Simultaneous in- and out-of-plane Mitral Valve Annular Force Measurements
- 1 May 2015
- journal article
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 6 (2) , 185-192
Abstract
Mitral valve repair with annuloplasty is often favoured over total valve replacement. In order to develop and optimize new annuloplasty ring designs, it is important to study the complex biomechanical behaviour of the valve annulus and the subvalvular apparatus with simultaneous in- and out-of-plane restraining force measurements. A new flat D-shaped mitral valve annular force transducer was developed. The transducer was mounted with strain gauges to measure strain and calibrated to provide simultaneous restraining forces in- and out of the mitral annular plane. The force transducer was implanted and evaluated in an 80 kg porcine experimental model. Accumulation of out-of-plane restraining forces, creating strain in the anterior segment were 0.7 ± 0.0 N (towards apex) and an average force accumulation of 1.5 ± 0.3 N, creating strain in the commissural segments (away from apex). The accumulations of in-plane restraining forces, creating strain on the inner side of the ring were 1.7 ± 0.2 N (away from ring center). A new mitral annular force transducer was successfully developed and evaluated in vivo. The transducer was able to measure forces simultaneously in different planes. Initial indications point towards overall agreement with previous individual force measurements in- and out-of the mitral annular plane. This can provide more detailed insight into the annular force distribution, and could potentially improve the level of evidence based mitral valve repair and support the development of future mitral annuloplasty devices.Keywords
This publication has 17 references indexed in Scilit:
- Mitral valve annular downsizing forces: Implications for annuloplasty device developmentThe Journal of Thoracic and Cardiovascular Surgery, 2014
- In-plane Tricuspid Valve Force Measurements: Development of a Strain Gauge Instrumented Annuloplasty RingCardiovascular Engineering and Technology, 2013
- Mitral Valve AnnuloplastyAnnals of Biomedical Engineering, 2011
- Saddle-shaped mitral valve annuloplasty rings improve leaflet coaptation geometryThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Trends in Mitral Valve Surgery in the United States: Results From The Society of Thoracic Surgeons Adult Cardiac DatabaseThe Annals of Thoracic Surgery, 2009
- Saddle-Shaped Mitral Valve Annuloplasty Rings Experience Lower Forces Compared With Flat RingsCirculation, 2008
- The Influence of Annuloplasty Ring Geometry on Mitral Leaflet CurvatureThe Annals of Thoracic Surgery, 2008
- Burden of valvular heart diseases: a population-based studyThe Lancet, 2006
- Prevalence and Clinical Outcome of Mitral-Valve ProlapseThe New England journal of medicine, 1999
- Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse.Circulation, 1989