Pulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test
Authors:
- Carla Cristina Souza GomezCGCarla Cristina Souza Gomez
- Maria de Fatima ServidoniMSMaria de Fatima Servidoni
- Fernando Augusto de Lima MarsonFMFernando Augusto de Lima Marson
- Paulo Jose Coelho CanaveziPCPaulo Jose Coelho Canavezi
- Adriana Mendes VinagreAVAdriana Mendes Vinagre
- Eduardo Tavares CostaECEduardo Tavares Costa
- Antonio Fernando RibeiroARAntonio Fernando Ribeiro
- Maria Angela Gonçalves de Oliveira RibeiroMRMaria Angela Gonçalves de Oliveira Ribeiro
- Adyleia Aparecida Dalbo Contrera ToroATAdyleia Aparecida Dalbo Contrera Toro
- Celia Regina PavanCPCelia Regina Pavan
- Michelle Vivine Sá dos Santos RondonMRMichelle Vivine Sá dos Santos Rondon
- Sonia Leticia Silva LorenaSLSonia Leticia Silva Lorena
Open Access
- 13 December 2014
- journal article
- research article
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 14 (1) , 198
Abstract
The classic sweat test (CST) is the golden standard for cystic fibrosis (CF) diagnosis. Then, our aim was compare the production and volume of sweat, and side effects caused by pulsed direct current (PDC) and constant direct current (CDC). To determine the optimal stimulation time (ST) for the sweat collection. To verify the PDC as CF diagnosis option. Prospective study with cross-sectional experimental intervention. Experiment 1 (right arm): PDC and CDC. ST at 10 min and sweat collected at 30 min. Currents of 0.5; 0.75; 1.0 and 1.5 mA and frequencies of 0, 200, 1,000 and 5,000 Hz applied. Experiment 2 (left arm): current of 1.0 mA, ST at 5 and 10 min and sweat collected at 15 and 30 min with frequencies of 0; 200; 1,000 and 5,000 Hz applied Experiments 1 and 2 were performed with current density (CD) from 0.07 to 0.21 mA/cm2. Experiment 3: PDC was used in typical CF patients with two CFTR mutations screened and or with CF diagnosis by rectal biopsy and patients with atypical CF. 48 subjects (79.16% female) with average of 29.54 ± 8.87 years old were enrolled. There was no statistical difference between the interaction of frequency and current in the sweat weight (p = 0.7488). Individually, positive association was achieved between weight sweat and stimulation frequency (p = 0.0088); and current (p = 0.0025). The sweat production was higher for 10 min of stimulation (p = 0.0023). The sweat collection was better for 30 min (p = 0.0019). The skin impedance was not influenced by ST and sweat collection (p > 0.05). The current frequency was inversely associated with the skin impedance (p < 0.0001). The skin temperature measured before stimulation was higher than after (p < 0.0001). In Experiment 3 (29 subjects) the PDC showed better kappa index compared to CDC (0.9218 versus 0.5205, respectively). The performance of the CST with CDC and PDC with CD of 0.14 to 0.21 mA/cm2 showed efficacy in steps of stimulation and collection of sweat, without side effects. The optimal stimulation time and sweat collection were, respectively, 10 and 30 min.Keywords
This publication has 55 references indexed in Scilit:
- Saliva as a potential tool for cystic fibrosis diagnosisDiagnostic Pathology, 2013
- Measurements of CFTR-Mediated Cl− Secretion in Human Rectal Biopsies Constitute a Robust Biomarker for Cystic Fibrosis Diagnosis and PrognosisPLOS ONE, 2012
- Guidelines for Diagnosis of Cystic Fibrosis in Newborns through Older Adults: Cystic Fibrosis Foundation Consensus ReportThe Journal of Pediatrics, 2008
- Cystic FibrosisNew England Journal of Medicine, 2005
- The diagnosis of cystic fibrosis: A consensus statementThe Journal of Pediatrics, 1998
- Sweat testing for the diagnosis of cystic fibrosis: Practical considerationsThe Journal of Pediatrics, 1996
- Infiltration versus Okklusionsiontophorese bei Epikondylopathie - eine VergleichsstudiePhysikalische Medizin, Rehabilitationsmedizin, Kurortmedizin, 1996
- Clinical evaluation of the macroduct sweat collection system and conductivity analyzer in the diagnosis of cystic fibrosisThe Journal of Pediatrics, 1994
- In vitro pulsatile and continuous transdermal delivery of buserelin by iontophoresisJournal of Controlled Release, 1993
- Assessment of chronic pain. I. Aspects of the reliability and validity of the visual analogue scalePain, 1983