Bhupender Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bhupender Sharma has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Jayaram Nakka
3 shared publicationsRatna Dahiya
2 shared publications- Deshpande Gururaj Abhilash Krishna
Department of Electrical and Electronics Engineering, National Institute of Technology Karnataka, Surathkal
1 shared publication - Jayaram Nakka
Department of Electrical Engineering, National Institute of Technology Andhra Pradesh, Tadepalligudem 534102, India
1 shared publication - Lalit Mohan Saini
National Institute of Technology Kurukshetra Kurukshetra India
1 shared publication - Pandry Narendra Rao
Department of Electrical and Electronics Engineering, RV College of Engineering, Bengaluru, India
1 shared publication
Latest Publications
- Open Access
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 56791-56809
A Hybrid PV-Wind Single-Phase Transformer-Less Grid-Connected Cascaded NPC Inverter Minimizing Leakage Currents
Transformer-less grid-connected hybrid PV-wind energy systems offer higher efficiency but suffer from leakage current caused by parasitic capacitance and degradation in power quality. Therefore, an important research challenge is to design a multilevel inverter topology capable of minimizing leakage current while maintaining high power quality and efficient grid integration. To address the issue, two three-level converters, NPC1 and NPC2, are cascaded to achieve five-level transformer less inverter architecture. The effect of leakage current generated by the parasitic capacitance is studied with different PV and wind energy combinations with NPC1 and NPC2. A generalized inverter combination with LC-filters is presented to suppress the leakage current at the high switching frequency and fundamental frequency, satisfying the German standards DIN VDE 0126-1-1. The proposed inverter with LC-filters attenuates the pulse width modulation natured high-frequency voltage and improve the power quality and efficiency by enhancing the THD profile following the IEC 61707 and IEEE 1547-200 standards. The adopted control scheme maintains a constant dc-link voltage across the switches and enables the inverter to apply for high voltage applications. The proposed inverter dynamic and steady-state performance is compared with the different five-level combinations of PV and wind energy with NPC1 and NPC2. The results are experimentally validated in a hardware-in-the-loop FPGA based real-time digital simulator using OPAL-RT OP5700 as plant and dSPACE 1104 as controller.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 56791-56809
Open AccessA Hybrid PV-Wind Single-Phase Transformer-Less Grid-Connected Cascaded NPC Inverter Minimizing Leakage Currents
Transformer-less grid-connected hybrid PV-wind energy systems offer higher efficiency but suffer from leakage current caused by parasitic capacitance and degradation in power quality. Therefore, an important research challenge is to design a multilevel inverter topology capable of minimizing leakage current while maintaining high power quality and efficient grid integration. To address the issue, two three-level converters, NPC1 and NPC2, are cascaded to achieve five-level transformer less inverter architecture. The effect of leakage current generated by the parasitic capacitance is studied with different PV and wind energy combinations with NPC1 and NPC2. A generalized inverter combination with LC-filters is presented to suppress the leakage current at the high switching frequency and fundamental frequency, satisfying the German standards DIN VDE 0126-1-1. The proposed inverter with LC-filters attenuates the pulse width modulation natured high-frequency voltage and improve the power quality and efficiency by enhancing the THD profile following the IEC 61707 and IEEE 1547-200 standards. The adopted control scheme maintains a constant dc-link voltage across the switches and enables the inverter to apply for high voltage applications. The proposed inverter dynamic and steady-state performance is compared with the different five-level combinations of PV and wind energy with NPC1 and NPC2. The results are experimentally validated in a hardware-in-the-loop FPGA based real-time digital simulator using OPAL-RT OP5700 as plant and dSPACE 1104 as controller.
- 1 January 2024
- Published by Springer Nature
- p. 13-25
Three-Phase Three-Leg Four-Wire High Power Factor Converter Addressing the Problem of Unbalanced DC Link Capacitor Voltages
- 1 January 2024
- Published by Springer Nature
- p. 13-25
Three-Phase Three-Leg Four-Wire High Power Factor Converter Addressing the Problem of Unbalanced DC Link Capacitor Voltages
- 1 June 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 171, 1-14
Effective grid connected power injection scheme using multilevel inverter based hybrid wind solar energy conversion system
- 1 June 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 171, 1-14
Effective grid connected power injection scheme using multilevel inverter based hybrid wind solar energy conversion system
- 8 May 2019
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 47 (8) , 1323-1339
Capacitor voltage balancing in cascaded H‐bridge multilevel inverter and its modelling analysis for grid integrated wind energy conversion system application
Summary: In this study, a comprehensive control scheme for cascaded H‐bridge multilevel inverter (CHBMLI)‐based grid integrated bulk wind energy conversion system (WECS) addressing the problem of deviation of wind speeds among windmills like a partial shading condition of PV system is presented. The proposed control scheme uses independent dc links with reduced voltages that makes such a topology an ideal candidate for high and medium power WECS with improved reliability. Inconsistency of wind speeds at each turbine causes distinct voltage conditions among the isolated dc links of the CHBMLI H‐bridge cells (HBC) leading to unstable power generation. The projected scheme along with maximum and efficient energy conversion has the ability of dc link capacitor voltage balancing in each HBC of CHBMLI during the above said power generation mismatch conditions and also maintains power quality in the grid side voltage and injected currents as per standards. Moreover, the modelling analysis of the adopted CHBMLI for the grid integrated WECS application has also been derived. The system performance under inconsistent wind speed environment has been tested and analysed by using MATLAB simulation and validated by using FPGA‐based real‐time simulator (Opal‐RT‐OP5700).
