Yuval Cohen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuval Cohen has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ferruccio Renzoni
Department of Physics and Astronomy, University College London, London, U.K.
5 shared publications - Benjamin Maddox
Department of Physics, Durham University, Durham, United Kingdom
4 shared publications - Cameron Deans
Department of Physics and Astronomy, University College London , Gower Street, London WC1E 6BT, United Kingdom
3 shared publications - Han Yao
School of Physics, Nanjing University of Science and Technology, Nanjing, China
2 shared publications - Luca Marmugi
Department of Physics and Astronomy, University College London , Gower Street, London WC1E 6BT, United Kingdom
2 shared publications Antonio Vigilante
Department of Physics and Astronomy, University College London , Gower Street, London WC1E 6BT, United Kingdom
1 shared publication
Latest Publications
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-5
Rapid Electromagnetic Induction Imaging With an Optically Raster-Scanned Atomic Magnetometer
We present an apparatus to overcome the limitations of mechanical raster-scanning in electromagnetic induction imaging (EMI) techniques by instead performing a 2D optical raster-scan within the vapour cell of a radio-frequency atomic magnetometer (RF-AM). A large cuboidal 87 Rb vapour cell is employed to act as the medium of an RF-AM with the pump and probe beams translated in the cell via acousto-optics. The technique is shown to give robust and repeatable magnetic measurements over the cell volume and successfully resolves conductive targets with EMI. Optical raster-scanning removes the limitation of slow mechanical actuation and a fast imaging procedure is enacted resolving conductive targets at a rate of 40 ms/pixel.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-5
Rapid Electromagnetic Induction Imaging With an Optically Raster-Scanned Atomic Magnetometer
We present an apparatus to overcome the limitations of mechanical raster-scanning in electromagnetic induction imaging (EMI) techniques by instead performing a 2D optical raster-scan within the vapour cell of a radio-frequency atomic magnetometer (RF-AM). A large cuboidal 87 Rb vapour cell is employed to act as the medium of an RF-AM with the pump and probe beams translated in the cell via acousto-optics. The technique is shown to give robust and repeatable magnetic measurements over the cell volume and successfully resolves conductive targets with EMI. Optical raster-scanning removes the limitation of slow mechanical actuation and a fast imaging procedure is enacted resolving conductive targets at a rate of 40 ms/pixel.
- Open Access
- 18 April 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (16) , 164002
A radio-frequency Bose–Einstein condensate magnetometer
We report on a radio frequency magnetometer employing a Bose–Einstein condensate of 87Rb atoms held in a dipole trap. An AC sensitivity of is achieved at a probing volume of , leading to a volume-normalized sensitivity of . At larger probing volumes with the atoms released from the magnetic trap used in the initial phase of the evaporation sequence, the AC sensitivity is improved to , allowing a two-mode approach for applications requiring improved sensitivity. Immediate application in high-resolution electromagnetic induction imaging is expected when compared to performance of other induction-based imaging platforms.- 18 April 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (16) , 164002
Open AccessA radio-frequency Bose–Einstein condensate magnetometer
We report on a radio frequency magnetometer employing a Bose–Einstein condensate of 87Rb atoms held in a dipole trap. An AC sensitivity of is achieved at a probing volume of , leading to a volume-normalized sensitivity of . At larger probing volumes with the atoms released from the magnetic trap used in the initial phase of the evaporation sequence, the AC sensitivity is improved to , allowing a two-mode approach for applications requiring improved sensitivity. Immediate application in high-resolution electromagnetic induction imaging is expected when compared to performance of other induction-based imaging platforms. - Open Access
- 3 January 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (1) , 014002
Through-skin pilot-hole detection and localization with a mechanically translatable atomic magnetometer
We demonstrate through-skin electromagnetic induction imaging of pilot-holes in an aluminum block concealed by a 0.41 mm thick aluminum shield with a 1.49 kg mechanically translatable radio frequency atomic magnetometer. The pilot-holes are identified and localized with submillimeter accuracy both with and without the Al shield. We utilize a dual-frequency technique to isolate the image of the target while removing the effect of the shielding from the image. Imaging accuracy is shown to be robust in a range of different operating conditions and immune to the effect of a thermal insulator between the shielding and the target. The approach introduced here finds direct application in aircraft wing manufacture and is competitive with existing approaches.
- 3 January 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (1) , 014002
Open AccessThrough-skin pilot-hole detection and localization with a mechanically translatable atomic magnetometer
We demonstrate through-skin electromagnetic induction imaging of pilot-holes in an aluminum block concealed by a 0.41 mm thick aluminum shield with a 1.49 kg mechanically translatable radio frequency atomic magnetometer. The pilot-holes are identified and localized with submillimeter accuracy both with and without the Al shield. We utilize a dual-frequency technique to isolate the image of the target while removing the effect of the shielding from the image. Imaging accuracy is shown to be robust in a range of different operating conditions and immune to the effect of a thermal insulator between the shielding and the target. The approach introduced here finds direct application in aircraft wing manufacture and is competitive with existing approaches.
- Open Access
- 5 July 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (1) , 014001
Electromagnetic induction imaging with a scanning radio frequency atomic magnetometer
We demonstrate electromagnetic induction imaging with an unshielded, portable radio frequency atomic magnetometer scanning over the target object. This configuration satisfies standard requirements in typical applications, from security screening to medical imaging. The ability to scan the magnetometer over the object relies on the miniaturization of the sensor head, the active compensation of the ambient magnetic field, and the implementation of a dedicated procedure to extract high-quality images from the recorded spatial dependent magnetic resonance. The procedure is shown to be effective in suppressing the detrimental effects of the spatial variation of the magnetic environment.
- 5 July 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (1) , 014001
Open AccessElectromagnetic induction imaging with a scanning radio frequency atomic magnetometer
We demonstrate electromagnetic induction imaging with an unshielded, portable radio frequency atomic magnetometer scanning over the target object. This configuration satisfies standard requirements in typical applications, from security screening to medical imaging. The ability to scan the magnetometer over the object relies on the miniaturization of the sensor head, the active compensation of the ambient magnetic field, and the implementation of a dedicated procedure to extract high-quality images from the recorded spatial dependent magnetic resonance. The procedure is shown to be effective in suppressing the detrimental effects of the spatial variation of the magnetic environment.
- 18 February 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 114 (7) , 073505
A cold atom radio-frequency magnetometer
We propose and demonstrate a radio-frequency atomic magnetometer with sub-Doppler laser cooled rubidium-87. With a simple and compact design, our system demonstrates a sensitivity of in an unshielded environment, thus matching or surpassing previously reported cold atom designs. By merging the multiple uses and the robustness of radio-frequency atomic magnetometers with the detailed control of laser cooling, our cold atom radio-frequency magnetometer has potential for moving applications of atomic magnetometry to high spatial resolutions. A direct impact in metrology for applied sciences, materials characterization, and nanotechnology can be anticipated.- 18 February 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 114 (7) , 073505
A cold atom radio-frequency magnetometer
We propose and demonstrate a radio-frequency atomic magnetometer with sub-Doppler laser cooled rubidium-87. With a simple and compact design, our system demonstrates a sensitivity of in an unshielded environment, thus matching or surpassing previously reported cold atom designs. By merging the multiple uses and the robustness of radio-frequency atomic magnetometers with the detailed control of laser cooling, our cold atom radio-frequency magnetometer has potential for moving applications of atomic magnetometry to high spatial resolutions. A direct impact in metrology for applied sciences, materials characterization, and nanotechnology can be anticipated.