EDEmmanouil Dimitrakakis

Emmanouil Dimitrakakis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Emmanouil Dimitrakakis has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Danail Stoyanov

    Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, United Kingdom

    4 shared publications
  • George Dwyer

    Panda Surgical Limited, London, United Kingdom

    4 shared publications
  • Hani J. Marcus

    Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, United Kingdom

    4 shared publications
  • Danail Stoyanov

    University College London

    3 shared publications
  • Hani J. Marcus

    Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, Victor Horsley, UCL Queen Square Institute of Neurology, University College London, London, UK

    3 shared publications
  • Lukas Lindenroth

    Wellcome/EPSRC Centre for Surgical and Interventional Sciences (WEISS), University College London (UCL), London, UK

    3 shared publications

Latest Publications

  • Open Access

    A Scoping Review of the Ergonomics of Handheld Surgical Robots

    by Joseph Shehata, Tjasa Zaletel, Shuja Yaqub, Joachim Starup-Hansen, Emmanouil Dimitrakakis, John G Hanrahan, Danail Stoyanov, Hani J Marcus

    Handheld surgical robots aim to improve dexterity with lower cost and footprint than console systems, but their ergonomic impact is unclear. We performed a scoping review (inception − 27 July 2025) of English-language primary studies of handheld robotic instruments across six databases and targeted grey literature. Dual-reviewer screening and charting were used, with narrative synthesis. From 2,675 records, 79 studies met inclusion: 21 evaluated ergonomics. Most relied on subjective questionnaires; validated workload tools (NASA-TLX/SURG-TLX) and objective measures (RULA, wearables) were uncommon. Twelve commercial systems were identified; only three had peer-reviewed ergonomic data. Reported ergonomic aims included reducing weight, maintaining neutral wrist posture and intuitive control mapping; sex-disaggregated outcomes were rare. Evidence remains heterogeneous and insufficiently standardised; we recommend hybrid, validated protocols and inclusive design to ensure safe, equitable adoption.

  • Open Access

    Applicability of a Dexterity-Enhancing Handheld Robot for 360° Endoscopic Skull Base Approaches: An Exploratory Cadaver Study

    by Joachim Starup-Hansen, Dan Zimelewicz Oberman, John G. Hanrahan, Emmanouil Dimitrakakis, Hani J. Marcus, Joao Paulo Almeida

    BACKGROUND AND OBJECTIVES: Endoscopic skull base surgery aims to reduce surgical morbidity by minimizing tissue manipulation and exposure. However, the anatomic constraints posed by the narrow surgical corridors and constrained operative workspace present technical challenges due to reduced dexterity. This study evaluates the applicability of a novel dexterity-enhancing handheld robot for endoscopic skull base approaches. METHODS: The robotic system is comprised of interchangeable articulated end-effectors coupled to a handheld controller. Two attending skull base neurosurgeons and 2 neurosurgery residents performed 8 skull base approaches on cadaveric specimens, spanning anterior, anterolateral, lateral, posterolateral, and posterior approaches. Conventional instruments were used to expose anatomic landmarks, followed by intraoperative tasks using the handheld robot. Participants were interviewed during the procedures to assess the robot's feasibility (ability to safely reach and perform its objective of manipulating tissue at the operative site) and usefulness (ability to perform desired objectives well). RESULTS: The handheld robotic system was tested across 8 endoscopic skull base approaches, achieving feasibility in all cases. Superior workspace reach compared with standard instruments was demonstrated in 6 of 8 approaches. Tissue manipulation was satisfactory in all approaches. All surgeons reported that the current or a future device prototype could be useful across all 8 approaches. The most frequently cited advantage was the expanded dextrous workspace reach provided by the articulated end-effectors, particularly in approaches with long working channels, such as the endonasal approach. However, the robot encountered difficulties in transcranial approaches (trans-sylvian and subtemporal) due to the lack of shorter, curved shafts, which impaired visualization. CONCLUSION: The handheld robotic system demonstrated applicability across various endoscopic skull base approaches, offering increased dextrous workspace and effective tissue manipulation capabilities. Overall, this study supports the potential of handheld robots in endoscopic skull base surgery while highlighting the need for iterative development to optimize instrument design and functionality.


