Berry M. VAN Gelder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Berry M. VAN Gelder has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Frank A. Bracke
Department of Cardiology, Catharina Hospital, Eindhoven, the Netherlands
19 shared publicationsAlbert Meijer
Department of Cardiology, Catharina Hospital, Eindhoven, the Netherlands
14 shared publicationsF. A. L. E. Bracke
Department of Electrophysiology, Catharina Hospital, Eindhoven, The Netherlands
4 shared publicationsB. ter Burg
Department of Electrophysiology, Catharina Hospital, Eindhoven, The Netherlands
2 shared publicationsJ. Schroemges
Department of Electrophysiology, Catharina Hospital, Eindhoven, The Netherlands
2 shared publicationsMike G. Scheffer
Department of Cardiology, Reinier de Graaf Gasthuis, 2600GA Delft, The Netherlands Department of Cardiology, HAGA Hospital, 2545CH The Hague, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 26 June 2018
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 26 (7-8) , 409-410
What is the cause of P-wave undersensing in this CRT-D device?
- 26 June 2018
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 26 (7-8) , 409-410
Open AccessWhat is the cause of P-wave undersensing in this CRT-D device?
- Open Access
- 25 June 2018
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 26 (7-8) , 413-414
What is the cause of P‑wave undersensing in this CRT-D device?
- 25 June 2018
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 26 (7-8) , 413-414
Open AccessWhat is the cause of P‑wave undersensing in this CRT-D device?
- Open Access
- 17 May 2017
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 25 (11) , 647-648
Appropriate or inappropriate ICD shock; what is the post-shock rhythm?
- 17 May 2017
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 25 (11) , 647-648
Open AccessAppropriate or inappropriate ICD shock; what is the post-shock rhythm?
- Open Access
- 17 May 2017
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 25 (11) , 643-644
Appropriate or inappropriate ICD shock; what is the post-shock rhythm?
- 17 May 2017
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 25 (11) , 643-644
Open AccessAppropriate or inappropriate ICD shock; what is the post-shock rhythm?
- 2 June 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (12) , euw054-1778
Late asymptomatic atrial lead perforation, a fortuitous finding during lead extraction using thoracoscopic surveillance: a case report and review of the literature
A 61-year-old male patient was referred for lead extraction of an infected two-chamber pacemaker system first implanted 18 years ago. A new atrial lead was implanted 9 years later because of loss of capture of the original lead. Video-assisted thoracoscopic surgery (VATS) that we use in high-risk cases showed extensive fibrous adhesion between the right atrium wall and the right lung. Dissection of the adhesion revealed the presence of an atrial lead perforated into the lung. After cutting off the lead tip, the residual lead was removed endovascularly from the subclavian site. A literature review of 25 reported cases of late atrial lead perforation was added to the findings in our case report.
- 2 June 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (12) , euw054-1778
Late asymptomatic atrial lead perforation, a fortuitous finding during lead extraction using thoracoscopic surveillance: a case report and review of the literature
A 61-year-old male patient was referred for lead extraction of an infected two-chamber pacemaker system first implanted 18 years ago. A new atrial lead was implanted 9 years later because of loss of capture of the original lead. Video-assisted thoracoscopic surgery (VATS) that we use in high-risk cases showed extensive fibrous adhesion between the right atrium wall and the right lung. Dissection of the adhesion revealed the presence of an atrial lead perforated into the lung. After cutting off the lead tip, the residual lead was removed endovascularly from the subclavian site. A literature review of 25 reported cases of late atrial lead perforation was added to the findings in our case report.
- Open Access
- 8 December 2015
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 24 (1) , 85-92
Haemodynamic evaluation of alternative left ventricular endocardial pacing sites in clinical non-responders to cardiac resynchronisation therapy
Introduction Non response to cardiac resynchronisation therapy (CRT) may be related to the position of the coronary sinus lead. Methods We studied the acute haemodynamic response (AHR) from alternative left ventricular (LV) endocardial pacing sites in clinical non-responders to CRT. AHR and the interval from QRS onset to LV sensing (Q-LV interval) from four different endocardial pacing sites were evaluated in 24 clinical non-responders. A rise in LVdP/dtmax ≥ 15 % from baseline was considered a positive AHR. We also compared the AHR from endocardial with the corresponding epicardial lead position. Results The implanted system showed an AHR ≥ 15 % in 5 patients. In 9 of the 19 remaining patients, AHR could be elevated to ≥ 15 % by endocardial LV pacing. The optimal endocardial pacing site was posterolateral. There was no significant difference in AHR between the epicardial and the corresponding endocardial position. The longest Q-LV interval corresponded with the best AHR in 12 out of the 14 patients with a positive AHR, with an average Q-LV/QRS width ratio of 90 %. Conclusions Acute haemodynamic testing may indicate an alternative endocardial pacing site with a positive AHR in clinical non-responders. The Q-LV interval is a strongly correlated with the optimal endocardial pacing site. Endocardial pacing opposite epicardial sites does not result in a better AHR.
