Joonho Jeon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joonho Jeon has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Yejin Ha
Division of Architectural and Fire Protection Engineering, Pukyong National University, 45 Yongso-ro Nam-gu, Busan 48513, Republic of Korea
9 shared publicationsSeonhyo Lee
Division of Architectural and Fire Protection Engineering, Pukyong National University, Busan, Korea
5 shared publicationsSungwook Park
5 shared publications- Sungwook Park
School of Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea
5 shared publications Sang Il Kwon
4 shared publicationsDaehwan Yu
Graduate Student, Division of Architectural and Fire Protection Engineering, Pukyong National University
3 shared publications
Latest Publications
- Open Access
- 30 April 2026
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 40 (2) , 1-9
Analysis of Light Extinction Characteristics as a Function of Particle Number and Size Distribution
In this study, the effects of the particle number and size distribution on light extinction were analyzed on the basis of experiments and scattering theory. Monodisperse spherical polystyrene latex particles with diameters of 269, 350, and 500 nm were used, and the experimental conditions were set to maintain a constant total sprayed mass. During the experiments, light extinction and particle size distribution were measured. The results showed that under the same mass conditions, the total particle number increased as the particle size decreased, leading to enhanced light extinction. Using the measured particle number and size distribution, the mass-specific light extinction was estimated using the Mie scattering theory, and the estimated and measured light extinction values were compared. This comparison suggested that the single-particle scattering theory may not fully explain light extinction under high-particle-number-concentration conditions. Based on this comparison, an empirical correction factor for light extinction was derived to correct the errors in the single-particle scattering theory under high-particle-number-concentration conditions.
- 30 April 2026
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 40 (2) , 1-9
Open AccessAnalysis of Light Extinction Characteristics as a Function of Particle Number and Size Distribution
In this study, the effects of the particle number and size distribution on light extinction were analyzed on the basis of experiments and scattering theory. Monodisperse spherical polystyrene latex particles with diameters of 269, 350, and 500 nm were used, and the experimental conditions were set to maintain a constant total sprayed mass. During the experiments, light extinction and particle size distribution were measured. The results showed that under the same mass conditions, the total particle number increased as the particle size decreased, leading to enhanced light extinction. Using the measured particle number and size distribution, the mass-specific light extinction was estimated using the Mie scattering theory, and the estimated and measured light extinction values were compared. This comparison suggested that the single-particle scattering theory may not fully explain light extinction under high-particle-number-concentration conditions. Based on this comparison, an empirical correction factor for light extinction was derived to correct the errors in the single-particle scattering theory under high-particle-number-concentration conditions.
- Open Access
- 31 March 2026
- Published by Korea Institute of Fire Science and Engineering in International Journal of Fire Science and Engineering
- Vol. 40 (1) , 16-23
Study on Smoke Optical Characteristics Under Static and Dynamic Smoke-Generation Conditions
Smoke produced during a fire causes optical extinction through light scattering and absorption, reducing visibility. The optical properties of smoke can vary depending on the smoke generation environment, such as accumulation and exhaust flow conditions. Quantitative evaluation of optical properties under different conditions is necessary to ensure reliable visibility prediction. In this study, changes in the extinction coefficient were compared to analyze the effects of smoke generation environments on the optical properties of smoke. Two representative small-scale experimental apparatuses were used: an ISO 5659-2-based smoke density chamber under static conditions and an ISO/TS 5660-4-based cone calorimeter under dynamic conditions. Under static conditions, optical extinction caused by smoke accumulation continued even after the extinction coefficient reached its maximum value. In contrast, under dynamic conditions, the extinction coefficient showed two peak values during combustion progression. These results suggest that evaluating fire hazards using only optical properties derived under dynamic conditions may introduce uncertainty.
