Qi Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qi Wang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Cai Meng
School of Astronautics, Beihang University, Beijing, China
3 shared publications - Shaoya Guan
School of Mechanical Engineering and Automation, Beijing, China, 100191
3 shared publications - Fangfang Zhuang
Beijing University of Aeronautics and Astronautics
2 shared publications Kai Sun
School of Astronautics, Beihang University, Beijing 100191, China
2 shared publicationsQingyun Wang
Beihang University
2 shared publicationsRunsen Zhang
Beihang University
2 shared publications
Latest Publications
- 18 November 2019
- Published by Springer Nature in Multibody System Dynamics
- Vol. 48 (2) , 211-238
An improved implicit method for mechanical systems with set-valued friction
- 18 November 2019
- Published by Springer Nature in Multibody System Dynamics
- Vol. 48 (2) , 211-238
An improved implicit method for mechanical systems with set-valued friction
- Open Access
- 15 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 162629-162638
2D-3D Registration With Weighted Local Mutual Information in Vascular Interventions
Registration between intra-operative 2D digital subtraction angiography (DSA) and pre-operative 3D computed tomography angiography (CTA) is useful in guidance of vascular interventional surgery (VIS). Due to the flow and diffusion of contrast in vessels, not all of the vessels are visible in the DSA, which leads to difficulty in registration. Although conventional mutual information (MI) and normalized MI (NMI) performs well in orthopedic surgery, it cannot solute this problem in VIS well. In this paper, a novel similarity measure, WLMI (Weighted Local Mutual Information), is proposed to perform 2D-3D registration, which uses the patches selected in DSA to find the best match in the DRRs (Digital Radiography Reconstruction) with weighted MI. At first we choose several ways to measure the abundance of block information in order to select small and scattered patches in the DSA image. Then different weights are given to these patches according to their information abundance in the calculation of local MI. With the proposed WLMI, the 2D-3D registration experiments are conducted with synthetic and real DSA images to CTA vessel model. In the registration of synthetic DSA to CTA model, the optimal way to measure information abundance and the optimal weight parameter are selected. The registration with intact and partially absent vessels are compared with conventional methods using MAE, mTREproj, and IoU metrics. In the registration of real DSA to CTA model, only IoU is used to compare the difference since the ground-truth cannot be obtained. Both the synthetic and real DSA registration results show that the proposed WLMI can cope with the problem that partial vessel is invisible in the DSA, and better registration results can be achieved compared with the conventional metrics such as MI, NMI etc. Therefore, WLMI is more suitable to be used to perform 2D/3D registration in VIS.
- 15 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 162629-162638
Open Access2D-3D Registration With Weighted Local Mutual Information in Vascular Interventions
Registration between intra-operative 2D digital subtraction angiography (DSA) and pre-operative 3D computed tomography angiography (CTA) is useful in guidance of vascular interventional surgery (VIS). Due to the flow and diffusion of contrast in vessels, not all of the vessels are visible in the DSA, which leads to difficulty in registration. Although conventional mutual information (MI) and normalized MI (NMI) performs well in orthopedic surgery, it cannot solute this problem in VIS well. In this paper, a novel similarity measure, WLMI (Weighted Local Mutual Information), is proposed to perform 2D-3D registration, which uses the patches selected in DSA to find the best match in the DRRs (Digital Radiography Reconstruction) with weighted MI. At first we choose several ways to measure the abundance of block information in order to select small and scattered patches in the DSA image. Then different weights are given to these patches according to their information abundance in the calculation of local MI. With the proposed WLMI, the 2D-3D registration experiments are conducted with synthetic and real DSA images to CTA vessel model. In the registration of synthetic DSA to CTA model, the optimal way to measure information abundance and the optimal weight parameter are selected. The registration with intact and partially absent vessels are compared with conventional methods using MAE, mTREproj, and IoU metrics. In the registration of real DSA to CTA model, only IoU is used to compare the difference since the ground-truth cannot be obtained. Both the synthetic and real DSA registration results show that the proposed WLMI can cope with the problem that partial vessel is invisible in the DSA, and better registration results can be achieved compared with the conventional metrics such as MI, NMI etc. Therefore, WLMI is more suitable to be used to perform 2D/3D registration in VIS.
