David Allen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David Allen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Andreas N. Danilewsky
D-79108 Freiburg, Germany
1 shared publication - Brian K. Tanner
Durham University (Durham, United Kingdom)
1 shared publication - Eider Gorostegui-Colinas
IK4-Lortek (Spain)
1 shared publication - Jochen Wittge
Straumann GmbH, 79100 Freiburg, Germany
1 shared publication - Jorge Garagorri
CEIT and Tecnun (University of Navarra), Paseo de Manuel Lardizabal 15, San Sebastián 20018, Spain
1 shared publication - Maria Reyes Elizalde
CEIT and Tecnun (University of Navarra), Paseo de Manuel Lardizabal 15, 20018 San Sebastián, Spain
1 shared publication
Latest Publications
- Open Access
Quantitative Imaging of the Stress/Strain Fields and Generation of Macroscopic Cracks from Indents in Silicon
The crack geometry and associated strain field around Berkovich and Vickers indents on silicon have been studied by X-ray diffraction imaging and micro-Raman spectroscopy scanning. The techniques are complementary; the Raman data come from within a few micrometres of the indentation, whereas the X-ray image probes the strain field at a distance of typically tens of micrometres. For example, Raman data provide an explanation for the central contrast feature in the X-ray images of an indent. Strain relaxation from breakout and high temperature annealing are examined and it is demonstrated that millimetre length cracks, similar to those produced by mechanical damage from misaligned handling tools, can be generated in a controlled fashion by indentation within 75 micrometres of the bevel edge of 200 mm diameter wafers.
Open AccessQuantitative Imaging of the Stress/Strain Fields and Generation of Macroscopic Cracks from Indents in Silicon
The crack geometry and associated strain field around Berkovich and Vickers indents on silicon have been studied by X-ray diffraction imaging and micro-Raman spectroscopy scanning. The techniques are complementary; the Raman data come from within a few micrometres of the indentation, whereas the X-ray image probes the strain field at a distance of typically tens of micrometres. For example, Raman data provide an explanation for the central contrast feature in the X-ray images of an indent. Strain relaxation from breakout and high temperature annealing are examined and it is demonstrated that millimetre length cracks, similar to those produced by mechanical damage from misaligned handling tools, can be generated in a controlled fashion by indentation within 75 micrometres of the bevel edge of 200 mm diameter wafers.