Jing Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jing Zhao has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Xingtao Zhou
Eye Institute and Department of Ophthalmology Eye & ENT Hospital, Fudan University Shanghai China
6 shared publications - Dan Fu
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
3 shared publications - Yang Shen
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200031, China
3 shared publications - Haipeng Xu
Department of Ophthalmology, Eye and ENT Hospital of Fudan University, NHC Key Laboratory of Myopia, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
2 shared publications - Xiaoyu Zhang
Department of Ophthalmology, Eye and ENT Hospital of Fudan University, Myopia Key Laboratory of The Health Ministry Shanghai, China
2 shared publications - Yu Zhao
Department of Ophthalmology, Eye and ENT Hospital of Fudan University, NHC Key Laboratory of Myopia, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 28 April 2023
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 49 (6) , 224-233
Characteristics and Related Parameters of Quick Contrast Sensitivity Function in Chinese Ametropia Children
Purpose: To investigate the characteristics of quick contrast sensitivity function (qCSF) and its related parameters in Chinese ametropia children. Methods: This case series study enrolled 106 eyes of 53 children (male/female=29/24, age: 9.04±2.06 years). Examinations included manifest refraction, axial length, corneal curvature, and monocular and binocular qCSF readings without refractive correction (area under log CSF [AULCSF], CSF acuity, and contrast sensitivity [CS] at 1.0 to 18.0 cpd). The subjects were divided into groups according to age and refractive parameters for analysis. Results: The mean spherical equivalent (SE), AULCSF, and CSF acuity of the test eyes were −0.94±1.53 D, 0.44±0.33, and 8.50±5.97 cpd, respectively. In the monocular qCSF comparison, the refraction sphere (RS) was the major factor correlated with qCSF readings (B=0.186, P=0.009 for AULCSF; B=0.543, P=0.019 for CSF acuity; generalized linear model). The three groups stratified by RS/SE (<−1.00D, −1.00D to 0D, and >0D) showed significant differences in CS at medium spatial frequencies (3.0 and 6.0 cpd; all PPP<0.05). Conclusion: RS and SE are the major contributing factors of qCSF without refractive correction in children. The CS at medium spatial frequencies decrease significantly as the RS/SE increase. In low myopia children, the CS at medium and high spatial frequencies are significantly decreased, providing practical value in visual function screening in children.
- 28 April 2023
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 49 (6) , 224-233
Open AccessCharacteristics and Related Parameters of Quick Contrast Sensitivity Function in Chinese Ametropia Children
Purpose: To investigate the characteristics of quick contrast sensitivity function (qCSF) and its related parameters in Chinese ametropia children. Methods: This case series study enrolled 106 eyes of 53 children (male/female=29/24, age: 9.04±2.06 years). Examinations included manifest refraction, axial length, corneal curvature, and monocular and binocular qCSF readings without refractive correction (area under log CSF [AULCSF], CSF acuity, and contrast sensitivity [CS] at 1.0 to 18.0 cpd). The subjects were divided into groups according to age and refractive parameters for analysis. Results: The mean spherical equivalent (SE), AULCSF, and CSF acuity of the test eyes were −0.94±1.53 D, 0.44±0.33, and 8.50±5.97 cpd, respectively. In the monocular qCSF comparison, the refraction sphere (RS) was the major factor correlated with qCSF readings (B=0.186, P=0.009 for AULCSF; B=0.543, P=0.019 for CSF acuity; generalized linear model). The three groups stratified by RS/SE (<−1.00D, −1.00D to 0D, and >0D) showed significant differences in CS at medium spatial frequencies (3.0 and 6.0 cpd; all PPP<0.05). Conclusion: RS and SE are the major contributing factors of qCSF without refractive correction in children. The CS at medium spatial frequencies decrease significantly as the RS/SE increase. In low myopia children, the CS at medium and high spatial frequencies are significantly decreased, providing practical value in visual function screening in children.
