Kunihiro Kato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kunihiro Kato has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Kaori Ikematsu
LY Corporation, Tokyo, Japan
18 shared publications - Yuta Sugiura
Keio University, Yokohama, Japan
7 shared publications - Toshiya Isomoto
LY Corporation, Chiyoda, Tokyo, Japan
4 shared publications - Takashi Ohta
School of Media Science, Tokyo University of Technology, Tokyo, Japan
3 shared publications - Hiromi Nakamura
Rekimoto Lab, The University of Tokyo, Japan
2 shared publications - Komei Tajima
Department of Information and Computer Science, Faculty of Science and Technology, Keio University, Yokohama, Kanagawa, Yokohama, Japan
2 shared publications
Latest Publications
- Open Access
- 5 December 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-3
Fabricating Electrical Circuits on Glazed Ceramic Surfaces Using Overglaze Gilt Decoration
- 5 December 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-3
Open AccessFabricating Electrical Circuits on Glazed Ceramic Surfaces Using Overglaze Gilt Decoration
- Open Access
- 23 April 2026
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 13 (1) , e90316
Grip Strength Estimation Using Input Data From a Commodity Smartphone: Model Development and Validation Study
Background: Grip strength is a crucial indicator of muscle deterioration, recovery, sarcopenia, and neurological disorders. However, conventional measurement requires a dedicated dynamometer, which limits accessibility and requires specific movements. Objective: This study aimed to propose and validate a method for estimating grip strength using standard smartphone operations, thereby eliminating the need for specialized equipment. Methods: Data were collected from 21 young adults in the main experiment, who performed standard smartphone tasks (tapping, flicking, and dragging) after measuring their grip strength with a dynamometer. A predictive regression model was developed using touch and inertial sensor data. The model was first evaluated using a random split of the entire dataset (random split evaluation). To further assess practical feasibility and generalizability, we conducted leave-one-user-out validation and a few-day calibration validation; the latter simulated a calibration scenario by incorporating 1 to 4 days of user-specific data into the training set. Results: The regression analysis using a random split of the dataset demonstrated high accuracy, with a mean absolute error of 2.62 (SD 0.18) kg, a mean absolute percentage error (MAPE) of 8.91% (SD 0.57%), and a coefficient of determination of 0.802 (SD 0.036). In the validation of practical scenarios, the leave-one-user-out validation resulted in a MAPE of 15.08% (SD 5.40%). However, the personalized few-day calibration model showed significant improvements as calibration days increased, with the MAPE decreasing to 13.96% (SD 5.57%) after 1 day and reaching 11.64% (SD 5.80%) after 4 days. Furthermore, the National Aeronautics and Space Administration Task Load Index assessment indicated a low overall subjective workload (mean 3.04, SD 2.23 on a scale of 10), confirming the method’s suitability for daily use without a significant burden on users. Conclusions: The proposed method demonstrates that smartphones can serve as a viable, pervasive tool for daily grip strength monitoring, offering a convenient alternative to traditional dynamometers.
- 23 April 2026
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 13 (1) , e90316
Open AccessGrip Strength Estimation Using Input Data From a Commodity Smartphone: Model Development and Validation Study
Background: Grip strength is a crucial indicator of muscle deterioration, recovery, sarcopenia, and neurological disorders. However, conventional measurement requires a dedicated dynamometer, which limits accessibility and requires specific movements. Objective: This study aimed to propose and validate a method for estimating grip strength using standard smartphone operations, thereby eliminating the need for specialized equipment. Methods: Data were collected from 21 young adults in the main experiment, who performed standard smartphone tasks (tapping, flicking, and dragging) after measuring their grip strength with a dynamometer. A predictive regression model was developed using touch and inertial sensor data. The model was first evaluated using a random split of the entire dataset (random split evaluation). To further assess practical feasibility and generalizability, we conducted leave-one-user-out validation and a few-day calibration validation; the latter simulated a calibration scenario by incorporating 1 to 4 days of user-specific data into the training set. Results: The regression analysis using a random split of the dataset demonstrated high accuracy, with a mean absolute error of 2.62 (SD 0.18) kg, a mean absolute percentage error (MAPE) of 8.91% (SD 0.57%), and a coefficient of determination of 0.802 (SD 0.036). In the validation of practical scenarios, the leave-one-user-out validation resulted in a MAPE of 15.08% (SD 5.40%). However, the personalized few-day calibration model showed significant improvements as calibration days increased, with the MAPE decreasing to 13.96% (SD 5.57%) after 1 day and reaching 11.64% (SD 5.80%) after 4 days. Furthermore, the National Aeronautics and Space Administration Task Load Index assessment indicated a low overall subjective workload (mean 3.04, SD 2.23 on a scale of 10), confirming the method’s suitability for daily use without a significant burden on users. Conclusions: The proposed method demonstrates that smartphones can serve as a viable, pervasive tool for daily grip strength monitoring, offering a convenient alternative to traditional dynamometers.
