Jing Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jing Liu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Lian Zeng
Electric Power Test and Research Institute, Guangzhou Power Supply Co. Ltd., Guangzhou 510410, China
2 shared publications - Yaru Zhang
Electric Power Test and Research Institute, Guangzhou Power Supply Co. Ltd., Guangzhou 510410, China
2 shared publications - Yong Wang
Electric Power Test and Research Institute, Guangzhou Power Supply Co. Ltd., Guangzhou 510410, China
2 shared publications - Danqing Huang
Electric Power Test and Research Institute, Guangzhou Power Supply Co. Ltd., Guangzhou 510410, China
1 shared publication Jing Liu Jing
Guangzhou Power Supply Co Ltd, Elect Power Test & Res Inst, Guangzhou 510410, Peoples R China
1 shared publicationLian Zeng Lian
Guangzhou Power Supply Co Ltd, Elect Power Test & Res Inst, Guangzhou 510410, Peoples R China
1 shared publication
Latest Publications
- 8 May 2020
- Vol. 38 (5) , 606-610
Determination of impurity components in the perfluoroisobutyrile based on home-made gas-circulating system
A method for the determination of impurity components in perfluoroisobutyrile (C4F7N) gas was established by setting up a sealed pipe gas composition test system comprising an automatic six. way valve and gas chromatography. tandem mass spectrometry ( GC-MS) apparatus. C4F7N commercial gases were purchased from an abroad company ( AC company) and a domestic Chinese company ( DC company). These gases were subjected to qualitative and quantitative analyses by our test system and separated on an Agilent GS-GASPRO column ( 30 m x0. 32 mm x5 mu m). The results showed that the C4F7N commercial gas contained N-2, O-2, C3HF7 and a trace amount of C3F6. In the C4F7N commercial gas from the AC company, the total amount of impurities was 0. 13%, and the C4F7N content was 99. 87%. In the C4F7N gas from DC Company, the total amount of impurities was 0. 83%, and the C4F7N content was 99. 17%. The C4F7N contents of the gases from both the companies were consistent with the claimed value (>= 99%). The determination of the impurities C4F7N can be beneficial for the subsequent study of its insulation performance and thermal stability.
- 8 May 2020
- Vol. 38 (5) , 606-610
Determination of impurity components in the perfluoroisobutyrile based on home-made gas-circulating system
A method for the determination of impurity components in perfluoroisobutyrile (C4F7N) gas was established by setting up a sealed pipe gas composition test system comprising an automatic six. way valve and gas chromatography. tandem mass spectrometry ( GC-MS) apparatus. C4F7N commercial gases were purchased from an abroad company ( AC company) and a domestic Chinese company ( DC company). These gases were subjected to qualitative and quantitative analyses by our test system and separated on an Agilent GS-GASPRO column ( 30 m x0. 32 mm x5 mu m). The results showed that the C4F7N commercial gas contained N-2, O-2, C3HF7 and a trace amount of C3F6. In the C4F7N commercial gas from the AC company, the total amount of impurities was 0. 13%, and the C4F7N content was 99. 87%. In the C4F7N gas from DC Company, the total amount of impurities was 0. 83%, and the C4F7N content was 99. 17%. The C4F7N contents of the gases from both the companies were consistent with the claimed value (>= 99%). The determination of the impurities C4F7N can be beneficial for the subsequent study of its insulation performance and thermal stability.
- Open Access
Study on the Compatibility of Gas Adsorbents Used in a New Insulating Gas Mixture C4F7N/CO2
An environment-friendly insulating gas, perfluoroisobutyronitrile (C4F7N), has been developed recent years. Due to its relatively high liquefaction temperature (around −4.7 °C), buffer gases, such as CO2 and N2, are usually mixed with C4F7N to increase the pressure of the filled insulating medium. During these processes, the insulating gases may be contaminated with micro-water, and the mixture of H2O with C4F7N could produce HF under breakdown voltage condition, which is harmful to the gas insulated electricity transfer equipment. Therefore, removal of H2O and HF in situ from the gas insulated electricity transfer equipment is significant to its operation security. The adsorbents with the ability to remove H2O but without obvious C4F7N/CO2 adsorption capacity are essential to be used in this system. In this work, a series of industrial adsorbents and desiccants were tested for their compatibility with C4F7N/CO2. Pulse adsorption tests were conducted to evaluate the adsorption performance of these adsorbents and desiccants on C4F7N and CO2. The 5A molecular sieve showed high adsorption of C4F7N (22.82 mL/g) and CO2 (43.86 mL/g); F-03 did not show adsorption capacity with C4F7N, however, it adsorbed CO2 (26.2 mL/g) clearly. Some other HF adsorbents, including NaF, CaF2, MgF2, Al(OH)3, and some desiccants including CaCl2, Na2SO4, MgSO4 were tested for their compatibility with C4F7N and CO2, and they showed negligible adsorption capacity on C4F7N and CO2. The results suggested that these adsorbents used in the gas insulated electricity transfer equipment filled with SF6 (mainly 5A and F-03 molecular sieves) are not suitable anymore. The results of this work suggest that it is a good strategy to use a mixture of desiccants and HF adsorbents as new adsorbents in the equipment filled with C4F7N/CO2.
