Yong Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yong Wang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Jing Liu
Electric Power Test and Research Institute, Guangzhou Power Supply Co. Ltd., Guangzhou 510410, China
2 shared publications - Lian Zeng
Electric Power Test and Research Institute, Guangzhou Power Supply Co. Ltd., Guangzhou 510410, China
2 shared publications - Yaru Zhang
Electric Power Test and Research Institute, Guangzhou Power Supply Co. Ltd., Guangzhou 510410, China
2 shared publications - Danqing Huang
Electric Power Test and Research Institute, Guangzhou Power Supply Co. Ltd., Guangzhou 510410, China
1 shared publication - Fating Yuan
College of Electrical Engineering and New Energy, China Three Gorges University, Yichang, China + Hubei Provincial Engineering Technology Research Center for Power Transmission Line, China Three Gorges University, Yichang, China
1 shared publication - Haibo Su
Electric Power Research Institute, Guangzhou Power Supply Bureau, Guangdong Power Grid Company, Ltd., Guangzhou, China
1 shared publication
Latest Publications
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (6) , 3419-3429
Modeling of X-ray Radiation of High-Voltage Vacuum Interrupters and Experimental Verification
The X-ray generated by vacuum interrupters (VIs) has received increasing attention as VIs develop towards higher voltage level. In this paper, a model is proposed to simulate the X-ray generation and transport in VIs based on measured voltage and current, which considers the electron field emission and acceleration, the bremsstrahlung, and the interaction between X-ray and material, enabling the calculation of X-ray dose and spectrum. Experimental measurements were then conducted on 126 kV and 252 kV VIs during power frequency voltage tests to verify the model, including the longitudinal and angular dose distribution, and the X-ray dose and spectrum using a custom-designed absorption spectrometer. For both VIs, the calculated X-ray spectrum shows more than 93% similarity compared to the measurement, and the calculated dose value shows about 35% negative deviation. By considering charge accumulation on the shield, which notably alertes the electron trajectories, the dose deviation was reduced to below 30%. This study aims to provide a foundation for further in-depth investigation of X-ray characteristics and effects in high-voltage vacuum interrupters.
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (6) , 3419-3429
Modeling of X-ray Radiation of High-Voltage Vacuum Interrupters and Experimental Verification
The X-ray generated by vacuum interrupters (VIs) has received increasing attention as VIs develop towards higher voltage level. In this paper, a model is proposed to simulate the X-ray generation and transport in VIs based on measured voltage and current, which considers the electron field emission and acceleration, the bremsstrahlung, and the interaction between X-ray and material, enabling the calculation of X-ray dose and spectrum. Experimental measurements were then conducted on 126 kV and 252 kV VIs during power frequency voltage tests to verify the model, including the longitudinal and angular dose distribution, and the X-ray dose and spectrum using a custom-designed absorption spectrometer. For both VIs, the calculated X-ray spectrum shows more than 93% similarity compared to the measurement, and the calculated dose value shows about 35% negative deviation. By considering charge accumulation on the shield, which notably alertes the electron trajectories, the dose deviation was reduced to below 30%. This study aims to provide a foundation for further in-depth investigation of X-ray characteristics and effects in high-voltage vacuum interrupters.
- 10 March 2023
- Published by Springer Nature
- p. 953-957
Research on Mechanism and Algorithm of Squall Line Wind Early Warning on Transmission Line
- 10 March 2023
- Published by Springer Nature
- p. 953-957
Research on Mechanism and Algorithm of Squall Line Wind Early Warning on Transmission Line
- 10 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (8) , 1-5
Design Improvement of Fault Current Limiter Based on High Coupled Split Reactor Considering the Impact of Internal Ground Fault
The fault current limiter (FCL) based on high coupled split reactor (HCSR), namely HCSR-FCL, is a new technology developed in recent years to realize short-circuit current suppression and interruption. This paper investigates the impact of the internal ground fault on the HCSR-FCL, based on the analysis of its basic principle and internal structure, and proposes two improved schemes for the wiring mode and the current-transformer (CT) configuration. Through the theoretical and simulation analysis, the performance of the original scheme and the two improved schemes under various internal ground fault cases are compared. The results show that when the HCSR-FCL of the original configuration scheme is in the current-sharing state and its switch-arm (SA) has an internal ground fault, the current-limiting arm (CA) will lose its shunting function, and the fast switch has to cut off the short current more than twice of the normal fault and bear the excessive voltage, threatening the safety of the FCL and the stability of the system. Both of the two improved schemes can solve this problem, and ensure the reliability and the effectiveness of the FCL, to provide a reference for the development and engineering application of the HCSR-FCL.