- 8 December 2015
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 24 (1) , 85-92
Open AccessHaemodynamic evaluation of alternative left ventricular endocardial pacing sites in clinical non-responders to cardiac resynchronisation therapy
Introduction Non response to cardiac resynchronisation therapy (CRT) may be related to the position of the coronary sinus lead. Methods We studied the acute haemodynamic response (AHR) from alternative left ventricular (LV) endocardial pacing sites in clinical non-responders to CRT. AHR and the interval from QRS onset to LV sensing (Q-LV interval) from four different endocardial pacing sites were evaluated in 24 clinical non-responders. A rise in LVdP/dtmax ≥ 15 % from baseline was considered a positive AHR. We also compared the AHR from endocardial with the corresponding epicardial lead position. Results The implanted system showed an AHR ≥ 15 % in 5 patients. In 9 of the 19 remaining patients, AHR could be elevated to ≥ 15 % by endocardial LV pacing. The optimal endocardial pacing site was posterolateral. There was no significant difference in AHR between the epicardial and the corresponding endocardial position. The longest Q-LV interval corresponded with the best AHR in 12 out of the 14 patients with a positive AHR, with an average Q-LV/QRS width ratio of 90 %. Conclusions Acute haemodynamic testing may indicate an alternative endocardial pacing site with a positive AHR in clinical non-responders. The Q-LV interval is a strongly correlated with the optimal endocardial pacing site. Endocardial pacing opposite epicardial sites does not result in a better AHR.
- 1 March 2015
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 38 (5) , 558-564
Acute Hemodynamic Effects of Single‐ and Dual‐Site Left Ventricular Pacing Employing a Dual Cathodal Coronary Sinus Lead
Background: We studied the acute hemodynamic effect of left ventricular (LV) pacing from a dual cathodal coronary sinus (CS) lead in a both single‐ and dual‐site electrode configuration.Methods: In 17 patients who underwent implantation of a cardiac resynchronization therapy‐defibrillator system with dual cathodal CS leads, LV stimulation was performed from the distal and proximal electrode separately and from both electrodes simultaneously. The acute hemodynamic response was evaluated by invasive measurement of LVdP/dtmax. Timing of LV electrical activation time measured from onset QRS to LV sense during intrinsic rhythm at both electrodes were determined from simultaneous intracardiac recordings. The latter results were compared to those of an additional group of 26 patients in whom no hemodynamic effects were evaluated.Results: Baseline LVdP/dtmax was 897 ± 222 mm Hg/s. Single‐site LV pacing resulted in a rise of LVdP/dtmax to 1,053 ± 266 mm Hg/s (+17.4%) taking the best of the two sites and 1,020 ± 254 mm Hg (+13.7%) at the worst site (P = 0.0001). In the dual‐site pacing configuration LVdP/dtmax was 1,026 ± 243 mm Hg/s (+14.1%). P value for single best versus dual site was 0.005, and for dual site versus worst single site was 0.18 (n.s.).Conclusion: Even with a relatively small distance of 20–21 mm between stimulation electrodes, there is a significant difference in acute hemodynamic effect from the single best and worst site. Dual‐site LV pacing offers no hemodynamic benefit over the best single pacing site. The short electrode distance may have been a limitation and results may not be applicable to other forms of multisite pacing.
- 1 March 2015
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 38 (5) , 558-564
Acute Hemodynamic Effects of Single‐ and Dual‐Site Left Ventricular Pacing Employing a Dual Cathodal Coronary Sinus Lead
Background: We studied the acute hemodynamic effect of left ventricular (LV) pacing from a dual cathodal coronary sinus (CS) lead in a both single‐ and dual‐site electrode configuration.Methods: In 17 patients who underwent implantation of a cardiac resynchronization therapy‐defibrillator system with dual cathodal CS leads, LV stimulation was performed from the distal and proximal electrode separately and from both electrodes simultaneously. The acute hemodynamic response was evaluated by invasive measurement of LVdP/dtmax. Timing of LV electrical activation time measured from onset QRS to LV sense during intrinsic rhythm at both electrodes were determined from simultaneous intracardiac recordings. The latter results were compared to those of an additional group of 26 patients in whom no hemodynamic effects were evaluated.Results: Baseline LVdP/dtmax was 897 ± 222 mm Hg/s. Single‐site LV pacing resulted in a rise of LVdP/dtmax to 1,053 ± 266 mm Hg/s (+17.4%) taking the best of the two sites and 1,020 ± 254 mm Hg (+13.7%) at the worst site (P = 0.0001). In the dual‐site pacing configuration LVdP/dtmax was 1,026 ± 243 mm Hg/s (+14.1%). P value for single best versus dual site was 0.005, and for dual site versus worst single site was 0.18 (n.s.).Conclusion: Even with a relatively small distance of 20–21 mm between stimulation electrodes, there is a significant difference in acute hemodynamic effect from the single best and worst site. Dual‐site LV pacing offers no hemodynamic benefit over the best single pacing site. The short electrode distance may have been a limitation and results may not be applicable to other forms of multisite pacing.
