Eric Goudie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eric Goudie has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Dustin Carlson
Division of Gastroenterology and Hepatology, Feinberg School of Medicine Northwestern University Chicago Illinois USA
3 shared publications John E. Pandolfino
Kenneth C. Griffin Esophageal Center of Northwestern Medicine, Department of Medicine, Division of Gastroenterology and Hepatology, Feinberg School of Medicine Northwestern University Chicago Illinois USA
3 shared publications- Moishe Liberman
Thoracic Surgery Department, Centre Hopitalier de l’Université de Montreal, Pavillon R, 900 Rue Saint Denis, Montreal, QC H2X 0A9, Canada
2 shared publications - Neelesh A. Patankar
Department of Mechanical Engineering, McCormick School of Engineering Northwestern University Evanston Illinois USA
2 shared publications - Wenjun Kou
Kenneth C. Griffin Esophageal Center of Northwestern Medicine, Department of Medicine, Division of Gastroenterology and Hepatology, Feinberg School of Medicine Northwestern University Chicago Illinois USA
2 shared publications Adeline Jouquan
CETOC—CHUM Endoscopic Tracheobronchial and Oesophageal Center, Division of Thoracic Surgery, Department of Surgery, University of Montréal, Montréal, QC, Canada
1 shared publication
Latest Publications
- Open Access
- 7 October 2026
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 38 (10)
Biomechanical Assessment During High‐Resolution Impedance Manometry Enhances Characterization of Inconclusive Esophagogastric Junction Outflow Obstruction
Background: Esophagogastric junction outflow obstruction (EGJOO) identified on high‐resolution manometry (HRM) remains a clinically heterogeneous and inconclusive finding. Additional complementary testing with functional lumen imaging probe (FLIP) or timed barium esophagram (TBE) is recommended to confirm clinically relevant obstruction. We aimed to assess the association of novel Four‐Dimensional (4D) HRM metrics against FLIP and TBE outcomes among symptomatic patients with inconclusive EGJOO on HRM. Methods: Adult patients with inconclusive HRM‐EGJOO who completed corresponding FLIP and TBE studies were identified for inclusion in a cross‐sectional, retrospective study. Primary 4D HRM metrics of EGJ opening, EGJ distensibility index (4D EGJ‐DI), and 4D maximum EGJ diameter were analyzed relative to reference outcomes defined by FLIP and esophagram. Results: Among 123 patients (mean age 59 years; 60% female), 4D EGJ‐DI and 4D maximum EGJ diameter differed significantly across FLIP and TBE outcome categories (all p < 0.01). Lower 4D EGJ‐DI and lower 4D maximum EGJ diameter were associated with reduced EGJ opening on FLIP and abnormal retention on esophagram. There were 0 patients with normal EGJ opening on FLIP that had 4D maximum EGJ diameter < 8.0 mm and 0 patients with reduced EGJ opening on FLIP that had a 4D EGJ‐DI > 2.2 mm 2 /mmHg and 4D maximum EGJ diameter > 10.2 mm. Conclusions: By integrating biomechanical assessment of EGJ opening with conventional pressure metrics, 4D HRM provides complementary physiologic information for evaluating esophageal motor function. This additional information may improve characterization of patients with inconclusive EGJOO.
