Bo Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Bo Zhang has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Chaoyang Shi
School of Mechanical Engineering Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education Tianjin University Tianjin China
8 shared publications - Aofei Tian
Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, China
3 shared publications - Chengzhi Hu
Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems, Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, China
3 shared publications - Dezhi Song
Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, China
3 shared publications - Yupeng Hao
Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, China
3 shared publications - Zhengbao Yang
Hong Kong University of Science and Technology
3 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Systems, Man, and Cybernetics: Systems
- Vol. 56 (11) , 6804-6817
Learning an Intention Projection Operator for Axis-Wise Human Control in Remote Piloted Aircraft Systems
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Systems, Man, and Cybernetics: Systems
- Vol. 56 (11) , 6804-6817
Open AccessLearning an Intention Projection Operator for Axis-Wise Human Control in Remote Piloted Aircraft Systems
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Development of a Novel 2-DoF Wearable Ankle Angle Sensor With an Adjustable Rotation Center
This paper presents a novel fiber Bragg grating (FBG)-based sensor for precise 2-degree-of-freedom (DoF) ankle angle monitoring. The proposed sensor primarily comprises two symmetric torsion springs, a planar spring, and three FBG-embedded optical fibers. Symmetric torsion springs are employed to measure plantarflexion/dorsiflexion (PF/DF) rotation, while a planar spring targets inversion/eversion (INV/EVE) motion, effectively minimizing cross-axis interference due to their distinct stiffness characteristics. Crucially, the sensor's high in-plane compliance accommodates the physiological shift of the ankle’s rotation center, enabling enhanced wearing comfort. Moreover, a symmetric differential fiber configuration compensates for rotation-axis variations and ensures high measurement accuracy. Structural optimization was conducted to maximize sensitivity and minimize crosstalk. Experimental results demonstrate high sensitivities of 37.09 pm/° (PF/DF) and 224.70 pm/° (INV/EVE) over ±55° and ±23°, respectively. The structural decoupling is validated by a low maximum crosstalk of 3.56%. Furthermore, the sensor maintains accuracy against rotation center offsets, with sensitivity deviations kept below 2.8% under a 2-mm misalignment. Dynamic tests at 50°/s and 300°/s yielded maximum root-mean-square errors (RMSEs) of 2.47° and 1.27° for PF/DF and INV/EVE, respectively. Finally, on-body validation, including seated range-of-motion tests, squat-to-stand exercises, and level walking, confirmed the sensor's ability to capture high-fidelity kinematic profiles for rehabilitation applications.
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Development of a Novel 2-DoF Wearable Ankle Angle Sensor With an Adjustable Rotation Center
This paper presents a novel fiber Bragg grating (FBG)-based sensor for precise 2-degree-of-freedom (DoF) ankle angle monitoring. The proposed sensor primarily comprises two symmetric torsion springs, a planar spring, and three FBG-embedded optical fibers. Symmetric torsion springs are employed to measure plantarflexion/dorsiflexion (PF/DF) rotation, while a planar spring targets inversion/eversion (INV/EVE) motion, effectively minimizing cross-axis interference due to their distinct stiffness characteristics. Crucially, the sensor's high in-plane compliance accommodates the physiological shift of the ankle’s rotation center, enabling enhanced wearing comfort. Moreover, a symmetric differential fiber configuration compensates for rotation-axis variations and ensures high measurement accuracy. Structural optimization was conducted to maximize sensitivity and minimize crosstalk. Experimental results demonstrate high sensitivities of 37.09 pm/° (PF/DF) and 224.70 pm/° (INV/EVE) over ±55° and ±23°, respectively. The structural decoupling is validated by a low maximum crosstalk of 3.56%. Furthermore, the sensor maintains accuracy against rotation center offsets, with sensitivity deviations kept below 2.8% under a 2-mm misalignment. Dynamic tests at 50°/s and 300°/s yielded maximum root-mean-square errors (RMSEs) of 2.47° and 1.27° for PF/DF and INV/EVE, respectively. Finally, on-body validation, including seated range-of-motion tests, squat-to-stand exercises, and level walking, confirmed the sensor's ability to capture high-fidelity kinematic profiles for rehabilitation applications.
