Laurent Thiery
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laurent Thiery has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Danick Briand
Ecole Polytechnique Fédérale de Lausanne (EPFL), Soft Transducers Laboratory (LMTS), Rue de la Maladière 71b, Neuchâtel, Switzerland.
3 shared publications - Pascal Vairac
FEMTO-ST Institute, UMR 6174, Université de Franche-Comté, CNRS, ENSMM, UTBM, Besançon 25030, France
3 shared publications - Etienne Lemaire
Ecole Polytechnique Fédérale de Lausanne, Soft Transducers Laboratory, Neuchâtel CH-2002, Switzerland
2 shared publications J.Y. Rauch
2 shared publications- Saleem Khan
College of Science and Engineering, Hamad Bin Khalifa University, Qatar Foundation, Doha 5825, Qatar
2 shared publications - Sébastien Euphrasie
Institut FEMTO-ST, UMR 6174, CNRS, ENSMM, Univ. Bourgogne Franche-Comté, 15B, Avenue des Montboucons, 25030 BESANCON Cedex, France
2 shared publications
Latest Publications
- 20 September 2023
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 195
High resolution surface contact temperature measurements by means of micro-thermocouples in vacuum conditions
- 20 September 2023
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 195
High resolution surface contact temperature measurements by means of micro-thermocouples in vacuum conditions
- 1 November 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (11) , 114901
Calibration of thermocouple-based scanning thermal microscope in active mode (2ω method)
We present a procedure dedicated to the calibration of a scanning thermal microscopy probe operated in an active mode and a modulated regime especially for the measurement of solid material thermal conductivities. The probe used is a microthermocouple wire mounted on a quartz tuning fork. Measurements on reference samples are performed successively in vacuum and ambient air conditions revealing a clear difference in the dependence of the thermal interaction between the probe and the sample on the sample properties. Analytical modeling based on the resolution of the heat equation in the wire probe and a description of the thermal interaction using a network of thermal conductances are used to fit experimental data and analyze this difference. We have experimentally verified that the effective thermal contact radius of the probe tip depends on the sample thermal conductivity in ambient conditions, whereas it remains constant in vacuum. We have defined the measurement range of the technique based on the decrease in the probe sensitivity at high thermal conductivities. Considering the experimental noise of our electrical device, it is shown that the maximum measurable value of thermal conductivity is near 23 W m−1 K−1 in vacuum and 37 W m−1 K−1 in ambient air conditions. Moreover, the lowest uncertainties are obtained for thermal conductivities below 5 W m−1 K−1 typically.
- 1 November 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (11) , 114901
Calibration of thermocouple-based scanning thermal microscope in active mode (2ω method)
We present a procedure dedicated to the calibration of a scanning thermal microscopy probe operated in an active mode and a modulated regime especially for the measurement of solid material thermal conductivities. The probe used is a microthermocouple wire mounted on a quartz tuning fork. Measurements on reference samples are performed successively in vacuum and ambient air conditions revealing a clear difference in the dependence of the thermal interaction between the probe and the sample on the sample properties. Analytical modeling based on the resolution of the heat equation in the wire probe and a description of the thermal interaction using a network of thermal conductances are used to fit experimental data and analyze this difference. We have experimentally verified that the effective thermal contact radius of the probe tip depends on the sample thermal conductivity in ambient conditions, whereas it remains constant in vacuum. We have defined the measurement range of the technique based on the decrease in the probe sensitivity at high thermal conductivities. Considering the experimental noise of our electrical device, it is shown that the maximum measurable value of thermal conductivity is near 23 W m−1 K−1 in vacuum and 37 W m−1 K−1 in ambient air conditions. Moreover, the lowest uncertainties are obtained for thermal conductivities below 5 W m−1 K−1 typically.
