Andrew Graham Swanson has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Harmonic Distortion and Distribution Transformer Thermal Risk in Low-Voltage Networks: Feeder Impedance Sensitivity for Sustainable Renewable Energy Integration

    by Francis Bennie, Mohamed Khan, Andrew Swanson

    The increasing penetration of distributed energy resources (DERs) in low-voltage networks is central to the clean energy transition but introduces coupled challenges in voltage regulation, harmonic distortion, and distribution-transformer operation that impact grid sustainability and asset longevity. This paper isolates feeder impedance as a controlled variable and evaluates whether remote-network power-quality severity and transformer consequence follow the same sensitivity trend. A time-domain model used a factory-matched 200 kVA, 11 kV/420 V Dyn11 transformer with 40% DER connected at remote Node S3. The DER current contained prescribed fifth, seventh, eleventh, and thirteenth harmonics, while the LV feeder resistance and inductance were co-scaled from 0.5 to 2.0 pu. Across the DER-connected sweep, Node S3 line-to-line RMS voltage increased from 420.45 V to 428.95 V, and the voltage-rise magnitude increased from 3.03 V to 11.55 V. Selected-order Node S3 VTHD increased monotonically from 1.104% to 1.395%. Baseline-corrected harmonic transfer impedance also increased at every assessed harmonic, supporting a feeder-impedance-driven voltage-response mechanism. In contrast, transformer loading remained within 14.44–14.52%, total transformer loss within 350.26–350.93 W, hot-spot temperature within 38.229–38.246 °C, and common-baseline relative aging within 0.2863–0.2871. The results demonstrate that feeder weakness can materially increase remote-node voltage and harmonic sensitivity without producing a corresponding increase in transformer thermal severity. Network voltage response and transformer consequence should therefore be assessed as related but non-equivalent engineering domains. By separating power quality management from transformer thermal risk, distribution utilities can avoid premature asset replacement, enabling targeted, resource-efficient investments that support sustainable grid planning and long-term renewable integration (SDG 7 and SDG 9).

  • Open Access

    Experimental Validation of a Physical Transmission Line Model and Quasi-Dynamic Simulation for PV Grid Flexibility Studies

    by Peter Munyao Mutuku, Alan Leigh Lawrence Jarvis, Andrew Graham Swanson, Mohamed Fayaz Khan

    Accurate transmission line representation is essential for reliable hardware validation and quasi-dynamic assessment of powersystem flexibility under high PV penetration. This study experimentally validates a physical Lucas-Nülle 300 km three-phase transmission line model and subsequently applies its equivalent electrical parameters in quasi-dynamic power-flow simulations. Three software representations (lumped-series, nominal-π and distributed-parameter models) are evaluated against the physical benchmark under resistive and inductive loading. The lumped-series provides the closest agreement, with an average receiving-end voltage error of 2.0 V, whereas nominal-π overestimate voltage by 4.7V to 6.7 V. Distributed parameter model exhibit larger deviations, with an average error of 14.2 V. These results establish the lumped-series as the most suitable electrical representation of the physical benchmark for subsequent software model application. The physical model is then represented in DIgSILENT PowerFactory as both 300 km transmission line and a three-bus ring network. The Newton–Raphson method is used to solve the quasi-dynamic power flow, with solar PV generation and data-center load profiles incorporated as time-varying inputs. The normal load profile results reveal substantial temporal grid-power variations, with maximum external grid supply of 22.35MW and 37.70MW absorption and peak net load ramp of 4.55MW/5min. The corresponding energy shifting requirement is 162.4 MWh. For the data-center load, the minimum design requirements include a ramp rate of 9.71MW/5min, power rating of 18.07MW and balancing energy of 96.63 MWh. The results establish a systematicpathway from experimental transmission line validation to system-level quasi-dynamic simulation for quantifying flexibility in solar PV power systems and supporting future hardware-in-the-loop studies.

  • Open Access

    Solar PV tilt-azimuth optimization using OSM-MEPS and PVLIB: Statistical analysis, techno-economic assessment and ramp-rate modeling

    by Peter Munyao Mutuku, Alan Lawrence Leigh Jarvis, Andrew Graham Swanson, Mohamed Fayaz Khan

