CBColleen Bailey

Colleen Bailey

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Colleen Bailey has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    VERDICT MRI validation in fresh and fixed prostate specimens using patient‐specific moulds for histological and MR alignment

    by Colleen Bailey, Roger M. Bourne, Bernard Siow, Edward W. Johnston, Mrishta Brizmohun Appayya, Hayley Pye, Susan Heavey, Thomy Mertzanidou, Hayley Whitaker, Alex Freeman, et al.

    The VERDICT framework for modelling diffusion MRI data aims to relate parameters from a biophysical model to histological features used for tumour grading in prostate cancer. Validation of the VERDICT model is necessary for clinical use. This study compared VERDICT parameters obtained ex vivo with histology in five specimens from radical prostatectomy. A patient‐specific 3D‐printed mould was used to investigate the effects of fixation on VERDICT parameters and to aid registration to histology. A rich diffusion data set was acquired in each ex vivo prostate before and after fixation. At both time points, data were best described by a two‐compartment model: the model assumes that an anisotropic tensor compartment represents the extracellular space and a restricted sphere compartment models the intracellular space. The effect of fixation on model parameters associated with tissue microstructure was small. The patient‐specific mould minimized tissue deformations and co‐localized slices, so that rigid registration of MRI to histology images allowed region‐based comparison with histology. The VERDICT estimate of the intracellular volume fraction corresponded to histological indicators of cellular fraction, including high values in tumour regions. The average sphere radius from VERDICT, representing the average cell size, was relatively uniform across samples. The primary diffusion direction from the extracellular compartment of the VERDICT model aligned with collagen fibre patterns in the stroma obtained by structure tensor analysis. This confirmed the biophysical relationship between ex vivo VERDICT parameters and tissue microstructure from histology.


  • Open Access

    Microstructure Characterization of Bone Metastases from Prostate Cancer with Diffusion MRI: Preliminary Findings

    by Colleen Bailey, David J. Collins, Nina Tunariu, Matthew R. Orton, Veronica A. Morgan, Thorsten Feiweier, David J. Hawkes, Martin O. Leach, Daniel C. Alexander, Eleftheria Panagiotaki

    Purpose: To examine the usefulness of rich diffusion protocols with high b-values and varying diffusion time for probing microstructure in bone metastases. Analysis techniques including biophysical and mathematical models were compared with the clinical apparent diffusion coefficient (ADC). Methods: Four patients were scanned using 13 b-values up to 3,000 s/mm2 and diffusion times ranging 18–52 ms. Data were fitted to mono-exponential ADC, intravoxel incoherent motion (IVIM), Kurtosis and Vascular, extracellular, and restricted diffusion for cytometry in tumors (VERDICT) models. Parameters from the models were compared using correlation plots. Results: ADC and IVIM did not fit the data well, failing to capture the signal at high b-values. The Kurtosis model best explained the data in many voxels, but in voxels exhibiting a more time-dependent signal, the VERDICT model explained the data best. The ADC correlated significantly (p < 0.004) with the intracellular diffusion coefficient (r = 0.48), intracellular volume fraction (r = −0.21), and perfusion fraction (r = 0.46) parameters from VERDICT, suggesting that these factors all contribute to ADC contrast. The mean kurtosis correlated with the intracellular volume fraction parameter (r = 0.26) from VERDICT, consistent with the hypothesis that kurtosis relates to cellularity, but also correlated weakly with the intracellular diffusion coefficient (r = 0.18) and cell radius (r = 0.16) parameters, suggesting that it may be difficult to attribute physical meaning to kurtosis. Conclusion: Both Kurtosis and VERDICT explained the diffusion signal better than ADC and IVIM, primarily due to poor fitting at high b-values in the latter two models. The Kurtosis and VERDICT models captured information at high b using parameters (Kurtosis or intracellular volume fraction and radius) that do not have a simple relationship with ADC and that may provide additional microstructural information in bone metastases.


  • The prognostic and predictive value of vascular response parameters measured by dynamic contrast-enhanced-CT, -MRI and -US in patients with metastatic renal cell carcinoma receiving sunitinib

    by John M. Hudson, Colleen Bailey, Mostafa Atri, Greg Stanisz, Laurent Milot, Ross Williams, Alex Kiss, Peter N. Burns, Georg A. Bjarnason

    To identify dynamic contrast-enhanced (DCE) imaging parameters from MRI, CT and US that are prognostic and predictive in patients with metastatic renal cell cancer (mRCC) receiving sunitinib.