- 8 May 2019
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 47 (8) , 1323-1339
Capacitor voltage balancing in cascaded H‐bridge multilevel inverter and its modelling analysis for grid integrated wind energy conversion system application
Summary: In this study, a comprehensive control scheme for cascaded H‐bridge multilevel inverter (CHBMLI)‐based grid integrated bulk wind energy conversion system (WECS) addressing the problem of deviation of wind speeds among windmills like a partial shading condition of PV system is presented. The proposed control scheme uses independent dc links with reduced voltages that makes such a topology an ideal candidate for high and medium power WECS with improved reliability. Inconsistency of wind speeds at each turbine causes distinct voltage conditions among the isolated dc links of the CHBMLI H‐bridge cells (HBC) leading to unstable power generation. The projected scheme along with maximum and efficient energy conversion has the ability of dc link capacitor voltage balancing in each HBC of CHBMLI during the above said power generation mismatch conditions and also maintains power quality in the grid side voltage and injected currents as per standards. Moreover, the modelling analysis of the adopted CHBMLI for the grid integrated WECS application has also been derived. The system performance under inconsistent wind speed environment has been tested and analysed by using MATLAB simulation and validated by using FPGA‐based real‐time simulator (Opal‐RT‐OP5700).
- Open Access
- 8 January 2019
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 12 (2) , 284-294
Single‐phase cascaded multilevel inverter topology addressed with the problem of unequal photovoltaic power distribution in isolated dc links
This study presents a control scheme for a grid‐connected cascaded H‐bridge multilevel inverter (CHBMLI) based solar energy conversion system (SECS) addressing the problem of distinct temperature and irradiations which raise to partial shading and panel mismatch conditions in large‐scale photovoltaic (PV) generation. Along with feasibility in high‐voltage system, the major advantage of isolated dc links in CHBMLI suffers the distinct dc‐link voltage conditions when employed as a pulse‐width modulated (PWM) converter governing either unequal dc loads or dc sources due to variable power consumption or generation, respectively. The proposed control scheme has the ability of balancing the dc‐link capacitors in each H‐bridge cell of CHBMLI adopted for this system and during the above‐said power generation mismatch conditions in SECS. The proposed system along with maximum and efficient energy conversion, the power quality in the grid‐side voltage and injected currents is also monitored and maintained as per standards. In addition, the modelling analysis of the converter has also been derived to define the mathematical model of CHBMLI as PWM converter adopted for this application. The performance of system has been analysed using MATLAB simulation and validated experimentally on prototype model by using dSPACE‐1104.
- 8 January 2019
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 12 (2) , 284-294
Open AccessSingle‐phase cascaded multilevel inverter topology addressed with the problem of unequal photovoltaic power distribution in isolated dc links
This study presents a control scheme for a grid‐connected cascaded H‐bridge multilevel inverter (CHBMLI) based solar energy conversion system (SECS) addressing the problem of distinct temperature and irradiations which raise to partial shading and panel mismatch conditions in large‐scale photovoltaic (PV) generation. Along with feasibility in high‐voltage system, the major advantage of isolated dc links in CHBMLI suffers the distinct dc‐link voltage conditions when employed as a pulse‐width modulated (PWM) converter governing either unequal dc loads or dc sources due to variable power consumption or generation, respectively. The proposed control scheme has the ability of balancing the dc‐link capacitors in each H‐bridge cell of CHBMLI adopted for this system and during the above‐said power generation mismatch conditions in SECS. The proposed system along with maximum and efficient energy conversion, the power quality in the grid‐side voltage and injected currents is also monitored and maintained as per standards. In addition, the modelling analysis of the converter has also been derived to define the mathematical model of CHBMLI as PWM converter adopted for this application. The performance of system has been analysed using MATLAB simulation and validated experimentally on prototype model by using dSPACE‐1104.