Thomas Pilcher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thomas Pilcher has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Mary Niu
Department of Pediatrics, Division of Pediatric Cardiology, University of Utah Health Sciences Center, Primary Children's Hospital, 81 N. Mario Capecchi Drive, Salt Lake, UT 84113, USA
3 shared publications - Susan P. Etheridge
St Luke's Children's, Boise Idaho, and Stanford Lucile Packard Children's, Palo Alto, California
3 shared publications - Anne M. Dubin
Division of Pediatric Cardiology, Lucile Packard Children’s Hospital, Stanford University, Palo Alto, CA (A.M.D.).
2 shared publications - Douglas Y. Mah
Department of Cardiology Boston Children's Hospital Boston Massachusetts USA
2 shared publications - Jens Cosedis Nielsen
Department of Cardiology, Aarhus University Hospital , Aarhus
2 shared publications - Jeremy P. Moore
University of California Los Angeles (UCLA) Cardiac Arrhythmia Center, UCLA Health System , Los Angeles, CA
2 shared publications
Latest Publications
- Open Access
- 30 July 2025
- Published by Elsevier in Heart Rhythm
- Vol. 22 (8) , 2144-2145
Top stories: New technology in pediatric ablation
- 30 July 2025
- Published by Elsevier in Heart Rhythm
- Vol. 22 (8) , 2144-2145
Open AccessTop stories: New technology in pediatric ablation
- Open Access
- 1 March 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (3)
Before it is too late: pre-emptive ablation strategies in tetralogy of Fallot
This editorial refers to ‘Automated isochronal late activation mapping for substrate characterization in patients with repaired tetralogy of Fallot’, by E. Arana-Rueda et al., https://doi.org/10.1093/europace/euae062.
- 1 March 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (3)
Open AccessBefore it is too late: pre-emptive ablation strategies in tetralogy of Fallot
This editorial refers to ‘Automated isochronal late activation mapping for substrate characterization in patients with repaired tetralogy of Fallot’, by E. Arana-Rueda et al., https://doi.org/10.1093/europace/euae062.
- 1 March 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (3) , e012363
Long-Term Outcomes of Cardiac Resynchronization Therapy in Patients With Repaired Tetralogy of Fallot: A Multicenter Study
BACKGROUND: A growing number of patients with tetralogy of Fallot develop left ventricular systolic dysfunction and heart failure, in addition to right ventricular dysfunction. Although cardiac resynchronization therapy (CRT) is an established treatment option, the effect of CRT in this population is still not well defined. This study aimed to investigate the early and late efficacy, survival, and safety of CRT in patients with tetralogy of Fallot. METHODS: Data were analyzed from an observational, retrospective, multicenter cohort, initiated jointly by the Pediatric and Congenital Electrophysiology Society and the International Society of Adult Congenital Heart Disease. Twelve centers contributed baseline and longitudinal data, including vital status, left ventricular ejection fraction (LVEF), QRS duration, and NYHA functional class. Outcomes were analyzed at early (3 months), intermediate (1 year), and late follow-up (≥2 years) after CRT implantation. RESULTS: A total of 44 patients (40.3±19.2 years) with tetralogy of Fallot and CRT were enrolled. Twenty-nine (65.9%) patients had right ventricular pacing before CRT upgrade. The left ventricular ejection fraction improved from 32% [24%–44%] at baseline to 42% [32%–50%] at early follow-up ( P P ≤0.002). The QRS duration decreased from 180 [160–205] ms at baseline to 152 [133–182] ms at early follow-up ( P P ≤0.001). Patients with upgraded CRT had consistent improvement in left ventricular ejection fraction and QRS duration at each time point ( P ≤0.004). Patients had a significantly improved New York Heart Association functional class after CRT implantation at each time point compared with baseline ( P ≤0.002). The transplant-free survival rates at 3, 5, and 8 years after CRT implantation were 85%, 79%, and 73%. CONCLUSIONS: In patients with tetralogy of Fallot treated with CRT consistent improvement in QRS duration, left ventricular ejection fraction, New York Heart Association functional class, and reasonable long-term survival were observed. The findings from this multicenter study support the consideration of CRT in this unique population.