- 14 May 2019
- Published by Wiley in Journal of Heat Transfer
- Vol. 141 (7)
Calibration Tools for Scanning Thermal Microscopy Probes Used in Temperature Measurement Mode
We demonstrate the functionality of a new active thermal microchip dedicated to the temperature calibration of scanning thermal microscopy (SThM) probes. The silicon micromachined device consists in a suspended thin dielectric membrane in which a heating resistor with a circular area of 50 μm in diameter was embedded. A circular calibration target of 10 μm in diameter was patterned at the center and on top of the membrane on which the SThM probe can land. This target is a resistive temperature detector (RTD) that measures the surface temperature of the sample at the level of the contact area. This allows evaluating the ability of any SThM probe to measure a surface temperature in ambient air conditions. Furthermore, by looking at the thermal balance of the device, the heat dissipated through the probe and the different thermal resistances involved at the contact can be estimated. A comparison of the results obtained for two different SThM probes, microthermocouples and probes with a fluorescent particle is presented to validate the functionality of the micromachined device. Based on experiments and simulations, an analysis of the behavior of probes allows pointing out their performances and limits depending on the sample characteristics whose role is always preponderant. Finally, we also show that a smaller area of the temperature sensor would be required to assess the local disturbance at the contact point.
- 14 May 2019
- Published by Wiley in Journal of Heat Transfer
- Vol. 141 (7)
Calibration Tools for Scanning Thermal Microscopy Probes Used in Temperature Measurement Mode
We demonstrate the functionality of a new active thermal microchip dedicated to the temperature calibration of scanning thermal microscopy (SThM) probes. The silicon micromachined device consists in a suspended thin dielectric membrane in which a heating resistor with a circular area of 50 μm in diameter was embedded. A circular calibration target of 10 μm in diameter was patterned at the center and on top of the membrane on which the SThM probe can land. This target is a resistive temperature detector (RTD) that measures the surface temperature of the sample at the level of the contact area. This allows evaluating the ability of any SThM probe to measure a surface temperature in ambient air conditions. Furthermore, by looking at the thermal balance of the device, the heat dissipated through the probe and the different thermal resistances involved at the contact can be estimated. A comparison of the results obtained for two different SThM probes, microthermocouples and probes with a fluorescent particle is presented to validate the functionality of the micromachined device. Based on experiments and simulations, an analysis of the behavior of probes allows pointing out their performances and limits depending on the sample characteristics whose role is always preponderant. Finally, we also show that a smaller area of the temperature sensor would be required to assess the local disturbance at the contact point.
- Open Access
- 25 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 334
Low-Power Heating Platform for the Characterization and Calibration of Scanning Thermal Probes
We report on a micro-hotplate technology platform optimized for the calibration of Scanning Thermal Microscopy probes (SThM) used in surface temperature measurement mode. The three chips designed include the same heating area with a calibration area of 10 × 10 µm2 where the SThM probes can land. The 1st design allows to study the influence of the nature of the material on the SThM probes thermal contact resistance. The 2nd design includes a resistive temperature sensor (RTD) integrated on the contact area, which is dedicated to evaluate the capability of a probe to measure a surface temperature. The 3rd design has a contact area made of a suspended platinum membrane for coupling SThM probes with optical thermal measurements. The thermal response of a thermocouple (TC) SThM probe was extracted demonstrating the relevance of these chips for SThM probes characterization and calibration.
- 25 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 334
Open AccessLow-Power Heating Platform for the Characterization and Calibration of Scanning Thermal Probes
We report on a micro-hotplate technology platform optimized for the calibration of Scanning Thermal Microscopy probes (SThM) used in surface temperature measurement mode. The three chips designed include the same heating area with a calibration area of 10 × 10 µm2 where the SThM probes can land. The 1st design allows to study the influence of the nature of the material on the SThM probes thermal contact resistance. The 2nd design includes a resistive temperature sensor (RTD) integrated on the contact area, which is dedicated to evaluate the capability of a probe to measure a surface temperature. The 3rd design has a contact area made of a suspended platinum membrane for coupling SThM probes with optical thermal measurements. The thermal response of a thermocouple (TC) SThM probe was extracted demonstrating the relevance of these chips for SThM probes characterization and calibration.