- 7 October 2026
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 38 (10)
Open AccessBiomechanical Assessment During High‐Resolution Impedance Manometry Enhances Characterization of Inconclusive Esophagogastric Junction Outflow Obstruction
Background: Esophagogastric junction outflow obstruction (EGJOO) identified on high‐resolution manometry (HRM) remains a clinically heterogeneous and inconclusive finding. Additional complementary testing with functional lumen imaging probe (FLIP) or timed barium esophagram (TBE) is recommended to confirm clinically relevant obstruction. We aimed to assess the association of novel Four‐Dimensional (4D) HRM metrics against FLIP and TBE outcomes among symptomatic patients with inconclusive EGJOO on HRM. Methods: Adult patients with inconclusive HRM‐EGJOO who completed corresponding FLIP and TBE studies were identified for inclusion in a cross‐sectional, retrospective study. Primary 4D HRM metrics of EGJ opening, EGJ distensibility index (4D EGJ‐DI), and 4D maximum EGJ diameter were analyzed relative to reference outcomes defined by FLIP and esophagram. Results: Among 123 patients (mean age 59 years; 60% female), 4D EGJ‐DI and 4D maximum EGJ diameter differed significantly across FLIP and TBE outcome categories (all p < 0.01). Lower 4D EGJ‐DI and lower 4D maximum EGJ diameter were associated with reduced EGJ opening on FLIP and abnormal retention on esophagram. There were 0 patients with normal EGJ opening on FLIP that had 4D maximum EGJ diameter < 8.0 mm and 0 patients with reduced EGJ opening on FLIP that had a 4D EGJ‐DI > 2.2 mm 2 /mmHg and 4D maximum EGJ diameter > 10.2 mm. Conclusions: By integrating biomechanical assessment of EGJ opening with conventional pressure metrics, 4D HRM provides complementary physiologic information for evaluating esophageal motor function. This additional information may improve characterization of patients with inconclusive EGJOO.
- 26 February 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 196, 257-270
Ex-vivo mechano-structural characterization of fresh diseased human esophagus
- 26 February 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 196, 257-270
Ex-vivo mechano-structural characterization of fresh diseased human esophagus
- 18 October 2024
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 120 (5) , 1019-1026
Four-Dimensional Impedance Manometry in Esophageal Motility Disorders
INTRODUCTION: Four-dimensional high-resolution impedance manometry (4D HRM) uses impedance to estimate esophageal luminal cross-sectional area and track nadir impedance to measure intrabolus pressure (IBP). We aimed to determine whether 4D HRM metrics could define abnormal esophagogastric junction (EGJ) opening between Chicago Classification version 4.0 motility disorders and compare 4D HRM with functional lumen imaging probe (FLIP) metrics. METHODS: Symptomatic adult patients who completed high-resolution impedance manometry and FLIP were included and compared with an asymptomatic control group. 4D HRM analysis used custom-built software to measure IBP, maximum EGJ diameter, and distensibility index on supine test swallows. 4D HRM metrics were compared with FLIP EGJ metrics. RESULTS: Ninety patients (31 normal motility, 16 ineffective esophageal manometry, 9 absent contractility, 8 conclusive EGJ outflow obstruction [EGJOO], 12 type I achalasia, 14 type II achalasia, 12 type III achalasia, and 34 asymptomatic controls) were included. Phase 2 and 3 IBP was higher in type II and III achalasia compared with controls and normal motility groups ( P < 0.03). Maximum EGJ diameter and EGJ-distensibility index in the conclusive EGJOO and achalasia groups were significantly lower than in controls and normal motility groups ( P < 0.03). 4D HRM identified 37 of 44 (84%) subjects with normal EGJ opening and 29 of 39 (74%) subjects with reduced EGJ opening on FLIP. DISCUSSION: 4D HRM metrics correlated with expected clinical observations across a spectrum of esophageal motility disorders and defined EGJ obstruction. 4D HRM metrics may have value in defining EGJ obstruction in equivocal cases related to EGJOO or absent peristalsis.
- 18 October 2024
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 120 (5) , 1019-1026
Four-Dimensional Impedance Manometry in Esophageal Motility Disorders
INTRODUCTION: Four-dimensional high-resolution impedance manometry (4D HRM) uses impedance to estimate esophageal luminal cross-sectional area and track nadir impedance to measure intrabolus pressure (IBP). We aimed to determine whether 4D HRM metrics could define abnormal esophagogastric junction (EGJ) opening between Chicago Classification version 4.0 motility disorders and compare 4D HRM with functional lumen imaging probe (FLIP) metrics. METHODS: Symptomatic adult patients who completed high-resolution impedance manometry and FLIP were included and compared with an asymptomatic control group. 4D HRM analysis used custom-built software to measure IBP, maximum EGJ diameter, and distensibility index on supine test swallows. 4D HRM metrics were compared with FLIP EGJ metrics. RESULTS: Ninety patients (31 normal motility, 16 ineffective esophageal manometry, 9 absent contractility, 8 conclusive EGJ outflow obstruction [EGJOO], 12 type I achalasia, 14 type II achalasia, 12 type III achalasia, and 34 asymptomatic controls) were included. Phase 2 and 3 IBP was higher in type II and III achalasia compared with controls and normal motility groups ( P < 0.03). Maximum EGJ diameter and EGJ-distensibility index in the conclusive EGJOO and achalasia groups were significantly lower than in controls and normal motility groups ( P < 0.03). 4D HRM identified 37 of 44 (84%) subjects with normal EGJ opening and 29 of 39 (74%) subjects with reduced EGJ opening on FLIP. DISCUSSION: 4D HRM metrics correlated with expected clinical observations across a spectrum of esophageal motility disorders and defined EGJ obstruction. 4D HRM metrics may have value in defining EGJ obstruction in equivocal cases related to EGJOO or absent peristalsis.
