Azusa Ishizaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Azusa Ishizaki has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Atsuki Terakawa
Cyclotron and Radioisotope Center, Tohoku University, Sendai 980-8578, Japan
3 shared publications - Keizo Ishii
Cyclotron and Radioisotope Center, Tohoku University, Sendai 980-8578, Japan
3 shared publications - Shigeo Matsuyama
Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Japan
3 shared publications - Fumito Fujishiro
Faculty of Science and Technology, Kochi University, 2-5-1 Akebono-cho, Kochi-shi, Kochi 780-8520, Japan
2 shared publications - Kosuke Kikuchi
Institute of Science Tokyo Nagatsuta-cho 4259, Midori-ku
2 shared publications - Yohei Kikuchi
Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Miyagi 980-8579, Japan
2 shared publications
Latest Publications
- 1 December 2017
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 180, 82-89
Application of topographical source model for air dose rates conversions in aerial radiation monitoring
- 1 December 2017
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 180, 82-89
Application of topographical source model for air dose rates conversions in aerial radiation monitoring
- Open Access
- 28 October 2016
- Published by MDPI AG in Remote Sensing
- Vol. 8 (11) , 892
Investigation of Snow Cover Effects and Attenuation Correction of Gamma Ray in Aerial Radiation Monitoring
In aerial radiation monitoring (ARM), the air dose rate cannot be appropriately estimated under snowy conditions due to attenuation of gamma rays by the snow layer. A technique to address this issue is required for ARM to obtain enough signals for air dose rates. To develop this technique, we investigated the relationship between snow depth and ARM measurement results using ARM, laser imaging detection and ranging, and ground measurement before and after snowfall. From the measured data, the results obtained using three different correction factors were examined and compared. An appropriate correction improved the underestimation of the air dose rate. However, further improvement in the accuracy of the analysis requires accurate estimation of the snow water equivalent.
- 28 October 2016
- Published by MDPI AG in Remote Sensing
- Vol. 8 (11) , 892
Open AccessInvestigation of Snow Cover Effects and Attenuation Correction of Gamma Ray in Aerial Radiation Monitoring
In aerial radiation monitoring (ARM), the air dose rate cannot be appropriately estimated under snowy conditions due to attenuation of gamma rays by the snow layer. A technique to address this issue is required for ARM to obtain enough signals for air dose rates. To develop this technique, we investigated the relationship between snow depth and ARM measurement results using ARM, laser imaging detection and ranging, and ground measurement before and after snowfall. From the measured data, the results obtained using three different correction factors were examined and compared. An appropriate correction improved the underestimation of the air dose rate. However, further improvement in the accuracy of the analysis requires accurate estimation of the snow water equivalent.
- 1 January 2014
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 24 (01n02) , 29-34
Evaluating radiocesium retention ability of root-mat horizon using micro-PIXE analysis
A lot of radiocesium had been deposited onto pastures and grasslands following Fukushima Daiichi Nuclear Power Plant (FDNPP) accident. More radiocesium was accumulated in root-mat horizon than in both above ground plant bodies and mineral soils. In this study, factors causing higher radiocesium concentrations in root-mat horizon were evaluated by the addition of stable cesium solution and particle-induced X-ray emission (PIXE) analysis. Results suggest that adsorption onto root surfaces played a significant role in Cs accumulation in root-mat horizon. Furthermore, absorption of Cs was key to its long-term preservation. The adsorption of Cs by clay minerals also contributed to its retention. A slow water infiltration rate may also affect the enrichment of radiocesium in root-mat horizon. Based on these results, it is concluded that both biotic and abiotic factors contributed to the effective retention of radiocesium in root-mat horizons following the FDNPP accident.
- 1 January 2014
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 24 (01n02) , 29-34
Evaluating radiocesium retention ability of root-mat horizon using micro-PIXE analysis
A lot of radiocesium had been deposited onto pastures and grasslands following Fukushima Daiichi Nuclear Power Plant (FDNPP) accident. More radiocesium was accumulated in root-mat horizon than in both above ground plant bodies and mineral soils. In this study, factors causing higher radiocesium concentrations in root-mat horizon were evaluated by the addition of stable cesium solution and particle-induced X-ray emission (PIXE) analysis. Results suggest that adsorption onto root surfaces played a significant role in Cs accumulation in root-mat horizon. Furthermore, absorption of Cs was key to its long-term preservation. The adsorption of Cs by clay minerals also contributed to its retention. A slow water infiltration rate may also affect the enrichment of radiocesium in root-mat horizon. Based on these results, it is concluded that both biotic and abiotic factors contributed to the effective retention of radiocesium in root-mat horizons following the FDNPP accident.
- 19 July 2013
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 318, 102-104
Remediation of plants contaminated with cesium by aqueous cleaning
- 19 July 2013
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 318, 102-104
Remediation of plants contaminated with cesium by aqueous cleaning
- Open Access
- 13 March 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (7) , 2015-2027
Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles
The pencil-beam algorithm is valid only when elementary Gaussian beams are small enough compared to the lateral heterogeneity of a medium, which is not always true in actual radiotherapy with protons and ions. This work addresses a solution for the problem. We found approximate self-similarity of Gaussian distributions, with which Gaussian beams can split into narrower and deflecting daughter beams when their sizes have overreached lateral heterogeneity in the beam-transport calculation. The effectiveness was assessed in a carbon-ion beam experiment in the presence of steep range compensation, where the splitting calculation reproduced a detour effect amounting to about 10% in dose or as large as the lateral particle disequilibrium effect. The efficiency was analyzed in calculations for carbon-ion and proton radiations with a heterogeneous phantom model, where the beam splitting increased computing times by factors of 4.7 and 3.2. The present method generally improves the accuracy of the pencil-beam algorithm without severe inefficiency. It will therefore be useful for treatment planning and potentially other demanding applications.
- 13 March 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (7) , 2015-2027
Open AccessDynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles
The pencil-beam algorithm is valid only when elementary Gaussian beams are small enough compared to the lateral heterogeneity of a medium, which is not always true in actual radiotherapy with protons and ions. This work addresses a solution for the problem. We found approximate self-similarity of Gaussian distributions, with which Gaussian beams can split into narrower and deflecting daughter beams when their sizes have overreached lateral heterogeneity in the beam-transport calculation. The effectiveness was assessed in a carbon-ion beam experiment in the presence of steep range compensation, where the splitting calculation reproduced a detour effect amounting to about 10% in dose or as large as the lateral particle disequilibrium effect. The efficiency was analyzed in calculations for carbon-ion and proton radiations with a heterogeneous phantom model, where the beam splitting increased computing times by factors of 4.7 and 3.2. The present method generally improves the accuracy of the pencil-beam algorithm without severe inefficiency. It will therefore be useful for treatment planning and potentially other demanding applications.
- 1 November 2006
- Published by World Scientific Pub Co Pte Ltd
- p. 735-741
ACCURACY EVALUATION OF ION BEAM IRRADIATION IN PARTICLE RADIOTHERAPY
- 1 November 2006
- Published by World Scientific Pub Co Pte Ltd
- p. 735-741
ACCURACY EVALUATION OF ION BEAM IRRADIATION IN PARTICLE RADIOTHERAPY