TPThomas Puiseux

Thomas Puiseux

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thomas Puiseux has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Physics‐Informed Neural Networks for Stenotic Pressure‐Drop Estimation From 4D Flow MRI : Validation Against In Vitro Measurements

    by Alexis Caltran, Thomas Puiseux, Barbara Garmy‐Susini, Fatima Zohra Mokrane, Ramiro Moreno

    Estimating pressure drops non‐invasively from 4D Flow MRI velocity data remains challenging: analytical and direct inverse estimators are efficient but sensitive to resolution and noise, whereas Computational Fluid Dynamics (CFD) requires uncertain boundary conditions and substantial preprocessing. Physics‐Informed Neural Networks (PINNs) offer a complementary framework by enforcing the Navier–Stokes equations on measured velocity fields, but their robustness under MRI‐like data degradation requires validation. We performed an experimental stenosis benchmark to validate a PINN framework for pressure estimation from internal velocity measurements, without prescribed inlet or outlet boundary conditions. Using a 3D‐printed stenotic phantom under steady and pulsatile flow conditions, the approach was evaluated against: (1) high‐fidelity CFD, (2) synthetic 4D Flow MRI at 1‐ to 3‐mm resolution, and (3) pressure transducer measurements. Against noise‐free CFD, the PINN achieved high fidelity (pressure Normalized Root Mean Square Error (NRMSE) ). Synthetic MRI tests showed that accuracy was strongly governed by spatial resolution. At 1 mm, pressure‐drop errors remained for moderate flows but reached in high‐velocity cases. At 3 mm, degraded flow features led to underestimation in steady cases and reduced flow‐rate consistency in pulsatile conditions. At adequate resolution, PINN‐derived pressure drops agreed with transducer measurements. This study provides a controlled benchmark of PINN‐based pressure reconstruction from 4D Flow MRI‐like data, not a direct clinical validation. PINNs can recover pressure fields without prescribed boundary conditions, but exhibit resolution‐related limitations similar to lightweight pressure estimators such as PPE, STE, and vWERP. Thus, they should be viewed as complementary tools rather than replacements for established estimators. Clinical translation will require resolved imaging and dedicated developments, such as MRI‐aware losses or sub‐voxel modeling, to mitigate data degradation.

  • Open Access

    Impact of Partial Echo on 4D Flow MRI: The Insight From Synthetic MRI

    by Morgane Garreau, Thomas Puiseux, Ramiro Moreno, Solenn Toupin, Daniel Giese, Franck Nicoud, Simon Mendez

    Purpose: The aim of this study is to investigate the impact of the partial echo on 4D flow MRI sequences thanks to in silico coupled MRI‐CFD (computational fluid dynamics) simulations. Methods: Two sequences are studied: one with a full echo (FE) and another using partial echo (PE) with an echo symmetry fraction of 0.75. MRI‐CFD simulations are conducted on an in silico pulsatile flow phantom for a sinusoidal inflow and a physiological inflow typical of the ascending aorta. Results: For both inflow signals, PE‐based simulations exhibited better compliance with their matching CFD simulations compared to the FE ones. Conclusion: The reduction of flow misregistration artifacts achieved through the use of PE appears to be more beneficial than the drawback of incomplete k‐space filling. The MRI‐CFD framework presented in this study appears as a useful tool to investigate the design of MRI sequences and to stratify its different sources of errors.

  • Open Access

    Accelerated sequences of 4D flow MRI using GRAPPA and compressed sensing: A comparison against conventional MRI and computational fluid dynamics

    by Morgane Garreau, Thomas Puiseux, Solenn Toupin, Daniel Giese, Simon Mendez, Franck Nicoud, Ramiro Moreno

    Purpose: To evaluate hemodynamic markers obtained by accelerated GRAPPA (R = 2, 3, 4) and compressed sensing (R = 7.6) 4D flow MRI sequences under complex flow conditions.Methods: The accelerated 4D flow MRI scans were performed on a pulsatile flow phantom, along with a nonaccelerated fully sampled k‐space acquisition. Computational fluid dynamics simulations based on the experimentally measured flow fields were conducted for additional comparison. Voxel‐wise comparisons (Bland–Altman analysis, ‐norm metric), as well as nonderived quantities (velocity profiles, flow rates, and peak velocities), were used to compare the velocity fields obtained from the different modalities.Results: 4D flow acquisitions and computational fluid dynamics depicted similar hemodynamic patterns. Voxel‐wise comparisons between the MRI scans highlighted larger discrepancies at the voxels located near the phantom's boundary walls. A trend for all MR scans to overestimate velocity profiles and peak velocities as compared to computational fluid dynamics was noticed in regions associated with high velocity or acceleration. However, good agreement for the flow rates was observed, and eddy‐current correction appeared essential for consistency of the flow rates measurements with respect to the principle of mass conservation.Conclusion: GRAPPA (R = 2, 3) and highly accelerated compressed sensing showed good agreement with the fully sampled acquisition. Yet, all 4D flow MRI scans were hampered by artifacts inherent to the phase‐contrast acquisition procedure. Computational fluid dynamics simulations are an interesting tool to assess these differences but are sensitive to modeling parameters.


  • Open Access

    Numerical simulation of time-resolved 3D phase-contrast magnetic resonance imaging

    by Thomas Puiseux, Anou Sewonu, Ramiro Moreno, Simon Mendez, Franck Nicoud

    A numerical approach is presented to efficiently simulate time-resolved 3D phase-contrast Magnetic resonance Imaging (or 4D Flow MRI) acquisitions under realistic flow conditions. The Navier-Stokes and Bloch equations are simultaneously solved with an Eulerian-Lagrangian formalism. A semi-analytic solution for the Bloch equations as well as a periodic particle seeding strategy are developed to reduce the computational cost. The velocity reconstruction pipeline is first validated by considering a Poiseuille flow configuration. The 4D Flow MRI simulation procedure is then applied to the flow within an in vitro flow phantom typical of the cardiovascular system. The simulated MR velocity images compare favorably to both the flow computed by solving the Navier-Stokes equations and experimental 4D Flow MRI measurements. A practical application is finally presented in which the MRI simulation framework is used to identify the origins of the MRI measurement errors.


  • Reconciling PC‐MRI and CFD: An in‐vitro study

    by Thomas Puiseux, Anou Sewonu, Olivier Meyrignac, Hervé Rousseau, Franck Nicoud, Simon Mendez, Ramiro Moreno

    Several well‐resolved 4D Flow MRI acquisitions of an idealized rigid flow phantom featuring an aneurysm, a curved channel as well as a bifurcation were performed under pulsatile regime. The resulting hemodynamics were processed to remove MRI artifacts. Subsequently, they were compared with CFD predictions computed on the same flow domain, using an in‐house high‐order low dissipative flow solver. Results show that reaching a good agreement is not straightforward but requires proper treatments of both techniques. Several sources of discrepancies are highlighted and their impact on the final correlation evaluated. While a very poor correlation (r2 = 0.63) is found in the entire domain between raw MRI and CFD data, correlation as high as r2 = 0.97 is found when artifacts are removed by post‐processing the MR data and down sampling the CFD results to match the MRI spatial and temporal resolutions. This work demonstrates that, in a well‐controlled environment, both PC‐MRI and CFD might bring reliable and correlated flow quantities when a proper methodology to reduce the errors is followed.