- Open Access
- 13 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-16
DuoTouch: Passive Two-Footprint Attachments Using Binary Sequences to Extend Touch Interaction
- 13 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-16
Open AccessDuoTouch: Passive Two-Footprint Attachments Using Binary Sequences to Extend Touch Interaction
- Open Access
- 22 March 2026
- Published by Association for Computing Machinery (ACM)
- p. 1855-1866
ReflecTrace: Touchless Hover Interaction on Commodity Smartphones via Corneal Reflection
- 22 March 2026
- Published by Association for Computing Machinery (ACM)
- p. 1855-1866
Open AccessReflecTrace: Touchless Hover Interaction on Commodity Smartphones via Corneal Reflection
- Open Access
- 22 March 2026
- Published by Association for Computing Machinery (ACM)
- p. 22-25
Detecting and Recovering from Human Errors using Multimodal Sensor Data Obtained by Smartphone
Touchscreen devices like smartphones and tablets are ubiquitous, yet unintended touches and selection errors still impair user experience. We present a multimodal method to detect touch-level human errors from motion, touch, gaze, and facial cues on smartphones, and to trigger lightweight, user-controlled recovery suggestions. In a study with 15 participants (15,636 touch-up events; 2,700 labeled errors), our models achieved strong performance in both personalization and cross-user settings, measured by ROC-AUC. With personalized models, XGBoost reached near-ceiling performance (Text: ROC-AUC 1.00, Acc. 0.99; Image: ROC-AUC 1.00, Acc. 0.99). For cross-user generalization under leave-one-user-out (LOUO), an RNN achieved high performance on text typing (ROC-AUC 0.99, Acc. 0.96) and moderate performance on image selection (ROC-AUC 0.68, Acc. 0.68). We further report stepwise personalization trends and a camera-off ablation to clarify modality contributions, and discuss implications for practical recovery-oriented mobile UIs.
- 22 March 2026
- Published by Association for Computing Machinery (ACM)
- p. 22-25
Open AccessDetecting and Recovering from Human Errors using Multimodal Sensor Data Obtained by Smartphone
Touchscreen devices like smartphones and tablets are ubiquitous, yet unintended touches and selection errors still impair user experience. We present a multimodal method to detect touch-level human errors from motion, touch, gaze, and facial cues on smartphones, and to trigger lightweight, user-controlled recovery suggestions. In a study with 15 participants (15,636 touch-up events; 2,700 labeled errors), our models achieved strong performance in both personalization and cross-user settings, measured by ROC-AUC. With personalized models, XGBoost reached near-ceiling performance (Text: ROC-AUC 1.00, Acc. 0.99; Image: ROC-AUC 1.00, Acc. 0.99). For cross-user generalization under leave-one-user-out (LOUO), an RNN achieved high performance on text typing (ROC-AUC 0.99, Acc. 0.96) and moderate performance on image selection (ROC-AUC 0.68, Acc. 0.68). We further report stepwise personalization trends and a camera-off ablation to clarify modality contributions, and discuss implications for practical recovery-oriented mobile UIs.