- 31 March 2026
- Published by Korea Institute of Fire Science and Engineering in International Journal of Fire Science and Engineering
- Vol. 40 (1) , 16-23
Open AccessStudy on Smoke Optical Characteristics Under Static and Dynamic Smoke-Generation Conditions
Smoke produced during a fire causes optical extinction through light scattering and absorption, reducing visibility. The optical properties of smoke can vary depending on the smoke generation environment, such as accumulation and exhaust flow conditions. Quantitative evaluation of optical properties under different conditions is necessary to ensure reliable visibility prediction. In this study, changes in the extinction coefficient were compared to analyze the effects of smoke generation environments on the optical properties of smoke. Two representative small-scale experimental apparatuses were used: an ISO 5659-2-based smoke density chamber under static conditions and an ISO/TS 5660-4-based cone calorimeter under dynamic conditions. Under static conditions, optical extinction caused by smoke accumulation continued even after the extinction coefficient reached its maximum value. In contrast, under dynamic conditions, the extinction coefficient showed two peak values during combustion progression. These results suggest that evaluating fire hazards using only optical properties derived under dynamic conditions may introduce uncertainty.
- Open Access
- 30 June 2025
- Published by Korea Institute of Fire Science and Engineering in International Journal of Fire Science and Engineering
- Vol. 39 (2) , 1-9
Comparative Study on Validation of Multi-Step Chemical Reaction Model in Fire Simulation
Fire involves a number of chemical reactions, but most fire simulations do not consider multi-step chemical processes. Using multi-step chemical reactions enalbles more realistic fire simulation. In this study, ANSYS FLUENT® used to simulate pool fire with multi- step chemical reactions. It is possible to predict various species concentrations involved in the fire process, not only thermal properties. In this study, the fire is modeled using two different computational fluid dynamics software ANSYS FLUENT® and Fire Dynamic Simulator (FDS). The validity of the ANSYS FLUENT® fire simulation is assessed by comparing temperature and species concentration results with experimental and FDS results. Unlike FDS fire simulation, ANSYS FLUENT® fire simulation with multi-step chemical reactions is able to analyze intermediate species concentration compared with the experimental results. Furthermore, ANSYS FLUENT® fire simulation can measure various species involved in fire, so it is expected to predict various aspects of fire.
- 30 June 2025
- Published by Korea Institute of Fire Science and Engineering in International Journal of Fire Science and Engineering
- Vol. 39 (2) , 1-9
Open AccessComparative Study on Validation of Multi-Step Chemical Reaction Model in Fire Simulation
Fire involves a number of chemical reactions, but most fire simulations do not consider multi-step chemical processes. Using multi-step chemical reactions enalbles more realistic fire simulation. In this study, ANSYS FLUENT® used to simulate pool fire with multi- step chemical reactions. It is possible to predict various species concentrations involved in the fire process, not only thermal properties. In this study, the fire is modeled using two different computational fluid dynamics software ANSYS FLUENT® and Fire Dynamic Simulator (FDS). The validity of the ANSYS FLUENT® fire simulation is assessed by comparing temperature and species concentration results with experimental and FDS results. Unlike FDS fire simulation, ANSYS FLUENT® fire simulation with multi-step chemical reactions is able to analyze intermediate species concentration compared with the experimental results. Furthermore, ANSYS FLUENT® fire simulation can measure various species involved in fire, so it is expected to predict various aspects of fire.
- Open Access
- 14 May 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 72
Large eddy simulations of pool fires and backdraft in a compartment using FDS and FireFOAM
- 14 May 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 72
Open AccessLarge eddy simulations of pool fires and backdraft in a compartment using FDS and FireFOAM
- Open Access
- 30 April 2025
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 39 (2) , 18-27
Numerical Study on the Wall Heat Transfer during the Horizontal and Vertical Elongated Compartment Fire
In this study, numerical simulations were performed using a Fire Dynamics Simulator to examine the variation in heat transfer to wall surfaces during horizontal and vertical fires with elongated compartments. Fire scenarios were established based on the compartment geometries and the presence of openings. The sizes of the compartments and openings were modeled in accordance with relevant legal standards. The simulation results were analyzed for radiative and convective heat fluxes to the wall surfaces in horizontal and vertical fires with elongated compartments. In the horizontal compartment, both the radiative and convective heat fluxes to the wall showed similar results, regardless of the opening conditions. In the vertical compartment, the wall heat flux increased when the openings were closed and exhibited a distinct difference depending on the opening conditions. In addition, the radiative heat flux became more dominant when the opening was closed, whereas the convective heat flux became more dominant when it was open. In addition, the convective heat transfer coefficient, which depends on various factors, was compared with the temperature and velocity results within the compartments.
