JHJiayang He

Jiayang He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiayang He has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Performance of Textile Mask Materials in Varied Humidity: Filtration Efficiency, Breathability, and Quality Factor

    by Joelle M. Segovia, Ching-Hsuan Huang, Maxwell Mamishev, Nanhsun Yuan, Jiayang He, Igor Novosselov

    During the COVID-19 pandemic, reusable masks became ubiquitous; these masks were made from various fabrics without guidance from the research community or regulating agencies. Though reusable masks reduce the waste stream associated with disposable masks and promote the use of masks by the population, their efficacy in preventing the transmission of infectious agents has not been evaluated sufficiently. Among the unknowns is the effect of relative humidity (RH) on fabrics’ filtration efficiency (FE) and breathability. This study evaluates the FE and breathability of several readily accessible mask materials in an aerosol chamber. Sodium chloride aerosols were used as the challenge aerosol with aerodynamic particle diameter in the 0.5 to 2.5 µm range. To mimic the variability in RH in the environment and the exhaled-breath condition, the chamber was operated at RH of 30% to 70%. The face velocity was varied between 0.05 m/s and 0.19 m/s to simulate different breathing rates. The FE and pressure drop were used to determine the quality factor of the materials. Among the tested materials, the 3M P100 filter has the highest pressure drop of 140 Pa; the N95 mask and the 3M P100 have almost 100% FE for all sizes of particles and tested face velocities; the surgical mask has nearly 90% FE for all the particles and the lowest pressure drop among the certified materials, which ranks it the second to the N95 mask in the quality factor. Other material performance data are presented as a function of relative humidity and aerosol size. The quality factor for each material was compared against reference filtration media and surgical masks. Multiple layers of selected materials are also tested. While the additional layers improve FE, the pressure drop increases linearly. Additionally, the certified materials performed approximately three times better than the highest performing non-certified material.


  • Open Access

    Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements

    by Ching-Hsuan Huang, Jiayang He, Elena Austin, Edmund Seto, Igor Novosselov

    Low-cost optical scattering particulate matter (PM) sensors report total or size-specific particle counts and mass concentrations. The PM concentration and size are estimated by the original equipment manufacturer (OEM) proprietary algorithms, which have inherent limitations since particle scattering depends on particles’ properties such as size, shape, and complex index of refraction (CRI) as well as environmental parameters such as temperature and relative humidity (RH). As low-cost PM sensors are not able to resolve individual particles, there is a need to characterize and calibrate sensors’ performance under a controlled environment. Here, we present improved calibration algorithms for Plantower PMS A003 sensor for mass indices and size-resolved number concentration. An aerosol chamber experimental protocol was used to evaluate sensor-to-sensor data reproducibility. The calibration was performed using four polydisperse test aerosols. The particle size distribution OEM calibration for PMS A003 sensor did not agree with the reference single particle sizer measurements. For the number concentration calibration, the linear model without adjusting for the aerosol properties and environmental conditions yields an absolute error (NMAE) of ~ 4.0% compared to the reference instrument. The calibration models adjusted for particle CRI and density account for non-linearity in the OEM’s mass concentrations estimates with NMAE within 5.0%. The calibration algorithms developed in this study can be used in indoor air quality monitoring, occupational/industrial exposure assessments, or near-source monitoring scenarios where field calibration might be challenging.


  • Open Access

    Methodology for Addressing Infectious Aerosol Persistence in Real-Time Using Sensor Network

    by Sepehr Makhsous, Joelle M. Segovia, Jiayang He, Daniel Chan, Larry Lee, Igor V. Novosselov, Alexander V. Mamishev

    Human exposure to infectious aerosols results in the transmission of diseases such as influenza, tuberculosis, and COVID-19. Most dental procedures generate a significant number of aerosolized particles, increasing transmission risk in dental settings. Since the generation of aerosols in dentistry is unavoidable, many clinics have started using intervention strategies such as area-filtration units and extraoral evacuation equipment, especially under the relatively recent constraints of the pandemic. However, the effectiveness of these devices in dental operatories has not been studied. Therefore, the ability of dental personnel to efficiently position and operate such instruments is also limited. To address these challenges, we utilized a real-time sensor network for assessment of aerosol dynamics during dental restoration and cleaning producers with and without intervention. The strategies tested during the procedures were (i) local area High-Efficiency Particle Air (HEPA) filters and (ii) Extra-Oral Suction Device (EOSD). The study was conducted at the University of Washington School of Dentistry using a network of 13 fixed sensors positioned within the operatory and one wearable sensor worn by the dental operator. The sensor network provides time and space-resolved particulate matter (PM) data. Three-dimensional (3D) visualization informed aerosol persistence in the operatory. It was found that area filters did not improve the overall aerosol concentration in dental offices in a significant way. A decrease in PM concentration by an average of 16% was observed when EOSD equipment was used during the procedures. The combination of real-time sensors and 3D visualization can provide dental personnel and facility managers with actionable feedback to effectively assess aerosol transmission in medical settings and develop evidence-based intervention strategies.