- Open Access
- 27 September 2021
- Published by Wolters Kluwer Health in Cornea
- Vol. 41 (4) , 470-477
Comparison of the Effects of Temperature and Dehydration Mode on Glycerin-Based Approaches to SMILE-Derived Lenticule Preservation
Purpose: The aim of this study was to explore the optimal method of small-incision lenticule extraction (SMILE)-derived lenticules, subjected to long-term preservation using glycerol, under a range of temperatures, and using an array of dehydration agents. Methods: In total, 108 myopic lenticules were collected from patients undergoing the SMILE procedure. Fresh lenticules served as a control group for this study, whereas all other lenticules were separated into 8 groups, which were preserved at 4 different temperatures (room temperature [RT], 4, −20, and −80°C) with or without silica gel in anhydrous glycerol. Evaluated parameters included thickness, transmittance, hematoxylin and eosin staining, transmission electron microscopy, and immunohistochemistry analyses. Results: After a 3-month preservation period, lenticular thickness in these different groups was significantly increased, particularly for samples stored at RT. The mean percentage transmittance of lenticules stored at −80°C with or without silica gel was closest to that of fresh lenticules. Hematoxylin and eosin staining revealed sparsely arranged collagen fibers that were more scattered in preserved lenticules relative to fresh lenticules, particularly in RT samples. Transmission electron microscopy revealed that the fibril bundles densities in lenticules stored at RT were significantly less than those stored at other temperatures. Immunohistochemistry analyses revealed reductions in or loss of CD45 and human leukocyte antigens in all preserved lenticules relative to control samples. Conclusions: Of the tested approaches, the preservation of SMILE-derived lenticules over a 3-month period was optimal at −80°C with or without silica gel in anhydrous glycerol.
- 27 September 2021
- Published by Wolters Kluwer Health in Cornea
- Vol. 41 (4) , 470-477
Open AccessComparison of the Effects of Temperature and Dehydration Mode on Glycerin-Based Approaches to SMILE-Derived Lenticule Preservation
Purpose: The aim of this study was to explore the optimal method of small-incision lenticule extraction (SMILE)-derived lenticules, subjected to long-term preservation using glycerol, under a range of temperatures, and using an array of dehydration agents. Methods: In total, 108 myopic lenticules were collected from patients undergoing the SMILE procedure. Fresh lenticules served as a control group for this study, whereas all other lenticules were separated into 8 groups, which were preserved at 4 different temperatures (room temperature [RT], 4, −20, and −80°C) with or without silica gel in anhydrous glycerol. Evaluated parameters included thickness, transmittance, hematoxylin and eosin staining, transmission electron microscopy, and immunohistochemistry analyses. Results: After a 3-month preservation period, lenticular thickness in these different groups was significantly increased, particularly for samples stored at RT. The mean percentage transmittance of lenticules stored at −80°C with or without silica gel was closest to that of fresh lenticules. Hematoxylin and eosin staining revealed sparsely arranged collagen fibers that were more scattered in preserved lenticules relative to fresh lenticules, particularly in RT samples. Transmission electron microscopy revealed that the fibril bundles densities in lenticules stored at RT were significantly less than those stored at other temperatures. Immunohistochemistry analyses revealed reductions in or loss of CD45 and human leukocyte antigens in all preserved lenticules relative to control samples. Conclusions: Of the tested approaches, the preservation of SMILE-derived lenticules over a 3-month period was optimal at −80°C with or without silica gel in anhydrous glycerol.
- Open Access
- 23 June 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (2) , 208-214
Transepithelial accelerated corneal crosslinking for keratoconus eyes with maximum keratometry values larger than 58 diopters
Purpose: To evaluate the safety and efficacy of transepithelial accelerated corneal crosslinking (CXL) for advanced keratoconus eyes with maximum keratometry (Kmax) values >58 diopters (D). Setting: Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China. Design: Prospective parallel control study. Methods: 41 keratoconus eyes from 41 patients (mean age, 21.93 ± 5.48 years) who underwent transepithelial accelerated CXL were included prospectively. The enrolled eyes were divided into 2 groups according to their Kmax values (Group A, Kmax ≥58.0 D; Group B, Kmax <58.0 D). The examinations including assessment of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), corneal topography, and corneal endothelial cell density count were conducted preoperatively, at 1 day, 1 month, 3 months, 6 months, and 1 year postoperatively. Results: All 41 eyes finished 1 year follow-up. No statistical difference was noted between the mean UDVA and CDVA in both groups throughout the follow-up duration. At 1-year postoperative follow-up, the CDVA increased by ≥2 lines in 45% (9/20) and 28.6% (6/21) eyes in Groups A and B, respectively. The mean preoperative Kmax in Groups A and B were 62.51 ± 3.34 D and 49.98 ± 4.32 D, respectively, and that at postoperative 1-year follow-up were 61.94 ± 4.11 D and 50.24 ± 4.72 D, respectively. The Kmax values of 30% (6/20) eyes in Group A and 4.8% (1/21) eyes in Group B decreased by more than 1 D. Deduction of flat K, steep K, mean K, and Kmax showed no significant difference between the 2 groups at 1-year postoperative follow-up. Moreover, 20% (4/20) and 23.8% (5/21) of eyes in Groups A and B, respectively, showed progress at postoperative 1-year follow-up. Conclusions: Transepithelial accelerated CXL can safely treat advanced keratoconus eyes with Kmax values ≥58.0 D with some extent of efficacy and has similar progressive rate as Kmax values <58.0 D.