- 30 April 2025
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 39 (2) , 18-27
Open AccessNumerical Study on the Wall Heat Transfer during the Horizontal and Vertical Elongated Compartment Fire
In this study, numerical simulations were performed using a Fire Dynamics Simulator to examine the variation in heat transfer to wall surfaces during horizontal and vertical fires with elongated compartments. Fire scenarios were established based on the compartment geometries and the presence of openings. The sizes of the compartments and openings were modeled in accordance with relevant legal standards. The simulation results were analyzed for radiative and convective heat fluxes to the wall surfaces in horizontal and vertical fires with elongated compartments. In the horizontal compartment, both the radiative and convective heat fluxes to the wall showed similar results, regardless of the opening conditions. In the vertical compartment, the wall heat flux increased when the openings were closed and exhibited a distinct difference depending on the opening conditions. In addition, the radiative heat flux became more dominant when the opening was closed, whereas the convective heat flux became more dominant when it was open. In addition, the convective heat transfer coefficient, which depends on various factors, was compared with the temperature and velocity results within the compartments.
- 23 March 2025
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 214
Smoldering fire potential in activated carbons based on surface temperature and carbon monoxide emission
- 23 March 2025
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 214
Smoldering fire potential in activated carbons based on surface temperature and carbon monoxide emission
- Open Access
- 28 February 2025
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 39 (1) , 9-21
Particle-Size Distribution and Light-Extinction Characteristics of Smoke Generated from Plastics (PMMA, PC) under Radiative Heat Flux
Large amounts of smoke generated during combustion processes reduce the visible distance, thereby hindering evacuation operations, if necessitated. The mechanism by which smoke interacts with light depends on the composition and size of the particles constituting the smoke. To ensure evacuation safety, analyzing the main components of smoke and particle sizes that affect light extinction is crucial. In this experimental study, the specific optical density and particle size distribution of smoke with radiant heat flux from an ISO 5659-2 smoke density chamber for Polymethyl methacrylate (PMMA) and Polycarbonate (PC) were measured using a scanning mobility particle sizer (SMPS). Raman analysis was performed to investigate the main components of the smoke particles. During the flame combustion process, the light extinction of 700- to 1000-nm particles reached its maximum, and the specific optical density increased rapidly. However, in decomposition combustion, the size of the particles, at which light extinction reached its maximum gradually increased depending on the intensity of radiant heat and exposure time.
- 28 February 2025
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 39 (1) , 9-21
Open AccessParticle-Size Distribution and Light-Extinction Characteristics of Smoke Generated from Plastics (PMMA, PC) under Radiative Heat Flux
Large amounts of smoke generated during combustion processes reduce the visible distance, thereby hindering evacuation operations, if necessitated. The mechanism by which smoke interacts with light depends on the composition and size of the particles constituting the smoke. To ensure evacuation safety, analyzing the main components of smoke and particle sizes that affect light extinction is crucial. In this experimental study, the specific optical density and particle size distribution of smoke with radiant heat flux from an ISO 5659-2 smoke density chamber for Polymethyl methacrylate (PMMA) and Polycarbonate (PC) were measured using a scanning mobility particle sizer (SMPS). Raman analysis was performed to investigate the main components of the smoke particles. During the flame combustion process, the light extinction of 700- to 1000-nm particles reached its maximum, and the specific optical density increased rapidly. However, in decomposition combustion, the size of the particles, at which light extinction reached its maximum gradually increased depending on the intensity of radiant heat and exposure time.
