Yu He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yu He has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Xi Zhou
Department of Orthopedics, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
3 shared publications Dongsheng Zhou
Department of Orthopaedics, Shandong Provincial Hospital Affiliated to Shandong University, Ji'nan, Shandong, China
2 shared publicationsWenhao Song
Department of Orthopaedics, Shandong Provincial Hospital Affiliated to Shandong University, Ji'nan, Shandong, China
2 shared publicationsAnna Mou
Department of Radiology, Sichuan Academy of Medical Sciences, Sichuan Provincial People's Hospital, Chengdu, Sichuan Province, China
1 shared publicationBin Yan
Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Tradit Chinese Med, Beijing, Peoples R China
1 shared publicationDi Wu
Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Orthoped Surg, 1 Shuaifuyuan Rd, Beijing 100730, Peoples R China
1 shared publication
Latest Publications
- Open Access
- 1 February 2021
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 9 (4) , 318
A novel prophylactic Chinese parachute ankle brace
Background: The objective is to compare the effects of a self-designed and self-manufactured novel prophylactic ankle brace [Chinese parachute ankle brace (CPAB)] and two ordinary ankle braces on the ankle joint during a half-squat parachute landing (HSPL) via biomechanical assessment. Methods: Twenty elite paratroopers were in four different conditions: no brace, elastic brace, semi-rigid brace, and CPAB. Each participant was instructed to jump off a platform with three different heights, 40, 80, and 120 cm, and land on the force plate in a half-squat posture. The vertical ground reaction forces (vGRFs), joint angles, moments, powers, and works were calculated. After the experiment, every participant completed the questionnaires designed for this study. Results: Increasing the dropping height increased all of the parameters significantly (PConclusions: The CPAB was more effective at restricting ankle joint motion on the coronal and sagittal planes than the other two prophylactic ankle braces. Therefore, the CPAB had the advantages of a novel appearance, high efficiency, and superior comfort, providing a reliable choice for parachute jumping and training in China.
- 1 February 2021
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 9 (4) , 318
Open AccessA novel prophylactic Chinese parachute ankle brace
Background: The objective is to compare the effects of a self-designed and self-manufactured novel prophylactic ankle brace [Chinese parachute ankle brace (CPAB)] and two ordinary ankle braces on the ankle joint during a half-squat parachute landing (HSPL) via biomechanical assessment. Methods: Twenty elite paratroopers were in four different conditions: no brace, elastic brace, semi-rigid brace, and CPAB. Each participant was instructed to jump off a platform with three different heights, 40, 80, and 120 cm, and land on the force plate in a half-squat posture. The vertical ground reaction forces (vGRFs), joint angles, moments, powers, and works were calculated. After the experiment, every participant completed the questionnaires designed for this study. Results: Increasing the dropping height increased all of the parameters significantly (PConclusions: The CPAB was more effective at restricting ankle joint motion on the coronal and sagittal planes than the other two prophylactic ankle braces. Therefore, the CPAB had the advantages of a novel appearance, high efficiency, and superior comfort, providing a reliable choice for parachute jumping and training in China.
- Open Access
- 26 August 2020
- Published by Wiley in Journal of Oncology
- Vol. 2020, 1-14
Clinicopathological and Prognostic Value of Gastric Carcinoma Highly Expressed Transcript 1 in Cancer: A Meta-Analysis
Background. Long noncoding RNA gastric cancer highly expressed transcript 1 (lncRNA GHET1) is often reported to be abnormally expressed in multiple cancers, but the situation is different in different cancers. Therefore, a meta-analysis is necessary to clarify the value of lncRNA GHET1 as a prognostic indicator in cancer. Methods. Relevant research studies on lncRNA GHET1 and cancer were retrieved from three electronic literature databases of Web of Science, PubMed, and OVID. Meanwhile, hazard ratios (HRs) and 95% confidence intervals (CIs) were calculated to explore the relationship between lncRNA GHET1 expression and survival of cancer patients. The odds ratios (ORs) and 95% CIs were calculated to assess the association of lncRNA GHET1 expression with pathological parameters of cancer patients. Results. The meta-analysis included a total of 11 studies involving 714 cancer patients. The pooled HR suggests that high lncRNA GHET1 expression is associated with poor overall survival. In addition, high expression of lncRNA GHET1 was found to be associated with larger tumor size, poor histological grade, high tumor stage, lymph node metastasis, and distant metastasis. Conclusions. High lncRNA GHET1 expression can predict poor survival and pathological parameters. And lncRNA GHET1 could serve as a new indicator in multiple cancers.
