HLHyunjae Lee

Hyunjae Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hyunjae Lee has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Grid-Frequency-Independent Static Var Compensator Control Using a Synchronous Phase-Carrier with Direct Firing Instant Determination for Leading Load Compensation in Renewable Energy DC Bus

    by Jongho Lim, Hyunjae Lee, Sungyong Son, Jingeun Shon

    Static var compensators (SVCs) employing thyristor-controlled reactors (TCRs) are widely used to mitigate power-factor degradation by absorbing lagging reactive power. Conventional TCR control schemes use real-time firing-angle calculations, which require intensive computation and make practical real-time implementation difficult, especially under grid frequency variations. To address this issue, this paper proposes a grid-frequency-independent SVC control method based on a synchronous phase carrier technique that directly determines thyristor firing instants without explicit firing-angle calculations. The proposed control strategy uses a carrier signal synchronized with the system phase, enabling real-time TCR operation without relying on nominal grid frequency. The effectiveness of the proposed method is evaluated through simulations and hardware experiments. The results show that the proposed method ensures reliable real-time operation and improves the power factor without requiring firing-angle computation. Furthermore, stable performance under grid-frequency variations confirms the robustness of the proposed method. The proposed approach provides a practical and reliable solution for mitigating power-factor degradation in modern power systems.

  • Open Access

    Enhanced Harmonic Reduction and Voltage Utilization Ratio Improvement in ANPC Inverters Using an Advanced Hybrid SVPWM Technique

    by Gipyo Kim, Hyunjae Lee, Jingeun Shon

    This paper proposes an Advanced Hybrid SVPWM (Space Vector Pulse Width Modulation) technique that integrates the benefits of RPS-PWM (Reference Point Saturation-Based PWM) and SVPWM to enhance the performance of three-level ANPC (Active Neutral Point Clamped) inverters. While RPS-PWM effectively reduces switching harmonics, it suffers from lower voltage utilization. In contrast, SVPWM achieves higher voltage utilization but struggles with harmonic suppression. The proposed Advanced Hybrid SVPWM technique addresses these limitations by maintaining the voltage utilization level of RPS-PWM while significantly reducing harmonic distortion and increasing the output Vrms. To validate the effectiveness of the proposed method, comprehensive PSIM simulations and DSP-based hardware experiments were conducted. Experimental results confirm that the Advanced Hybrid SVPWM achieves superior harmonic suppression compared to conventional RPS-PWM and SVPWM, while also delivering improved output voltage characteristics. These findings highlight the potential of the proposed technique for enhancing the performance of power electronic systems requiring high efficiency and low harmonic distortion.


  • Open Access

    Improvement of Power Production Efficiency Following the Application of the GD InC Maximum Power Point Tracking Method in Photovoltaic Systems

    by Jeongwon Han, Hyunjae Lee, Jingeun Shon

    This paper proposes a new maximum power point tracking (MPPT) method based on machine learning with improved power production efficiency for application to photovoltaic (PV) systems. Power loss occurs in the incremental conductance (InC) method, depending on the size of the voltage step used to track the maximum power point. Additionally, the size of the voltage step must be specified by the initial user; however, an appropriate size cannot be determined in a rapidly changing environment. To solve this problem, this study presents a gradient descent InC (GD InC) method that optimizes the size of the voltage step by applying an optimization method based on machine learning. The effectiveness of the GD InC method was verified and the optimized size of the voltage step was confirmed to produce the largest amount of power. When the size of the voltage step was optimized, a maximum difference of 4.53% was observed compared with the case when the smallest amount of power was produced. The effectiveness of the GD InC method, which improved the efficiency of power production by optimizing the size of the voltage step, was verified. Power can be produced efficiently by applying the GD InC method to PV systems.