- Open Access
- 30 January 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (10) , 1520
Left Ventricular endocardial pacing by the interventricular septum route
A 75 years old female patient with heart failure (HF) had a cardiac resynchronisation therapy pacemaker device implanted but developed untreatable phrenic nerve stimulation and recurrence of HF after disabling left ventricular (LV) pacing. She agreed with implantation of an LV endocardial lead using an approach through the interventricular septum. A coronary angiogram was performed to be informed about the size and position of septal branches. A deflectable 12F St Jude Medical Agilis 408310 sheath was advanced into the right ventricle towards the interventricular septum. The dilator of the Agilis sheath was advanced to the septum but penetrated without applying noticeable force. The position was confirmed by fluoroscopy, intra cardiac echo, and LV cavity pressure. (left panel) The Agilis sheath was changed for a Medtronic Attain deflectable coronary sinus catheter through which a Medtronic SelectSecure 3830 was implanted in the LV posterolateral area. After checking pacing and sensing parameters, lead stability and proper fixation, the Attain catheter was slit and removed. The lead was provided with ample slack in the LV (right panel). After implant, the patient developed pericardial effusion which was relieved by pericardiocentesis. Perforation of the LV lead was excluded by computed tomography scan and electrical parameters. She recovered completely free of HF symptoms.
- 30 January 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (10) , 1520
Open AccessLeft Ventricular endocardial pacing by the interventricular septum route
A 75 years old female patient with heart failure (HF) had a cardiac resynchronisation therapy pacemaker device implanted but developed untreatable phrenic nerve stimulation and recurrence of HF after disabling left ventricular (LV) pacing. She agreed with implantation of an LV endocardial lead using an approach through the interventricular septum. A coronary angiogram was performed to be informed about the size and position of septal branches. A deflectable 12F St Jude Medical Agilis 408310 sheath was advanced into the right ventricle towards the interventricular septum. The dilator of the Agilis sheath was advanced to the septum but penetrated without applying noticeable force. The position was confirmed by fluoroscopy, intra cardiac echo, and LV cavity pressure. (left panel) The Agilis sheath was changed for a Medtronic Attain deflectable coronary sinus catheter through which a Medtronic SelectSecure 3830 was implanted in the LV posterolateral area. After checking pacing and sensing parameters, lead stability and proper fixation, the Attain catheter was slit and removed. The lead was provided with ample slack in the LV (right panel). After implant, the patient developed pericardial effusion which was relieved by pericardiocentesis. Perforation of the LV lead was excluded by computed tomography scan and electrical parameters. She recovered completely free of HF symptoms.
- Open Access
- 20 June 2012
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 14 (12) , 1758
Decrease of the right ventricular electrogram amplitude in a Sprint Fidelis shock lead: a sign of lead malfunction?
A 76-year-old male had dual-chamber implantable cardioverter defibrillatorimplanted, employing a Medtronic Sprint Fidelis 6931-65 shock. A routine follow-up 4 years later showed a sudden steep decrease in the amplitude of the right ventricular electrogram (EGM) from 9.0 to 2.0 mV (Panel A). Because of the known high failure rate related to the Sprint Fidelis shock lead, we initially focused on markers of lead failure by recordings of the intracardiac EGM, changes in lead impedance, and/or radiographic abnormalities. However, in none of these parameters any abnormality was observed. Lead impedance trend was completely stable at the time the decrease in EGM amplitude was observed.
- 20 June 2012
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 14 (12) , 1758
Open AccessDecrease of the right ventricular electrogram amplitude in a Sprint Fidelis shock lead: a sign of lead malfunction?
A 76-year-old male had dual-chamber implantable cardioverter defibrillatorimplanted, employing a Medtronic Sprint Fidelis 6931-65 shock. A routine follow-up 4 years later showed a sudden steep decrease in the amplitude of the right ventricular electrogram (EGM) from 9.0 to 2.0 mV (Panel A). Because of the known high failure rate related to the Sprint Fidelis shock lead, we initially focused on markers of lead failure by recordings of the intracardiac EGM, changes in lead impedance, and/or radiographic abnormalities. However, in none of these parameters any abnormality was observed. Lead impedance trend was completely stable at the time the decrease in EGM amplitude was observed.