- 1 March 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (3) , e012363
Long-Term Outcomes of Cardiac Resynchronization Therapy in Patients With Repaired Tetralogy of Fallot: A Multicenter Study
BACKGROUND: A growing number of patients with tetralogy of Fallot develop left ventricular systolic dysfunction and heart failure, in addition to right ventricular dysfunction. Although cardiac resynchronization therapy (CRT) is an established treatment option, the effect of CRT in this population is still not well defined. This study aimed to investigate the early and late efficacy, survival, and safety of CRT in patients with tetralogy of Fallot. METHODS: Data were analyzed from an observational, retrospective, multicenter cohort, initiated jointly by the Pediatric and Congenital Electrophysiology Society and the International Society of Adult Congenital Heart Disease. Twelve centers contributed baseline and longitudinal data, including vital status, left ventricular ejection fraction (LVEF), QRS duration, and NYHA functional class. Outcomes were analyzed at early (3 months), intermediate (1 year), and late follow-up (≥2 years) after CRT implantation. RESULTS: A total of 44 patients (40.3±19.2 years) with tetralogy of Fallot and CRT were enrolled. Twenty-nine (65.9%) patients had right ventricular pacing before CRT upgrade. The left ventricular ejection fraction improved from 32% [24%–44%] at baseline to 42% [32%–50%] at early follow-up ( P P ≤0.002). The QRS duration decreased from 180 [160–205] ms at baseline to 152 [133–182] ms at early follow-up ( P P ≤0.001). Patients with upgraded CRT had consistent improvement in left ventricular ejection fraction and QRS duration at each time point ( P ≤0.004). Patients had a significantly improved New York Heart Association functional class after CRT implantation at each time point compared with baseline ( P ≤0.002). The transplant-free survival rates at 3, 5, and 8 years after CRT implantation were 85%, 79%, and 73%. CONCLUSIONS: In patients with tetralogy of Fallot treated with CRT consistent improvement in QRS duration, left ventricular ejection fraction, New York Heart Association functional class, and reasonable long-term survival were observed. The findings from this multicenter study support the consideration of CRT in this unique population.
- Open Access
- 1 February 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (2)
Intracardiac echocardiography in paediatric and congenital cardiac ablation shortens procedure duration and improves success without complications
Common to adult electrophysiology studies (EPSs), intracardiac echocardiography (ICE) use in paediatric and congenital heart disease (CHD) EPS is limited. The purpose of this study was to assess the efficacy of ICE use and incidence of associated complications in paediatric and CHD EPS. This single-centre retrospective matched cohort study reviewed EPS between 2013 and 2022. Demographics, CHD type, and EPS data were collected. Intracardiac echocardiography cases were matched 1:1 to no ICE controls to assess differences in complications, ablation success, fluoroscopy exposure, procedure duration, and arrhythmia recurrence. Cases and controls with preceding EPS within 5 years were excluded. Intracardiac echocardiography cases without an appropriate match were excluded from comparative analyses but included in the descriptive cohort. We performed univariable and multivariable logistic regression to assess associations between variables and outcomes. A total of 335 EPS were reviewed, with ICE used in 196. The median age of ICE cases was 15 [interquartile range (IQR) 12–17; range 3–47] years, and median weight 57 [IQR 45–71; range 15–134] kg. There were no ICE-related acute or post-procedural complications. There were 139 ICE cases matched to no ICE controls. Baseline demographics and anthropometrics were similar between cases and controls. Fluoroscopy exposure (P = 0.02), procedure duration (P = 0.01), and arrhythmia recurrence (P = 0.01) were significantly lower in ICE cases. Intracardiac echocardiography in paediatric and CHD ablations is safe and reduces procedure duration, fluoroscopy exposure, and arrhythmia recurrence. However, not every arrhythmia substrate requires ICE use. Thoughtful selection will ensure the judicious and strategic application of ICE to enhance outcomes.