- 26 August 2020
- Published by Wiley in Journal of Oncology
- Vol. 2020, 1-14
Open AccessClinicopathological and Prognostic Value of Gastric Carcinoma Highly Expressed Transcript 1 in Cancer: A Meta-Analysis
Background. Long noncoding RNA gastric cancer highly expressed transcript 1 (lncRNA GHET1) is often reported to be abnormally expressed in multiple cancers, but the situation is different in different cancers. Therefore, a meta-analysis is necessary to clarify the value of lncRNA GHET1 as a prognostic indicator in cancer. Methods. Relevant research studies on lncRNA GHET1 and cancer were retrieved from three electronic literature databases of Web of Science, PubMed, and OVID. Meanwhile, hazard ratios (HRs) and 95% confidence intervals (CIs) were calculated to explore the relationship between lncRNA GHET1 expression and survival of cancer patients. The odds ratios (ORs) and 95% CIs were calculated to assess the association of lncRNA GHET1 expression with pathological parameters of cancer patients. Results. The meta-analysis included a total of 11 studies involving 714 cancer patients. The pooled HR suggests that high lncRNA GHET1 expression is associated with poor overall survival. In addition, high expression of lncRNA GHET1 was found to be associated with larger tumor size, poor histological grade, high tumor stage, lymph node metastasis, and distant metastasis. Conclusions. High lncRNA GHET1 expression can predict poor survival and pathological parameters. And lncRNA GHET1 could serve as a new indicator in multiple cancers.
- Open Access
- 29 May 2018
- Published by Springer Nature in BMC Surgery
- Vol. 18 (1) , 1-11
Clinical significance of three-dimensional skeleton-arterial model in the management of delayed reconstruction of acetabular fractures
Delayed reconstruction of acetabular fractures remains a challenging task for orthopedists because of malunion, fracture line absorption, and scar formation. Accurate osteotomy, interfragmentary release, and proper adaptation of plates are keys to successful surgery. Prevention of superior gluteal artery (SGA) injury induced by cleaning of the osteotylus and reduction of the sciatic notch is also important. Therefore, sufficient preoperative planning is essential. However, traditional planning methods do not readily provide direct visual and tactile feedback to surgeons. Rapid prototyping (RP) models have provided new opportunities in the preoperative planning of delayed reconstruction of acetabular fractures. We hypothesized that a three-dimensional (3D) skeleton-arterial model would improve both preoperative planning in the management of fractures and arteries and intraoperative assistance during delayed reconstruction of complex acetabular fractures. Eight patients were enrolled in this study. Data on the skeleton and arteries were obtained from computed tomography and angiography scans and used to produce RP models. Preoperative surgical planning and intraoperative assistance were performed using these models as references. All 3D skeleton-arterial models were extremely accurate. Reduction and fixation were performed programmatically and smoothly, and management of the SGA was reliably executed according to a thorough preoperative plan. The mean surgical time and intraoperative blood loss were 224.4 min and 1250 ml, respectively. Among the eight patients, four underwent anatomic reduction and five had excellent functional outcomes at the final follow-up. No significant complications occurred. This 3D skeleton-arterial model is helpful for orthopedists in preoperative planning and intraoperative assistance.