  • Open Access

    Solid-phase excitation-emission matrix spectroscopy for chemical analysis of combustion aerosols

    by Gaurav Mahamuni, Jiayang He, Jay Rutherford, Byron Ockerman, Arka Majumdar, Edmund Seto, Gregory Korshin, Igor Novosselov

    Exposure to ultrafine combustion aerosols such as particulate matter (PM) from residential woodburning, forest fires, cigarette smoke, and traffic emission have been linked to adverse health outcomes. Excitation-emission matrix (EEM) spectroscopy presents a sensitive and cost-effective alternative for analysis of PM organic fraction. However, as with other analytical chemistry methods, the miniaturization is hindered by a solvent extraction step and a need for benchtop instrumentation. We present a methodology for collecting and in-situ analysis of airborne nanoparticles that eliminates labor-intensive sample preparation and miniaturizes the detection platform. Nanoparticles are electrostatically collected onto a transparent substrate coated with solid-phase (SP) solvent—polydimethylsiloxane (PDMS). The PM organic fraction is extracted into PDMS and analyzedin-situ, thus avoiding liquid-phase extraction. In the SP-EEM analysis, we evaluated external and internal excitation schemes. Internal excitation shows the lowest scattering interference but leads to signal masking from PDMS fluorescence for λ<250nm. The external excitation EEM spectra are dependent on the excitation light incident angle; ranges of 30–40° and 55–65° show the best results. SP-EEM spectra of woodsmoke and cigarette smoke samples are in good agreement with the EEM spectra of liquid-phase extracts. The SP-EEM technique can be used to develop wearable sensors for exposure assessments and environmental monitoring.


  • Open Access

    Methodology for Addressing Infectious Aerosol Persistence in Real-Time Using Sensor Network

    by Sepehr Makhsous, Joelle M. Segovia, Jiayang He, Daniel Chan, Larry Lee, Igor V Novosselov, Alexander V Mamishev

    Human exposure to infectious aerosols results a transmission of diseases, such as influenza, tuberculosis, and COVID-19. Most dental procedures generate a significant number of aerosolized particles, increasing transmission risk in dental settings. Since the generation of aerosols in dentistry is unavoidable, many clinics started using intervention strategies such as area-filtration units and extraoral evacuation equipment, especially under the relatively recent constraints of the pandemics. However, the effectiveness of these devices in dental operatories has not been studied. Therefore, the dental personnel's ability to position and operate such instruments efficiently is also limited. To address these challenges, we utilized a real-time sensor network for assessment of aerosol dynamics during dental restoration and cleaning producers with and without intervention. The strategies tested during the procedures were (i) local area high-efficiency particle air (HEPA) filters and (ii) extra-oral suction device (EOSD). The study was conducted at the University of Washington School of Dentistry using a network of thirteen fixed sensors positioned within the operatory and one wearable sensor worn by the dental operator. The sensor network provides time and space-resolved particulate matter (PM) data. Three-dimensional (3D) visualization informs aerosol persistence in the operatory. It was found that area filters did not improve the overall aerosol concentration in dental offices significantly. An average of 16% decrease in PM concentration was observed when EOSD equipment was used during the procedures. The combination of real-time sensors and 3D visualization can provide dental personnel and facility mangers with actionable feedback to effectively assess aerosol transmission in medical settings and develop evidence-based intervention strategies.


  • Open Access

    Miniaturizing wet scrubbers for aerosolized droplet capture

    by Ulri N. Lee, Tammi L. van Neel, Fang Yun Lim, Jian Wei Khor, Jiayang He, Ravi S. Vaddi, Angelo Q.W. Ong, Anthony Tang, Jean Berthier, John S. Meschke, et al.

