Dan Fu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dan Fu has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Xingtao Zhou
Eye Institute and Department of Ophthalmology Eye & ENT Hospital, Fudan University Shanghai China
5 shared publications - Jing Zhao
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
3 shared publications - Ruoyan Wei
Department of Ophthalmology, Eye and ENT Hospital of Fudan University, Shanghai, China
2 shared publications - Bing Qin
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
1 shared publication - Dong Yang
Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia (Fudan University), Shanghai, China; Shanghai Research Center of Ophthalmology and Optometry
1 shared publication - Fei Xia
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Fudan, China
1 shared publication
Latest Publications
- 1 January 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (1) , 86-92
Hyperopic keratorefractive lenticule extraction
Keratorefractive lenticule extraction (KLEx) is a cutting-edge refractive surgery technique that has garnered considerable attention in recent years due to its minimally invasive nature and the absence of a corneal flap both of which are notable advantages over traditional laser-assisted in situ keratomileusis surgery. Currently, the technology for myopia correction using KLEx has been refined and is widely recognized. Consequently, hyperopic KLEx surgery is highly anticipated, having undergone nearly a decade of evolution and development, and it seems to have finally achieved stable and reliable postoperative outcomes. This article reviews the emerging hyperopic KLEx in clinical outcomes, challenges, complications, and outlook.
- 1 January 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (1) , 86-92
Hyperopic keratorefractive lenticule extraction
Keratorefractive lenticule extraction (KLEx) is a cutting-edge refractive surgery technique that has garnered considerable attention in recent years due to its minimally invasive nature and the absence of a corneal flap both of which are notable advantages over traditional laser-assisted in situ keratomileusis surgery. Currently, the technology for myopia correction using KLEx has been refined and is widely recognized. Consequently, hyperopic KLEx surgery is highly anticipated, having undergone nearly a decade of evolution and development, and it seems to have finally achieved stable and reliable postoperative outcomes. This article reviews the emerging hyperopic KLEx in clinical outcomes, challenges, complications, and outlook.
- Open Access
- 26 April 2023
- Published by Wolters Kluwer Health in Cornea
- Vol. 42 (12) , 1506-1512
Comparison of Visual Outcomes and Higher-order Aberrations Between FS-LASIK and SMI-LIKE for Moderate to High Hyperopia: A 2-Year Result
Purpose: The aim of the study was to evaluate and compare the long-term visual outcomes and higher-order aberrations (HOAs) between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule intrastromal keratoplasty (SMI-LIKE) in the correction of moderate to high hyperopia. Methods: In this study, 16 subjects (20 eyes) underwent FS-LASIK and 7 subjects (10 eyes) underwent SMI-LIKE. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, mean keratometry (Km), anterior asphericity (Q), and HOAs preoperatively and 2 years postoperatively were obtained in both procedures. Results: The efficacy indices of the FS-LASIK group and the SMI-LIKE group were 0.85 ± 0.14 and 0.87 ± 0.17, respectively. The safety indices of the FS-LASIK and SMI-LIKE groups were 0.99 ± 0.15 and 1.08 ± 0.24, respectively. No significant difference in safety index or efficacy index was found between the FS-LASIK and SMI-LIKE groups (all P > 0.05). The correlation coefficient of the attempted versus achieved spherical equivalent postoperatively was 0.69 (P < 0.01) and 0.89 (P < 0.01) in the FS-LASIK group and SMI-LIKE groups, respectively. The front Km, negative Q value, negative spherical aberrations (SAs), coma, and total HOAs significantly increased postoperatively in the 2 groups (P < 0.05). The FS-LASIK group had greater changes in Q value and SA postoperatively than the SMI-LIKE group (P < 0.01). Conclusions: SMI-LIKE had similar safety and efficacy to FS-LASIK in the correction of moderate to high hyperopia. However, SMI-LIKE may equip better visual quality postoperatively for its lower Q value and SA changes than FS-LASIK.
