Pablo Serrano Galvez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pablo Serrano Galvez has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Mark Butcher
Mechatronics, Robotics and Operations Section (BE-CEM-MRO), European Organization for Nuclear Research (CERN), Meyrin, Geneva, Switzerland
3 shared publications - Mario Di Castro
European Organization for Nuclear Research (CERN), P.O. Box 1211 Geneva, Switzerland
2 shared publications Alessandro Masi
Department of Engineering, CERN, 1211 Geneva, Switzerland
1 shared publication- Alessandro Masi
European Organization for Nuclear Research (CERN), Geneva, Switzerland
1 shared publication - Elisa Guillermain
Universidad Politecnica de Madrid, 28006 Madrid, Spain
1 shared publication - Eloise Matheson
European Organization for Nuclear Research (CERN), Genve, Switzerland
1 shared publication
Latest Publications
- Open Access
- 4 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (22) , 21540-21549
An Inertial Uni-Axial Interferometer-Based Accelerometer for Harsh Environments
For high-impact devices, subsequent vibrations have as much influence on the deterioration of the mechanical structure as the impact itself. To mitigate the consequences of both impacts and resulting vibrations, it is crucial to accurately understand the peak acceleration and vibration frequencies that originate in the structure. In this article, a radiation tolerant opto-mechanical sensor based on an absolute measurement inertial accelerometer is presented. This method of measurement is chosen due to the viability of placing the readout electronics far from the highly radioactive environment that the sensor may be installed in. The designed accelerometer consists of a fixed aluminum frame with a built-in membrane that acts as a leaf spring. In the same membrane, a retro-reflector is attached which acts as a seismic mass. The retro-reflector reflects the light beam coming from the collimator lens placed on the frame. To prove its viability, the device has been tested under different conditions. First, the device is calibrated and validated using a high-frequency exciter. Second, a high-acceleration testbench is used to compare its output signal with a commercial accelerometer and verify its proper operation as well as its expected lifetime. The experimental results showed an average sensitivity of ${9} \times {10}^{-{4}}$ g/pm with reading measurements of up to 5000 g and a working bandwidth located between 50 and 800 Hz.
- 4 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (22) , 21540-21549
Open AccessAn Inertial Uni-Axial Interferometer-Based Accelerometer for Harsh Environments
For high-impact devices, subsequent vibrations have as much influence on the deterioration of the mechanical structure as the impact itself. To mitigate the consequences of both impacts and resulting vibrations, it is crucial to accurately understand the peak acceleration and vibration frequencies that originate in the structure. In this article, a radiation tolerant opto-mechanical sensor based on an absolute measurement inertial accelerometer is presented. This method of measurement is chosen due to the viability of placing the readout electronics far from the highly radioactive environment that the sensor may be installed in. The designed accelerometer consists of a fixed aluminum frame with a built-in membrane that acts as a leaf spring. In the same membrane, a retro-reflector is attached which acts as a seismic mass. The retro-reflector reflects the light beam coming from the collimator lens placed on the frame. To prove its viability, the device has been tested under different conditions. First, the device is calibrated and validated using a high-frequency exciter. Second, a high-acceleration testbench is used to compare its output signal with a commercial accelerometer and verify its proper operation as well as its expected lifetime. The experimental results showed an average sensitivity of ${9} \times {10}^{-{4}}$ g/pm with reading measurements of up to 5000 g and a working bandwidth located between 50 and 800 Hz.
- Open Access
- 23 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 184398-184410
Gamma and Proton Irradiation Tests on a Piezoelectric Actuator
Piezoelectric actuators are candidates for use in radioactive environments but specific radiation tests are necessary to understand the radiation effects on the whole actuator assembly. The results of three irradiation tests on a piezoelectric actuator used for Crystal Collimation are presented. The total ionising dose effects are studied with two Gamma (60Co) Tests up to 10 MGy and 1 MGy, whereas the displacement damage effects are studied in a Proton Test up to 2 MGy and 1.14×1016 p/cm2 fluence. The main results are summarised for each test, presenting a maximum impedance increase of less than 25% (Proton Test), a maximum free stroke reduction of less than 25% (Proton Test) and a variation in the shape of the hysteresis response of the actuator.
- 23 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 184398-184410
Open AccessGamma and Proton Irradiation Tests on a Piezoelectric Actuator
Piezoelectric actuators are candidates for use in radioactive environments but specific radiation tests are necessary to understand the radiation effects on the whole actuator assembly. The results of three irradiation tests on a piezoelectric actuator used for Crystal Collimation are presented. The total ionising dose effects are studied with two Gamma (60Co) Tests up to 10 MGy and 1 MGy, whereas the displacement damage effects are studied in a Proton Test up to 2 MGy and 1.14×1016 p/cm2 fluence. The main results are summarised for each test, presenting a maximum impedance increase of less than 25% (Proton Test), a maximum free stroke reduction of less than 25% (Proton Test) and a variation in the shape of the hysteresis response of the actuator.
- 10 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (3) , 864-873
A Dual-Interferometer-Based Angular Measurement System With Absolute Angle Recovery Method
A dual-interferometer-based angular measurement system is proposed and studied, obtaining analytical expressions for the measured distance of each interferometric axis. The nonzero convexity of the characteristic curve during a rotation is proven to be an intrinsic characteristic of the setup. An absolute angle recovery method is proposed relying on the use of this characteristic curve as an absolute reference to overcome the limitation of the relative operation of conventional interferometric systems. The recovery method is evaluated by Monte Carlo simulations, studying the effect of the noise and the number of points on the performance of the recovery. Finally, the technique is successfully applied to a high-precision rotational stage, where an independent dual-interferometer system is used to experimentally evaluate the performance of the method. The results show an accuracy of ± 1.29 μrad (3σ) in the recovery of the angle, which is in agreement with the Monte Carlo simulations.
- 10 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (3) , 864-873
A Dual-Interferometer-Based Angular Measurement System With Absolute Angle Recovery Method
A dual-interferometer-based angular measurement system is proposed and studied, obtaining analytical expressions for the measured distance of each interferometric axis. The nonzero convexity of the characteristic curve during a rotation is proven to be an intrinsic characteristic of the setup. An absolute angle recovery method is proposed relying on the use of this characteristic curve as an absolute reference to overcome the limitation of the relative operation of conventional interferometric systems. The recovery method is evaluated by Monte Carlo simulations, studying the effect of the noise and the number of points on the performance of the recovery. Finally, the technique is successfully applied to a high-precision rotational stage, where an independent dual-interferometer system is used to experimentally evaluate the performance of the method. The results show an accuracy of ± 1.29 μrad (3σ) in the recovery of the angle, which is in agreement with the Monte Carlo simulations.