Thomas Guiho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas Guiho has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Arthur Hiairrassary
Camin Team, INRIA, University of Montpellier, France
1 shared publication Christine Azevedo-Coste
University of Montpellier, INRIA, Montpellier, Occitanie, France
1 shared publicationClaire Delleci
Departments of3Physical Medicine and Rehabilitation
1 shared publicationDavid Guiraud
University of Montpellier, INRIA, Montpellier, Occitanie, France
1 shared publication- David Guiraud
Camin Team, INRIA, University of Montpellier, Montpellier, France
1 shared publication - Eduardo Fernandez
Rome Campus, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
1 shared publication
Latest Publications
- Open Access
On the Reliability of Chronically Implanted Thin-Film Electrodes in Human Arm Nerves for Neuroprosthetic Applications
Direct stimulation of peripheral nerves can successfully provide sensory feedback to amputees while using hand prostheses. Recent clinical studies have addressed this important limitation of current prostheses solutions using different implantable electrode concepts. Longevity of the electrodes is key to success. We have improved the long-term stability of the polyimide-based transverse intrafascicular multichannel electrode (TIME) that showed promising performance in clinical trials by integration of silicon carbide adhesion layers. The TIMEs were implanted in the median and ulnar nerves of three trans-radial amputees for up to six months. Here, we present the characterization of the electrical properties of the thin-film metallization as well as material status post explantationem for the first time. The TIMEs showed reliable performance in terms of eliciting sensation and stayed within the electrochemical safe limits maintaining a good working range with respect to amplitude modulation. After termination of the trials and explantation of the probes, no signs of corrosion or morphological change to the thin-film metallization was observed by means of electrochemical and optical analysis. Damage to the metallization was assigned exclusively to mechanical impacts during explantation and handling. The results indicate that thin-film metallization on polymer substrates is applicable in permanent implant system.
Open AccessOn the Reliability of Chronically Implanted Thin-Film Electrodes in Human Arm Nerves for Neuroprosthetic Applications
Direct stimulation of peripheral nerves can successfully provide sensory feedback to amputees while using hand prostheses. Recent clinical studies have addressed this important limitation of current prostheses solutions using different implantable electrode concepts. Longevity of the electrodes is key to success. We have improved the long-term stability of the polyimide-based transverse intrafascicular multichannel electrode (TIME) that showed promising performance in clinical trials by integration of silicon carbide adhesion layers. The TIMEs were implanted in the median and ulnar nerves of three trans-radial amputees for up to six months. Here, we present the characterization of the electrical properties of the thin-film metallization as well as material status post explantationem for the first time. The TIMEs showed reliable performance in terms of eliciting sensation and stayed within the electrochemical safe limits maintaining a good working range with respect to amplitude modulation. After termination of the trials and explantation of the probes, no signs of corrosion or morphological change to the thin-film metallization was observed by means of electrochemical and optical analysis. Damage to the metallization was assigned exclusively to mechanical impacts during explantation and handling. The results indicate that thin-film metallization on polymer substrates is applicable in permanent implant system.
- 1 May 2019
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 30 (5) , 644-654
Validation of a methodology for neuro-urological and lumbosacral stimulation studies in domestic pigs: a humanlike animal model
OBJECTIVE: Spinal cord injuries (SCIs) result in loss of movement and sensory feedback, but also organ dysfunction. Nearly all patients with complete SCI lose bladder control and are prone to kidney failure if intermittent catheterization is not performed. Electrical stimulation of sacral spinal roots was initially considered to be a promising approach for restoring continence and micturition control, but many patients are discouraged by the need for surgical deafferentation as it could lead to a loss of sensory functions and reflexes. Nevertheless, recent research findings highlight the renewed interest in spinal cord stimulation (SCS). It is thought that synergic recruitment of spinal fibers could be achieved by stimulating the spinal neural networks involved in regulating physiological processes. Paradoxically, most of these recent studies focused on locomotor issues, while few addressed visceral dysfunction. This could at least partially be attributed to the lack of methodological tools. In this study, the authors aim to fill this gap by presenting a comprehensive method for investigating the potential of SCS to restore visceral functions in domestic pigs, a large-animal model considered to be a close approximation to humans.METHODS: This methodology was tested in 7 female pigs (Landrace pig breed, 45–60 kg, 4 months old) during acute experiments. A combination of morphine and propofol was used for anesthesia when transurethral catheterization and lumbosacral laminectomy (L4–S4) were performed. At the end of the operation, spinal root stimulation (L6–S5) and urodynamic recordings were performed to compare the evoked responses with those observed intraoperatively in humans.RESULTS: Nervous excitability was preserved despite long-term anesthesia (mean 8.43 ± 1.5 hours). Transurethral catheterization and conventional laminectomy were possible while motor responses (gluteus muscle monitoring) were unaffected throughout the procedure. Consistent detrusor (approximately 25 cm H2O) and sphincter responses were obtained, whereas spinal root stimulation elicited detrusor and external urethral sphincter co-contractions similar to those observed intraoperatively in humans.CONCLUSIONS: Pigs represent an ideal model for SCS studies aimed at visceral function investigation and restoration because of the close similarities between female domestic pigs and humans, both in terms of anatomical structure and experimental techniques implemented. This article provides methodological keys for conducting experiments with equipment routinely used in clinical practice.
- 1 May 2019
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 30 (5) , 644-654
Validation of a methodology for neuro-urological and lumbosacral stimulation studies in domestic pigs: a humanlike animal model
OBJECTIVE: Spinal cord injuries (SCIs) result in loss of movement and sensory feedback, but also organ dysfunction. Nearly all patients with complete SCI lose bladder control and are prone to kidney failure if intermittent catheterization is not performed. Electrical stimulation of sacral spinal roots was initially considered to be a promising approach for restoring continence and micturition control, but many patients are discouraged by the need for surgical deafferentation as it could lead to a loss of sensory functions and reflexes. Nevertheless, recent research findings highlight the renewed interest in spinal cord stimulation (SCS). It is thought that synergic recruitment of spinal fibers could be achieved by stimulating the spinal neural networks involved in regulating physiological processes. Paradoxically, most of these recent studies focused on locomotor issues, while few addressed visceral dysfunction. This could at least partially be attributed to the lack of methodological tools. In this study, the authors aim to fill this gap by presenting a comprehensive method for investigating the potential of SCS to restore visceral functions in domestic pigs, a large-animal model considered to be a close approximation to humans.METHODS: This methodology was tested in 7 female pigs (Landrace pig breed, 45–60 kg, 4 months old) during acute experiments. A combination of morphine and propofol was used for anesthesia when transurethral catheterization and lumbosacral laminectomy (L4–S4) were performed. At the end of the operation, spinal root stimulation (L6–S5) and urodynamic recordings were performed to compare the evoked responses with those observed intraoperatively in humans.RESULTS: Nervous excitability was preserved despite long-term anesthesia (mean 8.43 ± 1.5 hours). Transurethral catheterization and conventional laminectomy were possible while motor responses (gluteus muscle monitoring) were unaffected throughout the procedure. Consistent detrusor (approximately 25 cm H2O) and sphincter responses were obtained, whereas spinal root stimulation elicited detrusor and external urethral sphincter co-contractions similar to those observed intraoperatively in humans.CONCLUSIONS: Pigs represent an ideal model for SCS studies aimed at visceral function investigation and restoration because of the close similarities between female domestic pigs and humans, both in terms of anatomical structure and experimental techniques implemented. This article provides methodological keys for conducting experiments with equipment routinely used in clinical practice.