- 29 May 2018
- Published by Springer Nature in BMC Surgery
- Vol. 18 (1) , 1-11
Open AccessClinical significance of three-dimensional skeleton-arterial model in the management of delayed reconstruction of acetabular fractures
Delayed reconstruction of acetabular fractures remains a challenging task for orthopedists because of malunion, fracture line absorption, and scar formation. Accurate osteotomy, interfragmentary release, and proper adaptation of plates are keys to successful surgery. Prevention of superior gluteal artery (SGA) injury induced by cleaning of the osteotylus and reduction of the sciatic notch is also important. Therefore, sufficient preoperative planning is essential. However, traditional planning methods do not readily provide direct visual and tactile feedback to surgeons. Rapid prototyping (RP) models have provided new opportunities in the preoperative planning of delayed reconstruction of acetabular fractures. We hypothesized that a three-dimensional (3D) skeleton-arterial model would improve both preoperative planning in the management of fractures and arteries and intraoperative assistance during delayed reconstruction of complex acetabular fractures. Eight patients were enrolled in this study. Data on the skeleton and arteries were obtained from computed tomography and angiography scans and used to produce RP models. Preoperative surgical planning and intraoperative assistance were performed using these models as references. All 3D skeleton-arterial models were extremely accurate. Reduction and fixation were performed programmatically and smoothly, and management of the SGA was reliably executed according to a thorough preoperative plan. The mean surgical time and intraoperative blood loss were 224.4 min and 1250 ml, respectively. Among the eight patients, four underwent anatomic reduction and five had excellent functional outcomes at the final follow-up. No significant complications occurred. This 3D skeleton-arterial model is helpful for orthopedists in preoperative planning and intraoperative assistance.
- Open Access
- 1 April 2018
- Published by Wolters Kluwer Health in Medicine
- Vol. 97 (14) , e0338
Nurses’ objective knowledge regarding venous thromboembolism prophylaxis
Venous thromboembolism (VTE) is a common vascular disorder with high mortality and morbidity. Clinical nurses are a pivotal group that can serve as first-line health care providers. Lack of knowledge about VTE is an important barrier to effective nursing performance. This study aimed to determine nurses’ knowledge of VTE prophylaxis through a nationwide survey across China, to understand gaps between current knowledge, and guidelines, and to help improve clinical nursing. The survey included 5 topics with 68 items on VTE, including basic knowledge, risk assessment, basic prophylaxis, physical prophylaxis, and pharmacological prophylaxis. The survey was distributed to 106 AAA-grade hospitals throughout China; 5218 valid questionnaires were submitted for analysis. There were 5097 women and 121 men respondents, with average age 30.29 ± 8.60 years. The average rate of correct responses regarding VTE knowledge was 59.90 ± 15.63%; 77.81% of subjects answered more than half of the survey items correctly. Better knowledge about thromboprophylaxis was observed among nurses who were more highly educated, more experienced, had received continuing education, intensive care unit (ICU), and lead nurses. Correct response rates were 68.39 ± 17.03%, 60.35 ± 21.01%, 75.51 ± 22.85%, 41.72 ± 17.47%, and 46.01 ± 21.22% for basic knowledge, risk assessment, basic prophylaxis, physical prophylaxis, and pharmacological prophylaxis, respectively. Respondents showed satisfactory results regarding basic prophylaxis, basic knowledge, and risk assessment for VTE; respondents had poorer knowledge regarding physical and pharmacological prophylaxis. Better mastery of knowledge about thromboprophylaxis was observed among nurses who were more highly educated, more experienced, had received continuous education, ICU, and lead nurses. This study suggested that nurse trainers should develop comprehensive educational programs that focus on low correct rate aspects. Higher-level continuous education could improve nurses’ knowledge of thromboprophylaxis.
