Martin R. Pfaller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Martin R. Pfaller has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
- Alison Lesley Marsden
Institute for Computational and Mathematical Engineering, Stanford University, Stanford, USA
8 shared publications - Cristóbal Bertoglio
University of Groningen
6 shared publications Wolfgang A. Wall
Institute for Computational Mechanics, Technical University of Munich
6 shared publicationsAlison L. Marsden
Department of Pediatrics, Stanford University
5 shared publicationsDavid W. Parker
4 shared publications- Wolfgang A. Wall
Institute for Computational Mechanics, Technical University of Munich, Garching b. München, Germany
4 shared publications
Latest Publications
- 13 March 2025
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 383 (2292) , 20240223
Bayesian Windkessel calibration using optimized zero-dimensional surrogate models
Bayesian boundary condition (BC) calibration approaches from clinical measurements have successfully quantified inherent uncertainties in cardiovascular fluid dynamics simulations. However, estimating the posterior distribution for all BC parameters in three-dimensional (3D) simulations has been unattainable due to infeasible computational demand. We propose an efficient method to identify Windkessel parameter posteriors: We only evaluate the 3D model once for an initial choice of BCs and use the result to create a highly accurate zero-dimensional (0D) surrogate. We then perform Sequential Monte Carlo (SMC) using the optimized 0D model to derive the high-dimensional Windkessel BC posterior distribution. Optimizing 0D models to match 3D data a priori lowered their median approximation error by nearly one order of magnitude in 72 publicly available vascular models. The optimized 0D models generalized well to a wide range of BCs. Using SMC, we evaluated the high-dimensional Windkessel parameter posterior for different measured signal-to-noise ratios in a vascular model, which we validated against a 3D posterior. The minimal computational demand of our method using a single 3D simulation, combined with the open-source nature of all software and data used in this work, will increase access and efficiency of Bayesian Windkessel calibration in cardiovascular fluid dynamics simulations. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 1)’.
- 13 March 2025
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 383 (2292) , 20240223
Bayesian Windkessel calibration using optimized zero-dimensional surrogate models
Bayesian boundary condition (BC) calibration approaches from clinical measurements have successfully quantified inherent uncertainties in cardiovascular fluid dynamics simulations. However, estimating the posterior distribution for all BC parameters in three-dimensional (3D) simulations has been unattainable due to infeasible computational demand. We propose an efficient method to identify Windkessel parameter posteriors: We only evaluate the 3D model once for an initial choice of BCs and use the result to create a highly accurate zero-dimensional (0D) surrogate. We then perform Sequential Monte Carlo (SMC) using the optimized 0D model to derive the high-dimensional Windkessel BC posterior distribution. Optimizing 0D models to match 3D data a priori lowered their median approximation error by nearly one order of magnitude in 72 publicly available vascular models. The optimized 0D models generalized well to a wide range of BCs. Using SMC, we evaluated the high-dimensional Windkessel parameter posterior for different measured signal-to-noise ratios in a vascular model, which we validated against a 3D posterior. The minimal computational demand of our method using a single 3D simulation, combined with the open-source nature of all software and data used in this work, will increase access and efficiency of Bayesian Windkessel calibration in cardiovascular fluid dynamics simulations. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 1)’.
- Open Access
- 10 March 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 189, 109914
Patient-specific coronary angioplasty simulations — A mixed-dimensional finite element modeling approach
- 10 March 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 189, 109914
Open AccessPatient-specific coronary angioplasty simulations — A mixed-dimensional finite element modeling approach
- Open Access
- 19 December 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 435
A software benchmark for cardiac elastodynamics
- 19 December 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 435
Open AccessA software benchmark for cardiac elastodynamics
- Open Access
- 14 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (3) , 953-964
Assessment of Aortic Dissection Remodeling With Patient-Specific Fluid–Structure Interaction Models
Aortic dissection leads to late complications due tochronic degeneration and dilatation of the false lumen. This study examines the interaction between hemodynamics and long-term remodeling of a patient's aortic dissection, tracked from pre-dissection to the chronic phase using CT angiography. Fluid–structure interaction models with tissue prestress, external support, and anisotropic properties were used to analyze hemodynamic markers. Each aortic wall layer had distinct thicknesses and material properties. The boundary conditions were guided by in vitro 4D-flow MRI and the patient's blood pressure. Aortic dilatation was most significant distal to the left subclavian artery, reaching 6 cm in the chronic phase. Simulations quantified the flow jet velocity through the entry tear, which peaked at 185 cm/s in the subacute phase and decreased to 123 to 133 cm/s in the chronic phase, corresponding to an increased entry tear size. Flow jet impingement on the false lumen resulted in a localized pressure increase of 11 and 2 mmHg in the subacute and chronic phases, with wall shear stress reaching 4 Pa. These hemodynamic changes appear to be the main drivers of aortic growth and morphological changes. Despite moderate overall flap movement, in-plane displacement increased from 0.6 to 1.8 mm as disease progressed, which was associated with an overall increase in aortic diameter. Simulations with a significant reduction in flap stiffness during the subacute phase resulted in increased flap motion up to 9.5 mm. Although these results are based on a single patient, they suggest a strong relationship between hemodynamics and aortic growth.
