  • Safety, Tolerability, and Effects of Sodium Bicarbonate Inhalation in Cystic Fibrosis

    by Carla Cristina Souza Gomez, Paloma Lopes Francisco Parazzi, Karl Jan Clinckspoor, Renan Marrichi Mauch, Francisco Benedito Teixeira Pessine, Carlos Emilio Levy, Andressa Oliveira Peixoto, Maria Ângela Gonçalves Oliveira Ribeiro, Antônio Fernando Ribeiro, Douglas Conrad, et al.

    Among the many consequences of loss of CFTR protein function, a significant reduction of the secretion of bicarbonate (HCO3−) in cystic fibrosis (CF) is a major pathogenic feature. Loss of HCO3− leads to abnormally low pH and impaired mucus clearance in airways and other exocrine organs, which suggests that NaHCO3 inhalation may be a low-cost, easily accessible therapy for CF.


  • Open Access

    Evaluation of continuous constant current and continuous pulsed current in sweat induction for cystic fibrosis diagnosis

    by Carla Cristina Souza Gomez, Fernando Augusto Lima Marson, Maria Fátima Servidoni, Antônio Fernando Ribeiro, Maria Ângela Gonçalves Oliveira Ribeiro, Veruska Acioli Lopes Gama, Eduardo Tavares Costa, José Dirceu Ribeiro, Francisco Ubaldo Vieira Junior

    The sweat test (ST) is the gold standard for the diagnosis of cystic fibrosis (CF). However, little is known about sweat induction using different types of currents and waves. In this context, our objective was to develop a device to induce sweat and compare the use of continuous constant current (CCC) and continuous pulsed current (CPC) in individuals with CF and healthy controls. A prospective cross-sectional study with experimental intervention. The variables of gender, ethnicity, age, and body mass index (BMI) were considered. The method of Gibson and Cooke was used, and the following markers were evaluated: sweat weight, electrical impedance, sufficient sweat amount, and CF diagnosis. Triangular (TPC) or sinusoidal (SPC) pulsed current was applied to the right arm, and CCC was applied to the left arm. The study analyzed 260 individuals, 141/213 (54.2%) were female participants, 135/260 (51.9%) were Caucasians. The distribution of individuals by concentration of chloride at the ST was: (CF) 26/260 (10%); (borderlines) 109/260 (41.9%); (healthy) 97/260 (37.3%); (insufficient weight in sweat) 28/260 (10.8%). No association was observed between the sufficient sweat amount to perform the ST when we compared the currents. However, the SPC showed a higher amount of sweat weight. Using Bland and Altman plot considering the agreement between the sweat chloride values achieved from CPC [SPC and TPC] and CCC, there was no proportional bias and mean values are unrelated and only explain less than 8% of the variation. Moreover, TPC presented higher electrical impedance when compared with SPC and CCC. SPC presented lower electrical impedance and higher sweat weight than CCC. Male participants presented lower electrical impedance and higher sweat weight with CCC and TPC, and higher sweat weight with SPC. The evaluated currents are safe and able to induce and produce sweat in sufficient quantities for the ST. SPC presented lower electrical impedance when compared with other currents. The use of SPC is recommended to induce sweat in patients with sweat problems. Finally, ethnicity, gender, age and BMI did not influence sweat induction at the ST, and no side effect was observed in our study.


  • Open Access

    Quality of sweat test (ST) based on the proportion of sweat sodium (Na) and sweat chloride (Cl) as diagnostic parameter of cystic fibrosis: are we on the right way?

    by Alethéa Guimarães Faria, Fernando Augusto Lima Marson, Carla Cristina de Souza Gomez, Maria Ângela Gonçalves de Oliveira Ribeiro, Lucas Brioschi Morais, Maria de Fátima Servidoni, Carmen Sílvia Bertuzzo, Eulália Sakano, Maura Goto, Ilma Aparecida Paschoal, et al.

