Rob Ijsselsteijn
Rob Ijsselsteijn has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ronny Stolz
Leibniz Institute of Photonic Technology
2 shared publications - Andreas Chwala
Leibniz Institute of Photonic Technology, P.O. Box 100239, Jena D-07702, Germany
1 shared publication - Bastian Schillig
Leibniz Institute of Photonic Technology, Albert-Einstein-Strasse 9, D-07745 Jena, Germany
1 shared publication Hans-Georg Meyer
Supracon AG, Jena, Germany
1 shared publicationLeonie Lina Kaczmarek
Leibniz Institute of Photonic Technology, Jena, Germany
1 shared publicationMatthias Meyer
Supracon AG, Jena, Germany
1 shared publication
Latest Publications
- 27 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (7) , 1-5
Advanced HTS DC SQUIDs with Step-Edge Josephson Junctions for Geophysical Applications
For ground-based electromagnetic methods in geophysics dc superconducting quantum interference devices based on high-temperature superconductors are well suited as magnetic field sensors. Therefore, we introduce in this paper an advanced fabrication technology for high-temperature superconducting dc SQUIDs based on step-edge Josephson junctions. The dc SQUIDs are prepared on structured magnesium-oxide substrates. A trilayer of YBa 2 Cu 3 O 7-x /SrTiO 3 /YBa 2 Cu 3 O 7-x is deposited by pulsed laser deposition and structured with ion beam etching. The galvanometer-type design consists of four different dc SQUIDs directly coupled to a pickup loop. They exhibit large I c R n products and a voltage swing of more than 30 μV. The magnetic field noise amounts to about 20 fT/Hz 1/2 and 35 fT/Hz 1/2 for the white noise region as well as 25 fT/Hz 1/2 and 100 fT/Hz 1/2 at 100 Hz for ac-bias and dc-bias SQUID electronics, respectively. The advanced fabrication process thus enables to produce HTS dc SQUIDs intended for the use in geophysical applications with high throughput.
- 27 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (7) , 1-5
Advanced HTS DC SQUIDs with Step-Edge Josephson Junctions for Geophysical Applications
For ground-based electromagnetic methods in geophysics dc superconducting quantum interference devices based on high-temperature superconductors are well suited as magnetic field sensors. Therefore, we introduce in this paper an advanced fabrication technology for high-temperature superconducting dc SQUIDs based on step-edge Josephson junctions. The dc SQUIDs are prepared on structured magnesium-oxide substrates. A trilayer of YBa 2 Cu 3 O 7-x /SrTiO 3 /YBa 2 Cu 3 O 7-x is deposited by pulsed laser deposition and structured with ion beam etching. The galvanometer-type design consists of four different dc SQUIDs directly coupled to a pickup loop. They exhibit large I c R n products and a voltage swing of more than 30 μV. The magnetic field noise amounts to about 20 fT/Hz 1/2 and 35 fT/Hz 1/2 for the white noise region as well as 25 fT/Hz 1/2 and 100 fT/Hz 1/2 at 100 Hz for ac-bias and dc-bias SQUID electronics, respectively. The advanced fabrication process thus enables to produce HTS dc SQUIDs intended for the use in geophysical applications with high throughput.
- Open Access
An Optically Pumped Magnetometer Working in the Light-Shift Dispersed Mz Mode
We present an optically pumped magnetometer working in a new operational mode—the light-shift dispersed Mz (LSD-Mz) mode. It is realized combining various features; (1) high power off-resonant optical pumping; (2) Mz configuration, where pumping light and magnetic field of interest are oriented parallel to each other; (3) use of small alkali metal vapor cells of identical properties in integrated array structures, where two such cells are pumped by circularly polarized light of opposite helicity; and (4) subtraction of the Mz signals of these two cells. The LSD-Mz magnetometer’s performance depends on the inherent and very complex interplay of input parameters. In order to find the configuration of optimal magnetometer resolution, a sensitivity analysis of the input parameters by means of Latin Hypercube Sampling was carried out. The resulting datasets of the multi-dimensional parameter space exploration were assessed by a subsequent physically reasonable interpretation. Finally, the best shot-noise limited magnetic field resolution was determined within that parameter space. As the result, using two 50 mm3 integrated vapor cells a magnetic field resolution below 10 fT/√Hz at Earth’s magnetic field strength is possible.
Open AccessAn Optically Pumped Magnetometer Working in the Light-Shift Dispersed Mz Mode
We present an optically pumped magnetometer working in a new operational mode—the light-shift dispersed Mz (LSD-Mz) mode. It is realized combining various features; (1) high power off-resonant optical pumping; (2) Mz configuration, where pumping light and magnetic field of interest are oriented parallel to each other; (3) use of small alkali metal vapor cells of identical properties in integrated array structures, where two such cells are pumped by circularly polarized light of opposite helicity; and (4) subtraction of the Mz signals of these two cells. The LSD-Mz magnetometer’s performance depends on the inherent and very complex interplay of input parameters. In order to find the configuration of optimal magnetometer resolution, a sensitivity analysis of the input parameters by means of Latin Hypercube Sampling was carried out. The resulting datasets of the multi-dimensional parameter space exploration were assessed by a subsequent physically reasonable interpretation. Finally, the best shot-noise limited magnetic field resolution was determined within that parameter space. As the result, using two 50 mm3 integrated vapor cells a magnetic field resolution below 10 fT/√Hz at Earth’s magnetic field strength is possible.