Jin-Geun Shon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jin-Geun Shon has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Hyunjae Lee
Department of Electrical Engineering, Gachon University, Seongnam-si 13120, Republic of Korea
9 shared publications - Gildong Kim
Korea Railroad Research Institute, Uiwang-si 16105, Republic of Korea
3 shared publications - Hak-Ryong Moon
Department of Future Technology and Convergence Research, Korea Institute of Civil Engineering and Building Technology, Goyang, Korea
3 shared publications - Hyun-Jae Lee
Department of Electrical Engineering, Gachon University, Seongnam-si, Korea
3 shared publications Dong-Eun Kim
Gachon University
2 shared publications- Gunbok Lee
Smart Electrical and Signaling Division, Korea Railroad Research Institute, Uiwang, Korea
2 shared publications
Latest Publications
- Open Access
Energy Stability Strategy for Photovoltaic DC Energy Systems Using Supercapacitor-Based Ride-Through Control and Required Capacity Sizing
Standalone photovoltaic DC energy systems must maintain bus voltage stability without grid support; however, abrupt load variations can cause a DC-bus voltage drop, reducing system reliability and disturbing connected equipment. Although battery-based energy storage is effective for long-duration power balancing, its response to instantaneous disturbances can be limited. This study proposes an energy stability strategy using supercapacitor-based ride-through control and required capacity sizing for fast DC-bus voltage support. The proposed controller continuously monitors the DC-bus voltage and, when a voltage drop is detected, immediately triggers supercapacitor discharge to compensate for the power deficit until the bus recovers. In addition, a design formulation is derived to estimate the required compensation energy, ride-through time, and minimum capacitance based on the expected power deficit, allowable DC-bus voltage drop, and initial supercapacitor voltage. Simulation results under step changes in load resistance show that the supercapacitor sized by the proposed method maintains the DC-bus voltage close to its reference value within the specified limit. Hardware experiments further validate the ride-through operation and show good agreement between the predicted and measured compensation times.
Open AccessEnergy Stability Strategy for Photovoltaic DC Energy Systems Using Supercapacitor-Based Ride-Through Control and Required Capacity Sizing
Standalone photovoltaic DC energy systems must maintain bus voltage stability without grid support; however, abrupt load variations can cause a DC-bus voltage drop, reducing system reliability and disturbing connected equipment. Although battery-based energy storage is effective for long-duration power balancing, its response to instantaneous disturbances can be limited. This study proposes an energy stability strategy using supercapacitor-based ride-through control and required capacity sizing for fast DC-bus voltage support. The proposed controller continuously monitors the DC-bus voltage and, when a voltage drop is detected, immediately triggers supercapacitor discharge to compensate for the power deficit until the bus recovers. In addition, a design formulation is derived to estimate the required compensation energy, ride-through time, and minimum capacitance based on the expected power deficit, allowable DC-bus voltage drop, and initial supercapacitor voltage. Simulation results under step changes in load resistance show that the supercapacitor sized by the proposed method maintains the DC-bus voltage close to its reference value within the specified limit. Hardware experiments further validate the ride-through operation and show good agreement between the predicted and measured compensation times.
- Open Access
Grid-Frequency-Independent Static Var Compensator Control Using a Synchronous Phase-Carrier with Direct Firing Instant Determination for Leading Load Compensation in Renewable Energy DC Bus
Static var compensators (SVCs) employing thyristor-controlled reactors (TCRs) are widely used to mitigate power-factor degradation by absorbing lagging reactive power. Conventional TCR control schemes use real-time firing-angle calculations, which require intensive computation and make practical real-time implementation difficult, especially under grid frequency variations. To address this issue, this paper proposes a grid-frequency-independent SVC control method based on a synchronous phase carrier technique that directly determines thyristor firing instants without explicit firing-angle calculations. The proposed control strategy uses a carrier signal synchronized with the system phase, enabling real-time TCR operation without relying on nominal grid frequency. The effectiveness of the proposed method is evaluated through simulations and hardware experiments. The results show that the proposed method ensures reliable real-time operation and improves the power factor without requiring firing-angle computation. Furthermore, stable performance under grid-frequency variations confirms the robustness of the proposed method. The proposed approach provides a practical and reliable solution for mitigating power-factor degradation in modern power systems.