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Design and Validation of a High-Sensitivity FBG-Based Triaxial Force Sensor With Serially Configured Flexures for Percutaneous Puncture
This article introduces an innovative fiber Bragg grating (FBG)-based triaxial force sensor with high sensitivity for percutaneous puncture applications. The proposed sensor employs the serially configured axial and radial force-sensitive flexures, incorporating tightly suspended optical fibers inscribed with FBG elements. Leveraging the rigid-body replacement method, the designed flexures exhibit selective sensitivities to axial and radial loads, enabling low-coupling triaxial force sensing. The axial force-sensitive flexure combined a semi-bridge mechanism with symmetrical L-shaped levers, amplifying output force while reversing deformation direction. This design maintains the measuring fiber in a purely tensile state, obviating the need for preload adhesion, thereby streamlining assembly and augmenting fiber durability. Finite element method (FEM)-based simulation and structural parameter optimization have been implemented to further enhance the sensitivity. The sensor prototype has been calibrated employing a nonlinear decoupling algorithm based on a backpropagation neural network (BPNN), achieving high resolutions of 2.6 mN within the axial range of 8 N and 0.25 mN within the radial range of ±1 N, with the crosstalk limited to 4.36%. Puncture experiments demonstrated a root mean square error (RMSE) of 3-D resultant forces not exceeding 12.3 mN on ex-vivo tissues, validating the sensor's efficacy and potential in robotic puncture surgery.
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Design and Validation of a High-Sensitivity FBG-Based Triaxial Force Sensor With Serially Configured Flexures for Percutaneous Puncture
This article introduces an innovative fiber Bragg grating (FBG)-based triaxial force sensor with high sensitivity for percutaneous puncture applications. The proposed sensor employs the serially configured axial and radial force-sensitive flexures, incorporating tightly suspended optical fibers inscribed with FBG elements. Leveraging the rigid-body replacement method, the designed flexures exhibit selective sensitivities to axial and radial loads, enabling low-coupling triaxial force sensing. The axial force-sensitive flexure combined a semi-bridge mechanism with symmetrical L-shaped levers, amplifying output force while reversing deformation direction. This design maintains the measuring fiber in a purely tensile state, obviating the need for preload adhesion, thereby streamlining assembly and augmenting fiber durability. Finite element method (FEM)-based simulation and structural parameter optimization have been implemented to further enhance the sensitivity. The sensor prototype has been calibrated employing a nonlinear decoupling algorithm based on a backpropagation neural network (BPNN), achieving high resolutions of 2.6 mN within the axial range of 8 N and 0.25 mN within the radial range of ±1 N, with the crosstalk limited to 4.36%. Puncture experiments demonstrated a root mean square error (RMSE) of 3-D resultant forces not exceeding 12.3 mN on ex-vivo tissues, validating the sensor's efficacy and potential in robotic puncture surgery.
- 3 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (1) , 906-920
Advances in Transanal Quasi-Single-Port Surgery Robotic Systems: A Comprehensive Review
This review highlights the advantages of transanal quasi-single-port surgery (taQSPS) and offers a comprehensive analysis of the development, current applications, and future trends of robotic systems utilized in taQSPS. Timely surgical intervention is crucial for optimal outcomes in rectal cancer treatment, with techniques evolving from open surgery to endoscopic surgery and, more recently, to taQSPS. This innovative technique accesses lesions via a transanal route while utilizing instruments and methods similar to those in single-port surgery (SPS). Building on this foundation, SPS robotic surgical systems have emerged as a promising advancement for taQSPS, offering enhanced precision and maneuverability. However, despite their progress, general-purpose SPS robotic systems are often limited by their bulky design and lack of adaptability to the rectal cavity. In contrast, specialized taQSPS robotic systems are tailored to transanal procedures’ unique anatomical and operational demands, making them highly suitable for such surgeries. This review highlights the potential of specialized taQSPS robotic systems, serving as a valuable reference for researchers and clinicians, and aims to promote further development and adoption of these systems in clinical practice.