  • Water Exchange Rate Constant as a Biomarker of Treatment Efficacy in Patients With Brain Metastases Undergoing Stereotactic Radiosurgery

    by Hatef Mehrabian, Kimberly L. Desmond, Sofia Chavez, Colleen Bailey, Radoslaw Rola, Arjun Sahgal, Gregory J. Czarnota, Hany Soliman, Anne L. Martel, Greg J. Stanisz


  • Open Access

    Apparatus for Histological Validation of In Vivo and Ex Vivo Magnetic Resonance Imaging of the Human Prostate

    by Roger M. Bourne, Colleen Bailey, Edward William Johnston, Hayley Pye, Susan Heavey, Hayley Whitaker, Bernard Siow, Alex Freeman, Greg L. Shaw, Ashwin Sridhar, et al.

    This article describes apparatus to aid histological validation of magnetic resonance imaging studies of the human prostate. The apparatus includes a 3D-printed patient-specific mold that facilitates aligned in vivo and ex vivo imaging, in-situ tissue fixation, and tissue sectioning with minimal organ deformation. The mold and a dedicated container include MRI-visible landmarks to enable consistent tissue positioning and minimize image registration complexity. The inclusion of high spatial resolution ex vivo imaging aids in registration of in vivo MRI and histopathology data.


  • Open Access

    Microstructural models for diffusion MRI in breast cancer and surrounding stroma: an ex vivo study

    by Colleen Bailey, Bernard Siow, Eleftheria Panagiotaki, John H. Hipwell, Thomy Mertzanidou, Julie Owen, Patrycja Gazinska, Sarah E. Pinder, Daniel C. Alexander, David J. Hawkes

    The diffusion signal in breast tissue has primarily been modelled using apparent diffusion coefficient (ADC), intravoxel incoherent motion (IVIM) and diffusion tensor (DT) models, which may be too simplistic to describe the underlying tissue microstructure. Formalin‐fixed breast cancer samples were scanned using a wide range of gradient strengths, durations, separations and orientations. A variety of one‐ and two‐compartment models were tested to determine which best described the data. Models with restricted diffusion components and anisotropy were selected in most cancerous regions and there were no regions in which conventional ADC or DT models were selected. Maps of ADC generally related to cellularity on histology, but maps of parameters from more complex models suggest that both overall cell volume fraction and individual cell size can contribute to the diffusion signal, affecting the specificity of ADC to the tissue microstructure. The areas of coherence in diffusion anisotropy images were small, approximately 1 mm, but the orientation corresponded to stromal orientation patterns on histology.


  • Modelling Vascularity in Breast Cancer and Surrounding Stroma Using Diffusion MRI and Intravoxel Incoherent Motion

    by Colleen Bailey, Sarah Vinnicombe, Eleftheria Panagiotaki, Shelley A. Waugh, John H. Hipwell, Daniel C. Alexander, Kathryn Kitching, Patsy Whelehan, Sarah E. Pinder, Andrew Evans, et al.

  • Open Access

    Mapping water exchange rates in rat tumor xenografts using the late-stage uptake following bolus injections of contrast agent

    by Colleen Bailey, Firas Moosvi, Greg J. Stanisz

    Purpose To map the intra-to-extracellular water exchange rate constant in rat xenografts using a two-compartment model of relaxation with water exchange and a range of contrast agent concentrations and compare with histology. Methods MDA-MB-231 cells were xenografted into six nude rats. Three bolus injections of gadodiamide were administered. When uptake in the tumor demonstrated a steady-state, T1 data were acquired by spoiled gradient recalled acquisitions at four flip angles. A global fit of data to a two-compartment model incorporating exchange was performed, assuming a distribution volume of 20% of the rat. Results Voxels that did not reach steady-state and were excluded from parametric maps tended to be in large necrotic areas. TUNEL-negative (nonapoptotic) regions tended to have well-defined error bounds, with an average intra-to-extracellular exchange rate constant of 0.6 s−1. Apoptotic regions had higher exchange, but poorly determined upper bounds, with goodness of fit similar to that for a model assuming infinitely fast exchange. A lower bound of >3 s−1 was used to establish voxels where the exchange rate constant was fast despite a large upper bound. Conclusion Water exchange rates were higher in apoptotic regions, but examination of statistical errors was an important step in the mapping process. Magn Reson Med 71:1874–1887, 2014.


