MRI in pediatric and congenital heart disease patients with CIEDs and epicardial or abandoned leads
- 13 June 2020
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 43 (8) , 797-804
Abstract
Background: Heart Rhythm Society guidelines outlining magnetic resonance imaging (MRI) in patients with cardiac implantable electronic devices (CIEDs) excluded children and epicardial or abandoned leads due to theoretical risks of harm. Research investigating these risks is lacking. The primary objective of our study is to determine the incidence of adverse events to patients or CIEDs from MRI imaging. The secondary objective is to describe CIED‐related artifact on MRI images.Methods: A single‐center retrospective review was performed on all patients with CIEDs who underwent 1.5 Tesla MRI between July 2007 and May 2019. We subdivided patients among four cohorts: (1) patients <18 years of age, (2) epicardial leads, (3) abandoned endocardial leads, and (4) abandoned epicardial leads. Descriptive statistics pre‐ and post‐MRI and at follow‐up within 1.5 years were conducted.Results: Fifty‐four MRIs were performed on 40 patients. Median age was 21.2 years (IQR 12.0‐25.0). Eighteen (33%) MRIs contained abandoned leads; 20 (37%) contained epicardial leads. Three patients, one with abandoned epicardial leads and two with abandoned endocardial leads, experienced mild discomfort at the CIED site. One adult with endocardial leads experienced a pause in the heart rate while programmed in a nonpacing mode. No clinically important changes to CIED parameters occurred. Nine MRIs (17%), especially those with functional cardiac imaging, were uninterpretable due to image artifact.Conclusion: In this study, pediatric and adult CHD patients with CIEDs, many with epicardial or abandoned leads, underwent MRIs without clinically significant complications. In some, CIED artifact reduced cardiac MRI image quality due to CIED position.Keywords
Funding Information
- National Center for Research Resources
- National Center for Advancing Translational Sciences
This publication has 26 references indexed in Scilit:
- Quantitative Assessment of Artifacts on Cardiac Magnetic Resonance Imaging of Patients With Pacemakers and Implantable Cardioverter-DefibrillatorsCirculation: Cardiovascular Imaging, 2011
- Safety of serial MRI in patients with implantable cardioverter defibrillatorsHeart, 2011
- Pacemaker lead tip heating in abandoned and pacemaker‐attached leads at 1.5 tesla MRIJournal of Magnetic Resonance Imaging, 2011
- Magnetic resonance imaging in patients with cardiac pacemakers: era of “MR Conditional” designsJournal of Cardiovascular Magnetic Resonance, 2011
- Cardiac pacing in infants and childrenHeart, 2010
- Safety and Imaging Quality of MRI in Pediatric and Adult Congenital Heart Disease Patients with PacemakersPacing and Clinical Electrophysiology, 2009
- Atrial Threshold Variability: Implications for Automatic Atrial Stimulation AlgorithmsPacing and Clinical Electrophysiology, 2007
- Ventricular Pacing Threshold Variations in the YoungPacing and Clinical Electrophysiology, 2007
- Strategy for Safe Performance of Extrathoracic Magnetic Resonance Imaging at 1.5 Tesla in the Presence of Cardiac Pacemakers in Non–Pacemaker-Dependent PatientsCirculation, 2006
- Safety of MR imaging in patients who have retained metallic materials after cardiac surgery.American Journal of Roentgenology, 1997