SLSimona Lombardo

Simona Lombardo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Simona Lombardo has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optical Designs with Curved Detectors for Fiber Bragg Grating Interrogation Monitors

    by Eduard Muslimov, Nadezhda Pavlycheva, Emmanuel Hugot, Simona Lombardo, Ilnur Nureev, Oleg Morozov

    In this paper, we evaluate the application of curved detectors and freeform optics technologies for fiber Bragg gratings (FBGs) interrogation monitors design. It is shown that, in a high-dispersion spectrograph scheme, the camera part operates in special conditions, which result in a field curvature change. This field curvature can be compensated by the use of a curved detector. When used together with freeform optics, the curved detectors allow for reduction of the number of optical components to two or even one element by merging their functions. Three design examples for the range of 810–860 nm reaching the spectral resolution limit of 89–139 pm at NA=0.14 are presented to demonstrate the achieved performance and the technological trade-offs.


  • Precision requirements for the POLLUX-LUVOIR spectropolarimeter

    by Eduard R. Muslimov, Jean-Claude Bouret, Coralie Neiner, Marc Ferrari, Simona Lombardo, Arturo Lopez Ariste, Maëlle Le Gal

    SPIE Digital Library Proceedings


  • Off-axis parabolas super polished under stress: the case of the Roman Space Telescope coronagraphic instrument mirrors

    by Melanie Roulet, Emmanuel Hugot, Carolyn Atkins, Michel Marcos, Simona Lombardo, Anne Bonnefoi, Amandine Caillat, Marc Ferrari

    Direct imaging of exoplanets requires high contrast imaging techniques that demand tight tolerances on the optical surface error. The Nancy Grace Roman Space Telescope (RST) (previously named WFIRST) aims to perform direct imaging of SuperEarth-like exoplanets through its active coronographic instrument (CGI). Eight off-axis parabola (OAP) mirrors are utilised within the CGI to create a compact instrument and to ensure access to the pupil and focal planes. The surface form error and surface roughness of these relay optics directly impact the quality of the dark hole, and therfore the observable location for exoplanets. A new fabrication process for OAP manufacture via stressed mirror polishing (SMP) is presented in this paper. First, the design of the mirror substrate is investigated to create an innovative thickness distribution capable of producing the OAP geometry with a simple warping harness composed by two micrometer screws. Second, the novel design is implemented on a 60 mm diameter OAP prototype in Zerodur; a description of the fabrication process chain and the characterisation of the optical surface over all spatial frequencies are presented. Results from this first prototype demonstrated that the surface form error deviates from < 1 nm root means square (RMS) from the simulations and with a surface roughness of 2.1 Å Ra.


  • The SNEMO and SUGAR Companion Data Sets

    by G. Aldering, P. Antilogus, C. Aragon, S. Bailey, C. Baltay, S. Bongard, K. Boone, C. Buton, N. Chotard, Y. Copin, et al.

    The Nearby Supernova Factory presents an interim data release of spectrophotometric timeseries of 210 SNe Ia. Two slightly different versions of the data are included, corresponding to the training data sets used for the SNEMO and SUGAR Type Ia models. The data has been shifted to the restframe and is blinded with respect to cosmology.


  • Next-generation telescopes with curved focal surface for ultralow surface brightness surveys

    by Simona Lombardo, Eduard Muslimov, Gerard Lemaître, Emmanuel Hugot

    In spite of major advances in both ground- and space-based instrumentation, the ultralow surface brightness Universe (ULSB) still remains a largely unexplored volume in observational parameter space. ULSB observations provide unique constraints on a wide variety of objects, from the Zodiacal light all the way to the optical cosmological background radiation, through dust cirri, mass-loss shells in giant stars, LSB galaxies and the intracluster light. These surface brightness levels (>28–29 mag arcsec−2) are observed by maximizing the efficiency of the surveys and minimizing or removing the systematics arising in the measurement of surface brightness. Based on full-system photon Monte Carlo simulations, we present here the performance of a ground-based telescope aimed at carrying out ULSB observations, with a curved focal surface design. Its off-axis optical design maximizes the field of view while minimizing the focal ratio. No lenses are used, as their multiple internal scatterings increase the wings of the point spread function (PSF), and the usual requirement of a flat focal plane is relaxed through the use of curved CCD detectors. The telescope has only one unavoidable single refractive surface, the cryostat window, and yet it delivers a PSF with ultracompact wings, which allows the detection, for a given exposure time, of surface brightness levels nearly three orders of magnitude fainter than any other current telescope.