Open AccessGrid-Frequency-Independent Static Var Compensator Control Using a Synchronous Phase-Carrier with Direct Firing Instant Determination for Leading Load Compensation in Renewable Energy DC Bus
Static var compensators (SVCs) employing thyristor-controlled reactors (TCRs) are widely used to mitigate power-factor degradation by absorbing lagging reactive power. Conventional TCR control schemes use real-time firing-angle calculations, which require intensive computation and make practical real-time implementation difficult, especially under grid frequency variations. To address this issue, this paper proposes a grid-frequency-independent SVC control method based on a synchronous phase carrier technique that directly determines thyristor firing instants without explicit firing-angle calculations. The proposed control strategy uses a carrier signal synchronized with the system phase, enabling real-time TCR operation without relying on nominal grid frequency. The effectiveness of the proposed method is evaluated through simulations and hardware experiments. The results show that the proposed method ensures reliable real-time operation and improves the power factor without requiring firing-angle computation. Furthermore, stable performance under grid-frequency variations confirms the robustness of the proposed method. The proposed approach provides a practical and reliable solution for mitigating power-factor degradation in modern power systems.
- Open Access
Real-Time Active Control of a Static Volt–Ampere Reactive Compensator for Concurrent Tracking of Grid Phase and Load Variations
This paper proposes a real-time active control strategy for a static volt–ampere reactive compensator (SVC) that can simultaneously respond to source phase variations and load fluctuations. Conventional SVC control schemes based on the total reactive power compensation suffer from degraded power factors and reduced power quality under unbalanced load conditions. In contrast, phase-wise control methods can maintain the power factor during load imbalance, which can result in reactive power overcompensation or undercompensation when source phase variations occur, leading to power factor deterioration. The proposed real-time active SVC control strategy effectively addresses both source phase variations and load fluctuations, thereby improving the power factor and overall power quality. PSIM version 2025 software-based simulations and digital signal processing-based hardware experiments were conducted to validate the effectiveness of the proposed method. The experimental results confirm that the proposed control strategy successfully achieved the target power factor even under simultaneous source phase variations and unbalanced load conditions. These results demonstrate the high applicability of the proposed method to practical industrial power systems and renewable energy-integrated systems. The method is expected to contribute to the efficient design of large-capacity power quality control systems in the future.
Open AccessReal-Time Active Control of a Static Volt–Ampere Reactive Compensator for Concurrent Tracking of Grid Phase and Load Variations
This paper proposes a real-time active control strategy for a static volt–ampere reactive compensator (SVC) that can simultaneously respond to source phase variations and load fluctuations. Conventional SVC control schemes based on the total reactive power compensation suffer from degraded power factors and reduced power quality under unbalanced load conditions. In contrast, phase-wise control methods can maintain the power factor during load imbalance, which can result in reactive power overcompensation or undercompensation when source phase variations occur, leading to power factor deterioration. The proposed real-time active SVC control strategy effectively addresses both source phase variations and load fluctuations, thereby improving the power factor and overall power quality. PSIM version 2025 software-based simulations and digital signal processing-based hardware experiments were conducted to validate the effectiveness of the proposed method. The experimental results confirm that the proposed control strategy successfully achieved the target power factor even under simultaneous source phase variations and unbalanced load conditions. These results demonstrate the high applicability of the proposed method to practical industrial power systems and renewable energy-integrated systems. The method is expected to contribute to the efficient design of large-capacity power quality control systems in the future.
