SSSøren Nielsen Skov

Søren Nielsen Skov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Søren Nielsen Skov has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Marcell Juan Tjørnild

    Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark

    4 shared publications
  • Christine Ilkjær

    Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark

    3 shared publications
  • Hans Nygaard

    Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark

    3 shared publications
  • Diana Mathilde Røpcke

    Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark

    2 shared publications
  • Jonas Rasmussen

    Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark

    2 shared publications
  • Morten Olgaard Jensen

    Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark

    2 shared publications

Latest Publications

  • Open Access

    In-vitro and in-vivo evaluation of a novel bioprosthetic pulmonary valve for use in congenital heart surgery

    by Jonas Rasmussen, Søren Nielsen Skov, Ditte Bruus Nielsen, Ida Lindhardt Jensen, Marcell Juan Tjørnild, Peter Johansen, Vibeke E. Hjortdal

    Management of congenital malformations of the pulmonary artery and valve can be challenging. The severity often demands early intervention, which is rarely definitive due to the natural growth and multiple surgeries may be required. An artificial valve made entirely from biodegradable materials that will serve as a bioscaffold for host recellularization would be an attractive solution for these patients. Such valves have been experimentally evaluated with various results. In this study, a simple valve design supported by an absorbable proximal stabilization ring is evaluated both in-vitro and in-vivo. From a 6.7 × 5.0 cm sheet of CorMatrix® tissue we created the valve as an inverted tubegraft with three sutured commissures. A non-closed ring of LactoSorb® basally supported the valve. The commissure height was 2 cm. Inserted as an interposition graft the valve was tested in an in-vitro model and an acute porcine model. Right ventricular and pulmonary artery pressures were recorded. The in-vitro testing indicated a proper opening and closure function of valve at physiological simulated hemodynamic conditions. The in-vivo evaluation showed a peak right ventricular pressure of 38 mmHg and a peak pulmonary artery pressure of 27 mmHg and thereby a peak valve gradient of 11 mmHg. The pulmonary pressure wave demonstrated a dicrotic notch indicating competence of the valve. This new pulmonary valve made entirely from biodegradable tissue worked in an acute setting and displayed a good hemodynamic profile. The valve gradient observed is equal to or superior of today’s surgical treatment options.


  • Open Access

    The effect of different mitral annuloplasty rings on valve geometry and annular stress distribution†

    by Søren Nielsen Skov, Diana Mathilde Røpcke, Marcell Juan Tjørnild, Christine Ilkjær, Jonas Rasmussen, Hans Nygaard, Morten Olgaard Jensen, Sten Lyager Nielsen

    OBJECTIVES: To characterize the remodelling effects and deformational forces of normosized rigid, semirigid and flexible mitral annuloplasty rings after implantation in healthy pigs. METHODS: Measurements were performed in vivo with 80-kg porcine animals. Twenty-eight animals were randomized into a no ring group, a flexible ring group (Duran AnCore Ring, Medtronic, Minneapolis, MN, USA), a rigid ring group (Carpentier-Edwards Classic annuloplasty ring, Edwards Lifesciences, Irvine, CA, USA) and a semirigid ring group (Carpentier-Edwards Physio I annuloplasty ring, Edwards Lifesciences). Sonomicrometry crystals were implanted together with an annuloplasty ring and a dedicated mitral annular force transducer. The mitral annuloplasty rings were compared with respect to annular geometry and mitral annular forces. RESULTS: Cyclic changes in the mitral annulus (MA) circumference were significantly lower for all ring groups (flexible: 7 ± 3 mm, semirigid: 4 ± 2 mm and rigid: 2 ± 1 mm) compared to the no ring group (11 ± 5 mm), implying the remodelling capacity of all annuloplasty rings. The cyclic change of the MA area and the septa-lateral and inter-commissural distances were equal in the semirigid and rigid ring groups and significantly lower compared to the no ring and flexible ring groups, suggesting a stronger and equal remodelling effect in the semirigid and rigid ring groups. Forces measured in the transducer reflected the remodelling capacity of the annuloplasty rings and were in general lower for the semirigid and rigid ring groups compared to the no ring and flexible ring groups. Especially the forces in the inter-commissural direction were significantly reduced for the semirigid and rigid ring groups (semi-rigid: 1.4 ± 0.8 N, rigid: 1.2 ± 0.8 N) compared to the no ring and flexible ring groups (no ring: 3.0 ± 1.1 N, flexible: 3.4 ± 1.6 N). CONCLUSIONS: This study is the first to describe different remodelling effects and deformational forces of normosized mitral annuloplasty rings in vivo. Insights into the relationship between the remodelling effects and the accumulated forces of different mitral annuloplasty rings may have implications for ring selections in an aetiology-based mitral valve repair strategy. We propose the application of such a biomechanical approach for quantitative comparison of mitral annuloplasty rings and for future innovations on a rational basis.


  • Semi-rigid mitral annuloplasty rings improve myocardial stress adaptation compared to rigid rings: insights from in vitro and in vivo experimental evaluation†

    by Søren Nielsen Skov, Diana Mathilde Røpcke, Marcell Juan Tjørnild, Christine Ilkjær, Jonas Rasmussen, Hans Nygaard, Morten Olgaard Jensen, Sten Lyager Nielsen


  • Simultaneous in- and out-of-plane Mitral Valve Annular Force Measurements

    by Søren N. Skov, Diana M. Røpcke, Kristine Telling, Christine Ilkjær, Marcell J. Tjørnild, Hans Nygaard, Sten L. Nielsen, Morten O. Jensen

    Mitral valve repair with annuloplasty is often favoured over total valve replacement. In order to develop and optimize new annuloplasty ring designs, it is important to study the complex biomechanical behaviour of the valve annulus and the subvalvular apparatus with simultaneous in- and out-of-plane restraining force measurements. A new flat D-shaped mitral valve annular force transducer was developed. The transducer was mounted with strain gauges to measure strain and calibrated to provide simultaneous restraining forces in- and out of the mitral annular plane. The force transducer was implanted and evaluated in an 80 kg porcine experimental model. Accumulation of out-of-plane restraining forces, creating strain in the anterior segment were 0.7 ± 0.0 N (towards apex) and an average force accumulation of 1.5 ± 0.3 N, creating strain in the commissural segments (away from apex). The accumulations of in-plane restraining forces, creating strain on the inner side of the ring were 1.7 ± 0.2 N (away from ring center). A new mitral annular force transducer was successfully developed and evaluated in vivo. The transducer was able to measure forces simultaneously in different planes. Initial indications point towards overall agreement with previous individual force measurements in- and out-of the mitral annular plane. This can provide more detailed insight into the annular force distribution, and could potentially improve the level of evidence based mitral valve repair and support the development of future mitral annuloplasty devices.