Zhuohua Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhuohua Lin has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Atsuo Takanishi
Waseda University
1 shared publication - Atsushi Kato
Division of Allergy and Immunology, Department of Medicine Northwestern University Feinberg School of Medicine Chicago Illinois USA
1 shared publication - Bo Zhang
Future Robotics Organization, Waseda University, Tokyo, Japan
1 shared publication - Chunbao Wang
Shenzhen Institute of Geriatrics, Shenzhen, China
1 shared publication - Hiroyuki Ishii
Waseda University
1 shared publication - Jianjun Long
Department of Rehabilitation, Shenzhen Second People’s Hospital, Shenzhen, China
1 shared publication
Latest Publications
- Open Access
- 15 March 2018
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2018, 1-12
Development of a New Robotic Ankle Rehabilitation Platform for Hemiplegic Patients after Stroke
A large amount of hemiplegic survivors are suffering from motor impairment. Ankle rehabilitation exercises act an important role in recovering patients’ walking ability after stroke. Currently, patients mainly perform ankle exercise to reobtain range of motion (ROM) and strength of the ankle joint under a therapist’s assistance by manual operation. However, therapists suffer from high work intensity, and most of the existed rehabilitation devices focus on ankle functional training and ignore the importance of neurological rehabilitation in the early hemiplegic stage. In this paper, a new robotic ankle rehabilitation platform (RARP) is proposed to assist patients in executing ankle exercise. The robotic platform consists of two three-DOF symmetric layer-stacking mechanisms, which can execute ankle internal/external rotation, dorsiflexion/plantarflexion, and inversion/eversion exercise while the rotation center of the distal zone of the robotic platform always coincides with patients’ ankle pivot center. Three exercise modes including constant-speed exercise, constant torque-impedance exercise, and awareness exercise are developed to execute ankle training corresponding to different rehabilitation stages. Experiments corresponding to these three ankle exercise modes are performed, the result demonstrated that the RARP is capable of executing ankle rehabilitation, and the novel awareness exercise mode motivates patients to proactively participate in ankle training.
- 15 March 2018
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2018, 1-12
Open AccessDevelopment of a New Robotic Ankle Rehabilitation Platform for Hemiplegic Patients after Stroke
A large amount of hemiplegic survivors are suffering from motor impairment. Ankle rehabilitation exercises act an important role in recovering patients’ walking ability after stroke. Currently, patients mainly perform ankle exercise to reobtain range of motion (ROM) and strength of the ankle joint under a therapist’s assistance by manual operation. However, therapists suffer from high work intensity, and most of the existed rehabilitation devices focus on ankle functional training and ignore the importance of neurological rehabilitation in the early hemiplegic stage. In this paper, a new robotic ankle rehabilitation platform (RARP) is proposed to assist patients in executing ankle exercise. The robotic platform consists of two three-DOF symmetric layer-stacking mechanisms, which can execute ankle internal/external rotation, dorsiflexion/plantarflexion, and inversion/eversion exercise while the rotation center of the distal zone of the robotic platform always coincides with patients’ ankle pivot center. Three exercise modes including constant-speed exercise, constant torque-impedance exercise, and awareness exercise are developed to execute ankle training corresponding to different rehabilitation stages. Experiments corresponding to these three ankle exercise modes are performed, the result demonstrated that the RARP is capable of executing ankle rehabilitation, and the novel awareness exercise mode motivates patients to proactively participate in ankle training.
- 1 August 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21527431,p. 957-962
Design of a wireless miniature low cost EMG sensor using gold plated dry electrodes for biomechanics research
EMG sensors for biomechanics research and portable applications need to be small, wireless and power efficient. This imposes several constraints on the design methodology of such sensors. There are many commercially available devices which are expensive and have proprietary communication protocols. It is difficult to synchronize them with other devices. Furthermore, using gel-based electrodes for signal acquisition increases setup time and running costs. Hence we present the design of a miniaturized, wireless, low-cost and non-invasive dry-electrode EMG sensor that was prototyped in our lab and dubbed the `WB-EMG' Sensor. We demonstrate its working being fitted with a gold plated copper core electrode. By mounting the sensor on the extensor carpiulnaris and recording data during some simple exercises, we were able to show that its envelope in the frequency domain was similar to the expected EMG Pattern.
- 1 August 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21527431,p. 957-962
Design of a wireless miniature low cost EMG sensor using gold plated dry electrodes for biomechanics research
EMG sensors for biomechanics research and portable applications need to be small, wireless and power efficient. This imposes several constraints on the design methodology of such sensors. There are many commercially available devices which are expensive and have proprietary communication protocols. It is difficult to synchronize them with other devices. Furthermore, using gel-based electrodes for signal acquisition increases setup time and running costs. Hence we present the design of a miniaturized, wireless, low-cost and non-invasive dry-electrode EMG sensor that was prototyped in our lab and dubbed the `WB-EMG' Sensor. We demonstrate its working being fitted with a gold plated copper core electrode. By mounting the sensor on the extensor carpiulnaris and recording data during some simple exercises, we were able to show that its envelope in the frequency domain was similar to the expected EMG Pattern.
- 1 April 1994
- Published by JSTOR
- Vol. 38 (2) , 251-5
Direct Correlation between the Titer of Infectious Bursal Disease Virus VP2-Specific Antibody and Protection
The titer of antibody specific to infectious bursal disease virus (IBDV) was measured by a new method and correlated with protection. Challenge was carried out in chickens with various antibody titers, which were measured using a latex agglutination-inhibition (LI) test, a rapid and easy technique for measuring IBDV VP2-specific antibody. When actively immunized chickens had LI titers of 1:2 or more, almost all were protected from subsequent challenge with highly virulent IBDV. In contrast, even when chickens passively immunized with maternally derived antibody had LI titers of 1:4, half were susceptible to the same challenge.
- 1 April 1994
- Published by JSTOR
- Vol. 38 (2) , 251-5
Direct Correlation between the Titer of Infectious Bursal Disease Virus VP2-Specific Antibody and Protection
The titer of antibody specific to infectious bursal disease virus (IBDV) was measured by a new method and correlated with protection. Challenge was carried out in chickens with various antibody titers, which were measured using a latex agglutination-inhibition (LI) test, a rapid and easy technique for measuring IBDV VP2-specific antibody. When actively immunized chickens had LI titers of 1:2 or more, almost all were protected from subsequent challenge with highly virulent IBDV. In contrast, even when chickens passively immunized with maternally derived antibody had LI titers of 1:4, half were susceptible to the same challenge.