- 1 April 2018
- Published by Wolters Kluwer Health in Medicine
- Vol. 97 (14) , e0338
Open AccessNurses’ objective knowledge regarding venous thromboembolism prophylaxis
Venous thromboembolism (VTE) is a common vascular disorder with high mortality and morbidity. Clinical nurses are a pivotal group that can serve as first-line health care providers. Lack of knowledge about VTE is an important barrier to effective nursing performance. This study aimed to determine nurses’ knowledge of VTE prophylaxis through a nationwide survey across China, to understand gaps between current knowledge, and guidelines, and to help improve clinical nursing. The survey included 5 topics with 68 items on VTE, including basic knowledge, risk assessment, basic prophylaxis, physical prophylaxis, and pharmacological prophylaxis. The survey was distributed to 106 AAA-grade hospitals throughout China; 5218 valid questionnaires were submitted for analysis. There were 5097 women and 121 men respondents, with average age 30.29 ± 8.60 years. The average rate of correct responses regarding VTE knowledge was 59.90 ± 15.63%; 77.81% of subjects answered more than half of the survey items correctly. Better knowledge about thromboprophylaxis was observed among nurses who were more highly educated, more experienced, had received continuing education, intensive care unit (ICU), and lead nurses. Correct response rates were 68.39 ± 17.03%, 60.35 ± 21.01%, 75.51 ± 22.85%, 41.72 ± 17.47%, and 46.01 ± 21.22% for basic knowledge, risk assessment, basic prophylaxis, physical prophylaxis, and pharmacological prophylaxis, respectively. Respondents showed satisfactory results regarding basic prophylaxis, basic knowledge, and risk assessment for VTE; respondents had poorer knowledge regarding physical and pharmacological prophylaxis. Better mastery of knowledge about thromboprophylaxis was observed among nurses who were more highly educated, more experienced, had received continuous education, ICU, and lead nurses. This study suggested that nurse trainers should develop comprehensive educational programs that focus on low correct rate aspects. Higher-level continuous education could improve nurses’ knowledge of thromboprophylaxis.
- Open Access
- 17 January 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (1) , e0191328
Three-dimensional printing model improves morphological understanding in acetabular fracture learning: A multicenter, randomized, controlled study
Conventional education results in unsatisfactory morphological understanding of acetabular fractures due to lack of three-dimensional (3D) details and tactile feedback of real fractures. Virtual reality (VR) and 3D printing (3DP) techniques are widely applied in teaching. The purpose of this study was to identify the effect of physical model (PM), VR and 3DP models in education of morphological understanding of acetabular fractures. 141 students were invited to participate in this study. Participants were equally and randomly assigned to the PM, VR and 3DP learning groups. Three-level objective tests were conducted to evaluate learning, including identifying anatomical landmarks, describing fracture lines, identifying classification, and inferring fracture mechanism. Four subjective questions were asked to evaluate the usability and value of instructional materials. Generally, the 3DP group showed a clear advantage over the PM and VR groups in objective tests, while there was no significant difference between the PM and VR groups. 3DP was considered to be the most valuable learning tool for understanding acetabular fractures. The findings demonstrate that 3DP modelling of real fractures is an effective learning instrument that can be used to understand the morphology of acetabular fractures and promote subjective interest.
- 17 January 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (1) , e0191328
Open AccessThree-dimensional printing model improves morphological understanding in acetabular fracture learning: A multicenter, randomized, controlled study
Conventional education results in unsatisfactory morphological understanding of acetabular fractures due to lack of three-dimensional (3D) details and tactile feedback of real fractures. Virtual reality (VR) and 3D printing (3DP) techniques are widely applied in teaching. The purpose of this study was to identify the effect of physical model (PM), VR and 3DP models in education of morphological understanding of acetabular fractures. 141 students were invited to participate in this study. Participants were equally and randomly assigned to the PM, VR and 3DP learning groups. Three-level objective tests were conducted to evaluate learning, including identifying anatomical landmarks, describing fracture lines, identifying classification, and inferring fracture mechanism. Four subjective questions were asked to evaluate the usability and value of instructional materials. Generally, the 3DP group showed a clear advantage over the PM and VR groups in objective tests, while there was no significant difference between the PM and VR groups. 3DP was considered to be the most valuable learning tool for understanding acetabular fractures. The findings demonstrate that 3DP modelling of real fractures is an effective learning instrument that can be used to understand the morphology of acetabular fractures and promote subjective interest.