- Open Access
Enhanced Harmonic Reduction and Voltage Utilization Ratio Improvement in ANPC Inverters Using an Advanced Hybrid SVPWM Technique
This paper proposes an Advanced Hybrid SVPWM (Space Vector Pulse Width Modulation) technique that integrates the benefits of RPS-PWM (Reference Point Saturation-Based PWM) and SVPWM to enhance the performance of three-level ANPC (Active Neutral Point Clamped) inverters. While RPS-PWM effectively reduces switching harmonics, it suffers from lower voltage utilization. In contrast, SVPWM achieves higher voltage utilization but struggles with harmonic suppression. The proposed Advanced Hybrid SVPWM technique addresses these limitations by maintaining the voltage utilization level of RPS-PWM while significantly reducing harmonic distortion and increasing the output . To validate the effectiveness of the proposed method, comprehensive PSIM simulations and DSP-based hardware experiments were conducted. Experimental results confirm that the Advanced Hybrid SVPWM achieves superior harmonic suppression compared to conventional RPS-PWM and SVPWM, while also delivering improved output voltage characteristics. These findings highlight the potential of the proposed technique for enhancing the performance of power electronic systems requiring high efficiency and low harmonic distortion.Open AccessEnhanced Harmonic Reduction and Voltage Utilization Ratio Improvement in ANPC Inverters Using an Advanced Hybrid SVPWM Technique
This paper proposes an Advanced Hybrid SVPWM (Space Vector Pulse Width Modulation) technique that integrates the benefits of RPS-PWM (Reference Point Saturation-Based PWM) and SVPWM to enhance the performance of three-level ANPC (Active Neutral Point Clamped) inverters. While RPS-PWM effectively reduces switching harmonics, it suffers from lower voltage utilization. In contrast, SVPWM achieves higher voltage utilization but struggles with harmonic suppression. The proposed Advanced Hybrid SVPWM technique addresses these limitations by maintaining the voltage utilization level of RPS-PWM while significantly reducing harmonic distortion and increasing the output . To validate the effectiveness of the proposed method, comprehensive PSIM simulations and DSP-based hardware experiments were conducted. Experimental results confirm that the Advanced Hybrid SVPWM achieves superior harmonic suppression compared to conventional RPS-PWM and SVPWM, while also delivering improved output voltage characteristics. These findings highlight the potential of the proposed technique for enhancing the performance of power electronic systems requiring high efficiency and low harmonic distortion. - Open Access
Improvement of Power Production Efficiency Following the Application of the GD InC Maximum Power Point Tracking Method in Photovoltaic Systems
This paper proposes a new maximum power point tracking (MPPT) method based on machine learning with improved power production efficiency for application to photovoltaic (PV) systems. Power loss occurs in the incremental conductance (InC) method, depending on the size of the voltage step used to track the maximum power point. Additionally, the size of the voltage step must be specified by the initial user; however, an appropriate size cannot be determined in a rapidly changing environment. To solve this problem, this study presents a gradient descent InC (GD InC) method that optimizes the size of the voltage step by applying an optimization method based on machine learning. The effectiveness of the GD InC method was verified and the optimized size of the voltage step was confirmed to produce the largest amount of power. When the size of the voltage step was optimized, a maximum difference of 4.53% was observed compared with the case when the smallest amount of power was produced. The effectiveness of the GD InC method, which improved the efficiency of power production by optimizing the size of the voltage step, was verified. Power can be produced efficiently by applying the GD InC method to PV systems.
Open AccessImprovement of Power Production Efficiency Following the Application of the GD InC Maximum Power Point Tracking Method in Photovoltaic Systems
This paper proposes a new maximum power point tracking (MPPT) method based on machine learning with improved power production efficiency for application to photovoltaic (PV) systems. Power loss occurs in the incremental conductance (InC) method, depending on the size of the voltage step used to track the maximum power point. Additionally, the size of the voltage step must be specified by the initial user; however, an appropriate size cannot be determined in a rapidly changing environment. To solve this problem, this study presents a gradient descent InC (GD InC) method that optimizes the size of the voltage step by applying an optimization method based on machine learning. The effectiveness of the GD InC method was verified and the optimized size of the voltage step was confirmed to produce the largest amount of power. When the size of the voltage step was optimized, a maximum difference of 4.53% was observed compared with the case when the smallest amount of power was produced. The effectiveness of the GD InC method, which improved the efficiency of power production by optimizing the size of the voltage step, was verified. Power can be produced efficiently by applying the GD InC method to PV systems.
