Shaoya Guan
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shaoya Guan has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Cai Meng
School of Astronautics, Beihang University, Beijing, China
4 shared publications - Qi Wang
Beihang University
3 shared publications Kai Sun
School of Astronautics, Beihang University, Beijing 100191, China
2 shared publicationsBo Liu
School of Astronautics, Beihang University, Beijing 100191, China and Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100191, China
1 shared publication- Kai Sun
Beihang University, School of Astronautics, Beijing, China
1 shared publication - Tianmiao Wang
School of Mechanical Engineering and Automation, Beihang University, Beijing 100191, China
1 shared publication
Latest Publications
- 21 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (9) , 3300-3309
Transfer Learning for Nonrigid 2D/3D Cardiovascular Images Registration
Cardiovascular image registration is an essential approach to combine the advantages of preoperative 3D computed tomography angiograph (CTA) images and intraoperative 2D X-ray/ digital subtraction angiography (DSA) images together in minimally invasive vascular interventional surgery (MIVI). Recent studies have shown that convolutional neural network (CNN) regression model can be used to register these two modality vascular images with fast speed and satisfactory accuracy. However, CNN regression model trained by tens of thousands of images of one patient is often unable to be applied to another patient due to the large difference and deformation of vascular structure in different patients. To overcome this challenge, we evaluate the ability of transfer learning (TL) for the registration of 2D/3D deformable cardiovascular images. Frozen weights in the convolutional layers were optimized to find the best common feature extractors for TL. After TL, the training data set size was reduced to 200 for a randomly selected patient to get accurate registration results. We compared the effectiveness of our proposed nonrigid registration model after TL with not only that without TL but also some traditional intensity-based methods to evaluate that our nonrigid model after TL performs better on deformable cardiovascular image registration.
- 21 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (9) , 3300-3309
Transfer Learning for Nonrigid 2D/3D Cardiovascular Images Registration
Cardiovascular image registration is an essential approach to combine the advantages of preoperative 3D computed tomography angiograph (CTA) images and intraoperative 2D X-ray/ digital subtraction angiography (DSA) images together in minimally invasive vascular interventional surgery (MIVI). Recent studies have shown that convolutional neural network (CNN) regression model can be used to register these two modality vascular images with fast speed and satisfactory accuracy. However, CNN regression model trained by tens of thousands of images of one patient is often unable to be applied to another patient due to the large difference and deformation of vascular structure in different patients. To overcome this challenge, we evaluate the ability of transfer learning (TL) for the registration of 2D/3D deformable cardiovascular images. Frozen weights in the convolutional layers were optimized to find the best common feature extractors for TL. After TL, the training data set size was reduced to 200 for a randomly selected patient to get accurate registration results. We compared the effectiveness of our proposed nonrigid registration model after TL with not only that without TL but also some traditional intensity-based methods to evaluate that our nonrigid model after TL performs better on deformable cardiovascular image registration.
- Open Access
- 15 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 162629-162638
2D-3D Registration With Weighted Local Mutual Information in Vascular Interventions
Registration between intra-operative 2D digital subtraction angiography (DSA) and pre-operative 3D computed tomography angiography (CTA) is useful in guidance of vascular interventional surgery (VIS). Due to the flow and diffusion of contrast in vessels, not all of the vessels are visible in the DSA, which leads to difficulty in registration. Although conventional mutual information (MI) and normalized MI (NMI) performs well in orthopedic surgery, it cannot solute this problem in VIS well. In this paper, a novel similarity measure, WLMI (Weighted Local Mutual Information), is proposed to perform 2D-3D registration, which uses the patches selected in DSA to find the best match in the DRRs (Digital Radiography Reconstruction) with weighted MI. At first we choose several ways to measure the abundance of block information in order to select small and scattered patches in the DSA image. Then different weights are given to these patches according to their information abundance in the calculation of local MI. With the proposed WLMI, the 2D-3D registration experiments are conducted with synthetic and real DSA images to CTA vessel model. In the registration of synthetic DSA to CTA model, the optimal way to measure information abundance and the optimal weight parameter are selected. The registration with intact and partially absent vessels are compared with conventional methods using MAE, mTREproj, and IoU metrics. In the registration of real DSA to CTA model, only IoU is used to compare the difference since the ground-truth cannot be obtained. Both the synthetic and real DSA registration results show that the proposed WLMI can cope with the problem that partial vessel is invisible in the DSA, and better registration results can be achieved compared with the conventional metrics such as MI, NMI etc. Therefore, WLMI is more suitable to be used to perform 2D/3D registration in VIS.