- 26 April 2023
- Published by Wolters Kluwer Health in Cornea
- Vol. 42 (12) , 1506-1512
Open AccessComparison of Visual Outcomes and Higher-order Aberrations Between FS-LASIK and SMI-LIKE for Moderate to High Hyperopia: A 2-Year Result
Purpose: The aim of the study was to evaluate and compare the long-term visual outcomes and higher-order aberrations (HOAs) between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule intrastromal keratoplasty (SMI-LIKE) in the correction of moderate to high hyperopia. Methods: In this study, 16 subjects (20 eyes) underwent FS-LASIK and 7 subjects (10 eyes) underwent SMI-LIKE. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, mean keratometry (Km), anterior asphericity (Q), and HOAs preoperatively and 2 years postoperatively were obtained in both procedures. Results: The efficacy indices of the FS-LASIK group and the SMI-LIKE group were 0.85 ± 0.14 and 0.87 ± 0.17, respectively. The safety indices of the FS-LASIK and SMI-LIKE groups were 0.99 ± 0.15 and 1.08 ± 0.24, respectively. No significant difference in safety index or efficacy index was found between the FS-LASIK and SMI-LIKE groups (all P > 0.05). The correlation coefficient of the attempted versus achieved spherical equivalent postoperatively was 0.69 (P < 0.01) and 0.89 (P < 0.01) in the FS-LASIK group and SMI-LIKE groups, respectively. The front Km, negative Q value, negative spherical aberrations (SAs), coma, and total HOAs significantly increased postoperatively in the 2 groups (P < 0.05). The FS-LASIK group had greater changes in Q value and SA postoperatively than the SMI-LIKE group (P < 0.01). Conclusions: SMI-LIKE had similar safety and efficacy to FS-LASIK in the correction of moderate to high hyperopia. However, SMI-LIKE may equip better visual quality postoperatively for its lower Q value and SA changes than FS-LASIK.
- Open Access
- 27 September 2021
- Published by Wolters Kluwer Health in Cornea
- Vol. 41 (4) , 470-477
Comparison of the Effects of Temperature and Dehydration Mode on Glycerin-Based Approaches to SMILE-Derived Lenticule Preservation
Purpose: The aim of this study was to explore the optimal method of small-incision lenticule extraction (SMILE)-derived lenticules, subjected to long-term preservation using glycerol, under a range of temperatures, and using an array of dehydration agents. Methods: In total, 108 myopic lenticules were collected from patients undergoing the SMILE procedure. Fresh lenticules served as a control group for this study, whereas all other lenticules were separated into 8 groups, which were preserved at 4 different temperatures (room temperature [RT], 4, −20, and −80°C) with or without silica gel in anhydrous glycerol. Evaluated parameters included thickness, transmittance, hematoxylin and eosin staining, transmission electron microscopy, and immunohistochemistry analyses. Results: After a 3-month preservation period, lenticular thickness in these different groups was significantly increased, particularly for samples stored at RT. The mean percentage transmittance of lenticules stored at −80°C with or without silica gel was closest to that of fresh lenticules. Hematoxylin and eosin staining revealed sparsely arranged collagen fibers that were more scattered in preserved lenticules relative to fresh lenticules, particularly in RT samples. Transmission electron microscopy revealed that the fibril bundles densities in lenticules stored at RT were significantly less than those stored at other temperatures. Immunohistochemistry analyses revealed reductions in or loss of CD45 and human leukocyte antigens in all preserved lenticules relative to control samples. Conclusions: Of the tested approaches, the preservation of SMILE-derived lenticules over a 3-month period was optimal at −80°C with or without silica gel in anhydrous glycerol.
