RRRoma Račkienė

Roma Račkienė

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Roma Račkienė has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Ramūnas Deltuva

    Department of Electrical Power Systems, Faculty of Electrical and Electronics Engineering, Kaunas University of Technology, Studentų st. 48, 51367 Kaunas, Lithuania

    5 shared publications
  • Konstantinas Otas

    Faculty of Electrical and Electronics Engineering, Department of Electrical and Energy Systems, Kaunas University of Technology, Studentų St. 48, 51367 Kaunas, Lithuania

    4 shared publications
  • Robertas Lukočius

    Faculty of Electrical and Electronics Engineering, Department of Electrical and Energy Systems, Kaunas University of Technology, Studentų St. 48, 51367 Kaunas, Lithuania

    4 shared publications
  • Miglė Kriuglaitė

    Faculty of Electrical and Electronics Engineering, Department of Electrical and Energy Systems, Kaunas University of Technology, Studentų St. 48, 51367 Kaunas, Lithuania

    3 shared publications
  • Edgaras Polionis

    Faculty of Electrical and Electronics Engineering, Department of Electrical and Energy Systems, Kaunas University of Technology, Studentų St. 48, 51367 Kaunas, Lithuania

    2 shared publications
  • Tautvydas Šikšnys

    Faculty of Electrical and Electronics Engineering, Department of Electrical and Energy Systems, Kaunas University of Technology, Studentų St. 48, 51367 Kaunas, Lithuania

    2 shared publications

Latest Publications

  • Open Access

    Strategic Control Enhancements for Frequency Deviation Management in European Power Systems

    by Ramūnas Deltuva, Robertas Lukočius, Roma Račkienė, Konstantinas Otas, Miglė Kriuglaitė, Tautvydas Šikšnys, Edgaras Polionis

    This article examines the challenges and solutions related to frequency deviation (FD) in Continental Europe’s electric power systems, focusing on the effectiveness of Combined Cycle Power Blocks (CCPBs) in managing these deviations. Since 2023, persistent and significant frequency deviations (FDs) have been a concern, leading to the establishment of a working group by the ENTSO-E System Operation Committee to develop a robust action plan. The study highlights the necessity of employing advanced control strategies in CCPB to enhance frequency quality and ensure stable system operation. It delves into the mechanisms of Automatic Generation Control (AGC) to maintain power balance and frequency stability through primary and secondary controls. These controls are critical in adapting to real-time changes in load and generation, thereby securing the power system’s reliability and efficiency. The paper also discusses the implementation of Frequency Containment Reserves (FCRs) and their role in stabilizing system frequency following disturbances by automatically adjusting power outputs. Additionally, the research explores the integration of the Baltic States into the European Union (EU) energy market, aiming for enhanced system security and reliability. After all, the Baltic States achieved full synchronization with the Continental Europe Synchronous Area (CESA). The outcomes confirm the suitability of the investigated CCPB for participation in AGC and FCR services under interconnected system operation.

  • Open Access

    Cybersecurity Requirements and Certification Standards in Industrial Automation Systems: A Systematic Review

    by Said Zulfigarzada, Aysun Gadirli, Javid Karimov, Danas Cerneckas, Roma Rackiene, Mindaugas Azubalis

    Industrial automation systems are increasingly cyber-physical, interconnected, and software-dependent, which expands both their operational capability and their cybersecurity exposure. This article reports a systematic literature review, conducted following the PRISMA 2020 guidelines, of cybersecurity requirements and certification standards in industrial automation, with emphasis on Industrial Control Systems (ICS), Supervisory Control and Data Acquisition (SCADA), Programmable Logic Controllers (PLCs), and Industry 4.0 contexts. From 3570 records identified across five academic databases, 75 studies were retained after duplicate removal, title and abstract screening, and full-text eligibility assessment. The included studies were analyzed along three dimensions: cybersecurity requirements, standards and certification, and application context. Quantitative synthesis shows that network segmentation, intrusion detection, secure communication, access control, lifecycle security, and safety–security coordination are the six most frequently emphasized requirement categories, and that ISA/IEC 62443, ISO/IEC 27001, NIST SP 800-82, and NERC-CIP are the four dominant certification frameworks. The review identifies four critical gaps between technical cybersecurity requirements and certification practice and proposes an integrated mapping framework linking requirement categories, standards, and application contexts. The findings indicate that effective industrial cybersecurity assurance depends on a layered compliance architecture rather than on dependence on any single framework.