- 15 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 162629-162638
Open Access2D-3D Registration With Weighted Local Mutual Information in Vascular Interventions
Registration between intra-operative 2D digital subtraction angiography (DSA) and pre-operative 3D computed tomography angiography (CTA) is useful in guidance of vascular interventional surgery (VIS). Due to the flow and diffusion of contrast in vessels, not all of the vessels are visible in the DSA, which leads to difficulty in registration. Although conventional mutual information (MI) and normalized MI (NMI) performs well in orthopedic surgery, it cannot solute this problem in VIS well. In this paper, a novel similarity measure, WLMI (Weighted Local Mutual Information), is proposed to perform 2D-3D registration, which uses the patches selected in DSA to find the best match in the DRRs (Digital Radiography Reconstruction) with weighted MI. At first we choose several ways to measure the abundance of block information in order to select small and scattered patches in the DSA image. Then different weights are given to these patches according to their information abundance in the calculation of local MI. With the proposed WLMI, the 2D-3D registration experiments are conducted with synthetic and real DSA images to CTA vessel model. In the registration of synthetic DSA to CTA model, the optimal way to measure information abundance and the optimal weight parameter are selected. The registration with intact and partially absent vessels are compared with conventional methods using MAE, mTREproj, and IoU metrics. In the registration of real DSA to CTA model, only IoU is used to compare the difference since the ground-truth cannot be obtained. Both the synthetic and real DSA registration results show that the proposed WLMI can cope with the problem that partial vessel is invisible in the DSA, and better registration results can be achieved compared with the conventional metrics such as MI, NMI etc. Therefore, WLMI is more suitable to be used to perform 2D/3D registration in VIS.
- Open Access
- 4 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 17524-17534
Deformable Cardiovascular Image Registration via Multi-Channel Convolutional Neural Network
Vascular image registration is an essential approach to combine the advantages of preoperative 3D computed tomography angiography (CTA) images and intraoperative 2D X-ray/ digital subtraction angiography (DSA) images together. Cardiovascular deformation caused by heartbeat and respiration is one of the most vital factors that affect vascular image registration accuracy. Traditional optimized-based registration methods suffer severely from the high computational complexity which hinders the clinical applications of these methods seriously. To overcome these challenges, we developed a novel multi-channel convolutional neural network (MCNN) that combines a convolutional neural network (CNN) with a periodic vascular diameter variation model. Our method is capable of registering simulated DSA images or real DSA images with their corresponding 3D models in a matter of milliseconds. Our presented MCNN model achieves excellent registration results of three different kinds of cardiovascular patients. The mean absolute error (MAE) of all six transformation parameters of the MCNN model presented in this paper is less than 1 mm or 1 degree. The improvement to our MCNN model in registration accuracy is larger than 75% over single-channel CNN model. Our MCNN method performs more effectively and stably than the state-of-the-art intensity-based methods especially when vascular deformations occur.
- 4 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 17524-17534
Open AccessDeformable Cardiovascular Image Registration via Multi-Channel Convolutional Neural Network
Vascular image registration is an essential approach to combine the advantages of preoperative 3D computed tomography angiography (CTA) images and intraoperative 2D X-ray/ digital subtraction angiography (DSA) images together. Cardiovascular deformation caused by heartbeat and respiration is one of the most vital factors that affect vascular image registration accuracy. Traditional optimized-based registration methods suffer severely from the high computational complexity which hinders the clinical applications of these methods seriously. To overcome these challenges, we developed a novel multi-channel convolutional neural network (MCNN) that combines a convolutional neural network (CNN) with a periodic vascular diameter variation model. Our method is capable of registering simulated DSA images or real DSA images with their corresponding 3D models in a matter of milliseconds. Our presented MCNN model achieves excellent registration results of three different kinds of cardiovascular patients. The mean absolute error (MAE) of all six transformation parameters of the MCNN model presented in this paper is less than 1 mm or 1 degree. The improvement to our MCNN model in registration accuracy is larger than 75% over single-channel CNN model. Our MCNN method performs more effectively and stably than the state-of-the-art intensity-based methods especially when vascular deformations occur.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Single shot 2D3D image regisraton
In this paper, we present a very deep, 11 weights layers, Convolutional Neural Network (CNN) regression model for single shot and real-time 2D/3D registration. Different from optimization-based methods, which iteratively optimize the transformation parameters over a scalar-valued metric function representing the quality of the registration, the proposed method exploits the information embedded in the appearances of the Digitally Reconstructed Radiograph(DRR) and X-ray images and employs CNN regressors to directly estimate the transformation parameters. Unlike previous CNN approach which adopts an indirect way to cast the original complicated problem as several parts, we train a much deeper network to handle this registration problem by continuing to endeep the Convolutional Neural Network. To fit zooming in and out of DRRs more effectively we further more design a multi scale convolution kernel network. Our experiment results demonstrate the advantage of the proposed method in computational efficiency and accuracy. The research may indicate that powerful Convolutional Neural Network can learn the highly complex regression function that mapping the raw image data to the registration parameters thus achieve high accuracy and real-time in 2D/3D registration in a direct way.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Single shot 2D3D image regisraton
In this paper, we present a very deep, 11 weights layers, Convolutional Neural Network (CNN) regression model for single shot and real-time 2D/3D registration. Different from optimization-based methods, which iteratively optimize the transformation parameters over a scalar-valued metric function representing the quality of the registration, the proposed method exploits the information embedded in the appearances of the Digitally Reconstructed Radiograph(DRR) and X-ray images and employs CNN regressors to directly estimate the transformation parameters. Unlike previous CNN approach which adopts an indirect way to cast the original complicated problem as several parts, we train a much deeper network to handle this registration problem by continuing to endeep the Convolutional Neural Network. To fit zooming in and out of DRRs more effectively we further more design a multi scale convolution kernel network. Our experiment results demonstrate the advantage of the proposed method in computational efficiency and accuracy. The research may indicate that powerful Convolutional Neural Network can learn the highly complex regression function that mapping the raw image data to the registration parameters thus achieve high accuracy and real-time in 2D/3D registration in a direct way.