Open AccessStudy on the Compatibility of Gas Adsorbents Used in a New Insulating Gas Mixture C4F7N/CO2
An environment-friendly insulating gas, perfluoroisobutyronitrile (C4F7N), has been developed recent years. Due to its relatively high liquefaction temperature (around −4.7 °C), buffer gases, such as CO2 and N2, are usually mixed with C4F7N to increase the pressure of the filled insulating medium. During these processes, the insulating gases may be contaminated with micro-water, and the mixture of H2O with C4F7N could produce HF under breakdown voltage condition, which is harmful to the gas insulated electricity transfer equipment. Therefore, removal of H2O and HF in situ from the gas insulated electricity transfer equipment is significant to its operation security. The adsorbents with the ability to remove H2O but without obvious C4F7N/CO2 adsorption capacity are essential to be used in this system. In this work, a series of industrial adsorbents and desiccants were tested for their compatibility with C4F7N/CO2. Pulse adsorption tests were conducted to evaluate the adsorption performance of these adsorbents and desiccants on C4F7N and CO2. The 5A molecular sieve showed high adsorption of C4F7N (22.82 mL/g) and CO2 (43.86 mL/g); F-03 did not show adsorption capacity with C4F7N, however, it adsorbed CO2 (26.2 mL/g) clearly. Some other HF adsorbents, including NaF, CaF2, MgF2, Al(OH)3, and some desiccants including CaCl2, Na2SO4, MgSO4 were tested for their compatibility with C4F7N and CO2, and they showed negligible adsorption capacity on C4F7N and CO2. The results suggested that these adsorbents used in the gas insulated electricity transfer equipment filled with SF6 (mainly 5A and F-03 molecular sieves) are not suitable anymore. The results of this work suggest that it is a good strategy to use a mixture of desiccants and HF adsorbents as new adsorbents in the equipment filled with C4F7N/CO2.
- Open Access
Alternative Environmentally Friendly Insulating Gases for SF6
Sulfur hexafluoride (SF6) shows excellent insulation performance as an insulating gas. It is suitable for various climate conditions due to its low boiling point (−64 °C). Therefore, it has been widely used in power grid equipment. However, its global warming potential (GWP) is 23,500 times higher than that of CO2. Thus, it is imperative to find an environmentally friendly insulating gas with excellent insulation performance, lower GWP, and which is harmless to equipment and workers to replace SF6. In this review, four possible alternatives, including perfluorocarbons, trifluoroiodomethane, perfluorinated ketones, and fluoronitrile are reviewed in terms of basic physicochemical properties, insulation properties, decomposition properties, and compatibility with metals. The influences of trace H2O or O2 on their insulation performances are also discussed. The insulation strengths of these insulating gases were comparable to or higher than that of SF6. The GWPs of these insulating gases were lower than that of SF6. Due to their relatively high boiling point, they should be used as a mixture with buffering gases with low boiling points. Based on these four characteristics, perfluorinated ketones (C5F10O and C6F12O) and fluoronitrile (C4F7N) could partially substitute SF6 in some electrical equipment. Finally, some future needs and perspectives of environmentally friendly insulating gases are addressed for further studies.
Open AccessAlternative Environmentally Friendly Insulating Gases for SF6
Sulfur hexafluoride (SF6) shows excellent insulation performance as an insulating gas. It is suitable for various climate conditions due to its low boiling point (−64 °C). Therefore, it has been widely used in power grid equipment. However, its global warming potential (GWP) is 23,500 times higher than that of CO2. Thus, it is imperative to find an environmentally friendly insulating gas with excellent insulation performance, lower GWP, and which is harmless to equipment and workers to replace SF6. In this review, four possible alternatives, including perfluorocarbons, trifluoroiodomethane, perfluorinated ketones, and fluoronitrile are reviewed in terms of basic physicochemical properties, insulation properties, decomposition properties, and compatibility with metals. The influences of trace H2O or O2 on their insulation performances are also discussed. The insulation strengths of these insulating gases were comparable to or higher than that of SF6. The GWPs of these insulating gases were lower than that of SF6. Due to their relatively high boiling point, they should be used as a mixture with buffering gases with low boiling points. Based on these four characteristics, perfluorinated ketones (C5F10O and C6F12O) and fluoronitrile (C4F7N) could partially substitute SF6 in some electrical equipment. Finally, some future needs and perspectives of environmentally friendly insulating gases are addressed for further studies.