Etienne Lemaire
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Etienne Lemaire has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Danick Briand
Ecole Polytechnique Fédérale de Lausanne (EPFL), Soft Transducers Laboratory (LMTS), Rue de la Maladière 71b, Neuchâtel, Switzerland.
2 shared publications - Laurent Thiery
FEMTO-ST Institute, UMR 6174, Université de Franche-Comté, CNRS, ENSMM, UTBM, Besançon 25030, France
2 shared publications - Pascal Vairac
FEMTO-ST Institute, UMR 6174, Université de Franche-Comté, CNRS, ENSMM, UTBM, Besançon 25030, France
2 shared publications - Lionel Aigouy
Laboratoire de Physique et d’Etude des Matériaux (LPEM), ESPCI Paris, PSL University, Sorbonne Université, CNRS UMR 8213, 10 Rue Vauquelin, F-75005 Paris, France
1 shared publication - Saleem Khan
College of Science and Engineering, Hamad Bin Khalifa University, Qatar Foundation, Doha 5825, Qatar
1 shared publication - Sébastien Euphrasie
Institut FEMTO-ST, UMR 6174, CNRS, ENSMM, Univ. Bourgogne Franche-Comté, 15B, Avenue des Montboucons, 25030 BESANCON Cedex, France
1 shared publication
Latest Publications
- 14 May 2019
- Published by Wiley in Journal of Heat Transfer
- Vol. 141 (7)
Calibration Tools for Scanning Thermal Microscopy Probes Used in Temperature Measurement Mode
We demonstrate the functionality of a new active thermal microchip dedicated to the temperature calibration of scanning thermal microscopy (SThM) probes. The silicon micromachined device consists in a suspended thin dielectric membrane in which a heating resistor with a circular area of 50 μm in diameter was embedded. A circular calibration target of 10 μm in diameter was patterned at the center and on top of the membrane on which the SThM probe can land. This target is a resistive temperature detector (RTD) that measures the surface temperature of the sample at the level of the contact area. This allows evaluating the ability of any SThM probe to measure a surface temperature in ambient air conditions. Furthermore, by looking at the thermal balance of the device, the heat dissipated through the probe and the different thermal resistances involved at the contact can be estimated. A comparison of the results obtained for two different SThM probes, microthermocouples and probes with a fluorescent particle is presented to validate the functionality of the micromachined device. Based on experiments and simulations, an analysis of the behavior of probes allows pointing out their performances and limits depending on the sample characteristics whose role is always preponderant. Finally, we also show that a smaller area of the temperature sensor would be required to assess the local disturbance at the contact point.
- 14 May 2019
- Published by Wiley in Journal of Heat Transfer
- Vol. 141 (7)
Calibration Tools for Scanning Thermal Microscopy Probes Used in Temperature Measurement Mode
We demonstrate the functionality of a new active thermal microchip dedicated to the temperature calibration of scanning thermal microscopy (SThM) probes. The silicon micromachined device consists in a suspended thin dielectric membrane in which a heating resistor with a circular area of 50 μm in diameter was embedded. A circular calibration target of 10 μm in diameter was patterned at the center and on top of the membrane on which the SThM probe can land. This target is a resistive temperature detector (RTD) that measures the surface temperature of the sample at the level of the contact area. This allows evaluating the ability of any SThM probe to measure a surface temperature in ambient air conditions. Furthermore, by looking at the thermal balance of the device, the heat dissipated through the probe and the different thermal resistances involved at the contact can be estimated. A comparison of the results obtained for two different SThM probes, microthermocouples and probes with a fluorescent particle is presented to validate the functionality of the micromachined device. Based on experiments and simulations, an analysis of the behavior of probes allows pointing out their performances and limits depending on the sample characteristics whose role is always preponderant. Finally, we also show that a smaller area of the temperature sensor would be required to assess the local disturbance at the contact point.
- Open Access
- 25 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 334
Low-Power Heating Platform for the Characterization and Calibration of Scanning Thermal Probes
We report on a micro-hotplate technology platform optimized for the calibration of Scanning Thermal Microscopy probes (SThM) used in surface temperature measurement mode. The three chips designed include the same heating area with a calibration area of 10 × 10 µm2 where the SThM probes can land. The 1st design allows to study the influence of the nature of the material on the SThM probes thermal contact resistance. The 2nd design includes a resistive temperature sensor (RTD) integrated on the contact area, which is dedicated to evaluate the capability of a probe to measure a surface temperature. The 3rd design has a contact area made of a suspended platinum membrane for coupling SThM probes with optical thermal measurements. The thermal response of a thermocouple (TC) SThM probe was extracted demonstrating the relevance of these chips for SThM probes characterization and calibration.
- 25 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 334
Open AccessLow-Power Heating Platform for the Characterization and Calibration of Scanning Thermal Probes
We report on a micro-hotplate technology platform optimized for the calibration of Scanning Thermal Microscopy probes (SThM) used in surface temperature measurement mode. The three chips designed include the same heating area with a calibration area of 10 × 10 µm2 where the SThM probes can land. The 1st design allows to study the influence of the nature of the material on the SThM probes thermal contact resistance. The 2nd design includes a resistive temperature sensor (RTD) integrated on the contact area, which is dedicated to evaluate the capability of a probe to measure a surface temperature. The 3rd design has a contact area made of a suspended platinum membrane for coupling SThM probes with optical thermal measurements. The thermal response of a thermocouple (TC) SThM probe was extracted demonstrating the relevance of these chips for SThM probes characterization and calibration.