- Open Access
Risk Assessment of Toxic Gas Dispersion from Electric Vehicle Fires in Underground Apartment Parking Garages Using Numerical Analysis
With the rising adoption of electric vehicles (EVs), fire-related issues have garnered significant attention, prompting extensive research efforts. This study investigates the dispersion of toxic gases generated during EV fires in confined spaces, such as underground parking garages, to enhance fire safety protocols. Using the fire dynamics simulator (FDS), simulations were conducted for 24 kWh, 53 kWh, and 99.8 kWh battery scenarios to assess the impact of increasing battery capacities on toxic gas emissions. The results indicate that hydrogen fluoride (HF) concentrations in poorly ventilated areas peaked at 488.2 ppm, significantly exceeding the Acute Exposure Guideline Level (AEGL-2) threshold of 12 ppm. The exposure time exceeding AEGL-2 (30 min) was recorded as 53 min and 49 s for the 99.8 kWh scenario, highlighting a substantial risk to occupants and emergency responders. Additionally, the fractional effective dose (FED) for asphyxiant gases and the fractional effective concentration (FEC) for irritant gases were analyzed, revealing that larger battery capacities and proximity to the fire source reduced tenability time by up to 47% compared to smaller batteries. These findings provide critical insights into fire safety measures, emphasizing the necessity of early fire detection systems, enhanced ventilation strategies, and battery-specific fire suppression technologies in confined environments.
Open AccessRisk Assessment of Toxic Gas Dispersion from Electric Vehicle Fires in Underground Apartment Parking Garages Using Numerical Analysis
With the rising adoption of electric vehicles (EVs), fire-related issues have garnered significant attention, prompting extensive research efforts. This study investigates the dispersion of toxic gases generated during EV fires in confined spaces, such as underground parking garages, to enhance fire safety protocols. Using the fire dynamics simulator (FDS), simulations were conducted for 24 kWh, 53 kWh, and 99.8 kWh battery scenarios to assess the impact of increasing battery capacities on toxic gas emissions. The results indicate that hydrogen fluoride (HF) concentrations in poorly ventilated areas peaked at 488.2 ppm, significantly exceeding the Acute Exposure Guideline Level (AEGL-2) threshold of 12 ppm. The exposure time exceeding AEGL-2 (30 min) was recorded as 53 min and 49 s for the 99.8 kWh scenario, highlighting a substantial risk to occupants and emergency responders. Additionally, the fractional effective dose (FED) for asphyxiant gases and the fractional effective concentration (FEC) for irritant gases were analyzed, revealing that larger battery capacities and proximity to the fire source reduced tenability time by up to 47% compared to smaller batteries. These findings provide critical insights into fire safety measures, emphasizing the necessity of early fire detection systems, enhanced ventilation strategies, and battery-specific fire suppression technologies in confined environments.
- Open Access
- 31 August 2024
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 38 (4) , 1-9
Characteristics of Polyurethane Foam Smoke Particles Formed during Initial Fire Stages
When exposed to an external heat source, a solid fuel generates condensed and gaseous phases on its surface through pyrolysis. The pyrolysis products can determine ignition and fire development, as well as smoke release. Elucidating the pyrolysis process is essential for predicting complex fire phenomena such as flame propagation and spread. In this study, thermogravimetric analysis (TGA) and an optical particle counter (OPC) were used to investigate smoke particle formation based on pyrolysis. The TGA results revealed that polyurethane foam pyrolyzed in two stages and then oxidized in three stages. The OPC results confirmed that smoke particle formation depended on the presence of an ignition source at low temperatures. Additionally, methods are provided to account for the behavior of particulate matter during pyrolysis modeling.
- 31 August 2024
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 38 (4) , 1-9
Open AccessCharacteristics of Polyurethane Foam Smoke Particles Formed during Initial Fire Stages
When exposed to an external heat source, a solid fuel generates condensed and gaseous phases on its surface through pyrolysis. The pyrolysis products can determine ignition and fire development, as well as smoke release. Elucidating the pyrolysis process is essential for predicting complex fire phenomena such as flame propagation and spread. In this study, thermogravimetric analysis (TGA) and an optical particle counter (OPC) were used to investigate smoke particle formation based on pyrolysis. The TGA results revealed that polyurethane foam pyrolyzed in two stages and then oxidized in three stages. The OPC results confirmed that smoke particle formation depended on the presence of an ignition source at low temperatures. Additionally, methods are provided to account for the behavior of particulate matter during pyrolysis modeling.