- 14 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (3) , 953-964
Open AccessAssessment of Aortic Dissection Remodeling With Patient-Specific Fluid–Structure Interaction Models
Aortic dissection leads to late complications due tochronic degeneration and dilatation of the false lumen. This study examines the interaction between hemodynamics and long-term remodeling of a patient's aortic dissection, tracked from pre-dissection to the chronic phase using CT angiography. Fluid–structure interaction models with tissue prestress, external support, and anisotropic properties were used to analyze hemodynamic markers. Each aortic wall layer had distinct thicknesses and material properties. The boundary conditions were guided by in vitro 4D-flow MRI and the patient's blood pressure. Aortic dilatation was most significant distal to the left subclavian artery, reaching 6 cm in the chronic phase. Simulations quantified the flow jet velocity through the entry tear, which peaked at 185 cm/s in the subacute phase and decreased to 123 to 133 cm/s in the chronic phase, corresponding to an increased entry tear size. Flow jet impingement on the false lumen resulted in a localized pressure increase of 11 and 2 mmHg in the subacute and chronic phases, with wall shear stress reaching 4 Pa. These hemodynamic changes appear to be the main drivers of aortic growth and morphological changes. Despite moderate overall flap movement, in-plane displacement increased from 0.6 to 1.8 mm as disease progressed, which was associated with an overall increase in aortic diameter. Simulations with a significant reduction in flap stiffness during the subacute phase resulted in increased flap motion up to 9.5 mm. Although these results are based on a single patient, they suggest a strong relationship between hemodynamics and aortic growth.
- Open Access
- 19 September 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (11) , e3869
Adaptive integration of history variables in constrained mixture models for organ‐scale growth and remodeling
In the last decades, many computational models have been developed to predict soft tissue growth and remodeling (G&R). The constrained mixture theory describes fundamental mechanobiological processes in soft tissue G&R and has been widely adopted in cardiovascular models of G&R. However, even after two decades of work, large organ‐scale models are rare, mainly due to high computational costs (model evaluation and memory consumption), especially in long‐range simulations. We propose two strategies to adaptively integrate history variables in constrained mixture models to enable large organ‐scale simulations of G&R. Both strategies exploit that the influence of deposited tissue on the current mixture decreases over time through degradation. One strategy is independent of external loading, allowing the estimation of the computational resources ahead of the simulation. The other adapts the history snapshots based on the local mechanobiological environment so that the additional integration errors can be controlled and kept negligibly small, even in G&R scenarios with severe perturbations. We analyze the adaptively integrated constrained mixture model on a tissue patch for a parameter study and show the performance under different G&R scenarios. To confirm that adaptive strategies enable large organ‐scale examples, we show simulations of different hypertension conditions with a real‐world example of a biventricular heart discretized with a finite element mesh. In our example, adaptive integrations sped up simulations by a factor of three and reduced memory requirements to one‐sixth. The reduction of the computational costs gets even more pronounced for simulations over longer periods. Adaptive integration of the history variables allows studying more finely resolved models and longer G&R periods while computational costs are drastically reduced and largely constant in time.
- 19 September 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (11) , e3869
Open AccessAdaptive integration of history variables in constrained mixture models for organ‐scale growth and remodeling
In the last decades, many computational models have been developed to predict soft tissue growth and remodeling (G&R). The constrained mixture theory describes fundamental mechanobiological processes in soft tissue G&R and has been widely adopted in cardiovascular models of G&R. However, even after two decades of work, large organ‐scale models are rare, mainly due to high computational costs (model evaluation and memory consumption), especially in long‐range simulations. We propose two strategies to adaptively integrate history variables in constrained mixture models to enable large organ‐scale simulations of G&R. Both strategies exploit that the influence of deposited tissue on the current mixture decreases over time through degradation. One strategy is independent of external loading, allowing the estimation of the computational resources ahead of the simulation. The other adapts the history snapshots based on the local mechanobiological environment so that the additional integration errors can be controlled and kept negligibly small, even in G&R scenarios with severe perturbations. We analyze the adaptively integrated constrained mixture model on a tissue patch for a parameter study and show the performance under different G&R scenarios. To confirm that adaptive strategies enable large organ‐scale examples, we show simulations of different hypertension conditions with a real‐world example of a biventricular heart discretized with a finite element mesh. In our example, adaptive integrations sped up simulations by a factor of three and reduced memory requirements to one‐sixth. The reduction of the computational costs gets even more pronounced for simulations over longer periods. Adaptive integration of the history variables allows studying more finely resolved models and longer G&R periods while computational costs are drastically reduced and largely constant in time.