- 27 September 2021
- Published by Wolters Kluwer Health in Cornea
- Vol. 41 (4) , 470-477
Open AccessComparison of the Effects of Temperature and Dehydration Mode on Glycerin-Based Approaches to SMILE-Derived Lenticule Preservation
Purpose: The aim of this study was to explore the optimal method of small-incision lenticule extraction (SMILE)-derived lenticules, subjected to long-term preservation using glycerol, under a range of temperatures, and using an array of dehydration agents. Methods: In total, 108 myopic lenticules were collected from patients undergoing the SMILE procedure. Fresh lenticules served as a control group for this study, whereas all other lenticules were separated into 8 groups, which were preserved at 4 different temperatures (room temperature [RT], 4, −20, and −80°C) with or without silica gel in anhydrous glycerol. Evaluated parameters included thickness, transmittance, hematoxylin and eosin staining, transmission electron microscopy, and immunohistochemistry analyses. Results: After a 3-month preservation period, lenticular thickness in these different groups was significantly increased, particularly for samples stored at RT. The mean percentage transmittance of lenticules stored at −80°C with or without silica gel was closest to that of fresh lenticules. Hematoxylin and eosin staining revealed sparsely arranged collagen fibers that were more scattered in preserved lenticules relative to fresh lenticules, particularly in RT samples. Transmission electron microscopy revealed that the fibril bundles densities in lenticules stored at RT were significantly less than those stored at other temperatures. Immunohistochemistry analyses revealed reductions in or loss of CD45 and human leukocyte antigens in all preserved lenticules relative to control samples. Conclusions: Of the tested approaches, the preservation of SMILE-derived lenticules over a 3-month period was optimal at −80°C with or without silica gel in anhydrous glycerol.
- Open Access
- 8 August 2019
- Published by Springer Nature in BMC Ophthalmology
- Vol. 19 (1) , 1-5
Two-year outcome of an eye that underwent hyperopic LASIK following inadvertent myopic SMILE lenticule in situ implantation
This report describes a case in which hyperopic femtosecond laser-assisted in situ keratomileusis (FS-LASIK) was performed following small incision lenticule extraction (SMILE) lenticule in situ implantation. The hyperopic left eye of a 46-year-old patient with refraction of + 7.75 diopters sphere (DS)/− 1.25 diopters cylinder (DC) × 5° and corrected distance visual acuity (CDVA) of 20/50 mistakenly underwent the SMILE procedure for myopic astigmatism (− 8.50 DS/− 1.50 DC × 175°) due to medical negligence. The extracted lenticule was subsequently re-implanted in situ. After 8 months, the left eye underwent FS-LASIK to correct hyperopia and astigmatism (+ 5.0 DS/− 0.75 DC × 100°). Two years after FS-LASIK, corneal tomography showed no ectasia and microscopy revealed transparent cornea. The left eye exhibited CDVA of 20/50 with refraction of − 0.75 DS/− 0.25 DC × 165°. SMILE lenticule in situ implantation offers a solution for corneal volume and thickness restoration. FS-LASIK provides feasible correction of refractive error following lenticule re-implantation. Future studies are needed for determining the effectiveness of the treatment.
- 8 August 2019
- Published by Springer Nature in BMC Ophthalmology
- Vol. 19 (1) , 1-5
Open AccessTwo-year outcome of an eye that underwent hyperopic LASIK following inadvertent myopic SMILE lenticule in situ implantation
This report describes a case in which hyperopic femtosecond laser-assisted in situ keratomileusis (FS-LASIK) was performed following small incision lenticule extraction (SMILE) lenticule in situ implantation. The hyperopic left eye of a 46-year-old patient with refraction of + 7.75 diopters sphere (DS)/− 1.25 diopters cylinder (DC) × 5° and corrected distance visual acuity (CDVA) of 20/50 mistakenly underwent the SMILE procedure for myopic astigmatism (− 8.50 DS/− 1.50 DC × 175°) due to medical negligence. The extracted lenticule was subsequently re-implanted in situ. After 8 months, the left eye underwent FS-LASIK to correct hyperopia and astigmatism (+ 5.0 DS/− 0.75 DC × 100°). Two years after FS-LASIK, corneal tomography showed no ectasia and microscopy revealed transparent cornea. The left eye exhibited CDVA of 20/50 with refraction of − 0.75 DS/− 0.25 DC × 165°. SMILE lenticule in situ implantation offers a solution for corneal volume and thickness restoration. FS-LASIK provides feasible correction of refractive error following lenticule re-implantation. Future studies are needed for determining the effectiveness of the treatment.