- 3 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (1) , 906-920
Advances in Transanal Quasi-Single-Port Surgery Robotic Systems: A Comprehensive Review
This review highlights the advantages of transanal quasi-single-port surgery (taQSPS) and offers a comprehensive analysis of the development, current applications, and future trends of robotic systems utilized in taQSPS. Timely surgical intervention is crucial for optimal outcomes in rectal cancer treatment, with techniques evolving from open surgery to endoscopic surgery and, more recently, to taQSPS. This innovative technique accesses lesions via a transanal route while utilizing instruments and methods similar to those in single-port surgery (SPS). Building on this foundation, SPS robotic surgical systems have emerged as a promising advancement for taQSPS, offering enhanced precision and maneuverability. However, despite their progress, general-purpose SPS robotic systems are often limited by their bulky design and lack of adaptability to the rectal cavity. In contrast, specialized taQSPS robotic systems are tailored to transanal procedures’ unique anatomical and operational demands, making them highly suitable for such surgeries. This review highlights the potential of specialized taQSPS robotic systems, serving as a valuable reference for researchers and clinicians, and aims to promote further development and adoption of these systems in clinical practice.
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (4) , 1416-1430
Design and Performance Investigation of the Microanastomosis Surgical Robot Based on the Novel Dual-Triangular RCM Mechanism
The manual microanastomosis poses significant challenges for surgeons who face inherent limitations in terms of physiological tremor and dexterity constraints. It requires precise repair and reconstruction of small-caliber tissues (0.3-3mm), including vessels, nerves, and lymphatic structures. This study presents a specialized robotic system for microanastomosis based on a 7-degree-of-freedom (DOF) position-orientation decoupled configuration. The system integrates a 3-DOF linear stage for positioning with a novel 3-DOF dual-triangular remote center of motion (RCM) mechanism for orientation control, and a 1-DOF two-finger mimicking end-effector is incorporated to facilitate rapid interchange and precise actuation of different microsurgical instruments. Positioning accuracy was improved through kinematic parameters calibration and RCM point deviation compensation using the linear stage. Experimental results validate the prototype performance in the X-Z plane and Y-Z plane, demonstrating repeatability of 1216μm and 1217μm, respectively, and absolute positioning accuracy of 56115μm and 83135μm. In master-slave control mode, motion accuracy ranges from 14-25μm with a motion scaling ratio between 5x and 20x. Additionally, needle threading and stamen stripping experiments were conducted to validate the robot’s feasibility for microanastomosis surgery.