  • Open Access

    Improvement of Power Production Efficiency Following the Application of the GD InC Maximum Power Point Tracking Method in Photovoltaic Systems

    by Jeongwon Han, Hyunjae Lee, Jingeun Shon

    This study proposes a new maximum power point tracking (MPPT) method based on machine learning with improved power production efficiency for application to photovoltaic (PV) systems. Power loss occurs in the incremental conductance (InC) method, depending on the size of the voltage step used to track the maximum power point. Additionally, the size of the voltage step must be specified by the initial user; however, an appropriate size cannot be determined in a rapidly changing environment. To solve this problem, this study presents a gradient descent InC (GD InC) method that optimizes the size of the voltage step by applying an optimization method based on machine learning. The effectiveness of the GD InC method was verified and the optimized size of the voltage step was confirmed to produce the largest amount of power. When the size of the voltage step was optimized, a maximum difference of 4.53% was observed compared to case when the smallest amount of power was produced. The effectiveness of the GD InC method, which improved the efficiency of power production by optimizing the size of the voltage step, was verified. Power can be produced efficiently by applying the GD InC method to PV systems.


  • Open Access

    Sensorless MPPT Considering Power Loss Factors for DPP Structure in Photovoltaic Generation System

    by Hyunjae Lee, Jingeun Shon

    This paper presents an effective maximum power point tracking (MPPT) method for photovoltaic (PV) panels without any voltage sensor in a PV differential power processing (DPP) system. If a fault occurs in the voltage sensor, errors will occur in all control methods, including MPPT, thereby reducing power production efficiency. Therefore, this paper presents an effective duty MPPT method that enables normal MPPT, even without the voltage sensor of the DPP converter used in the PV power generation DPP systems. The proposed method performs MPPT by analyzing the power-loss elements of the DPP converter to recalculate the effective duty cycle used for actual power transmission and reduce the voltage calculation error. The effectiveness of the proposed method is verified in simulations and experiments, and the average accuracy compared with the general P&O MPPT is found to be 98.65[%] on average even without the use of a voltage sensor.


  • Open Access

    Proposal and Verification of the Application of an Expert Inference Method to Present the Probability of Lithium-Ion Battery Thermal Runaway Risk

    by Jong Won Shon, Donmook Choi, Hyunjae Lee, Sung-Yong Son

    This study proposes a probabilistic quantification technique that applies an expert inference method to warn of the risk of a fire developing into a thermal runaway when a lithium-ion battery fire occurs. Existing methods have the shortcomings of low prediction accuracy and delayed responses because they determine a fire only by detecting the temperature rise and smoke in a lithium-ion battery to initiate extinguishing activities. To overcome such shortcomings, this study proposes a method to probabilistically calculate the risk of thermal runaway in advance by detecting the amount of off-gases generated in the venting stage before thermal runaway begins. This method has the advantage of quantifying the probability of a fire in advance by applying an expert inference method based on a combination of off-gas amounts, while maintaining high reliability even when the sensor fails. To verify the validity of the risk probability design, problems with the temperature and off-gas increase/decrease data were derived under four SOC conditions in actual lithium-ion batteries. Through the foregoing, it was confirmed that the risk probability can be accurately presented even in situations where the detection sensor malfunctions by applying an expert inference method to calculate the risk probability complexly. Additionally, it was confirmed that the proposed method is a method that can lead to quicker responses to thermal runaway fires.


  • Open Access

    Application and Verification of a Leg-Transfer Method for Three-Level Active Neutral-Point-Clamped Inverters for Railway Vehicles