- 23 June 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (2) , 208-214
Open AccessTransepithelial accelerated corneal crosslinking for keratoconus eyes with maximum keratometry values larger than 58 diopters
Purpose: To evaluate the safety and efficacy of transepithelial accelerated corneal crosslinking (CXL) for advanced keratoconus eyes with maximum keratometry (Kmax) values >58 diopters (D). Setting: Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China. Design: Prospective parallel control study. Methods: 41 keratoconus eyes from 41 patients (mean age, 21.93 ± 5.48 years) who underwent transepithelial accelerated CXL were included prospectively. The enrolled eyes were divided into 2 groups according to their Kmax values (Group A, Kmax ≥58.0 D; Group B, Kmax <58.0 D). The examinations including assessment of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), corneal topography, and corneal endothelial cell density count were conducted preoperatively, at 1 day, 1 month, 3 months, 6 months, and 1 year postoperatively. Results: All 41 eyes finished 1 year follow-up. No statistical difference was noted between the mean UDVA and CDVA in both groups throughout the follow-up duration. At 1-year postoperative follow-up, the CDVA increased by ≥2 lines in 45% (9/20) and 28.6% (6/21) eyes in Groups A and B, respectively. The mean preoperative Kmax in Groups A and B were 62.51 ± 3.34 D and 49.98 ± 4.32 D, respectively, and that at postoperative 1-year follow-up were 61.94 ± 4.11 D and 50.24 ± 4.72 D, respectively. The Kmax values of 30% (6/20) eyes in Group A and 4.8% (1/21) eyes in Group B decreased by more than 1 D. Deduction of flat K, steep K, mean K, and Kmax showed no significant difference between the 2 groups at 1-year postoperative follow-up. Moreover, 20% (4/20) and 23.8% (5/21) of eyes in Groups A and B, respectively, showed progress at postoperative 1-year follow-up. Conclusions: Transepithelial accelerated CXL can safely treat advanced keratoconus eyes with Kmax values ≥58.0 D with some extent of efficacy and has similar progressive rate as Kmax values <58.0 D.
- 1 March 2020
- Published by Elsevier in Experimental Eye Research
- Vol. 192, 107935
Two-year observation of morphologic and histopathologic changes in the monkey cornea following small incision allogenic lenticule implantation
- 1 March 2020
- Published by Elsevier in Experimental Eye Research
- Vol. 192, 107935
Two-year observation of morphologic and histopathologic changes in the monkey cornea following small incision allogenic lenticule implantation
- 8 January 2020
- Published by Springer Nature in International Ophthalmology
- Vol. 40 (4) , 917-924
Ciliary muscle morphology and accommodative lag in hyperopic anisometropic children
Purpose To investigate the cross-sectional area (CSA) and thickness of the ciliary muscle and their correlation with accommodative lag in hyperopic anisometropic children. Methods Forty children aged between 6 and 10 years with hyperopic anisometropia were recruited. The more hyperopic eye (mean refractive power of 3.51 ± 1.70 D) was compared with the less hyperopic eye (mean refractive power of 0.78 ± 1.41 D). The thickness and CSA of the ciliary muscle were measured with anterior segment optical coherence tomography (OCT) images at four meridians. The differences between the eyes and the correlations between CSA, thickness, axial length and accommodative lag were accessed. Results There was no statistically significant difference in CSA between the two groups at any meridian, except at the inferior meridian (P < 0.05). There was no statistically significant difference in ciliary muscle thickness between eyes at any meridian, except on the temporal and the nasal meridians (P < 0.05). There was a significant difference in the ratio of CSA to axial length at all meridians between the two groups (all P < 0.05). Accommodative lag was 1.65 ± 0.55 D and 0.93 ± 0.45 D in the more and less hyperopic eyes, respectively, which was a statistically significant difference (P < 0.05). There was no significant correlation between the CSA with the axial length and the accommodative lag. Conclusions This study demonstrated a greater degree of accommodative lag in the more hyperopic eye of anisometropic children. There was no correlation among accommodative lag, axial length and CSA of the ciliary muscle with the degree of hyperopia.