- 10 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (8) , 1-5
Design Improvement of Fault Current Limiter Based on High Coupled Split Reactor Considering the Impact of Internal Ground Fault
The fault current limiter (FCL) based on high coupled split reactor (HCSR), namely HCSR-FCL, is a new technology developed in recent years to realize short-circuit current suppression and interruption. This paper investigates the impact of the internal ground fault on the HCSR-FCL, based on the analysis of its basic principle and internal structure, and proposes two improved schemes for the wiring mode and the current-transformer (CT) configuration. Through the theoretical and simulation analysis, the performance of the original scheme and the two improved schemes under various internal ground fault cases are compared. The results show that when the HCSR-FCL of the original configuration scheme is in the current-sharing state and its switch-arm (SA) has an internal ground fault, the current-limiting arm (CA) will lose its shunting function, and the fast switch has to cut off the short current more than twice of the normal fault and bear the excessive voltage, threatening the safety of the FCL and the stability of the system. Both of the two improved schemes can solve this problem, and ensure the reliability and the effectiveness of the FCL, to provide a reference for the development and engineering application of the HCSR-FCL.
- Open Access
Study on the Compatibility of Gas Adsorbents Used in a New Insulating Gas Mixture C4F7N/CO2
An environment-friendly insulating gas, perfluoroisobutyronitrile (C4F7N), has been developed recent years. Due to its relatively high liquefaction temperature (around −4.7 °C), buffer gases, such as CO2 and N2, are usually mixed with C4F7N to increase the pressure of the filled insulating medium. During these processes, the insulating gases may be contaminated with micro-water, and the mixture of H2O with C4F7N could produce HF under breakdown voltage condition, which is harmful to the gas insulated electricity transfer equipment. Therefore, removal of H2O and HF in situ from the gas insulated electricity transfer equipment is significant to its operation security. The adsorbents with the ability to remove H2O but without obvious C4F7N/CO2 adsorption capacity are essential to be used in this system. In this work, a series of industrial adsorbents and desiccants were tested for their compatibility with C4F7N/CO2. Pulse adsorption tests were conducted to evaluate the adsorption performance of these adsorbents and desiccants on C4F7N and CO2. The 5A molecular sieve showed high adsorption of C4F7N (22.82 mL/g) and CO2 (43.86 mL/g); F-03 did not show adsorption capacity with C4F7N, however, it adsorbed CO2 (26.2 mL/g) clearly. Some other HF adsorbents, including NaF, CaF2, MgF2, Al(OH)3, and some desiccants including CaCl2, Na2SO4, MgSO4 were tested for their compatibility with C4F7N and CO2, and they showed negligible adsorption capacity on C4F7N and CO2. The results suggested that these adsorbents used in the gas insulated electricity transfer equipment filled with SF6 (mainly 5A and F-03 molecular sieves) are not suitable anymore. The results of this work suggest that it is a good strategy to use a mixture of desiccants and HF adsorbents as new adsorbents in the equipment filled with C4F7N/CO2.
Open AccessStudy on the Compatibility of Gas Adsorbents Used in a New Insulating Gas Mixture C4F7N/CO2
An environment-friendly insulating gas, perfluoroisobutyronitrile (C4F7N), has been developed recent years. Due to its relatively high liquefaction temperature (around −4.7 °C), buffer gases, such as CO2 and N2, are usually mixed with C4F7N to increase the pressure of the filled insulating medium. During these processes, the insulating gases may be contaminated with micro-water, and the mixture of H2O with C4F7N could produce HF under breakdown voltage condition, which is harmful to the gas insulated electricity transfer equipment. Therefore, removal of H2O and HF in situ from the gas insulated electricity transfer equipment is significant to its operation security. The adsorbents with the ability to remove H2O but without obvious C4F7N/CO2 adsorption capacity are essential to be used in this system. In this work, a series of industrial adsorbents and desiccants were tested for their compatibility with C4F7N/CO2. Pulse adsorption tests were conducted to evaluate the adsorption performance of these adsorbents and desiccants on C4F7N and CO2. The 5A molecular sieve showed high adsorption of C4F7N (22.82 mL/g) and CO2 (43.86 mL/g); F-03 did not show adsorption capacity with C4F7N, however, it adsorbed CO2 (26.2 mL/g) clearly. Some other HF adsorbents, including NaF, CaF2, MgF2, Al(OH)3, and some desiccants including CaCl2, Na2SO4, MgSO4 were tested for their compatibility with C4F7N and CO2, and they showed negligible adsorption capacity on C4F7N and CO2. The results suggested that these adsorbents used in the gas insulated electricity transfer equipment filled with SF6 (mainly 5A and F-03 molecular sieves) are not suitable anymore. The results of this work suggest that it is a good strategy to use a mixture of desiccants and HF adsorbents as new adsorbents in the equipment filled with C4F7N/CO2.