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (4) , 1416-1430
Design and Performance Investigation of the Microanastomosis Surgical Robot Based on the Novel Dual-Triangular RCM Mechanism
The manual microanastomosis poses significant challenges for surgeons who face inherent limitations in terms of physiological tremor and dexterity constraints. It requires precise repair and reconstruction of small-caliber tissues (0.3-3mm), including vessels, nerves, and lymphatic structures. This study presents a specialized robotic system for microanastomosis based on a 7-degree-of-freedom (DOF) position-orientation decoupled configuration. The system integrates a 3-DOF linear stage for positioning with a novel 3-DOF dual-triangular remote center of motion (RCM) mechanism for orientation control, and a 1-DOF two-finger mimicking end-effector is incorporated to facilitate rapid interchange and precise actuation of different microsurgical instruments. Positioning accuracy was improved through kinematic parameters calibration and RCM point deviation compensation using the linear stage. Experimental results validate the prototype performance in the X-Z plane and Y-Z plane, demonstrating repeatability of 1216μm and 1217μm, respectively, and absolute positioning accuracy of 56115μm and 83135μm. In master-slave control mode, motion accuracy ranges from 14-25μm with a motion scaling ratio between 5x and 20x. Additionally, needle threading and stamen stripping experiments were conducted to validate the robot’s feasibility for microanastomosis surgery.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 5041-5052
Development of a Miniature 5-DOF Modularized Flexible Instrument With Distal Rotation Capability for Dual-Armed Upper Gastrointestinal Endoscopic Robots
The clinical endoluminal flexible instruments exhibit limited degrees of freedom (DOFs) and operational dexterity, making reorientation or repositioning challenging during the complex flexible endoscopic procedure, particularly in endoscopic submucosal dissection (ESD). This work presents a novel 5-DOF miniature flexible instrument for dual-armed upper gastrointestinal endoscopic robots with only 2.6 mm in diameter. It employs a continuum bending section featuring interlocking discrete joints and superelastic NiTi driving rods to achieve high dexterity, accurate positioning with inconspicuous motion hysteresis, and sufficient loading/clamping capacities. The design enables 360° unrestricted distal independent rotation of the forceps, unlike the entire rotation of typical flexible instruments. The central forceps movement slightly impacts the overall positioning accuracy of the instrument with a crosstalk error of less than 1 mm. Kinematic parameter calibration improves the instrument's motion accuracy, achieving an average distal positioning error of 1.56 mm within ±100° in the 2-D plane and 2.29 mm in 3-D space. The distal loading stiffness is 0.29 N/mm and the clamping force exceeds 0.8 N, providing adequate tissue interaction forces during ESD procedures. The modularized instrument prompts the seamless integration of diverse surgical tools, ultimately establishing a dual-armed endoscopic robot. Ex-vivo experiments have been performed to verify its effectiveness in ESD procedures.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 5041-5052
Development of a Miniature 5-DOF Modularized Flexible Instrument With Distal Rotation Capability for Dual-Armed Upper Gastrointestinal Endoscopic Robots
The clinical endoluminal flexible instruments exhibit limited degrees of freedom (DOFs) and operational dexterity, making reorientation or repositioning challenging during the complex flexible endoscopic procedure, particularly in endoscopic submucosal dissection (ESD). This work presents a novel 5-DOF miniature flexible instrument for dual-armed upper gastrointestinal endoscopic robots with only 2.6 mm in diameter. It employs a continuum bending section featuring interlocking discrete joints and superelastic NiTi driving rods to achieve high dexterity, accurate positioning with inconspicuous motion hysteresis, and sufficient loading/clamping capacities. The design enables 360° unrestricted distal independent rotation of the forceps, unlike the entire rotation of typical flexible instruments. The central forceps movement slightly impacts the overall positioning accuracy of the instrument with a crosstalk error of less than 1 mm. Kinematic parameter calibration improves the instrument's motion accuracy, achieving an average distal positioning error of 1.56 mm within ±100° in the 2-D plane and 2.29 mm in 3-D space. The distal loading stiffness is 0.29 N/mm and the clamping force exceeds 0.8 N, providing adequate tissue interaction forces during ESD procedures. The modularized instrument prompts the seamless integration of diverse surgical tools, ultimately establishing a dual-armed endoscopic robot. Ex-vivo experiments have been performed to verify its effectiveness in ESD procedures.