- Open Access
- 17 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 316
Aerosol Jet Printing of Miniaturized, Low Power Flexible Micro-Hotplates
We report on printed flexible micro-hotplates operating at high temperature at lower power consμmption than ever reported using aerosol jet printing of fine metallic conductor features. Efficient heating (i.e., 40 mW at 325 °C) was produced by reducing the effective heating area and substrates thickness. Gold (Au) nanoparticles solution was used for printing micro-hotplates of two different sizes, i.e., 500 × 500 μm2 and 300 × 300 μm2, on 50 μm- and 13 μm-thick PI substrates, respectively. Comsol simulations were used to optimize the thermal design of micro-hotplates. Their power consμmption at 325 °C was of 54 mW for the large hotplate and of 40 mW for the smaller design. These results validate the simple manufacturing of high temperature and power efficient flexible micro-hotplates for applications such as in portable gas and chemical sensors, thermal metrology, etc.
- 17 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 316
Open AccessAerosol Jet Printing of Miniaturized, Low Power Flexible Micro-Hotplates
We report on printed flexible micro-hotplates operating at high temperature at lower power consμmption than ever reported using aerosol jet printing of fine metallic conductor features. Efficient heating (i.e., 40 mW at 325 °C) was produced by reducing the effective heating area and substrates thickness. Gold (Au) nanoparticles solution was used for printing micro-hotplates of two different sizes, i.e., 500 × 500 μm2 and 300 × 300 μm2, on 50 μm- and 13 μm-thick PI substrates, respectively. Comsol simulations were used to optimize the thermal design of micro-hotplates. Their power consμmption at 325 °C was of 54 mW for the large hotplate and of 40 mW for the smaller design. These results validate the simple manufacturing of high temperature and power efficient flexible micro-hotplates for applications such as in portable gas and chemical sensors, thermal metrology, etc.
- 3 July 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (9) , 091601
Thermal Contact Calibration Between a Thermocouple Probe and a Microhotplate
Since local thermal probing has become a major tool for studying transport phenomena at micro- and nanoscale levels, the fundamental aspect of the interaction between the tip of the probe and the sample has remained the key point on which any quantitative measurement relies. In this paper, we present results on thermal resistances involved in the contact mechanism of a microthermocouple cantilever probe that is used to scan the surface of a microhotplate at different levels of temperature. We point out the potential of such an active microsystem as an efficient calibration tool for near-field thermal probes.
- 3 July 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (9) , 091601
Thermal Contact Calibration Between a Thermocouple Probe and a Microhotplate
Since local thermal probing has become a major tool for studying transport phenomena at micro- and nanoscale levels, the fundamental aspect of the interaction between the tip of the probe and the sample has remained the key point on which any quantitative measurement relies. In this paper, we present results on thermal resistances involved in the contact mechanism of a microthermocouple cantilever probe that is used to scan the surface of a microhotplate at different levels of temperature. We point out the potential of such an active microsystem as an efficient calibration tool for near-field thermal probes.
- 1 July 2002
- Published by Elsevier in Ultramicroscopy
- Vol. 94 (1) , 49-69
Thermal behaviour modelling of tapered optical fibres for scanning near-field microscopy
- 1 July 2002
- Published by Elsevier in Ultramicroscopy
- Vol. 94 (1) , 49-69
Thermal behaviour modelling of tapered optical fibres for scanning near-field microscopy
- 1 April 1994
- Published by Elsevier in Optics Communications
- Vol. 107 (3-4) , 309-317
Performance limits of microthermocouples as opto-thermal sensors
- 1 April 1994
- Published by Elsevier in Optics Communications
- Vol. 107 (3-4) , 309-317
Performance limits of microthermocouples as opto-thermal sensors