- Open Access
- 4 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 17524-17534
Deformable Cardiovascular Image Registration via Multi-Channel Convolutional Neural Network
Vascular image registration is an essential approach to combine the advantages of preoperative 3D computed tomography angiography (CTA) images and intraoperative 2D X-ray/ digital subtraction angiography (DSA) images together. Cardiovascular deformation caused by heartbeat and respiration is one of the most vital factors that affect vascular image registration accuracy. Traditional optimized-based registration methods suffer severely from the high computational complexity which hinders the clinical applications of these methods seriously. To overcome these challenges, we developed a novel multi-channel convolutional neural network (MCNN) that combines a convolutional neural network (CNN) with a periodic vascular diameter variation model. Our method is capable of registering simulated DSA images or real DSA images with their corresponding 3D models in a matter of milliseconds. Our presented MCNN model achieves excellent registration results of three different kinds of cardiovascular patients. The mean absolute error (MAE) of all six transformation parameters of the MCNN model presented in this paper is less than 1 mm or 1 degree. The improvement to our MCNN model in registration accuracy is larger than 75% over single-channel CNN model. Our MCNN method performs more effectively and stably than the state-of-the-art intensity-based methods especially when vascular deformations occur.
- 4 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 17524-17534
Open AccessDeformable Cardiovascular Image Registration via Multi-Channel Convolutional Neural Network
Vascular image registration is an essential approach to combine the advantages of preoperative 3D computed tomography angiography (CTA) images and intraoperative 2D X-ray/ digital subtraction angiography (DSA) images together. Cardiovascular deformation caused by heartbeat and respiration is one of the most vital factors that affect vascular image registration accuracy. Traditional optimized-based registration methods suffer severely from the high computational complexity which hinders the clinical applications of these methods seriously. To overcome these challenges, we developed a novel multi-channel convolutional neural network (MCNN) that combines a convolutional neural network (CNN) with a periodic vascular diameter variation model. Our method is capable of registering simulated DSA images or real DSA images with their corresponding 3D models in a matter of milliseconds. Our presented MCNN model achieves excellent registration results of three different kinds of cardiovascular patients. The mean absolute error (MAE) of all six transformation parameters of the MCNN model presented in this paper is less than 1 mm or 1 degree. The improvement to our MCNN model in registration accuracy is larger than 75% over single-channel CNN model. Our MCNN method performs more effectively and stably than the state-of-the-art intensity-based methods especially when vascular deformations occur.