- 1 February 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (2)
Open AccessIntracardiac echocardiography in paediatric and congenital cardiac ablation shortens procedure duration and improves success without complications
Common to adult electrophysiology studies (EPSs), intracardiac echocardiography (ICE) use in paediatric and congenital heart disease (CHD) EPS is limited. The purpose of this study was to assess the efficacy of ICE use and incidence of associated complications in paediatric and CHD EPS. This single-centre retrospective matched cohort study reviewed EPS between 2013 and 2022. Demographics, CHD type, and EPS data were collected. Intracardiac echocardiography cases were matched 1:1 to no ICE controls to assess differences in complications, ablation success, fluoroscopy exposure, procedure duration, and arrhythmia recurrence. Cases and controls with preceding EPS within 5 years were excluded. Intracardiac echocardiography cases without an appropriate match were excluded from comparative analyses but included in the descriptive cohort. We performed univariable and multivariable logistic regression to assess associations between variables and outcomes. A total of 335 EPS were reviewed, with ICE used in 196. The median age of ICE cases was 15 [interquartile range (IQR) 12–17; range 3–47] years, and median weight 57 [IQR 45–71; range 15–134] kg. There were no ICE-related acute or post-procedural complications. There were 139 ICE cases matched to no ICE controls. Baseline demographics and anthropometrics were similar between cases and controls. Fluoroscopy exposure (P = 0.02), procedure duration (P = 0.01), and arrhythmia recurrence (P = 0.01) were significantly lower in ICE cases. Intracardiac echocardiography in paediatric and CHD ablations is safe and reduces procedure duration, fluoroscopy exposure, and arrhythmia recurrence. However, not every arrhythmia substrate requires ICE use. Thoughtful selection will ensure the judicious and strategic application of ICE to enhance outcomes.
- Open Access
- 8 November 2022
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 11 (22) , e025121
Cardiac Resynchronization Therapy for Adult Patients With a Failing Systemic Right Ventricle: A Multicenter Study
Background: The objective of this international multicenter study was to investigate both early and late outcomes of cardiac resynchronization therapy (CRT) in patients with a systemic right ventricle (SRV) and to identify predictors for congestive heart failure readmissions and mortality. Methods and Results: This retrospective international multicenter study included 13 centers. The study population comprised 80 adult patients with SRV (48.9% women) with a mean age of 45±14 (range, 18–77) years at initiation of CRT. Median follow‐up time was 4.1 (25th–75th percentile, 1.3–8.3) years. Underlying congenital heart disease consisted of congenitally corrected transposition of the great arteries and dextro‐transposition of the great arteries in 63 (78.8%) and 17 (21.3%) patients, respectively. CRT resulted in significant improvement in functional class (before CRT: III, 25th–75th percentile, II–III; after CRT: II, 25th–75th percentile, II–III; P =0.005) and QRS duration (before CRT: 176±27; after CRT: 150±24 milliseconds; P =0.003) in patients with pre‐CRT ventricular pacing who underwent an upgrade to a CRT device (n=49). These improvements persisted during long‐term follow‐up with a marginal but significant increase in SRV function (before CRT; 30%, 25th–75th percentile, 25–35; after CRT: 31%, 25th–75th percentile, 21–38; P =0.049). In contrast, no beneficial change in the above‐mentioned variables was observed in patients who underwent de novo CRT (n=31). A quarter of all patients were readmitted for heart failure during follow‐up, and mortality at latest follow‐up was 21.3%. Conclusions: This international experience with CRT in patients with an SRV demonstrated that CRT in selected patients with SRV dysfunction and pacing‐induced dyssynchrony yielded consistent improvement in QRS duration and New York Heart Association functional status, with a marginal increase in SRV function.
- 8 November 2022
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 11 (22) , e025121
Open AccessCardiac Resynchronization Therapy for Adult Patients With a Failing Systemic Right Ventricle: A Multicenter Study
Background: The objective of this international multicenter study was to investigate both early and late outcomes of cardiac resynchronization therapy (CRT) in patients with a systemic right ventricle (SRV) and to identify predictors for congestive heart failure readmissions and mortality. Methods and Results: This retrospective international multicenter study included 13 centers. The study population comprised 80 adult patients with SRV (48.9% women) with a mean age of 45±14 (range, 18–77) years at initiation of CRT. Median follow‐up time was 4.1 (25th–75th percentile, 1.3–8.3) years. Underlying congenital heart disease consisted of congenitally corrected transposition of the great arteries and dextro‐transposition of the great arteries in 63 (78.8%) and 17 (21.3%) patients, respectively. CRT resulted in significant improvement in functional class (before CRT: III, 25th–75th percentile, II–III; after CRT: II, 25th–75th percentile, II–III; P =0.005) and QRS duration (before CRT: 176±27; after CRT: 150±24 milliseconds; P =0.003) in patients with pre‐CRT ventricular pacing who underwent an upgrade to a CRT device (n=49). These improvements persisted during long‐term follow‐up with a marginal but significant increase in SRV function (before CRT; 30%, 25th–75th percentile, 25–35; after CRT: 31%, 25th–75th percentile, 21–38; P =0.049). In contrast, no beneficial change in the above‐mentioned variables was observed in patients who underwent de novo CRT (n=31). A quarter of all patients were readmitted for heart failure during follow‐up, and mortality at latest follow‐up was 21.3%. Conclusions: This international experience with CRT in patients with an SRV demonstrated that CRT in selected patients with SRV dysfunction and pacing‐induced dyssynchrony yielded consistent improvement in QRS duration and New York Heart Association functional status, with a marginal increase in SRV function.