- Open Access
- 10 October 2024
- Published by MDPI AG in Preprints.org
Improvement of Power Production Efficiency Following the Application of the GD InC Maximum Power Point Tracking Method in Photovoltaic Systems
This study proposes a new maximum power point tracking (MPPT) method based on machine learning with improved power production efficiency for application to photovoltaic (PV) systems. Power loss occurs in the incremental conductance (InC) method, depending on the size of the voltage step used to track the maximum power point. Additionally, the size of the voltage step must be specified by the initial user; however, an appropriate size cannot be determined in a rapidly changing environment. To solve this problem, this study presents a gradient descent InC (GD InC) method that optimizes the size of the voltage step by applying an optimization method based on machine learning. The effectiveness of the GD InC method was verified and the optimized size of the voltage step was confirmed to produce the largest amount of power. When the size of the voltage step was optimized, a maximum difference of 4.53% was observed compared to case when the smallest amount of power was produced. The effectiveness of the GD InC method, which improved the efficiency of power production by optimizing the size of the voltage step, was verified. Power can be produced efficiently by applying the GD InC method to PV systems.
- 10 October 2024
- Published by MDPI AG in Preprints.org
Open AccessImprovement of Power Production Efficiency Following the Application of the GD InC Maximum Power Point Tracking Method in Photovoltaic Systems
This study proposes a new maximum power point tracking (MPPT) method based on machine learning with improved power production efficiency for application to photovoltaic (PV) systems. Power loss occurs in the incremental conductance (InC) method, depending on the size of the voltage step used to track the maximum power point. Additionally, the size of the voltage step must be specified by the initial user; however, an appropriate size cannot be determined in a rapidly changing environment. To solve this problem, this study presents a gradient descent InC (GD InC) method that optimizes the size of the voltage step by applying an optimization method based on machine learning. The effectiveness of the GD InC method was verified and the optimized size of the voltage step was confirmed to produce the largest amount of power. When the size of the voltage step was optimized, a maximum difference of 4.53% was observed compared to case when the smallest amount of power was produced. The effectiveness of the GD InC method, which improved the efficiency of power production by optimizing the size of the voltage step, was verified. Power can be produced efficiently by applying the GD InC method to PV systems.
- Open Access
Application and Verification of a Leg-Transfer Method for Three-Level Active Neutral-Point-Clamped Inverters for Railway Vehicles
In this paper, a two-leg-transfer switch structure method that can continuously supply three-phase power even when an accident occurs in a power semiconductor of a three-level active neutral-point-clamped (ANPC) inverter for railway vehicles is presented. The proposed method can minimize the ripple effect caused by power semiconductor faults by separating the faulty leg from the main circuit and connecting the load-side circuit to a neutral point. As a result of simulations, the average values of MAE and RMSE can be reduced by 1.53 [A] and 1.77 [A], respectively, when using the proposed leg-transfer switch structure compared to using the conventional structure. In the IGBT failure experiment, when the proposed method was applied to a three-level ANPC inverter, there was only a 0.21 [%] difference from the THD under normal conditions. As a result, the magnitude, phase, and total harmonic distortion of the three-phase current waveforms measured before and after the fault were identical. Thus, normal three-phase power could be effectively supplied to the load when the proposed leg-transfer switch method was applied after a power semiconductor fault occurred in the three-level ANPC inverter. If this leg-transfer switch method is applied in three-level ANPC inverterd for railway vehicles, track schedule errors can be minimized by continuously supplying three-phase power to the electric motor even when an accident occurs in a power semiconductor.
Open AccessApplication and Verification of a Leg-Transfer Method for Three-Level Active Neutral-Point-Clamped Inverters for Railway Vehicles
In this paper, a two-leg-transfer switch structure method that can continuously supply three-phase power even when an accident occurs in a power semiconductor of a three-level active neutral-point-clamped (ANPC) inverter for railway vehicles is presented. The proposed method can minimize the ripple effect caused by power semiconductor faults by separating the faulty leg from the main circuit and connecting the load-side circuit to a neutral point. As a result of simulations, the average values of MAE and RMSE can be reduced by 1.53 [A] and 1.77 [A], respectively, when using the proposed leg-transfer switch structure compared to using the conventional structure. In the IGBT failure experiment, when the proposed method was applied to a three-level ANPC inverter, there was only a 0.21 [%] difference from the THD under normal conditions. As a result, the magnitude, phase, and total harmonic distortion of the three-phase current waveforms measured before and after the fault were identical. Thus, normal three-phase power could be effectively supplied to the load when the proposed leg-transfer switch method was applied after a power semiconductor fault occurred in the three-level ANPC inverter. If this leg-transfer switch method is applied in three-level ANPC inverterd for railway vehicles, track schedule errors can be minimized by continuously supplying three-phase power to the electric motor even when an accident occurs in a power semiconductor.