  • Open Access

    Handheld robotic device for endoscopic neurosurgery: system integration and pre-clinical evaluation

    by Emmanouil Dimitrakakis, George Dwyer, Nicola Newall, Danyal Z. Khan, Hani J. Marcus, Danail Stoyanov

    The Expanded Endoscopic Endonasal Approach, one of the best examples of endoscopic neurosurgery, allows access to the skull base through the natural orifice of the nostril. Current standard instruments lack articulation limiting operative access and surgeon dexterity, and thus, could benefit from robotic articulation. In this study, a handheld robotic system with a series of detachable end-effectors for this approach is presented. This system is comprised of interchangeable articulated 2/3 degrees-of-freedom 3 mm instruments that expand the operative workspace and enhance the surgeon’s dexterity, an ergonomically designed handheld controller with a rotating joystick-body that can be placed at the position most comfortable for the user, and the accompanying control box. The robotic instruments were experimentally evaluated for their workspace, structural integrity, and force-delivery capabilities. The entire system was then tested in a pre-clinical context during a phantom feasibility test, followed up by a cadaveric pilot study by a cohort of surgeons of varied clinical experience. Results from this series of experiments suggested enhanced dexterity and adequate robustness that could be associated with feasibility in a clinical context, as well as improvement over current neurosurgical instruments.


  • Open Access

    Specialised Surgical Instruments for Endoscopic and Endoscope-Assisted Neurosurgery: A Systematic Review of Safety, Efficacy and Usability

    by Holly Aylmore, Emmanouil Dimitrakakis, Joshua Carmichael, Danyal Z. Khan, Danail Stoyanov, Neil L. Dorward, Hani J. Marcus

    While there have been great strides in endoscopic and endoscope-assisted neurosurgical approaches, particularly in the treatment of deep-sited brain and skull base tumours, the greatest technical barrier to their adoption has been the availability of suitable surgical instruments. This systematic review seeks to identify specialised instruments for these approaches and evaluate their safety, efficacy and usability. Conducted in accordance with the PRISMA guidelines, Medline, Embase, CENTRAL, SCOPUS and Web of Science were searched. Original research studies that reported the use of specialised mechanical instruments that manipulate tissue in human patients, cadavers or surgical models were included. The results identified 50 specialised instruments over 62 studies. Objective measures of safety were reported in 32 out of 62 studies, and 20 reported objective measures of efficacy. Instruments were broadly safe and effective with one instrument malfunction noted. Measures of usability were reported in 15 studies, with seven reporting on ergonomics and eight on the instruments learning curve. Instruments with reports on usability were generally considered to be ergonomic, though learning curve was often considered a disadvantage. Comparisons to standard instruments were made in eight studies and were generally favourable. While there are many specialised instruments for endoscopic and endoscope-assisted neurosurgery available, the evidence for their safety, efficacy and usability is limited with non-standardised reporting and few comparative studies to standard instruments. Future innovation should be tailored to unmet clinical needs, and evaluation guided by structured development processes.


  • Open Access

    Robotic Handle Prototypes for Endoscopic Endonasal Skull Base Surgery: Pre-clinical Randomised Controlled Trial of Performance and Ergonomics

    by Emmanouil Dimitrakakis, Holly Aylmore, Lukas Lindenroth, George Dwyer, Joshua Carmichael, Danyal Z. Khan, Neil L. Dorward, Hani J. Marcus, Danail Stoyanov

    Endoscopic endonasal skull base surgery is a promising alternative to transcranial approaches. However, standard instruments lack articulation, and thus, could benefit from robotic technologies. The aim of this study was to develop an ergonomic handle for a handheld robotic instrument intended to enhance this procedure. Two different prototypes were developed based on ergonomic guidelines within the literature. The first is a forearm-mounted handle that maps the surgeon’s wrist degrees-of-freedom to that of the robotic end-effector; the second is a joystick-and-trigger handle with a rotating body that places the joystick to the position most comfortable for the surgeon. These handles were incorporated into a custom-designed surgical virtual simulator and were assessed for their performance and ergonomics when compared with a standard neurosurgical grasper. The virtual task was performed by nine novices with all three devices as part of a randomised crossover user-study. Their performance and ergonomics were evaluated both subjectively by themselves and objectively by a validated observational checklist. Both handles outperformed the standard instrument with the rotating joystick-body handle offering the most substantial improvement in terms of balance between performance and ergonomics. Thus, it is deemed the more suitable device to drive instrumentation for endoscopic endonasal skull base surgery.


