1%, 2%, and 4% and their performance for potential application in BHVs was evaluated. The crosslinking mechanism mainly involved the ring‐opening of epoxide by amine attack and silanol poly‐condensation. The stability of collagen in higher concentration (1%, 2%, and 4%) GPTMS crosslinked PPs (GPTMS‐PPs) was clearly increased. GPTMS‐PPs showed no cytotoxicity and supported the growth of endothelial cells while Glut‐PP did not. GPTMS‐PPs were less prothrombotic than Glut‐PP. GPTMS‐PP crosslinked at 1% concentration showed comparable mechanical properties to Glut‐PP while had better anti‐tearing performance. The subcutaneous implantation in rat for 30 days showed that GPTMS crosslinking was able to effectively inhibit the calcification of BHV.
- 23 January 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 7 (9) , 1427-1434
Hydrogel hybrid porcine pericardium for the fabrication of a pre-mounted TAVI valve with improved biocompatibility
Transcatheter aortic valve implantation (TAVI) has been developed years ago for patients who cannot undergo a surgical aortic valve replacement (SAVR). Although TAVI possesses the advantages of lower trauma and simpler manipulation compared to SAVR, the need for storage in glutaraldehyde (GLU) and a tedious intraoperative assembly process have caused great inconvenience for its further application. A pre-mounted TAVI valve assembled by mounting a dry valve frame to a delivery system is expected to address these problems. However, the currently used GLU treated leaflet cannot unfold normally after being crimped for a long-term and loses its function when the BHV is assembled to the catheter. Besides, its cytotoxicity and immune response after implantation are still problems to be solved. In the present study, a hydrogel hybrid porcine pericardium (HHPP) approach was developed to endow the BHVs with a favorable unfolding property and good biocompatibility. Three monomers with different charge characteristics (sodium acrylate, 2-methacryloyloxyethyl phosphorylcholine, and acryloyloxyethyltrimethyl ammonium chloride) were complexed with GLU treated PP (GLU-PP) to form three kinds of HHPPs (SAAH-PP, MPCH-PP, and DACH-PP). The results of the crimping simulation experiment showed that all HHPPs could quickly recover in PBS after being folded for 10 days, while the traditional BHVs (GLU-PP) could not recover under the same conditions. Bovine serum albumin adsorption and platelet adhesion test showed that SAAH-PP and MPCH-PP had good anti-adhesion abilities. A cell culture study indicated that all the three HHPPs promoted HUVEC growth and proliferation. In vivo biocompatibility studies showed that the immune response induced by MPCH-PP was reduced compared to that by GLU-PP. These studies demonstrated that the strategy of MPC hydrogel hybridization may be an effective approach to prepare a pre-mounted TAVI valve with improved biocompatibility.
- 23 January 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 7 (9) , 1427-1434
Hydrogel hybrid porcine pericardium for the fabrication of a pre-mounted TAVI valve with improved biocompatibility
Transcatheter aortic valve implantation (TAVI) has been developed years ago for patients who cannot undergo a surgical aortic valve replacement (SAVR). Although TAVI possesses the advantages of lower trauma and simpler manipulation compared to SAVR, the need for storage in glutaraldehyde (GLU) and a tedious intraoperative assembly process have caused great inconvenience for its further application. A pre-mounted TAVI valve assembled by mounting a dry valve frame to a delivery system is expected to address these problems. However, the currently used GLU treated leaflet cannot unfold normally after being crimped for a long-term and loses its function when the BHV is assembled to the catheter. Besides, its cytotoxicity and immune response after implantation are still problems to be solved. In the present study, a hydrogel hybrid porcine pericardium (HHPP) approach was developed to endow the BHVs with a favorable unfolding property and good biocompatibility. Three monomers with different charge characteristics (sodium acrylate, 2-methacryloyloxyethyl phosphorylcholine, and acryloyloxyethyltrimethyl ammonium chloride) were complexed with GLU treated PP (GLU-PP) to form three kinds of HHPPs (SAAH-PP, MPCH-PP, and DACH-PP). The results of the crimping simulation experiment showed that all HHPPs could quickly recover in PBS after being folded for 10 days, while the traditional BHVs (GLU-PP) could not recover under the same conditions. Bovine serum albumin adsorption and platelet adhesion test showed that SAAH-PP and MPCH-PP had good anti-adhesion abilities. A cell culture study indicated that all the three HHPPs promoted HUVEC growth and proliferation. In vivo biocompatibility studies showed that the immune response induced by MPCH-PP was reduced compared to that by GLU-PP. These studies demonstrated that the strategy of MPC hydrogel hybridization may be an effective approach to prepare a pre-mounted TAVI valve with improved biocompatibility.
- 5 July 2018
- Published by Springer Nature in Journal of Materials Research
- Vol. 33 (17) , 2576-2585
Bioprosthetic heart valves’ structural integrity improvement through exogenous amino donor treatments
- 5 July 2018
- Published by Springer Nature in Journal of Materials Research
- Vol. 33 (17) , 2576-2585
Bioprosthetic heart valves’ structural integrity improvement through exogenous amino donor treatments