- Open Access
Leg Conversion Method for the Continuous Control of a Railway Vehicle Propulsion Inverter
In this study, we propose a whole-leg scheme for the continuous control of a railway vehicle propulsion inverter. The three-leg method is commonly used to obtain the output AC power from the input DC voltage in a railway vehicle propulsion inverter. When the power semiconductor of an inverter operating in a three-leg manner fails, a problem occurs in the power supply. Therefore, this study proposes a method that automatically converts into the two-leg method without replacing the power semiconductor when it fails while the inverter is driven with the three-leg method. This leg conversion method can prevent problems in supplying power by converting the power that can be obtained from an inverter operating with the three-leg method into that obtained from an inverter operating with the two-leg method. In addition, to verify the effectiveness of the leg conversion method, a demonstrative experiment was conducted after a simulation, and an actual inverter was fabricated. Consequently, the experimental results confirmed that in an inverter operating with the three-leg method, even if the power semiconductor failed, it could be converted for operation with the two-leg method to supply power normally.
Open AccessLeg Conversion Method for the Continuous Control of a Railway Vehicle Propulsion Inverter
In this study, we propose a whole-leg scheme for the continuous control of a railway vehicle propulsion inverter. The three-leg method is commonly used to obtain the output AC power from the input DC voltage in a railway vehicle propulsion inverter. When the power semiconductor of an inverter operating in a three-leg manner fails, a problem occurs in the power supply. Therefore, this study proposes a method that automatically converts into the two-leg method without replacing the power semiconductor when it fails while the inverter is driven with the three-leg method. This leg conversion method can prevent problems in supplying power by converting the power that can be obtained from an inverter operating with the three-leg method into that obtained from an inverter operating with the two-leg method. In addition, to verify the effectiveness of the leg conversion method, a demonstrative experiment was conducted after a simulation, and an actual inverter was fabricated. Consequently, the experimental results confirmed that in an inverter operating with the three-leg method, even if the power semiconductor failed, it could be converted for operation with the two-leg method to supply power normally.
- 29 August 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (1) , 687-696
Voltage Sensorless MPPT in a Differential Power Processing Photovoltaic System
- 29 August 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (1) , 687-696
Voltage Sensorless MPPT in a Differential Power Processing Photovoltaic System
- Open Access
Variable Incremental Controller of Permanent-Magnet Synchronous Motor for Voltage-Based Flux-Weakening Control
This study presents a variable incremental controller for flux-weakening control in the high-speed operation area of a permanent-magnetic synchronous motor (PMSM). In general, voltage-based flux-weakening control utilizes a reference voltage and a PI controller to generate a flux component current. In this paper, the voltage-based flux-weakening control is performed using the variable incremental controller instead of the PI controller. The variable incremental controller can control the flux component current using only the maximum speed and maximum current of the motor. A method for properly setting an appropriate variable incremental controller using acceleration is additionally presented. A variable incremental controller is applied and, accordingly, the overshoot of the motor speed can be reduced and the speed error of the motor can be minimized by reducing the difference between the actual motor and targeted accelerations. This method can simplify the design of a controller that utilizes flux-weakening control and can be applied to railroad cars whose acceleration does not alter frequently to increase the effect of motor control.
Open AccessVariable Incremental Controller of Permanent-Magnet Synchronous Motor for Voltage-Based Flux-Weakening Control
This study presents a variable incremental controller for flux-weakening control in the high-speed operation area of a permanent-magnetic synchronous motor (PMSM). In general, voltage-based flux-weakening control utilizes a reference voltage and a PI controller to generate a flux component current. In this paper, the voltage-based flux-weakening control is performed using the variable incremental controller instead of the PI controller. The variable incremental controller can control the flux component current using only the maximum speed and maximum current of the motor. A method for properly setting an appropriate variable incremental controller using acceleration is additionally presented. A variable incremental controller is applied and, accordingly, the overshoot of the motor speed can be reduced and the speed error of the motor can be minimized by reducing the difference between the actual motor and targeted accelerations. This method can simplify the design of a controller that utilizes flux-weakening control and can be applied to railroad cars whose acceleration does not alter frequently to increase the effect of motor control.