- Open Access
- 31 May 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 131
Safety and satisfaction of myopic small-incision lenticule extraction combined with monovision
To investigate the safety and optical quality of small-incision lenticule extraction (SMILE) combined with monovision, and patient satisfaction with the procedure. The present study assessed a non-random case series involving 60 eyes of 30 patients (mean age 45.53 ± 3.20 years [range 41 to 52 years]) treated bilaterally using the VisuMax 500 system (Carl Zeiss Meditec, Jena, Germany) between January and July 2016. The target refraction was plano for the distance eye, and between − 0.5 and − 1.75 diopters (D) for the near eye. Visual acuity, refraction errors, ocular aberrations, and satisfaction questionnaire scores were calculated 1 year after surgery. All surgeries were uneventful, with a mean safety index of 1.03 and 1.04 in dominant and nondominant eyes, respectively. Binocular uncorrected distance visual acuity of all patients was ≥20/32, while binocular uncorrected near visual acuity was ≥20/40 1 year postoperatively. Higher-order aberration (0.45 ± 0.14, 0.51 ± 0.15 μm), spherical (0.18 ± 0.15, 0.21 ± 0.14 μm) and coma aberration (0.31 ± 0.16, 0.27 ± 0.17 μm) were identical between dominant and nondominant eyes after surgery. The overall satisfaction rate was 86.7% (26/30), with large contributions from age (OR = 1.76 95% CI: 1.03–2.53; P = 0.036). Binocular uncorrected distance visual acuity was related to preoperative spherical diopter (r = − 0.500; P = 0.005). Monovision appears to be a safe and effective option for myopia patients with presbyopia who are considering the SMILE procedure. Patients with younger age were more satisfied with the procedure.
- 31 May 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 131
Open AccessSafety and satisfaction of myopic small-incision lenticule extraction combined with monovision
To investigate the safety and optical quality of small-incision lenticule extraction (SMILE) combined with monovision, and patient satisfaction with the procedure. The present study assessed a non-random case series involving 60 eyes of 30 patients (mean age 45.53 ± 3.20 years [range 41 to 52 years]) treated bilaterally using the VisuMax 500 system (Carl Zeiss Meditec, Jena, Germany) between January and July 2016. The target refraction was plano for the distance eye, and between − 0.5 and − 1.75 diopters (D) for the near eye. Visual acuity, refraction errors, ocular aberrations, and satisfaction questionnaire scores were calculated 1 year after surgery. All surgeries were uneventful, with a mean safety index of 1.03 and 1.04 in dominant and nondominant eyes, respectively. Binocular uncorrected distance visual acuity of all patients was ≥20/32, while binocular uncorrected near visual acuity was ≥20/40 1 year postoperatively. Higher-order aberration (0.45 ± 0.14, 0.51 ± 0.15 μm), spherical (0.18 ± 0.15, 0.21 ± 0.14 μm) and coma aberration (0.31 ± 0.16, 0.27 ± 0.17 μm) were identical between dominant and nondominant eyes after surgery. The overall satisfaction rate was 86.7% (26/30), with large contributions from age (OR = 1.76 95% CI: 1.03–2.53; P = 0.036). Binocular uncorrected distance visual acuity was related to preoperative spherical diopter (r = − 0.500; P = 0.005). Monovision appears to be a safe and effective option for myopia patients with presbyopia who are considering the SMILE procedure. Patients with younger age were more satisfied with the procedure.