- Open Access
- 25 December 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Grip Strength Estimation Using Input Data From a Commodity Smartphone: Model Development and Validation Study (Preprint)
BACKGROUND Grip strength is a crucial indicator of muscle deterioration, recovery, sarcopenia, and neurological disorders. However, conventional measurement requires a dedicated dynamometer, which limits accessibility and requires specific movements. OBJECTIVE This study aimed to propose and validate a method for estimating grip strength using standard smartphone operations, thereby eliminating the need for specialized equipment. METHODS Data were collected from 21 young adults in the main experiment, who performed standard smartphone tasks (tapping, flicking, and dragging) after measuring their grip strength with a dynamometer. A predictive regression model was developed using touch and inertial sensor data. The model was first evaluated using a random split of the entire dataset (random split evaluation). To further assess practical feasibility and generalizability, we conducted leave-one-user-out validation and a few-day calibration validation; the latter simulated a calibration scenario by incorporating 1 to 4 days of user-specific data into the training set. RESULTS The regression analysis using a random split of the dataset demonstrated high accuracy, with a mean absolute error of 2.62 (SD 0.18) kg, a mean absolute percentage error (MAPE) of 8.91% (SD 0.57%), and a coefficient of determination of 0.802 (SD 0.036). In the validation of practical scenarios, the leave-one-user-out validation resulted in a MAPE of 15.08% (SD 5.40%). However, the personalized few-day calibration model showed significant improvements as calibration days increased, with the MAPE decreasing to 13.96% (SD 5.57%) after 1 day and reaching 11.64% (SD 5.80%) after 4 days. Furthermore, the National Aeronautics and Space Administration Task Load Index assessment indicated a low overall subjective workload (mean 3.04, SD 2.23 on a scale of 10), confirming the method’s suitability for daily use without a significant burden on users. CONCLUSIONS The proposed method demonstrates that smartphones can serve as a viable, pervasive tool for daily grip strength monitoring, offering a convenient alternative to traditional dynamometers.
- 25 December 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessGrip Strength Estimation Using Input Data From a Commodity Smartphone: Model Development and Validation Study (Preprint)
BACKGROUND Grip strength is a crucial indicator of muscle deterioration, recovery, sarcopenia, and neurological disorders. However, conventional measurement requires a dedicated dynamometer, which limits accessibility and requires specific movements. OBJECTIVE This study aimed to propose and validate a method for estimating grip strength using standard smartphone operations, thereby eliminating the need for specialized equipment. METHODS Data were collected from 21 young adults in the main experiment, who performed standard smartphone tasks (tapping, flicking, and dragging) after measuring their grip strength with a dynamometer. A predictive regression model was developed using touch and inertial sensor data. The model was first evaluated using a random split of the entire dataset (random split evaluation). To further assess practical feasibility and generalizability, we conducted leave-one-user-out validation and a few-day calibration validation; the latter simulated a calibration scenario by incorporating 1 to 4 days of user-specific data into the training set. RESULTS The regression analysis using a random split of the dataset demonstrated high accuracy, with a mean absolute error of 2.62 (SD 0.18) kg, a mean absolute percentage error (MAPE) of 8.91% (SD 0.57%), and a coefficient of determination of 0.802 (SD 0.036). In the validation of practical scenarios, the leave-one-user-out validation resulted in a MAPE of 15.08% (SD 5.40%). However, the personalized few-day calibration model showed significant improvements as calibration days increased, with the MAPE decreasing to 13.96% (SD 5.57%) after 1 day and reaching 11.64% (SD 5.80%) after 4 days. Furthermore, the National Aeronautics and Space Administration Task Load Index assessment indicated a low overall subjective workload (mean 3.04, SD 2.23 on a scale of 10), confirming the method’s suitability for daily use without a significant burden on users. CONCLUSIONS The proposed method demonstrates that smartphones can serve as a viable, pervasive tool for daily grip strength monitoring, offering a convenient alternative to traditional dynamometers.
- 23 December 2025
- Published by Taylor & Francis in International Journal of Human–Computer Interaction
- Vol. 42 (15) , 1-21
Leveraging Screen-Integrated Speakers for Hand-Pose Recognition in Mobile Interfaces
- 23 December 2025
- Published by Taylor & Francis in International Journal of Human–Computer Interaction
- Vol. 42 (15) , 1-21
Leveraging Screen-Integrated Speakers for Hand-Pose Recognition in Mobile Interfaces
- Open Access
- 27 September 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-3
Passive Attachments for Back-of-Device Interaction via Binary Touch Sequences
- 27 September 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-3
Open AccessPassive Attachments for Back-of-Device Interaction via Binary Touch Sequences
- Open Access
- 27 September 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-3
ReflecTrace: Hover Interface using Corneal Reflection Images Captured by Smartphone Front Camera
- 27 September 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-3
Open AccessReflecTrace: Hover Interface using Corneal Reflection Images Captured by Smartphone Front Camera