- Open Access
- 1 September 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (09) , 090501-8
Subsecond lung cancer detection within a heterogeneous background of normal and benign tissue using single-point Raman spectroscopy
SignificanceLung cancer is the most frequently diagnosed cancer overall and the deadliest cancer in North America. Early diagnosis through current bronchoscopy techniques is limited by poor diagnostic yield and low specificity, especially for lesions located in peripheral pulmonary locations. Even with the emergence of robotic-assisted platforms, bronchoscopy diagnostic yields remain below 80%.AimThe aim of this study was to determine whether in situ single-point fingerprint (800 to 1700 cm − 1) Raman spectroscopy coupled with machine learning could detect lung cancer within an otherwise heterogenous background composed of normal tissue and tissue associated with benign conditions, including emphysema and bronchiolitis.ApproachA Raman spectroscopy probe was used to measure the spectral fingerprint of normal, benign, and cancer lung tissue in 10 patients. Each interrogated specimen was characterized by histology to determine cancer type, i.e., small cell carcinoma or non-small cell carcinoma (adenocarcinoma and squamous cell carcinoma). Biomolecular information was extracted from the fingerprint spectra to identify biomolecular features that can be used for cancer detection.ResultsSupervised machine learning models were trained using leave-one-patient-out cross-validation, showing lung cancer could be detected with a sensitivity of 94% and a specificity of 80%.ConclusionsThis proof of concept demonstrates fingerprint Raman spectroscopy is a promising tool for the detection of lung cancer during diagnostic procedures and can capture biomolecular changes associated with the presence of cancer among a complex heterogeneous background within less than 1 s.
- 1 September 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (09) , 090501-8
Open AccessSubsecond lung cancer detection within a heterogeneous background of normal and benign tissue using single-point Raman spectroscopy
SignificanceLung cancer is the most frequently diagnosed cancer overall and the deadliest cancer in North America. Early diagnosis through current bronchoscopy techniques is limited by poor diagnostic yield and low specificity, especially for lesions located in peripheral pulmonary locations. Even with the emergence of robotic-assisted platforms, bronchoscopy diagnostic yields remain below 80%.AimThe aim of this study was to determine whether in situ single-point fingerprint (800 to 1700 cm − 1) Raman spectroscopy coupled with machine learning could detect lung cancer within an otherwise heterogenous background composed of normal tissue and tissue associated with benign conditions, including emphysema and bronchiolitis.ApproachA Raman spectroscopy probe was used to measure the spectral fingerprint of normal, benign, and cancer lung tissue in 10 patients. Each interrogated specimen was characterized by histology to determine cancer type, i.e., small cell carcinoma or non-small cell carcinoma (adenocarcinoma and squamous cell carcinoma). Biomolecular information was extracted from the fingerprint spectra to identify biomolecular features that can be used for cancer detection.ResultsSupervised machine learning models were trained using leave-one-patient-out cross-validation, showing lung cancer could be detected with a sensitivity of 94% and a specificity of 80%.ConclusionsThis proof of concept demonstrates fingerprint Raman spectroscopy is a promising tool for the detection of lung cancer during diagnostic procedures and can capture biomolecular changes associated with the presence of cancer among a complex heterogeneous background within less than 1 s.