    Aerosols dispersed and transmitted through the air (e.g., particulate matter pollution, bioaerosols) are ubiquitous and one of the leading causes of adverse health effects and disease transmission. A variety of sampling methods (e.g., filters, cyclones, impactors) have been developed to assess personal exposures. However, a gap still remains in the accessibility and ease-of-use of these technologies for people without experience or training in collecting airborne samples. Additionally, wet scrubbers (large non-portable industrial systems) utilize liquid sprays to remove aerosols from the air; the goal is to “scrub” (i.e., clean) the exhaust of industrial smokestacks, not collect the aerosols for analysis. Inspired by wet scrubbers, we developed a device fundamentally different from existing portable air samplers by using aerosolized microdroplets to capture aerosols in personal spaces (e.g., homes, offices, schools). Our aerosol-sampling device is the size of a small teapot, can be operated without specialized training, and features a winding flow path in a supersaturated relative humidity environment enabling droplet growth. The integrated open mesofluidic channels shuttle coalesced droplets to a collection chamber for subsequent sample analysis. Here, we present the experimental demonstration of aerosol capture into water droplets. Iterative study optimized the non-linear flow manipulating baffles and enabled an 83% retention of the aerosolized microdroplets in the confined volume of our device. As a proof-of-concept for aerosol capture into a liquid medium, 0.5-3 µm model particles were used to evaluate aerosol capture efficiency. Finally, we demonstrate the device can capture and keep a bioaerosol (bacteriophage MS2) viable for downstream analysis.

  • Open Access

    Solid Phase Excitation-Emission Matrix Spectroscopy for In-Situ Chemical Analysis of Combustion Aerosols

    by Gaurav Mahamuni, Jiayang He, Jay Rutherford, Byron Ockerman, Edmund Seto, Gregory V. Korshin, Igor V. Novosselov

    Exposure to combustion generated aerosols such as PM from residential woodburning, forest fires, cigarette smoke, and traffic emission have been linked to adverse health outcomes. It is important to assess the chemical composition of PM to examine personal exposure. Excitation-emission matrix (EEM) spectroscopy has been shown as a sensitive and cost-effective technique for evaluation of combustion PM composition and as a source apportionment tool. However, EEM measurements are hindered by a solvent extraction step and a need for benchtop instrumentation. Here, we present a methodology that eliminates this labor-intensive sample preparation and allows to automate and miniaturize the detection platform. A miniature electrostatic collector deposits PM sample onto transparent polydimethylsiloxane (PDMS) coated substrate, where PAH components are extracted into solid-phase (SP) solvent and analyzed using EEM spectroscopy in-situ. We evaluated external and internal excitation schemes to optimized signal to noise ratio. Analysis of woodsmoke and cigarette smoke samples showed good agreement with liquid extraction EEM spectra. Internal excitation is hindered by fluorescent interference from PDMS at λ<250nm. The external excitation EEM spectra are dependent on the incident angle; ranges of 30-40⁰ and 55-65⁰ showed the best results. The proposed SP-EEM technique can be used for development of miniaturized sensors for chemical analysis of combustion generated PM.

  • Open Access

    Evaluation of micro-well collector for capture and analysis of aerosolized Bacillus subtilis spores

    by Jiayang He, Nicola K Beck, Alexandra L Kossik, Jiawei Zhang, Edmund Seto, John Scott Meschke, Igor Novosselov

    Bioaerosol sampling and identification are vital for the assessment and control of airborne pathogens, allergens, and toxins. In-situ analysis of chemical and biological particulate matter can significantly reduce the costs associated with sample preservation, transport, and analysis. The analysis of conventional filters is challenging, due to dilute samples in large collection regions. A low-cost cartridge for collection and analysis of aerosols is developed for use in epidemiological studies and personal exposure assessments. The cartridge collects aerosol samples in a micro-well which reduces particles losses due to the bounce and does not require any coating. The confined particle collection area (dwell~1.4 mm) allows reducing the elution volume for subsequent analysis. The performance of the cartridge is validated in laboratory studies using aerosolized bacterial spores (Bacillus subtilis). Colony forming unit analysis is used for bacterial spore enumeration. Cartridge collection efficiency is evaluated by comparison with the reference filters and found to be consistent with tested flow rates. Sample recovery for the pipette elution is ~80%. Due to the high density of the collected sample, the cartridge is compatible with in-situ spectroscopic analysis and sample elution into the 10–20 μl liquid volume providing a significant increase in sample concentration for subsequent analysis.