- Open Access
- 7 March 2017
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 12 (1) , 38
Biomechanical characteristics of fixation methods for floating pubic symphysis
Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The goal of this study was to compare the biomechanical characteristics of six methods by finite element analysis. A three-dimensional finite element model of FPS was simulated. Six methods were used in the FPS model, including external fixation (Ext), subcutaneous rod fixation (Sub-rod), subcutaneous plate fixation (Sub-plate), superior pectineal plate fixation (Int-sup), infrapectineal plate fixation (Int-ifa), and cannulated screw fixation (Int-scr). Compressive and rotational loads were then applied in all models. Biomechanical characteristics that were recorded and analyzed included construct stiffness, micromotion of the fracture gaps, von Mises stress, and stress distribution. The construct stiffness of the anterior pelvic ring was decreased dramatically when FPS occurred. Compressive stiffness was restored by the three internal fixation and Sub-rod methods. Unfortunately, rotational stiffness was not restored satisfactorily by the six methods. For micromotion of the fracture gaps, the displacement was reduced significantly by the Int-sup and Int-ifa methods under compression. The internal fixation methods and Sub-plate method performed well under rotation. The maximum von Mises stress of the implants was not large. For the plate-screw system, the maximum von Mises stress occurred over the region of the fracture and plate-screw joints. The maximum von Mises stress appeared on the rod-screw and screw-bone interfaces for the rod-screw system. The present study showed the biomechanical advantages of internal fixation methods for FPS from a finite element view. Superior stabilization of the anterior pelvic ring and fracture gaps was obtained by internal fixation. Subcutaneous fixation had satisfactory outcomes as well. Sub-rod fixation offered good anti-compression, while the Sub-plate fixation provided favorable anti-rotational capacity.
- 7 March 2017
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 12 (1) , 38
Open AccessBiomechanical characteristics of fixation methods for floating pubic symphysis
Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The goal of this study was to compare the biomechanical characteristics of six methods by finite element analysis. A three-dimensional finite element model of FPS was simulated. Six methods were used in the FPS model, including external fixation (Ext), subcutaneous rod fixation (Sub-rod), subcutaneous plate fixation (Sub-plate), superior pectineal plate fixation (Int-sup), infrapectineal plate fixation (Int-ifa), and cannulated screw fixation (Int-scr). Compressive and rotational loads were then applied in all models. Biomechanical characteristics that were recorded and analyzed included construct stiffness, micromotion of the fracture gaps, von Mises stress, and stress distribution. The construct stiffness of the anterior pelvic ring was decreased dramatically when FPS occurred. Compressive stiffness was restored by the three internal fixation and Sub-rod methods. Unfortunately, rotational stiffness was not restored satisfactorily by the six methods. For micromotion of the fracture gaps, the displacement was reduced significantly by the Int-sup and Int-ifa methods under compression. The internal fixation methods and Sub-plate method performed well under rotation. The maximum von Mises stress of the implants was not large. For the plate-screw system, the maximum von Mises stress occurred over the region of the fracture and plate-screw joints. The maximum von Mises stress appeared on the rod-screw and screw-bone interfaces for the rod-screw system. The present study showed the biomechanical advantages of internal fixation methods for FPS from a finite element view. Superior stabilization of the anterior pelvic ring and fracture gaps was obtained by internal fixation. Subcutaneous fixation had satisfactory outcomes as well. Sub-rod fixation offered good anti-compression, while the Sub-plate fixation provided favorable anti-rotational capacity.