- 5 November 2020
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 31 (6) , 847-852
Heat production during pulmonary artery sealing with energy vessel-sealing devices in a swine model
OBJECTIVES: Energy vessel-sealing devices are being increasingly utilized to seal pulmonary artery (PA) branches during lobectomy. Heat from these devices can potentially injure surrounding tissues. We evaluated heat production from devices in a live animal model. METHODS: PA branches were sealed in pigs with 4 energy vessel-sealing devices: 2 ultrasonic (US), 1 advanced bipolar or 1 mixed US and bipolar (mixed) device. Thermocouples were implanted in tissue surrounding the PA branch being sealed to measure tissue temperature. A thermal camera measured the sealing site and the temperatures of the instruments. Pathological analysis was performed on PA stumps to identify thermal damage. RESULTS: A total of 37 PA branches were sealed in 4 pigs. Maximum tissue heat measured by the thermocouples for the 2 US, advanced bipolar and mixed devices was 42, 39, 42 and 46°C, respectively. The mean tissue temperatures at the site of the sealing measured with the thermal camera were 78, 75, 70 and 82°C (P = 0.834) and the mean instrument blade temperatures were 224, 195, 83 and 170°C (P = 0.000005) for the 2 US, advanced bipolar and mixed devices, respectively. The mean diameter of the region with tissue reaching 60°C or more measured with the thermal camera was between 4 and 6 mm for the 4 devices (P = 0.941). On pathological analysis, PA stumps had either thermal damage on the adventitia and external media (26/37) or transmural damage (11/37) at 1 mm from sealed site. CONCLUSIONS: A 3-mm safety margin between the instrument blades and vital structures is recommended. Instrument blades can reach high temperatures that may cause tissue damage.
- 5 November 2020
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 31 (6) , 847-852
Heat production during pulmonary artery sealing with energy vessel-sealing devices in a swine model
OBJECTIVES: Energy vessel-sealing devices are being increasingly utilized to seal pulmonary artery (PA) branches during lobectomy. Heat from these devices can potentially injure surrounding tissues. We evaluated heat production from devices in a live animal model. METHODS: PA branches were sealed in pigs with 4 energy vessel-sealing devices: 2 ultrasonic (US), 1 advanced bipolar or 1 mixed US and bipolar (mixed) device. Thermocouples were implanted in tissue surrounding the PA branch being sealed to measure tissue temperature. A thermal camera measured the sealing site and the temperatures of the instruments. Pathological analysis was performed on PA stumps to identify thermal damage. RESULTS: A total of 37 PA branches were sealed in 4 pigs. Maximum tissue heat measured by the thermocouples for the 2 US, advanced bipolar and mixed devices was 42, 39, 42 and 46°C, respectively. The mean tissue temperatures at the site of the sealing measured with the thermal camera were 78, 75, 70 and 82°C (P = 0.834) and the mean instrument blade temperatures were 224, 195, 83 and 170°C (P = 0.000005) for the 2 US, advanced bipolar and mixed devices, respectively. The mean diameter of the region with tissue reaching 60°C or more measured with the thermal camera was between 4 and 6 mm for the 4 devices (P = 0.941). On pathological analysis, PA stumps had either thermal damage on the adventitia and external media (26/37) or transmural damage (11/37) at 1 mm from sealed site. CONCLUSIONS: A 3-mm safety margin between the instrument blades and vital structures is recommended. Instrument blades can reach high temperatures that may cause tissue damage.
- 1 January 2018
- Published by Elsevier in Operative Techniques in Thoracic and Cardiovascular Surgery
- Vol. 23 (3) , 136-150
Endosonographic Lymph Node Staging by Combined Endobronchial Ultrasound (EBUS) and Endoscopic Ultrasound: Technique and Technical Tricks
- 1 January 2018
- Published by Elsevier in Operative Techniques in Thoracic and Cardiovascular Surgery
- Vol. 23 (3) , 136-150
Endosonographic Lymph Node Staging by Combined Endobronchial Ultrasound (EBUS) and Endoscopic Ultrasound: Technique and Technical Tricks