- 8 January 2020
- Published by Springer Nature in International Ophthalmology
- Vol. 40 (4) , 917-924
Ciliary muscle morphology and accommodative lag in hyperopic anisometropic children
Purpose To investigate the cross-sectional area (CSA) and thickness of the ciliary muscle and their correlation with accommodative lag in hyperopic anisometropic children. Methods Forty children aged between 6 and 10 years with hyperopic anisometropia were recruited. The more hyperopic eye (mean refractive power of 3.51 ± 1.70 D) was compared with the less hyperopic eye (mean refractive power of 0.78 ± 1.41 D). The thickness and CSA of the ciliary muscle were measured with anterior segment optical coherence tomography (OCT) images at four meridians. The differences between the eyes and the correlations between CSA, thickness, axial length and accommodative lag were accessed. Results There was no statistically significant difference in CSA between the two groups at any meridian, except at the inferior meridian (P < 0.05). There was no statistically significant difference in ciliary muscle thickness between eyes at any meridian, except on the temporal and the nasal meridians (P < 0.05). There was a significant difference in the ratio of CSA to axial length at all meridians between the two groups (all P < 0.05). Accommodative lag was 1.65 ± 0.55 D and 0.93 ± 0.45 D in the more and less hyperopic eyes, respectively, which was a statistically significant difference (P < 0.05). There was no significant correlation between the CSA with the axial length and the accommodative lag. Conclusions This study demonstrated a greater degree of accommodative lag in the more hyperopic eye of anisometropic children. There was no correlation among accommodative lag, axial length and CSA of the ciliary muscle with the degree of hyperopia.
- Open Access
- 8 August 2019
- Published by Springer Nature in BMC Ophthalmology
- Vol. 19 (1) , 1-5
Two-year outcome of an eye that underwent hyperopic LASIK following inadvertent myopic SMILE lenticule in situ implantation
This report describes a case in which hyperopic femtosecond laser-assisted in situ keratomileusis (FS-LASIK) was performed following small incision lenticule extraction (SMILE) lenticule in situ implantation. The hyperopic left eye of a 46-year-old patient with refraction of + 7.75 diopters sphere (DS)/− 1.25 diopters cylinder (DC) × 5° and corrected distance visual acuity (CDVA) of 20/50 mistakenly underwent the SMILE procedure for myopic astigmatism (− 8.50 DS/− 1.50 DC × 175°) due to medical negligence. The extracted lenticule was subsequently re-implanted in situ. After 8 months, the left eye underwent FS-LASIK to correct hyperopia and astigmatism (+ 5.0 DS/− 0.75 DC × 100°). Two years after FS-LASIK, corneal tomography showed no ectasia and microscopy revealed transparent cornea. The left eye exhibited CDVA of 20/50 with refraction of − 0.75 DS/− 0.25 DC × 165°. SMILE lenticule in situ implantation offers a solution for corneal volume and thickness restoration. FS-LASIK provides feasible correction of refractive error following lenticule re-implantation. Future studies are needed for determining the effectiveness of the treatment.