- 6 August 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 431
FSGe: A fast and strongly-coupled 3D fluid–solid-growth interaction method
- 6 August 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 431
FSGe: A fast and strongly-coupled 3D fluid–solid-growth interaction method
- 27 March 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (5) , e3820
A probabilistic neural twin for treatment planning in peripheral pulmonary artery stenosis
The substantial computational cost of high‐fidelity models in numerical hemodynamics has, so far, relegated their use mainly to offline treatment planning. New breakthroughs in data‐driven architectures and optimization techniques for fast surrogate modeling provide an exciting opportunity to overcome these limitations, enabling the use of such technology for time‐critical decisions. We discuss an application to the repair of multiple stenosis in peripheral pulmonary artery disease through either transcatheter pulmonary artery rehabilitation or surgery, where it is of interest to achieve desired pressures and flows at specific locations in the pulmonary artery tree, while minimizing the risk for the patient. Since different degrees of success can be achieved in practice during treatment, we formulate the problem in probability, and solve it through a sample‐based approach. We propose a new offline–online pipeline for probabilistic real‐time treatment planning which combines offline assimilation of boundary conditions, model reduction, and training dataset generation with online estimation of marginal probabilities, possibly conditioned on the degree of augmentation observed in already repaired lesions. Moreover, we propose a new approach for the parametrization of arbitrarily shaped vascular repairs through iterative corrections of a zero‐dimensional approximant. We demonstrate this pipeline for a diseased model of the pulmonary artery tree available through the Vascular Model Repository.
- 27 March 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (5) , e3820
A probabilistic neural twin for treatment planning in peripheral pulmonary artery stenosis
The substantial computational cost of high‐fidelity models in numerical hemodynamics has, so far, relegated their use mainly to offline treatment planning. New breakthroughs in data‐driven architectures and optimization techniques for fast surrogate modeling provide an exciting opportunity to overcome these limitations, enabling the use of such technology for time‐critical decisions. We discuss an application to the repair of multiple stenosis in peripheral pulmonary artery disease through either transcatheter pulmonary artery rehabilitation or surgery, where it is of interest to achieve desired pressures and flows at specific locations in the pulmonary artery tree, while minimizing the risk for the patient. Since different degrees of success can be achieved in practice during treatment, we formulate the problem in probability, and solve it through a sample‐based approach. We propose a new offline–online pipeline for probabilistic real‐time treatment planning which combines offline assimilation of boundary conditions, model reduction, and training dataset generation with online estimation of marginal probabilities, possibly conditioned on the degree of augmentation observed in already repaired lesions. Moreover, we propose a new approach for the parametrization of arbitrarily shaped vascular repairs through iterative corrections of a zero‐dimensional approximant. We demonstrate this pipeline for a diseased model of the pulmonary artery tree available through the Vascular Model Repository.
- 10 February 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (5) , 1-12
Non-invasive Estimation of Pressure Drop Across Aortic Coarctations: Validation of 0D and 3D Computational Models with In Vivo Measurements
Blood pressure gradient (\(\Delta P\)) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of \(\Delta P\) estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N = 17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. \(\Delta P\) across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. The 0D simulations were extremely efficient (\(\sim\) 15 s computation time) compared to 3D simulations (\(\sim\) 30 h computation time on a cluster). However, the 0D \(\Delta P\) estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as \(\Delta P\) \(\ge\) 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.- 10 February 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (5) , 1-12
Non-invasive Estimation of Pressure Drop Across Aortic Coarctations: Validation of 0D and 3D Computational Models with In Vivo Measurements
Blood pressure gradient (\(\Delta P\)) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of \(\Delta P\) estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N = 17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. \(\Delta P\) across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. The 0D simulations were extremely efficient (\(\sim\) 15 s computation time) compared to 3D simulations (\(\sim\) 30 h computation time on a cluster). However, the 0D \(\Delta P\) estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as \(\Delta P\) \(\ge\) 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.- 19 January 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 421
A modular framework for implicit 3D–0D coupling in cardiac mechanics
- 19 January 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 421
A modular framework for implicit 3D–0D coupling in cardiac mechanics
- Open Access
Non-invasive estimation of pressure drop across aortic coarctations: validation of 0D and 3D computational models with in vivo measurements
Purpose: Blood pressure gradient ( Δ P) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of Δ P estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Methods: Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N=17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. Δ P across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. Results: The 0D simulations were extremely efficient ( ∼ 15 secs computation time) compared to 3D simulations ( ∼ 30 hrs computation time on a cluster). However, the 0D Δ P estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as Δ P ≥ 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Conclusion: Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.
Open AccessNon-invasive estimation of pressure drop across aortic coarctations: validation of 0D and 3D computational models with in vivo measurements
Purpose: Blood pressure gradient ( Δ P) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of Δ P estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Methods: Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N=17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. Δ P across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. Results: The 0D simulations were extremely efficient ( ∼ 15 secs computation time) compared to 3D simulations ( ∼ 30 hrs computation time on a cluster). However, the 0D Δ P estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as Δ P ≥ 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Conclusion: Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.