  • Open Access

    Forecast-Driven Virtual Power Plant Dispatch for Hybrid Renewable Energy Systems: Reducing Grid Dependency Using LSTM Models

    by Omaira Jajbhay, Mohamed F. Khan, Andrew G. Swanson

    This study presents a forecast-driven Advanced Forecasting Model (AFM) and Virtual Power Plant (VPP) framework for a hybrid renewable energy system comprising utility-scale solar PV, wind generation, and a Battery Energy Storage System. Long Short-Term Memory neural networks provide real-time short-term forecasts to dynamically schedule power flows based on battery state-of-charge, grid import limits, and system constraints. Solar irradiance forecasting achieved MAE = 10.674 W/m2, RMSE = 16.348 W/m2, and MAPE = 14.18%, while wind speed forecasting achieved MAE = 0.880 m/s, RMSE = 1.115 m/s, and MAPE = 22.01%. Two dispatch scenarios were evaluated over a 72 h window: a reactive baseline and the proposed AFM/VPP strategy. The AFM reduced total grid imports by 57.48% (1466.34 MWh to 623.47 MWh), increased renewable utilization, and minimized curtailment. Financial analysis indicates an accelerated break-even (Year 6 vs. Year 9), a higher net present value, and cumulative 20-year profits exceeding R26.01 billion despite marginally higher capital expenditure. Emissions analysis shows annual CO2 reductions from 123,680 t to 61,841 t, yielding 1.236 million tons of avoided emissions over 20 years. These results confirm that forecast-driven dispatch enhances operational efficiency, economic performance, and environmental sustainability, establishing a scalable approach for VPP operation in renewable-rich energy systems.

  • Open Access

    Assessment of Harmonic Distortion Compliance in South African Distribution Networks Under Increasing Penetration of Distributed Energy Resources

    by Francis Bennie, Mohamed Khan, Andrew Swanson

    The increasing penetration of inverter-based distributed energy resources (DERs) within distribution networks has resulted in harmonic distortion risks that can affect transformer thermal loading, service life, and network hosting capacity. This study assesses harmonic behaviour under increasing DER penetration using a detailed MATLAB 2025b/Simulink model of the CIGRÉ low-voltage benchmark feeder, adapted to reflect representative network parameters and run at a 400 V point of common coupling (PCC). DER penetration is incrementally increased from 0% to 195% of feeder load, and for each penetration level the PCC currents and voltages are examined using FFT-based spectrum extraction. The short-circuit strength is first calculated (I_SC/I_L = 14.1), and harmonic current and voltage distortion thresholds are benchmarked against IEEE 519:2022 and NRS 048-2:2025 respectively. Results show that while DER inverters introduce increasing odd-order harmonics, mainly the 3rd, 5th, 7th and 11th, the feeder’s moderate short-circuit capacity suppresses PCC voltage distortion, keeping voltage THD below 3% across all scenarios. As the inverter-based DER penetration increases, so does the harmonic current distortion. At 180%, Total Demand Distortion (TDD) nears the IEEE limit of 5%.


  • Open Access

    Voltage Regulation and SoC-Oriented Power Distribution in DC Microgrids via Distributed Control of Energy Storage Systems

    by Olanrewaju Lasabi, Mohamed Khan, Andrew Swanson, Leigh Jarvis, Anuoluwapo Aluko

    The rapid integration of renewable energy sources has accelerated the adoption of DC microgrids as an effective platform for flexible and reliable power generation and management. However, conventional droop-based control suffers from inherent limitations, particularly voltage deviations at the DC bus, which compromise stability, power-sharing accuracy, and overall system performance. To address these challenges, this paper presents a distributed secondary control framework for a standalone PV battery-based DC microgrid that achieves bus voltage regulation, precise power distribution, and state-of-charge (SoC) balancing across multiple energy storage units (ESUs). At the primary level, an adaptive mechanism is introduced that dynamically adjusts droop coefficients in response to the real-time SoC of each ESU, promoting balanced utilization of storage resources. At the secondary level, the strategy leverages limited peer-to-peer communication to exchange only aggregate power information, thereby enabling accurate load sharing while preserving scalability and plug-and-play capability. The control architecture further incorporates voltage and current error compensation, with parameters tuned using a Whale Optimization Algorithm to enhance dynamic response. Validation is carried out through a real-time simulation environment developed in MATLAB/Simulink R2024b and executed on a SpeedgoatTM platform. The results demonstrate robust SoC equalization, improved bus voltage stability, and reliable cooperative coordination, positioning the scheme as a practical solution for next-generation DC microgrids.