- Open Access
Alternative Environmentally Friendly Insulating Gases for SF6
Sulfur hexafluoride (SF6) shows excellent insulation performance as an insulating gas. It is suitable for various climate conditions due to its low boiling point (−64 °C). Therefore, it has been widely used in power grid equipment. However, its global warming potential (GWP) is 23,500 times higher than that of CO2. Thus, it is imperative to find an environmentally friendly insulating gas with excellent insulation performance, lower GWP, and which is harmless to equipment and workers to replace SF6. In this review, four possible alternatives, including perfluorocarbons, trifluoroiodomethane, perfluorinated ketones, and fluoronitrile are reviewed in terms of basic physicochemical properties, insulation properties, decomposition properties, and compatibility with metals. The influences of trace H2O or O2 on their insulation performances are also discussed. The insulation strengths of these insulating gases were comparable to or higher than that of SF6. The GWPs of these insulating gases were lower than that of SF6. Due to their relatively high boiling point, they should be used as a mixture with buffering gases with low boiling points. Based on these four characteristics, perfluorinated ketones (C5F10O and C6F12O) and fluoronitrile (C4F7N) could partially substitute SF6 in some electrical equipment. Finally, some future needs and perspectives of environmentally friendly insulating gases are addressed for further studies.
Open AccessAlternative Environmentally Friendly Insulating Gases for SF6
Sulfur hexafluoride (SF6) shows excellent insulation performance as an insulating gas. It is suitable for various climate conditions due to its low boiling point (−64 °C). Therefore, it has been widely used in power grid equipment. However, its global warming potential (GWP) is 23,500 times higher than that of CO2. Thus, it is imperative to find an environmentally friendly insulating gas with excellent insulation performance, lower GWP, and which is harmless to equipment and workers to replace SF6. In this review, four possible alternatives, including perfluorocarbons, trifluoroiodomethane, perfluorinated ketones, and fluoronitrile are reviewed in terms of basic physicochemical properties, insulation properties, decomposition properties, and compatibility with metals. The influences of trace H2O or O2 on their insulation performances are also discussed. The insulation strengths of these insulating gases were comparable to or higher than that of SF6. The GWPs of these insulating gases were lower than that of SF6. Due to their relatively high boiling point, they should be used as a mixture with buffering gases with low boiling points. Based on these four characteristics, perfluorinated ketones (C5F10O and C6F12O) and fluoronitrile (C4F7N) could partially substitute SF6 in some electrical equipment. Finally, some future needs and perspectives of environmentally friendly insulating gases are addressed for further studies.
- Open Access
Thermal and Electromagnetic Combined Optimization Design of Dry Type Air Core Reactor
In this paper, taking the minimum metal conductor usage of an air core reactor as optimization goal, the influence of air ducts width and encapsulation number on thermal efficiency and electromagnetic efficiency are analyzed. Combined with the equation constraint conditions for maximum temperature rise conservation, inductance conservation and structure function of reactor considering the change of air ducts width and encapsulation number, the thermal and electromagnetic combined optimization curves are formed, and design results are achieved based on the initial design parameters. Meanwhile, the temperature field simulation model of the reactor is established and the results verify the correctness of the optimization method. According to the design results, the proportionality factor of metal conductor usage is only 0.61 compared with the initial design parameters of the reactor, which shows that the proposed comprehensive optimization method can significantly reduce conductor usage, improving the metal conductor utilization ratio.
Open AccessThermal and Electromagnetic Combined Optimization Design of Dry Type Air Core Reactor
In this paper, taking the minimum metal conductor usage of an air core reactor as optimization goal, the influence of air ducts width and encapsulation number on thermal efficiency and electromagnetic efficiency are analyzed. Combined with the equation constraint conditions for maximum temperature rise conservation, inductance conservation and structure function of reactor considering the change of air ducts width and encapsulation number, the thermal and electromagnetic combined optimization curves are formed, and design results are achieved based on the initial design parameters. Meanwhile, the temperature field simulation model of the reactor is established and the results verify the correctness of the optimization method. According to the design results, the proportionality factor of metal conductor usage is only 0.61 compared with the initial design parameters of the reactor, which shows that the proposed comprehensive optimization method can significantly reduce conductor usage, improving the metal conductor utilization ratio.