- 13 June 2020
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 43 (8) , 797-804
MRI in pediatric and congenital heart disease patients with CIEDs and epicardial or abandoned leads
Background: Heart Rhythm Society guidelines outlining magnetic resonance imaging (MRI) in patients with cardiac implantable electronic devices (CIEDs) excluded children and epicardial or abandoned leads due to theoretical risks of harm. Research investigating these risks is lacking. The primary objective of our study is to determine the incidence of adverse events to patients or CIEDs from MRI imaging. The secondary objective is to describe CIED‐related artifact on MRI images.Methods: A single‐center retrospective review was performed on all patients with CIEDs who underwent 1.5 Tesla MRI between July 2007 and May 2019. We subdivided patients among four cohorts: (1) patients <18 years of age, (2) epicardial leads, (3) abandoned endocardial leads, and (4) abandoned epicardial leads. Descriptive statistics pre‐ and post‐MRI and at follow‐up within 1.5 years were conducted.Results: Fifty‐four MRIs were performed on 40 patients. Median age was 21.2 years (IQR 12.0‐25.0). Eighteen (33%) MRIs contained abandoned leads; 20 (37%) contained epicardial leads. Three patients, one with abandoned epicardial leads and two with abandoned endocardial leads, experienced mild discomfort at the CIED site. One adult with endocardial leads experienced a pause in the heart rate while programmed in a nonpacing mode. No clinically important changes to CIED parameters occurred. Nine MRIs (17%), especially those with functional cardiac imaging, were uninterpretable due to image artifact.Conclusion: In this study, pediatric and adult CHD patients with CIEDs, many with epicardial or abandoned leads, underwent MRIs without clinically significant complications. In some, CIED artifact reduced cardiac MRI image quality due to CIED position.
- 13 June 2020
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 43 (8) , 797-804
MRI in pediatric and congenital heart disease patients with CIEDs and epicardial or abandoned leads
Background: Heart Rhythm Society guidelines outlining magnetic resonance imaging (MRI) in patients with cardiac implantable electronic devices (CIEDs) excluded children and epicardial or abandoned leads due to theoretical risks of harm. Research investigating these risks is lacking. The primary objective of our study is to determine the incidence of adverse events to patients or CIEDs from MRI imaging. The secondary objective is to describe CIED‐related artifact on MRI images.Methods: A single‐center retrospective review was performed on all patients with CIEDs who underwent 1.5 Tesla MRI between July 2007 and May 2019. We subdivided patients among four cohorts: (1) patients <18 years of age, (2) epicardial leads, (3) abandoned endocardial leads, and (4) abandoned epicardial leads. Descriptive statistics pre‐ and post‐MRI and at follow‐up within 1.5 years were conducted.Results: Fifty‐four MRIs were performed on 40 patients. Median age was 21.2 years (IQR 12.0‐25.0). Eighteen (33%) MRIs contained abandoned leads; 20 (37%) contained epicardial leads. Three patients, one with abandoned epicardial leads and two with abandoned endocardial leads, experienced mild discomfort at the CIED site. One adult with endocardial leads experienced a pause in the heart rate while programmed in a nonpacing mode. No clinically important changes to CIED parameters occurred. Nine MRIs (17%), especially those with functional cardiac imaging, were uninterpretable due to image artifact.Conclusion: In this study, pediatric and adult CHD patients with CIEDs, many with epicardial or abandoned leads, underwent MRIs without clinically significant complications. In some, CIED artifact reduced cardiac MRI image quality due to CIED position.
- 18 February 2019
- Published by Springer Nature in Current Cardiovascular Risk Reports
- Vol. 13 (3) , 1-9
The Role of Atrial Arrhythmia Ablation in Adolescent and Adult Congenital Heart Disease
- 18 February 2019
- Published by Springer Nature in Current Cardiovascular Risk Reports
- Vol. 13 (3) , 1-9
The Role of Atrial Arrhythmia Ablation in Adolescent and Adult Congenital Heart Disease