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (6) , 6504-6511
A Phase-Change-Material-Based Variable Stiffness Sheath Inspired by a Multi-Layer Wave Spring Structure for Flexible Upper Gastrointestinal Endoscopic Robots
Continuum robots in flexible gastrointestinal endoscopy require transitioning between flexible and rigid states. Phase-change-material-based variable stiffness (VS) methods exhibit a significant stiffness change ratio but are typically time-consuming. These materials are commonly fabricated as simple cylindrical or tubular structures and integrated with continuum joints, overlooking how the VS module's structural characteristics affect stiffness modulation and bending performance. To balance motion flexibility and operational stability, this work presents a stiffness-tunable sheath inspired by a multi-layer wave spring structure, fabricated utilizing thermoplastic material. A water-based active heating/cooling method is employed, wherein the circulation of hot/cold water through silicone tubes helically wrapped around the VS sheath enables rapid thermal regulation. Structural parameters selection of the VS sheath based on the orthogonal design method has been performed to enhance rigid-state stiffness and reduce maximum stress during 90° flexion in a flexible state. Experimental results showed the proposed VS sheath achieves a stiffness change ratio of up to 16.5 times within 30s. After being integrated with a continuum joint, the sheath demonstrates an average positioning error of 1.48mm within a ±90° bending range in a flexible state, without structural compromise or interference with the continuum joint's bending. In a rigid state, the proposed design can resist 400g external payload with a deflection of less than 6mm. The efficacy of this design has been validated through ex-vivo experiments on a porcine stomach.
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (6) , 6504-6511
A Phase-Change-Material-Based Variable Stiffness Sheath Inspired by a Multi-Layer Wave Spring Structure for Flexible Upper Gastrointestinal Endoscopic Robots
Continuum robots in flexible gastrointestinal endoscopy require transitioning between flexible and rigid states. Phase-change-material-based variable stiffness (VS) methods exhibit a significant stiffness change ratio but are typically time-consuming. These materials are commonly fabricated as simple cylindrical or tubular structures and integrated with continuum joints, overlooking how the VS module's structural characteristics affect stiffness modulation and bending performance. To balance motion flexibility and operational stability, this work presents a stiffness-tunable sheath inspired by a multi-layer wave spring structure, fabricated utilizing thermoplastic material. A water-based active heating/cooling method is employed, wherein the circulation of hot/cold water through silicone tubes helically wrapped around the VS sheath enables rapid thermal regulation. Structural parameters selection of the VS sheath based on the orthogonal design method has been performed to enhance rigid-state stiffness and reduce maximum stress during 90° flexion in a flexible state. Experimental results showed the proposed VS sheath achieves a stiffness change ratio of up to 16.5 times within 30s. After being integrated with a continuum joint, the sheath demonstrates an average positioning error of 1.48mm within a ±90° bending range in a flexible state, without structural compromise or interference with the continuum joint's bending. In a rigid state, the proposed design can resist 400g external payload with a deflection of less than 6mm. The efficacy of this design has been validated through ex-vivo experiments on a porcine stomach.
- 9 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-24
Wearable Fiber Bragg Grating Sensors for Physiological Signal and Body Motion Monitoring: A Review
Wearable sensors play a crucial role in real-time physiological parameters and body motion monitoring, enabling early detection and prevention of potential health issues. However, conventional electrical sensors are susceptible to electromagnetic interference (EMI), limiting their application in magnetic resonance imaging (MRI), electrosurgery, and humid environments. Optical wearable devices based on fiber Bragg gratings (FBGs) offer distinct advantages such as miniaturization, immunity to EMI, high sensitivity, and multiplexing capabilities, making them promising for healthcare applications. Nevertheless, FBG sensors face challenges such as susceptibility to breakage and cross-sensitivity to temperature and multiple strain signals, creating obstacles in expanding strain monitoring range, reducing monitoring errors, and improving wear resistance. This review comprehensively introduces the latest advancements, technical challenges, and potential solutions associated with wearable FBG sensing devices for detecting physiological signals and body motion, particularly emphasizing their applications in monitoring small- and large-strain body movements. This article focuses on the sensing characteristics of FBG units in both soft and rigid substrate materials and tracks the advancement in sensing structure optimization for enhanced measurement capabilities. Future directions and opportunities for technological improvement in this field are also discussed.