  • Open Access

    Strategic Control Enhancements for Frequency Deviation Management in European Power Systems

    by Ramūnas Deltuva, Robertas Lukočius, Roma Račkienė, Konstantinas Otas, Miglė Kriuglaitė, Tautvydas Šikšnys, Edgaras Polionis

    This article examines the challenges and solutions related to Frequency Deviation (FD) in Continental Europe's electric power systems, focusing on the effectiveness of Combined Cycle Power Blocks (CCPB) in managing these deviations. Already since 2023, persistent and significant FD's have been a concern, leading to the establishment of a working group by the ENTSO-E System Operation Committee to develop a robust action plan. The study highlights the necessity of employing advanced control strategies in CCPB to enhance frequency quality and ensure stable system operation. It delves into the mechanisms of Automatic Generation Control (AGC) to maintain power balance and frequency stability through primary and secondary controls. These controls are critical in adapting to real-time changes in load and generation, thereby securing the power system's reliability and efficiency. The paper also discusses the implementation of Frequency Containment Reserves (FCR) and their role in stabilizing the frequency post-disturbances by automatically adjusting power outputs. Additionally, the research explores the integration of the Baltic States into the European Union (EU) energy market aiming for enhanced system security and reliability, after all the Baltic States achieved full synchronization with the Continental Europe Synchronous Area (CESA). The outcomes suggest that strategic enhancements in automatic control and reserve management can significantly mitigate FD impacts, contributing to the stability of large-scale interconnected power systems.

  • Open Access

    LFC and Reserve Prequalification for Synchronization with Continental Europe Synchronous Area

    by Ramūnas Deltuva, Miglė Kriuglaitė, Roma Račkienė, Konstantinas Otas

    This paper presents a comprehensive analysis of the Load Frequency Control (LFC) framework required for the synchronization of Electric Power Systems (EPSs) with Continental Europe (CE). The study focuses on ensuring stable and reliable operation of autonomously functioning EPSs by examining technical requirements and prequalification procedures for Frequency Containment Reserve (FCR) and LFC-related reserves. Numerical simulations were performed to assess system dynamic behavior under disturbance conditions. The results indicate that following a 100 MW active power loss, system frequency decreased to 49.82 Hz and was restored to the nominal 50 Hz within 9 min using FCR and automatic Frequency Restoration Reserve (aFRR). A more severe 200 MW disturbance resulted in a minimum frequency of 49.68 Hz, requiring additional activation of manual Frequency Restoration Reserve (mFRR), with recovery achieved in 18 minutes. In extreme scenarios involving up to 600 MW power loss, the frequency dropped below the critical threshold of 49.2 Hz, but full restoration was achieved within 36 min through coordinated activation of FCR, aFRR, mFRR, and Replacement Reserve (RR). Long-term simulations demonstrated that the Frequency Restoration Control Error (FRCE) remained within the System Operation Guidelines (SOGL) Level 1 limit for 75% of the time and within the stricter Level 2 limit for 96%, meeting CE quality requirements. The study also evaluates prequalification procedures, including technical testing, communication validation, and energy management for Limited Energy Reservoir providers, ensuring robust and non-discriminatory participation in balancing markets.

  • Open Access

    The influence of flow admixtures to the electromagnetic flow meter accuracy

    by R. Račkienė, J.A. Virbalis

    The measurement error appears in an electromagnetic flow meter when the flow has admixtures with magnetic and/or electric properties different from the fluid. The particle shape approximates the ellipsoid. The reasons of error appeared inside and outside of the particles in the active zone of the flow meter with any canal form and turbulent flow investigated. The investigation is performed by analogy among electrostatic, magnetic, and electric current fields. Expressions for error depending on volume concentration, permeability, electric conductivity of particles, and different ellipsoid axes lengths are presented. The expressions of the error are obtained assuming that particles are oriented in various directions concerning the flow direction. Magnetic particles with the considerable value of electric conductivity are dangerous in particular. The extra measurement error depends on particle shape in this case especially. The measurement error increases if the particle shape differs from the sphere. The complementary measurement error can exceed some hundred times the volume concentration of particles if the ratio between the longest and shortest axes of the ellipsoid exceeds 10. The error is proportional to the second power of admixtures volume concentration when particles are nonmagnetic. When admixtures are nonmagnetic and nonconductive, the measurement error does not depend on the particle’s shape.