    by Hyunjae Lee, Gildong Kim, Jingeun Shon

    In this paper, a two-leg-transfer switch structure method that can continuously supply three-phase power even when an accident occurs in a power semiconductor of a three-level active neutral-point-clamped (ANPC) inverter for railway vehicles is presented. The proposed method can minimize the ripple effect caused by power semiconductor faults by separating the faulty leg from the main circuit and connecting the load-side circuit to a neutral point. As a result of simulations, the average values of MAE and RMSE can be reduced by 1.53 [A] and 1.77 [A], respectively, when using the proposed leg-transfer switch structure compared to using the conventional structure. In the IGBT failure experiment, when the proposed method was applied to a three-level ANPC inverter, there was only a 0.21 [%] difference from the THD under normal conditions. As a result, the magnitude, phase, and total harmonic distortion of the three-phase current waveforms measured before and after the fault were identical. Thus, normal three-phase power could be effectively supplied to the load when the proposed leg-transfer switch method was applied after a power semiconductor fault occurred in the three-level ANPC inverter. If this leg-transfer switch method is applied in three-level ANPC inverterd for railway vehicles, track schedule errors can be minimized by continuously supplying three-phase power to the electric motor even when an accident occurs in a power semiconductor.

  • Open Access

    Leg Conversion Method for the Continuous Control of a Railway Vehicle Propulsion Inverter

    by Jongyong Choi, Gildong Kim, Hyunjae Lee, Gunbok Lee, Jingeun Shon

    In this study, we propose a whole-leg scheme for the continuous control of a railway vehicle propulsion inverter. The three-leg method is commonly used to obtain the output AC power from the input DC voltage in a railway vehicle propulsion inverter. When the power semiconductor of an inverter operating in a three-leg manner fails, a problem occurs in the power supply. Therefore, this study proposes a method that automatically converts into the two-leg method without replacing the power semiconductor when it fails while the inverter is driven with the three-leg method. This leg conversion method can prevent problems in supplying power by converting the power that can be obtained from an inverter operating with the three-leg method into that obtained from an inverter operating with the two-leg method. In addition, to verify the effectiveness of the leg conversion method, a demonstrative experiment was conducted after a simulation, and an actual inverter was fabricated. Consequently, the experimental results confirmed that in an inverter operating with the three-leg method, even if the power semiconductor failed, it could be converted for operation with the two-leg method to supply power normally.

  • Open Access

    Non-Integral AC Capacitor Voltage Calculation Method for Shunt Hybrid Active Power Filter

    by Hyunjae Lee, Jingeun Shon

    This paper introduces a novel non-integral method for calculating AC capacitor voltage in shunt hybrid active power filters (SHAPFs). These filters commonly use passive power filters (PPFs) that can introduce voltage containing harmonics into the AC capacitor, leading to overvoltage situations that can be dangerous. To avoid accidents due to overvoltage, it is necessary to monitor the AC capacitor voltage continuously. The proposed method enables the calculation of the voltage across the AC capacitor, using only the sensor available in the SHAPF, without requiring additional sensors. By avoiding the use of integration to calculate the voltage, the method effectively mitigates errors due to DC offset inflows. The effectiveness of the proposed method was verified through simulations and actual experiments. Results demonstrate that the proposed voltage calculation method improves the voltage calculation accuracy by approximately 1.93[%] when compared to the general voltage calculation method. The proposed non-integral AC capacitor voltage calculation method represents a significant advancement for SHAPFs, providing an effective means for reducing overvoltage risks, without requiring additional sensors or costly equipment.


  • Open Access

    Sensorless AC Capacitor Voltage Monitoring Method for HAPF

    by Hyunjae Lee, Jingeun Shon

    This study presents a method for monitoring the voltage across the AC capacitor in a grid-connected hybrid active power filter without the use of additional voltage sensors. In the case of an AC capacitor used in a hybrid, active power filter, there is a risk of burnout caused by exceeding the allowable voltage owing to the harmonic current and voltage generated by the inverter. Therefore, this study presents a method to monitor the voltage of the AC capacitor using the current from which the DC component has been removed without any additional voltage sensors to prevent the burn-out of the AC capacitor. The proposed sensorless AC capacitor voltage monitoring method is verified through simulations and experiments. The difference between the magnitude of the voltage measured in the simulations and experiments and the magnitude of the voltage predicted with the proposed method was approximately 0.526[%] on average.