  • Open Access

    Next-generation telescopes with curved focal surface for ultra-low surface brightness surveys

    by Simona Lombardo, Eduard Muslimov, Gerard Lemaître, Emmanuel Hugot

    In spite of major advances in both ground- and space-based instrumentation, the ultra-low-surface brightness universe (ULSB) still remains a largely unexplored volume in observational parameter space. ULSB observations provide unique constraints on a wide variety of objects, from the Zodiacal light all the way to the optical cosmological background radiation, through dust cirri, mass loss shells in giant stars, LSB galaxies and the intracluster light. These surface brightness levels (>28-29 mag arcsec^-2) are observed by maximising the efficiency of the surveys and minimising or removing the systematics arising in the measurement of surface brightness. Based on full-system photon Monte Carlo simulations, we present here the performance of a ground-based telescope aimed at carrying out ULSB observations, with a curved focal surface design. Its off-axis optical design maximises the field of view while minimising the focal ratio. No lenses are used, as their multiple internal scatterings increase the wings of the point spread function (PSF), and the usual requirement of a flat focal plane is relaxed through the use of curved CCD detectors. The telescope has only one unavoidable single refractive surface, the cryostat window, and yet it delivers a PSF with ultra-compact wings, which allows the detection, for a given exposure time, of surface brightness levels nearly three orders of magnitude fainter than any other current telescope.

  • Curved detectors for astronomical applications: characterization results on different samples

    by Simona Lombardo, Thibault Behaghel, Bertrand Chambion, Stéphane Caplet, Wilfried Jahn, Emmanuel Hugot, Eduard Muslimov, Melanie Roulet, Marc Ferrari, Christophe Gaschet, et al.

    Due to the increasing dimension, complexity, and cost of future astronomical surveys, new technologies enabling more compact and simpler systems are required. The development of curved detectors allows enhancement of the performances of the optical system used (telescope or astronomical instrument), while keeping the system more compact. We describe here a set of five curved complementary metal-oxide semiconductor (CMOS) detectors developed within a collaboration between CEA-LETI and CNRS-LAM. These fully functional detectors 20 Mpix (CMOSIS CMV20000) have been curved to different radii of curvature and spherical shapes (both convex and concave) over a size of 24×32  mm2. Before being able to use them for astronomical observations, we assess the impact of the curving process on their performances. We perform a full electro-optical characterization of the curved detectors, by measuring the gain, the full well capacity, the dynamic range, and the noise properties, such as dark current, readout noise, pixel-relative non-uniformity. We repeat the same process for the flat version of the same CMOS sensor, as a reference for comparison. We find no significant difference among most of the characterization values of the curved and flat samples. We obtain values of readout noise of 10e− for the curved samples compared to the 11e− of the flat sample, which provides slightly larger dynamic ranges for the curved detectors. Additionally, we measure consistently smaller values of dark current compared to the flat CMOS sensor. The curving process for the prototypes shown in this paper does not significantly impact the performances of the detectors. These results represent the first step toward their astronomical implementation.


  • Open Access

    Design of optical systems with toroidal curved detectors

    by Eduard Muslimov, Emmanuel Hugot, Marc Ferrari, Thibault Behaghel, Gerard R. Lemaitre, Melanie Roulet, Simona Lombardo

    We consider using toroidal curved detectors to improve the performance of imaging optical systems. We demonstrate that some optical systems have an anamorphic field curvature. We consider an unobscured reimaging three-mirror anastigmat as an example (f′=960 mm, F/5.3, ωx×ωy=4°×4°). By assuming that the image is focused on a toroidal detector surface and performing reoptimization, it becomes possible to obtain a notable gain in the image quality—up to 40% in terms of the spot root mean square radius. Through analytic computations and finite-element analysis, we demonstrate that this toroidal shape can be obtained by bending of a thinned detector in a relatively simple setup.