- Open Access
- 1 December 2015
- Published by Wolters Kluwer Health in Medicine
- Vol. 94 (49) , e2207
Comparison of Biomechanical Characteristics and Pelvic Ring Stability Using Different Fixation Methods to Treat Pubic Symphysis Diastasis
The intention of this study was to compare the biomechanical characteristics using 5 internal fixation methods used clinically to stabilize a pubic symphysis diastasis (PSD, Tile type B1). A 3-dimensional finite element model of PSD was simulated using 5 implants, including single superior plate (Single-Plate), superior and anterior plate (Dual-Plate), single cannulated screw (Single-Screw), crossed dual cannulated screws (Cross-Screw), and parallel dual cannulated screws (Para-Screw). Three loads were distributed in all models, including dual-leg standing, single-leg stance, and rotation. To evaluate the biomechanical properties, the construct stiffness, the stress distribution, and the von Misses stress were recorded and analyzed. To evaluate pelvic ring stability, the micromotion of the pubic symphysis and iliosacral joint was analyzed. Disruption of pubic symphysis dramatically decreased the pelvic ring stability. Cross-screw and Para-Screw showed higher stiffness than other methods. All implants endured the maximum von Misses stress under single-leg stance. For Plate-Screw system, the maximum stress occurred at a place where it strides over pubic symphysis and adjacent Plate-Screw interface. The single implant and Para-Screw had a tendency to fail. Para-Screw showed the best fixation effect under dual-leg conditions. Cross-screw showed superior antishearing force capacity under single-leg stance. Dual-Plate provided maximum antihorizontal rotation. Para-Screw provided the maximum stabilization for the posterior pelvic ring. This study showed the biomechanical advantages of dual-implant for PSD only from the finite element view. The Para-Screw provided high construct stiffness under 3 load conditions. The single implant and Para-Screw had a tendency to fail. The better anterior and posterior pelvic stabilization were obtained by the dual-implant fixation than other methods. Therefore, the Cross-Screw and Dual-Plate fixation methods should be preferred in the treatment of pubic symphysis from the finite element view.
- 1 December 2015
- Published by Wolters Kluwer Health in Medicine
- Vol. 94 (49) , e2207
Open AccessComparison of Biomechanical Characteristics and Pelvic Ring Stability Using Different Fixation Methods to Treat Pubic Symphysis Diastasis
The intention of this study was to compare the biomechanical characteristics using 5 internal fixation methods used clinically to stabilize a pubic symphysis diastasis (PSD, Tile type B1). A 3-dimensional finite element model of PSD was simulated using 5 implants, including single superior plate (Single-Plate), superior and anterior plate (Dual-Plate), single cannulated screw (Single-Screw), crossed dual cannulated screws (Cross-Screw), and parallel dual cannulated screws (Para-Screw). Three loads were distributed in all models, including dual-leg standing, single-leg stance, and rotation. To evaluate the biomechanical properties, the construct stiffness, the stress distribution, and the von Misses stress were recorded and analyzed. To evaluate pelvic ring stability, the micromotion of the pubic symphysis and iliosacral joint was analyzed. Disruption of pubic symphysis dramatically decreased the pelvic ring stability. Cross-screw and Para-Screw showed higher stiffness than other methods. All implants endured the maximum von Misses stress under single-leg stance. For Plate-Screw system, the maximum stress occurred at a place where it strides over pubic symphysis and adjacent Plate-Screw interface. The single implant and Para-Screw had a tendency to fail. Para-Screw showed the best fixation effect under dual-leg conditions. Cross-screw showed superior antishearing force capacity under single-leg stance. Dual-Plate provided maximum antihorizontal rotation. Para-Screw provided the maximum stabilization for the posterior pelvic ring. This study showed the biomechanical advantages of dual-implant for PSD only from the finite element view. The Para-Screw provided high construct stiffness under 3 load conditions. The single implant and Para-Screw had a tendency to fail. The better anterior and posterior pelvic stabilization were obtained by the dual-implant fixation than other methods. Therefore, the Cross-Screw and Dual-Plate fixation methods should be preferred in the treatment of pubic symphysis from the finite element view.