Shigeo Matsuyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shigeo Matsuyama has a total of 243 co-authors. Here are the top co-authors by number of shared publications:
- Keizo Ishii
Cyclotron and Radioisotope Center, Tohoku University, Sendai 980-8578, Japan
18 shared publications - Atsuki Terakawa
Cyclotron and Radioisotope Center, Tohoku University, Sendai 980-8578, Japan
13 shared publications - Misako Miwa
Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Japan
11 shared publications - Sho Toyama
Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, 6-6-01-2 Aoba Aramaki-Aza, Sendai, Miyagi, 980-8579, Japan
11 shared publications - Hirohito Yamazaki
J-PARC Center, Tokai, Ibaraki 319-1195, Japan
10 shared publications - Yohei Kikuchi
Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Miyagi 980-8579, Japan
7 shared publications
Latest Publications
- Open Access
- 4 June 2026
- Published by Elsevier in SSRN Electronic Journal
Evaluation of Optical and Structural Degradation in HfO2/SiO2 Dielectric Mirrors Induced by 1.5 MeV Helium Ion Irradiation
The radiation resistance of dielectric mirrors is a critical requirement for optical components in harsh environments, particularly for the final optics in Inertial Confinement Fusion systems. While neutron-induced damage has been investigated, the specific effects of helium ions, also generated from the fusion plasma, remain less understood. This study investigates the optical and structural degradation mechanisms in HfO2/SiO2 mirrors induced by helium ion irradiation. The mirrors were irradiated at room temperature with 1.5 MeV helium ions to fluences ranging from 1.7 × 1014 to 1.7 × 1017 /cm2. The results reveal two distinct, fluence-dependent damage mechanisms. At the highest fluence (1.7 × 1017 /cm2), an accumulation of helium ions occurred near the multilayer-substrate interface. This accumulation led to the formation of bubbles, which induced large-scale surface undulation and catastrophic delamination of the multilayer coating via an interbubble-fracture mechanism. In contrast, at lower fluences (≤ 1.7 × 1016 /cm2), delamination was not observed. Instead, a fluence-dependent reduction in the multilayer film thickness was observed, indicative of multilayer film densification. This densification reduced the optical path length, thereby causing a blue shift in the reflectance bandwidth. This spectral shift led to a reflectance decrease at the design wavelength, which dropped from 99.9% to 98.1% at the 1.7 × 1016 /cm2 fluence. The results indicate two distinct damage modes in mirrors induced by helium ion irradiation: bubble-induced delamination at high fluences and a decrease in reflectance on the long-wavelength side of the reflection band caused by multilayer densification.
- 4 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEvaluation of Optical and Structural Degradation in HfO2/SiO2 Dielectric Mirrors Induced by 1.5 MeV Helium Ion Irradiation
The radiation resistance of dielectric mirrors is a critical requirement for optical components in harsh environments, particularly for the final optics in Inertial Confinement Fusion systems. While neutron-induced damage has been investigated, the specific effects of helium ions, also generated from the fusion plasma, remain less understood. This study investigates the optical and structural degradation mechanisms in HfO2/SiO2 mirrors induced by helium ion irradiation. The mirrors were irradiated at room temperature with 1.5 MeV helium ions to fluences ranging from 1.7 × 1014 to 1.7 × 1017 /cm2. The results reveal two distinct, fluence-dependent damage mechanisms. At the highest fluence (1.7 × 1017 /cm2), an accumulation of helium ions occurred near the multilayer-substrate interface. This accumulation led to the formation of bubbles, which induced large-scale surface undulation and catastrophic delamination of the multilayer coating via an interbubble-fracture mechanism. In contrast, at lower fluences (≤ 1.7 × 1016 /cm2), delamination was not observed. Instead, a fluence-dependent reduction in the multilayer film thickness was observed, indicative of multilayer film densification. This densification reduced the optical path length, thereby causing a blue shift in the reflectance bandwidth. This spectral shift led to a reflectance decrease at the design wavelength, which dropped from 99.9% to 98.1% at the 1.7 × 1016 /cm2 fluence. The results indicate two distinct damage modes in mirrors induced by helium ion irradiation: bubble-induced delamination at high fluences and a decrease in reflectance on the long-wavelength side of the reflection band caused by multilayer densification.
- Open Access
- 16 January 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 572
Calibration of an electrostatic accelerator for single-event-effects tests
- 16 January 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 572
Open AccessCalibration of an electrostatic accelerator for single-event-effects tests
- Open Access
- 24 June 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (6) , 1-8
Development of a compact microbeam system
We have developed the MB-I and MB-II lines, consisting of quadrupole lenses, object and divergence-defining slits, and integration with IBA techniques for application in multiple fields. The general-purpose type of MB-II, MB-II-AQUA has been used not only at Tohoku University but also in other laboratories. However, the total beamline length is substantial due to the doublet configuration, limiting its introduction in certain laboratory environments. To address this issue, we considered shortening the beamline by implementing a triplet configuration and investigated the impact of shortening the existing MB-II line. Our findings indicate that, even with a reduced object–lens distance, a beam size of approximately 1 μm can be achieved. However, to achieve a beam size smaller than this, the divergence angle must be narrowed. In such cases, doublet configurations proved more advantageous because the effect of spherical aberration was minimized. The performance of the triplet system may vary depending on the laboratory; it is greatly influenced by the brightness distribution of the accelerator. In any case, the triplet system can be easily switched between the doublet and triplet arrangements through wiring and can be adapted for different purposes. As such, the compact MB-II-AQUA-SH microbeam system provides considerable flexibility for various fields and applications.