- 18 July 2018
- Published by Springer Nature in Applied Mathematics and Mechanics
- Vol. 39 (9) , 1239-1258
Comparison and analysis of two Coulomb friction models on the dynamic behavior of slider-crank mechanism with a revolute clearance joint
- 18 July 2018
- Published by Springer Nature in Applied Mathematics and Mechanics
- Vol. 39 (9) , 1239-1258
Comparison and analysis of two Coulomb friction models on the dynamic behavior of slider-crank mechanism with a revolute clearance joint
- 2 February 2018
- Published by Springer Nature in Acta Mechanica Sinica
- Vol. 34 (3) , 578-588
LCP method for a planar passive dynamic walker based on an event-driven scheme
- 2 February 2018
- Published by Springer Nature in Acta Mechanica Sinica
- Vol. 34 (3) , 578-588
LCP method for a planar passive dynamic walker based on an event-driven scheme
- Open Access
- 12 December 2017
- Published by Springer Nature in Multibody System Dynamics
- Vol. 43 (2) , 153-174
Modeling and simulation of longitudinal dynamics coupled with clutch engagement dynamics for ground vehicles
- 12 December 2017
- Published by Springer Nature in Multibody System Dynamics
- Vol. 43 (2) , 153-174
Open AccessModeling and simulation of longitudinal dynamics coupled with clutch engagement dynamics for ground vehicles
- 28 October 2017
- Published by Springer Nature in Applied Mathematics and Mechanics
- Vol. 38 (12) , 1733-1752
Numerical method for dynamics of multi-body systems with two-dimensional Coulomb dry friction and nonholonomic constraints
- 28 October 2017
- Published by Springer Nature in Applied Mathematics and Mechanics
- Vol. 38 (12) , 1733-1752
Numerical method for dynamics of multi-body systems with two-dimensional Coulomb dry friction and nonholonomic constraints
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Single shot 2D3D image regisraton
In this paper, we present a very deep, 11 weights layers, Convolutional Neural Network (CNN) regression model for single shot and real-time 2D/3D registration. Different from optimization-based methods, which iteratively optimize the transformation parameters over a scalar-valued metric function representing the quality of the registration, the proposed method exploits the information embedded in the appearances of the Digitally Reconstructed Radiograph(DRR) and X-ray images and employs CNN regressors to directly estimate the transformation parameters. Unlike previous CNN approach which adopts an indirect way to cast the original complicated problem as several parts, we train a much deeper network to handle this registration problem by continuing to endeep the Convolutional Neural Network. To fit zooming in and out of DRRs more effectively we further more design a multi scale convolution kernel network. Our experiment results demonstrate the advantage of the proposed method in computational efficiency and accuracy. The research may indicate that powerful Convolutional Neural Network can learn the highly complex regression function that mapping the raw image data to the registration parameters thus achieve high accuracy and real-time in 2D/3D registration in a direct way.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Single shot 2D3D image regisraton
In this paper, we present a very deep, 11 weights layers, Convolutional Neural Network (CNN) regression model for single shot and real-time 2D/3D registration. Different from optimization-based methods, which iteratively optimize the transformation parameters over a scalar-valued metric function representing the quality of the registration, the proposed method exploits the information embedded in the appearances of the Digitally Reconstructed Radiograph(DRR) and X-ray images and employs CNN regressors to directly estimate the transformation parameters. Unlike previous CNN approach which adopts an indirect way to cast the original complicated problem as several parts, we train a much deeper network to handle this registration problem by continuing to endeep the Convolutional Neural Network. To fit zooming in and out of DRRs more effectively we further more design a multi scale convolution kernel network. Our experiment results demonstrate the advantage of the proposed method in computational efficiency and accuracy. The research may indicate that powerful Convolutional Neural Network can learn the highly complex regression function that mapping the raw image data to the registration parameters thus achieve high accuracy and real-time in 2D/3D registration in a direct way.
- 9 May 2014
- Published by Springer Nature in Acta Mechanica Sinica
- Vol. 30 (3) , 437-446
Modeling and analysis of rigid multibody systems with driving constraints and frictional translation joints
- 9 May 2014
- Published by Springer Nature in Acta Mechanica Sinica
- Vol. 30 (3) , 437-446
Modeling and analysis of rigid multibody systems with driving constraints and frictional translation joints
- Open Access
A Finite Element Method for Solving 2D Contact Problems with Coulomb Friction and Bilateral Constraints
Based on the plenty method, this paper describes a numerical method for 2D non-smooth contact problems with Coulomb friction and bilateral constraints and its application to the simulation of statics and dynamics for a frictional translational joint. Comparison is made with results obtained using a finite element program, ANSYS.
Open AccessA Finite Element Method for Solving 2D Contact Problems with Coulomb Friction and Bilateral Constraints
Based on the plenty method, this paper describes a numerical method for 2D non-smooth contact problems with Coulomb friction and bilateral constraints and its application to the simulation of statics and dynamics for a frictional translational joint. Comparison is made with results obtained using a finite element program, ANSYS.