  • Open Access

    An intuitive surgical handle design for robotic neurosurgery

    by Emmanouil Dimitrakakis, Lukas Lindenroth, George Dwyer, Holly Aylmore, Neil L. Dorward, Hani J. Marcus, Danail Stoyanov

    Purpose: The expanded endoscopic endonasal approach, a representative example of keyhole brain surgery, allows access to the pituitary gland and surrounding areas through the nasal and sphenoid cavities. Manipulating rigid instruments through these constrained spaces makes this approach technically challenging, and thus, a handheld robotic instrument could expand the surgeon’s capabilities. In this study, we present an intuitive handle prototype for such a robotic instrument. Methods: We have designed and fabricated a surgical instrument handle prototype that maps the surgeon’s wrist directly to the robot joints. To alleviate the surgeon’s wrist of any excessive strain and fatigue, the tool is mounted on the surgeon’s forearm, making it parallel with the instrument’s shaft. To evaluate the handle’s performance and limitations, we constructed a surgical task simulator and compared our novel handle with a standard neurosurgical tool, with the tasks being performed by a consultant neurosurgeon. Results: While using the proposed handle, the surgeon’s average success rate was $$80\%$$ 80 % , compared to $$41\%$$ 41 % when using a conventional tool. Additionally, the surgeon’s body posture while using the suggested prototype was deemed acceptable by the Rapid Upper Limb Assessment ergonomic survey, while early results indicate the absence of a learning curve. Conclusions: Based on these preliminary results, the proposed handle prototype could offer an improvement over current neurosurgical tools and procedural ergonomics. By redirecting forces applied during the procedure to the forearm of the surgeon, and allowing for intuitive surgeon wrist to robot-joints movement mapping without compromising the robotic end effector’s expanded workspace, we believe that this handle could prove a substantial step toward improved neurosurgical instrumentation.


  • A Spherical Joint Robotic End-Effector for the Expanded Endoscopic Endonasal Approach

    by Emmanouil Dimitrakakis, George Dwyer, Lukas Lindenroth, Petros Giataganas, Neil L. Dorward, Hani J. Marcus, Danail Stoyanov


  • Open Access

    Pneumatically Attachable Flexible Rails for Track-Guided Ultrasound Scanning in Robotic-Assisted Partial Nephrectomy—A Preliminary Design Study

    by Agostino Stilli, Emmanouil Dimitrakakis, Claudia D'Ettorre, Maxine Tran, Danail Stoyanov

    Robotic-assisted partial nephrectomy is a surgical operation in which part of a kidney is removed typically because of the presence of a mass. Pre-operative and intraoperative imaging techniques are used to identify and outline the target mass, thus the margins of the resection area on the kidney surface. Drop-in ultrasound probes are used to acquire intraoperative images: the probe is inserted through a trocar port, grasped with a robotic-assisted laparoscopic gripper and swiped on the kidney surface. Multiple swipes are performed to define the resection area. This is marked swipe by swipe using an electrocautery tool. During this procedure the probe often requires repositioning because of slippage from the target organ surface. Furthermore, the localization can be inaccurate when the target mass is in locations particularly hard to reach, and thus kidney repositioning could be required. A highly skilled surgeon is typically required to successfully perform this pre-operatory procedure. We propose a novel approach for the navigation of drop-in ultrasound probes: the use of pneumatically attachable flexible rails to enable swift, effortless and accurate track-guided scanning of the kidney. The proposed system attaches on the kidney side surface with the use of a series of bio-inspired vacuum suckers. In this paper the design of the proposed system and its use in robotic-assisted partial nephrectomy are presented for the first time.