  • Open Access

    A Systematic Open Source Modeling Method for Energy and Power Systems: Solar PV Application

    by Peter Munyao Mutuku, Alan L. Leigh Jarvis, Andrew G. Swanson, Mohamed F. Khan

    Open source modeling has emerged as a transformative paradigm in energy and power systems studies by enabling transparent, reproducible and collaborative development of tools and models. However, limited access to high-resolution, localized input data restricts the accuracy and contextual relevance of many models, especially in regions with diverse climatic and infrastructural conditions. This paper introduces a novel, systematic Open Source Modeling Method for Energy and Power Systems (OSM-MEPS). Derived and synthesized from foundational steps outlined in modeling literature, OSM-MEPS is grounded in first-principles thinking, the scientific method and the engineering design process frameworks, ensuring technical rigor, empirical validation and adaptability. To demonstrate effectiveness, OSM-MEPS guided the modeling and simulation of a solar photovoltaic (PV) system using high-resolution weather and irradiance data for the year 2024 from Solcast-DNV. At the Serres-C site in Greece, OSM-MEPS model results achieved a strong fit with real-world solar PV energy data (MAE: 469.57 kWh, RMSE: 584.62 kWh, R2: 0.887), outperforming PVLIB (MAE: 1,400.39 kWh, RMSE: 1,526.11 kWh, R2: 0.232). Seasonal testing showed similar results: in May 2024, the OSM-MEPS model achieved R2: 0.917 vs. PVLIB’s –0.039; in December, it maintained R2: 0.873 vs. PVLIB’s 0.638. Geographic validation demonstrated generalizability. In Pretoria, the OSM-MEPS model outperformed PVLIB (R2: 0.443 vs. –0.239); in Adelaide, it maintained accuracy (R2: 0.866) while PVLIB failed (R2: –0.959). In Kisumu, both models had low correlation despite matching MAE (0.88 kWh), due to data gaps and limited shading metadata. A rooftop energy feasibility study was carried out in Njagu-Mhasibu-Ruiru Estate in Kenya, based on a solar PV installed capacity of 8.75 kW. The OSM-MEPS model predicted an annual yield of 14,329 kWh/year, compared to PVLIB’s estimate of 10,048 kWh/year and the GSA reference of 12,784 kWh/year. Overall, the results confirm that the OSM-MEPS method and its resulting model are robust and adaptable tools for high-resolution solar PV energy modeling across diverse geographic regions and weather conditions.


  • Open Access

    Comparative Analysis of Lithium-Ion Batteries and Liquid Air Energy Storage Systems for Grid Use

    by Matthew Brown, Alan L. Leigh Jarvis, Andrew G. Swanson

    The global energy landscape is undergoing a paradigm shift driven by the increasing penetration of renewable energy sources into the electrical power grid. However, the variable nature of renewables presents significant challenges for grid stability and reliability. Long-term grid-scale energy storage is crucial to overcoming these challenges and facilitating the transition from carbon-based generation. Effective long-term grid-scale energy storage solutions must possess large energy capacity, long lifespans, geographical flexibility, and be economically viable and technologically ready. Liquid Air Energy Storage (LAES) emerges as a promising solution, offering similar benefits to Compressed Air Energy Storage (CAES) but with higher energy densities (typically 5 to 10 times higher) and without the geographical constraints of underground caverns or the uneconomical nature of pressurised tanks. Lithium Battery Energy Storage (LiBES) has driven much of the growth in the stationary energy storage market. However, its limitations with regards to energy capacity and long-term storage suitability are well established. Furthermore, the synthetic inertia of LiBES, reliant on software-based control, lacks the inherent reliability of LAES’s physical inertia, which provides a direct and robust response to grid fluctuations. A comparative analysis of LAES versus LiBES is conducted from technical, environmental, and economic perspectives. The findings highlight the suitability of LAES over LiBES for long-term grid-scale applications. As a general trend, LAES offers a lower levelised cost of storage (LCOS) than LiBES demonstrating improved economic performance in scenarios with lower cycling frequencies and higher discount rates.


  • Open Access

    Influence of Conductor Temperature on the Voltage–Current Characteristic of Corona Discharge in a Coaxial Arrangement—Experiments and Simulation

    by Kayumba Grace Ilunga, Andrew Graham Swanson, Nelson Ijumba, Robert Stephen

    High-current-carrying capability with minimum thermal elongation is one of the key reasons for using high-temperature low-sag (HTLS) conductors in modern power systems. However, their higher operational temperature can significantly affect corona discharge characteristics. Corona is one of the key factors in transmission line design considerations. Corona discharge is the leading cause of audible noise, radio interference, and corona loss in power transmission systems. The influence of conductor temperature on corona discharge characteristics is investigated in this paper using experimental methods and computational simulations. A simulation framework has been developed in COMSOL Multiphysics using the physics of plasmas and electrostatics to simulate corona plasma dynamic behavior and electric field distribution. The results show that the conductor temperature enhances the ionization by electron impact, enhances the production of positive and negative ions, changes the electric field distribution, and increases the electron temperature. This analysis emphasizes that temperature-dependent conditions affect the inception and intensity of corona discharge. Additionally, an experimental model was developed to evaluate corona voltage–current characteristics under varying temperature conditions. The study presents both simulation results and a newly developed model for predicting corona current at high conductor temperatures.