- 24 June 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (6) , 1-8
Open AccessDevelopment of a compact microbeam system
We have developed the MB-I and MB-II lines, consisting of quadrupole lenses, object and divergence-defining slits, and integration with IBA techniques for application in multiple fields. The general-purpose type of MB-II, MB-II-AQUA has been used not only at Tohoku University but also in other laboratories. However, the total beamline length is substantial due to the doublet configuration, limiting its introduction in certain laboratory environments. To address this issue, we considered shortening the beamline by implementing a triplet configuration and investigated the impact of shortening the existing MB-II line. Our findings indicate that, even with a reduced object–lens distance, a beam size of approximately 1 μm can be achieved. However, to achieve a beam size smaller than this, the divergence angle must be narrowed. In such cases, doublet configurations proved more advantageous because the effect of spherical aberration was minimized. The performance of the triplet system may vary depending on the laboratory; it is greatly influenced by the brightness distribution of the accelerator. In any case, the triplet system can be easily switched between the doublet and triplet arrangements through wiring and can be adapted for different purposes. As such, the compact MB-II-AQUA-SH microbeam system provides considerable flexibility for various fields and applications.
- 1 December 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 32 (01n04) , 15-22
Elemental analysis of NIST SRM air particulate on filter media using four different types of PIXE
To confirm the quantitative accuracy of PIXE analysis instruments, we measured NIST SRM air particles on filter media using different types of PIXE analysis instrument: in-air micro-PIXE, in-air PIXE, in-vacuum PIXE, and in-vacuum micro-PIXE. Then, we compared the measured values with certified values and reference values of NIST SRM. We found that the quantitative values of the NIST SRM filter media measured with each PIXE instrument were within 90% to 110% of the NIST-certified and reference values for most elements. In particular, the quantitative values of major elements ranged from 90% to 110% for the in-air PIXE (Kyoto University), the in-vacuum PIXE, and the in-vacuum micro-PIXE at Tohoku University, and the relative errors are also small. These results will aid in determining the quantitative values of atmospheric particles on filter samples.
- 1 December 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 32 (01n04) , 15-22
Elemental analysis of NIST SRM air particulate on filter media using four different types of PIXE
To confirm the quantitative accuracy of PIXE analysis instruments, we measured NIST SRM air particles on filter media using different types of PIXE analysis instrument: in-air micro-PIXE, in-air PIXE, in-vacuum PIXE, and in-vacuum micro-PIXE. Then, we compared the measured values with certified values and reference values of NIST SRM. We found that the quantitative values of the NIST SRM filter media measured with each PIXE instrument were within 90% to 110% of the NIST-certified and reference values for most elements. In particular, the quantitative values of major elements ranged from 90% to 110% for the in-air PIXE (Kyoto University), the in-vacuum PIXE, and the in-vacuum micro-PIXE at Tohoku University, and the relative errors are also small. These results will aid in determining the quantitative values of atmospheric particles on filter samples.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Application of a Single-Crystal CVD Diamond Detector for Fast Neutron Measurement in High Dose and Mixed Radiation Fields
This paper presents the method to evaluate the fast neutron energy spectrum using the single crystal CVD diamond detector to be applicable on the radiation monitoring in advanced scientific/engineering systems usually characterized with mixed and high-dose radiation field. The pulse shape discrimination based on the shape and the width of a pulse was applied to extract events in which fast neutron hits at the specific depth of the single crystal diamond. Unfolding of the measured spectrum for extracted pulses could deduce the neutron energy spectrum. Experiments using mono-energetic neutron sources demonstrated the reliable capability of this method to evaluate the neutron energy spectrum quantitatively.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Application of a Single-Crystal CVD Diamond Detector for Fast Neutron Measurement in High Dose and Mixed Radiation Fields
This paper presents the method to evaluate the fast neutron energy spectrum using the single crystal CVD diamond detector to be applicable on the radiation monitoring in advanced scientific/engineering systems usually characterized with mixed and high-dose radiation field. The pulse shape discrimination based on the shape and the width of a pulse was applied to extract events in which fast neutron hits at the specific depth of the single crystal diamond. Unfolding of the measured spectrum for extracted pulses could deduce the neutron energy spectrum. Experiments using mono-energetic neutron sources demonstrated the reliable capability of this method to evaluate the neutron energy spectrum quantitatively.