- 9 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-24
Wearable Fiber Bragg Grating Sensors for Physiological Signal and Body Motion Monitoring: A Review
Wearable sensors play a crucial role in real-time physiological parameters and body motion monitoring, enabling early detection and prevention of potential health issues. However, conventional electrical sensors are susceptible to electromagnetic interference (EMI), limiting their application in magnetic resonance imaging (MRI), electrosurgery, and humid environments. Optical wearable devices based on fiber Bragg gratings (FBGs) offer distinct advantages such as miniaturization, immunity to EMI, high sensitivity, and multiplexing capabilities, making them promising for healthcare applications. Nevertheless, FBG sensors face challenges such as susceptibility to breakage and cross-sensitivity to temperature and multiple strain signals, creating obstacles in expanding strain monitoring range, reducing monitoring errors, and improving wear resistance. This review comprehensively introduces the latest advancements, technical challenges, and potential solutions associated with wearable FBG sensing devices for detecting physiological signals and body motion, particularly emphasizing their applications in monitoring small- and large-strain body movements. This article focuses on the sensing characteristics of FBG units in both soft and rigid substrate materials and tracks the advancement in sensing structure optimization for enhanced measurement capabilities. Future directions and opportunities for technological improvement in this field are also discussed.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
Development of a Novel DNA-Inspired Continuum Joint (DICJ) for a Robotic Flexible Endoscopic Instrument
This paper introduces a DNA-inspired continuum joint (DICJ) for enhancing the performance of flexible endoscopic instruments. The proposed joint mimics the structural properties of DNA molecules, including an outer helical structure and four coaxially nested inner helical backbones, improving compressive and torsional stiffness. This biomimetic design leverages a stable multi-helix configuration to enhance mechanical properties, such as minimal stress concentration, improved flexibility for large bending angles, constant curvature, and high payload capacity. FEA-based simulations and kinematic analysis were conducted to optimize the structure, demonstrating superior stiffness and reduced parasitic motion. Experimental investigations on the structural performance revealed excellent constant curvature characteristics, with a maximum bending angle of 242.7°, and significantly improved torsional and axial stiffness (1.324 mN∙m/° and 2.948 N/mm, respectively). The DICJ joint exhibited a maximum payload capacity of 10 N. Experiments on visual coverage and obstacle avoidance showed enhanced dexterity and expanded the surgical field of view, validating the potential of the DICJ joint for minimally invasive surgery, with notable improvements in workspace and loading capabilities.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
Development of a Novel DNA-Inspired Continuum Joint (DICJ) for a Robotic Flexible Endoscopic Instrument
This paper introduces a DNA-inspired continuum joint (DICJ) for enhancing the performance of flexible endoscopic instruments. The proposed joint mimics the structural properties of DNA molecules, including an outer helical structure and four coaxially nested inner helical backbones, improving compressive and torsional stiffness. This biomimetic design leverages a stable multi-helix configuration to enhance mechanical properties, such as minimal stress concentration, improved flexibility for large bending angles, constant curvature, and high payload capacity. FEA-based simulations and kinematic analysis were conducted to optimize the structure, demonstrating superior stiffness and reduced parasitic motion. Experimental investigations on the structural performance revealed excellent constant curvature characteristics, with a maximum bending angle of 242.7°, and significantly improved torsional and axial stiffness (1.324 mN∙m/° and 2.948 N/mm, respectively). The DICJ joint exhibited a maximum payload capacity of 10 N. Experiments on visual coverage and obstacle avoidance showed enhanced dexterity and expanded the surgical field of view, validating the potential of the DICJ joint for minimally invasive surgery, with notable improvements in workspace and loading capabilities.
- Open Access
- 1 March 2021
- Published by Elsevier in Pharmacological Research
- Vol. 165, 105464
Effect of Qizhitongluo capsule on lower limb rehabilitation after stroke: A randomized clinical trial
- 1 March 2021
- Published by Elsevier in Pharmacological Research
- Vol. 165, 105464
Open AccessEffect of Qizhitongluo capsule on lower limb rehabilitation after stroke: A randomized clinical trial