- 8 August 2019
- Published by Springer Nature in BMC Ophthalmology
- Vol. 19 (1) , 1-5
Open AccessTwo-year outcome of an eye that underwent hyperopic LASIK following inadvertent myopic SMILE lenticule in situ implantation
This report describes a case in which hyperopic femtosecond laser-assisted in situ keratomileusis (FS-LASIK) was performed following small incision lenticule extraction (SMILE) lenticule in situ implantation. The hyperopic left eye of a 46-year-old patient with refraction of + 7.75 diopters sphere (DS)/− 1.25 diopters cylinder (DC) × 5° and corrected distance visual acuity (CDVA) of 20/50 mistakenly underwent the SMILE procedure for myopic astigmatism (− 8.50 DS/− 1.50 DC × 175°) due to medical negligence. The extracted lenticule was subsequently re-implanted in situ. After 8 months, the left eye underwent FS-LASIK to correct hyperopia and astigmatism (+ 5.0 DS/− 0.75 DC × 100°). Two years after FS-LASIK, corneal tomography showed no ectasia and microscopy revealed transparent cornea. The left eye exhibited CDVA of 20/50 with refraction of − 0.75 DS/− 0.25 DC × 165°. SMILE lenticule in situ implantation offers a solution for corneal volume and thickness restoration. FS-LASIK provides feasible correction of refractive error following lenticule re-implantation. Future studies are needed for determining the effectiveness of the treatment.
- Open Access
- 31 May 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 131
Safety and satisfaction of myopic small-incision lenticule extraction combined with monovision
To investigate the safety and optical quality of small-incision lenticule extraction (SMILE) combined with monovision, and patient satisfaction with the procedure. The present study assessed a non-random case series involving 60 eyes of 30 patients (mean age 45.53 ± 3.20 years [range 41 to 52 years]) treated bilaterally using the VisuMax 500 system (Carl Zeiss Meditec, Jena, Germany) between January and July 2016. The target refraction was plano for the distance eye, and between − 0.5 and − 1.75 diopters (D) for the near eye. Visual acuity, refraction errors, ocular aberrations, and satisfaction questionnaire scores were calculated 1 year after surgery. All surgeries were uneventful, with a mean safety index of 1.03 and 1.04 in dominant and nondominant eyes, respectively. Binocular uncorrected distance visual acuity of all patients was ≥20/32, while binocular uncorrected near visual acuity was ≥20/40 1 year postoperatively. Higher-order aberration (0.45 ± 0.14, 0.51 ± 0.15 μm), spherical (0.18 ± 0.15, 0.21 ± 0.14 μm) and coma aberration (0.31 ± 0.16, 0.27 ± 0.17 μm) were identical between dominant and nondominant eyes after surgery. The overall satisfaction rate was 86.7% (26/30), with large contributions from age (OR = 1.76 95% CI: 1.03–2.53; P = 0.036). Binocular uncorrected distance visual acuity was related to preoperative spherical diopter (r = − 0.500; P = 0.005). Monovision appears to be a safe and effective option for myopia patients with presbyopia who are considering the SMILE procedure. Patients with younger age were more satisfied with the procedure.
- 31 May 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 131
Open AccessSafety and satisfaction of myopic small-incision lenticule extraction combined with monovision
To investigate the safety and optical quality of small-incision lenticule extraction (SMILE) combined with monovision, and patient satisfaction with the procedure. The present study assessed a non-random case series involving 60 eyes of 30 patients (mean age 45.53 ± 3.20 years [range 41 to 52 years]) treated bilaterally using the VisuMax 500 system (Carl Zeiss Meditec, Jena, Germany) between January and July 2016. The target refraction was plano for the distance eye, and between − 0.5 and − 1.75 diopters (D) for the near eye. Visual acuity, refraction errors, ocular aberrations, and satisfaction questionnaire scores were calculated 1 year after surgery. All surgeries were uneventful, with a mean safety index of 1.03 and 1.04 in dominant and nondominant eyes, respectively. Binocular uncorrected distance visual acuity of all patients was ≥20/32, while binocular uncorrected near visual acuity was ≥20/40 1 year postoperatively. Higher-order aberration (0.45 ± 0.14, 0.51 ± 0.15 μm), spherical (0.18 ± 0.15, 0.21 ± 0.14 μm) and coma aberration (0.31 ± 0.16, 0.27 ± 0.17 μm) were identical between dominant and nondominant eyes after surgery. The overall satisfaction rate was 86.7% (26/30), with large contributions from age (OR = 1.76 95% CI: 1.03–2.53; P = 0.036). Binocular uncorrected distance visual acuity was related to preoperative spherical diopter (r = − 0.500; P = 0.005). Monovision appears to be a safe and effective option for myopia patients with presbyopia who are considering the SMILE procedure. Patients with younger age were more satisfied with the procedure.