- Open Access
- 19 July 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
Cell-cycle dependence on the biological effects of boron neutron capture therapy and its modification by polyvinyl alcohol
Boron neutron capture therapy (BNCT) is a unique radiotherapy of selectively eradicating tumor cells using boron compounds (e.g., 4-borono-l-phenylalanine [BPA]) that are heterogeneously taken up at the cellular level. Such heterogenicity potentially reduces the curative efficiency. However, the effects of temporospatial heterogenicity on cell killing remain unclear. With the technical combination of radiation track detector and biophysical simulations, this study revealed the cell cycle-dependent heterogenicity of BPA uptake and subsequent biological effects of BNCT on HeLa cells expressing fluorescent ubiquitination-based cell cycle indicators, as well as the modification effects of polyvinyl alcohol (PVA). The results showed that the BPA concentration in the S/G2/M phase was higher than that in the G1/S phase and that PVA enhances the biological effects both by improving the uptake and by canceling the heterogenicity. These findings might contribute to a maximization of therapeutic efficacy when BNCT is combined with PVA and/or cell cycle-specific anticancer agents.
- 19 July 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
Open AccessCell-cycle dependence on the biological effects of boron neutron capture therapy and its modification by polyvinyl alcohol
Boron neutron capture therapy (BNCT) is a unique radiotherapy of selectively eradicating tumor cells using boron compounds (e.g., 4-borono-l-phenylalanine [BPA]) that are heterogeneously taken up at the cellular level. Such heterogenicity potentially reduces the curative efficiency. However, the effects of temporospatial heterogenicity on cell killing remain unclear. With the technical combination of radiation track detector and biophysical simulations, this study revealed the cell cycle-dependent heterogenicity of BPA uptake and subsequent biological effects of BNCT on HeLa cells expressing fluorescent ubiquitination-based cell cycle indicators, as well as the modification effects of polyvinyl alcohol (PVA). The results showed that the BPA concentration in the S/G2/M phase was higher than that in the G1/S phase and that PVA enhances the biological effects both by improving the uptake and by canceling the heterogenicity. These findings might contribute to a maximization of therapeutic efficacy when BNCT is combined with PVA and/or cell cycle-specific anticancer agents.
- 27 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Characterization of CLYC7 Scintillation Detector in Wide Neutron Energy Range for Fusion Neutron Spectroscopy
The newly developed Cs2LiYCl6:Ce crystal with 7Li-enrichment (CLYC7) scintillators had been utilized as a key component in a compact neutron emission spectrometer (CNES) at the Large Helical Device (LHD). The CNES was employed to enhance understanding the slowing-down process of neutral-beam-injected energetic beam deuterons by measuring the Doppler broadening of beam-driven deuterium-deuterium neutrons. In order to assess the detection capabilities in fusion neutron spectroscopy and to gain understanding into the energy spectrum at various neutron energies, a understanding of the response function of the detector across a wide neutron energy range is essential. Therefore, before implementing the CNES at the LHD, the detector was tested at high-performance neutron source facilities to evaluate its response to both thermal and fast neutrons. The detector exhibited excellent pulse shape discrimination properties. However, it also exhibited complexity through the 35Cl(n,p)35S and 35Cl(n,α)32P reactions in the fast neutron measurement. To emphasize the accuracy and reliability of the detector’s response, particularly in the fast neutron energy range, Monte Carlo N-Particle transport simulations were employed. In order to validate the experimental results against the calculations, an energy-dependent quenching factor was determined. This analysis provided a clear understanding of the CLYC7 scintillation detector and its potential in the context of fusion neutron spectroscopy for applications in the LHD and future fusion devices.
- 27 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Characterization of CLYC7 Scintillation Detector in Wide Neutron Energy Range for Fusion Neutron Spectroscopy
The newly developed Cs2LiYCl6:Ce crystal with 7Li-enrichment (CLYC7) scintillators had been utilized as a key component in a compact neutron emission spectrometer (CNES) at the Large Helical Device (LHD). The CNES was employed to enhance understanding the slowing-down process of neutral-beam-injected energetic beam deuterons by measuring the Doppler broadening of beam-driven deuterium-deuterium neutrons. In order to assess the detection capabilities in fusion neutron spectroscopy and to gain understanding into the energy spectrum at various neutron energies, a understanding of the response function of the detector across a wide neutron energy range is essential. Therefore, before implementing the CNES at the LHD, the detector was tested at high-performance neutron source facilities to evaluate its response to both thermal and fast neutrons. The detector exhibited excellent pulse shape discrimination properties. However, it also exhibited complexity through the 35Cl(n,p)35S and 35Cl(n,α)32P reactions in the fast neutron measurement. To emphasize the accuracy and reliability of the detector’s response, particularly in the fast neutron energy range, Monte Carlo N-Particle transport simulations were employed. In order to validate the experimental results against the calculations, an energy-dependent quenching factor was determined. This analysis provided a clear understanding of the CLYC7 scintillation detector and its potential in the context of fusion neutron spectroscopy for applications in the LHD and future fusion devices.