Mapping water exchange rates in rat tumor xenografts using the late-stage uptake following bolus injections of contrast agent
Open Access
- 25 June 2013
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (5) , 1874-1887
Abstract
Purpose To map the intra-to-extracellular water exchange rate constant in rat xenografts using a two-compartment model of relaxation with water exchange and a range of contrast agent concentrations and compare with histology. Methods MDA-MB-231 cells were xenografted into six nude rats. Three bolus injections of gadodiamide were administered. When uptake in the tumor demonstrated a steady-state, T1 data were acquired by spoiled gradient recalled acquisitions at four flip angles. A global fit of data to a two-compartment model incorporating exchange was performed, assuming a distribution volume of 20% of the rat. Results Voxels that did not reach steady-state and were excluded from parametric maps tended to be in large necrotic areas. TUNEL-negative (nonapoptotic) regions tended to have well-defined error bounds, with an average intra-to-extracellular exchange rate constant of 0.6 s−1. Apoptotic regions had higher exchange, but poorly determined upper bounds, with goodness of fit similar to that for a model assuming infinitely fast exchange. A lower bound of >3 s−1 was used to establish voxels where the exchange rate constant was fast despite a large upper bound. Conclusion Water exchange rates were higher in apoptotic regions, but examination of statistical errors was an important step in the mapping process. Magn Reson Med 71:1874–1887, 2014.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
This publication has 30 references indexed in Scilit:
- Tracer kinetic analysis of dynamic contrast‐enhanced MRI and CT bladder cancer data: A preliminary comparison to assess the magnitude of water exchange effectsMagnetic Resonance in Medicine, 2010
- Detection of apoptotic cell death in vitro in the presence of Gd‐DTPA‐BMAMagnetic Resonance in Medicine, 2009
- Cellular‐interstitial water exchange and its effect on the determination of contrast agent concentration in vivo: Dynamic contrast‐enhanced MRI of human internal obturator muscleMagnetic Resonance in Medicine, 2008
- Incorporating the effects of transcytolemmal water exchange in a reference region model for DCE‐MRI analysis: Theory, simulations, and experimental resultsMagnetic Resonance in Medicine, 2008
- Quantitative dynamic contrast-enhanced MRI in tumor-bearing rats and mice with inversion recovery TrueFISP and two contrast agents at 4.7 TJournal of Magnetic Resonance Imaging, 2006
- Simultaneous measurement of arterial input function and tumor pharmacokinetics in mice by dynamic contrast enhanced imaging: Effects of transcytolemmal water exchangeMagnetic Resonance in Medicine, 2004
- Water diffusion in a rat glioma during ganciclovir‐thymidine kinase gene therapy‐induced programmed cell death in vivo: Correlation with cell densityJournal of Magnetic Resonance Imaging, 2004
- Improving MR quantification of regional blood volume with intravascular T1 contrast agents: Accuracy, precision, and water exchangeMagnetic Resonance in Medicine, 1996
- Dynamic Gd‐DTPA enhanced MRI measurement of tissue cell volume fractionMagnetic Resonance in Medicine, 1995
- Water transport red blood cell membranesProgress in Biophysics and Molecular Biology, 1988