  • Contrasting the vascular response to sunitinib as measured by DCE-CT, DCE-MRI, and DCE-US.

    by John M. Hudson, Ross Williams, Colleen Bailey, Alex Kiss, Laurent M. Milot, Mostafa Atri, Greg J. Stanisz, Peter N. Burns, Georg A. Bjarnason

    378 Background: Medical imaging (DCE-MRI, DCE-CT, DCE-US) provides localized information about the integrity and hemodynamics of the tumor microvasculature. Methods: 34 treatment (Rx) naive pts with mRCC and an abdominal tumor suitable for imaging received Sunitinib 50 mg on a 4wk-on/2wk-off schedule. DCE-US, DCE-CT, and DCE-MRI were done at baseline, during the first course of Rx and after 2wks off Rx. Imaging parameters obtained included vessel permeability (Ktrans), extracellular volume fraction (ve) and Ktrans/ve=Kep (by DCE-MRI), permeability surface product (PS, by DCE-CT), blood volume (BV, by DCE-CT and DCE-US), and blood flow (by DCE-US). We also developed a morphology parameter (MP) that relates the flow kinetics of an intravascular microbubble contrast agent to tumor vascular morphology using DCE-US. Results: A range of imaging parameters that predicted for progression free survival (PFS) were identified in responding pts (N = 26). Baseline imaging parameters correlated with PFS: Ktrans by DCE-MR (r = 0.53, p = 0.01, N = 24), BV by DCE-CT (r = 0.48, p = 0.02, N = 25) and disorganized vessel morphology (large MP) by DCE-US (Spearman r = 0.-0.45, p = 0.02, N = 24). Changes from baseline imaging parameters correlated with PFS: BV by DCE-US at 2 wks (r = -0.46, p = 0.02, N = 24), Kep by DCE-MR at 2 wks (r = -0.45, p = 0.03, N = 24) and MP at 1wk (r = 0.67, p = 0.02, N = 12). There was a correlation between imaging methods: BV measured by DCE-CT correlated with BV by DCE-US (r = 0.46, p = 0.03, N = 23) and Kep by DCE-MR (r = 0.59, p = 0.003, N = 22); Permeability measured by DCE-MR (Ktrans) and DCE-CT (PS) correlated at 2wks (r = 0.56, p = 0.01, N = 21). Conclusions: This is the first study to contrast DCE-US, DCE-CT, and DCE-MRI imaging in pts receiving antiangiogenic therapy. Baseline parameters for all three methods can predict for PFS. Changes from baseline in DCE-US and DCE-MRI parameters also predict for PFS. There is a correlation between imaging methods in parameters that measure BV and permeability. A novel DCE-US parameter was developed (MP) that quantifies the degree of tumor vascular disorganization. Baseline values in MP and changes during Rx correlate with PFS. Clinical trial information: OCT1205, SU Timing RCC.


  • Open Access

    Quantitative magnetization transfer studies of apoptotic cell death

    by Colleen Bailey, Kimberly L. Desmond, Gregory J. Czarnota, Greg J. Stanisz

    Magnetization transfer measurements were performed on samples of acute myeloid leukemia cells at early (36 h postcisplatin treatment) and late (48 h posttreatment) stages of apoptosis. Magnetization transfer ratio was calculated and a two‐pool model was fitted to data at two powers and 16 offset frequencies of saturation pulse. No parameters changed significantly at early stages of apoptosis. At late stages, changes in magnetization transfer ratio were not significant, but quantitative model parameters showed a decrease in macromolecular proton fraction, M0B, and an increase in the T2 relaxation time of free water. Analysis also indicated an increase in the ratio R × M0B/R1A, where R is the exchange rate between free water and macromolecular protons and R1A is the T1 relaxation rate of free water. Changes in the magnetization transfer spectrum were largely attributable to differences in the free water pool and did not occur any earlier than changes in the average T1 relaxation time, T1obs. Magn Reson Med, 2011.