  • Elektros grandinių laboratoriniai darbai, I d.

    by Robertas Lukočius, Povilas Marčiulionis, Roma Račkienė, Ramūnas Deltuva

    Elektros grandinių laboratoriniai darbai, I d. - Nedidelės apimties leidinyje elektros inžinerijos ir energetikos bakalaurantai ras visą jų studijų moduliui „Elektros grandinių analizė, I dalis“ reikalingą informaciją apie metodinius nurodymus, darbų saugos instrukcijas ir svarbiausia – 5 laboratorinius darbus, kurie apima pagrindinius elektros grandinių veikimo principus. Šis leidinys bus išties naudingas tiems, kurie nori nesiblaškydami, greitai ir kokybiškai pagilinti ir pakartoti elektros grandinių kursą ir kartu žinias panaudoti praktikoje: pasitelkiant šią laboratorinių darbų metodinę priemonę, galima išmokti savarankiškai sujungti grandines pagal schemas, kad būtų galima eksperimentiškai atkurti ir patikrinti įvairius teorijoje išnagrinėtus reiškinius, susipažinti su elektriniais matavimais, palyginti teorinius ir eksperimentinius rezultatus, padaryti išvadas. Leidinyje išsamiai pateikiami metodiniai reikalavimai padės aiškiai ir lengvai suprasti, nuo ko pradėti laboratorinį darbą ir kokie yra pagrindiniai žingsniai siekiant jį teisingai atlikti. Dėl savo išsamaus turinio metodinė priemonė gali būti naudinga tiek patyrusiems šioje srityje ir norintiems pagilinti bei pasitikrinti sukauptas žinias, tiek pradedantiems susipažinti su šia sritimi.

  • Open Access

    The Influence of Admixtures to the Signal of an Electromagnetic Flow Meter

    by Juozapas Arvydas Virbalis, Roma Račkienė, Miglė Kriuglaitė-Jarašiūnienė, Konstantinas Otas

    Measurement error in an electromagnetic flow meter appears if magnetic and electric properties of admixtures are different from that of the fluid. Expressions of the error, which depends on volume concentration, permeability, and electric conductivity of particles were obtained by approximating the particles’ shape as an ellipsoid. Components of the error, which appear inside particles and outside particles in active zone of flow meter, with any canal form are investigated. Expressions of the error are presented assuming that particles are oriented in various directions with respect of the flow direction and are spinning. Different cases of magnetic and electric admixtures properties are discussed. Error expression obtained for flows with nonconductive and nonmagnetic particles coincides with experimental and modelling results obtained by other explorers for flows with air bubbles. Magnetic particles with high electric conductivity are especially dangerous. Extra measurement error in this case greatly depends on the shape of the particle. Measurement error increases if particle shape differs from a sphere. The complementary measurement error can exceed the volume concentration of particles by ten times if the ratio between the longest and the shortest axes of ellipsoid exceeds 3.


  • Open Access

    An Analysis of the Systematic Error of a Remote Method for a Wattmeter Adjustment Gain Estimation in Smart Grids

    by Robertas Lukočius, Žilvinas Nakutis, Vytautas Daunoras, Ramūnas Deltuva, Pranas Kuzas, Roma Račkienė

    Smart energy meters supporting bidirectional data communication enable novel remote error monitoring applications. This research targets characterization of the systematic worst-case error of the previously published remote watthour meter’s gain estimation method based on the comparison of synchronous measurements by the reference and meter under test. To achieve the research aim a methodology based on global maximization of the systematic error objective function assuming the typical low voltage electrical distribution network operation parameters ranges as defined by the standard recommendations for network design. To cross verify the reliability of the assessed solutions the suggested error analysis methodology was implemented utilizing two stochastic global extremum search techniques (genetic algorithms, pattern search) and the third one utilizing nonlinear programming solver. It was determined that the wattmeter adjustment gain worst-case error does not exceed 0.5% if the remote wattmeter monitored load power factor is larger than 0.1 and a network is designed according to the recommendation of the acceptable voltage drop less than 5%. For a load exhibiting power factor larger than cos φ = 0.9 the worst-case error was found to be less than 0.1%. It is concluded therefore that considering the systematic worst-case error the previously suggested remote wattmeter adjustment gain estimation method is suitable for remote error monitoring of Class 2 and Class 1 wattmeters.