    To assess the quality of sweat test (ST) based on the proportion of sweat sodium and sweat chloride as diagnostic parameter of cystic fibrosis (CF). A retrospective study of 5,721 sweat samples and subsequent descriptive analysis were carried out. The test was considered “of good quality” (correct) when: (i) sweat chloride was lower than 60 mEq/L, and sweat sodium was higher than sweat chloride; (ii) sweat chloride was higher than 60 mEq/L, and sweat sodium was lower than sweat chloride. The study included 5,692/5,721 sweat samples of ST which had been requested due to clinical presentations compatible with CF and/or neonatal screenings with altered immunoreactive trypsinogen values. Considering the proportion of sweat sodium and sweat chloride as ST quality parameter, the test was performed correctly in 5,023/5,692 (88.2 %) sweat samples. The sweat chloride test results were grouped into four reference ranges for chloride (i) chloride < 30 mEq/L: 3,651/5,692 (64.1 %); (ii) chloride ≥ 30 mEq/L to < 40 mEq/L: 652/5,692 (11.5 %); (iii) ≥ 40 mEq/L to < 60 mEq/L: 673/5,692 (11.8 %); (iv) ≥ 60 mEq/L: 716/5,692 (12.6 %). In the comparative analysis, there was no association between ST quality and: (i) symptoms to indicate a ST [respiratory (p = 0.084), digestive (p = 0.753), nutritional (p = 0.824), and others (p = 0.136)], (ii) sweat weight (p = 0.416). However, there was a positive association with: (i) gender, (ii) results of ST (p < 0.001), (iii) chloride/sodium ratio (p < 0.001), (iv) subject’s age at the time of ST [grouped according to category (p < 0.001) and numerical order (p < 0.001)]. For the subset of 169 patients with CF and two CFTR mutations Class I, II and/or III, in comparative analysis, there was a positive association with: (i) sweat chloride/sodium ratio (p < 0.001), (ii) sweat chloride values (p = 0.047), (iii) subject’s age at the time of the ST grouped by numerical order (p = 0.001). Considering that the quality of ST can be assessed by levels of sweat sodium and sweat chloride, an increasing number of low-quality tests could be observed in our sweat samples. The quality of the test was associated with important factors, such as gender, CF diagnosis, and subjects’ age.


  • Open Access

    Pulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test

    by Carla Cristina Souza Gomez, Maria de Fatima Servidoni, Fernando Augusto de Lima Marson, Paulo Jose Coelho Canavezi, Adriana Mendes Vinagre, Eduardo Tavares Costa, Antonio Fernando Ribeiro, Maria Angela Gonçalves de Oliveira Ribeiro, Adyleia Aparecida Dalbo Contrera Toro, Celia Regina Pavan, et al.

    The classic sweat test (CST) is the golden standard for cystic fibrosis (CF) diagnosis. Then, our aim was compare the production and volume of sweat, and side effects caused by pulsed direct current (PDC) and constant direct current (CDC). To determine the optimal stimulation time (ST) for the sweat collection. To verify the PDC as CF diagnosis option. Prospective study with cross-sectional experimental intervention. Experiment 1 (right arm): PDC and CDC. ST at 10 min and sweat collected at 30 min. Currents of 0.5; 0.75; 1.0 and 1.5 mA and frequencies of 0, 200, 1,000 and 5,000 Hz applied. Experiment 2 (left arm): current of 1.0 mA, ST at 5 and 10 min and sweat collected at 15 and 30 min with frequencies of 0; 200; 1,000 and 5,000 Hz applied Experiments 1 and 2 were performed with current density (CD) from 0.07 to 0.21 mA/cm2. Experiment 3: PDC was used in typical CF patients with two CFTR mutations screened and or with CF diagnosis by rectal biopsy and patients with atypical CF. 48 subjects (79.16% female) with average of 29.54 ± 8.87 years old were enrolled. There was no statistical difference between the interaction of frequency and current in the sweat weight (p = 0.7488). Individually, positive association was achieved between weight sweat and stimulation frequency (p = 0.0088); and current (p = 0.0025). The sweat production was higher for 10 min of stimulation (p = 0.0023). The sweat collection was better for 30 min (p = 0.0019). The skin impedance was not influenced by ST and sweat collection (p > 0.05). The current frequency was inversely associated with the skin impedance (p < 0.0001). The skin temperature measured before stimulation was higher than after (p < 0.0001). In Experiment 3 (29 subjects) the PDC showed better kappa index compared to CDC (0.9218 versus 0.5205, respectively). The performance of the CST with CDC and PDC with CD of 0.14 to 0.21 mA/cm2 showed efficacy in steps of stimulation and collection of sweat, without side effects. The optimal stimulation time and sweat collection were, respectively, 10 and 30 min.